NuTone 9297T User Manual

Ceiling Heater
MODEL: 9297T
INSTALLATION INSTRUCTIONS
READ & SAVE THESE INSTRUCTIONS!
IMPORTANT SAFETY INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOW­ING:
1. All electrical work must be done in accordance with local and/ or national electrical code as applicable. For safety, this prod­uct must be grounded. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician.
2. Turn off power at service entrance before installing, wiring or servicing this product.
3. This product is designed for horizontal ceiling installation only. Do not mount this product on a wall or sloped ceiling.
4. Do not install heater closer than 12" to any adjacent vertical surface.
5. To avoid electrical shock:
Do not install unit in a tub or shower enclosure.
Never place a switch where it can be reached from a tub or
shower.
6. Provide heater with a separate 20 amp (minimum), 120 VAC circuit.
7. Do not connect heater to dimmer switch or speed control.
8. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
9. Please read specification label on product for further informa­tion and requirements.
PLAN THE INSTALLATION
This heater is intended to be used to supply supplemental heat from a ceiling location in new or existing construction.
Choose a location where edge of heater will be at least 12" from any adjacent vertical surface.
The heater can be operated using an ON/OFF switch, timer (Model VS62WH 60-Minute or Model VS63WH 15-Minute Timer). Pur­chase the control separately.
Plan to supply the heater with proper line voltage and appropriate power cable for its maximum wattage rating.
The heater attaches directly to a standard 3" or 4" ceiling electrical box.
Refer to FIGURE 1
Follow these basic steps when installing this heater:
1. Mount electrical box in ceiling and attach power cable to it.
2. Connect wiring and fasten heater to electrical box.
3. Install grille.
CEILING
ELECTRICAL
BOX
DRYWALL
CEILING JOIST
GRILLE SCREW
HEATER
FIGURE 1
INSTALLATION
Refer to FIGURE 2
1. Mount electrical box. Position electrical box flush or slightly recessed in ceiling and mount it securely.
Refer to FIGURE 3
2. Connect wiring. Run electrical cable into box and secure with appropriate connector. Allow 6" of wire inside box.
Refer to FIGURE 4 and FIGURE 5
3. Wire the heater. Attach electrical power cable to heater. Con­nect black to black, white to white, and green or bare wire to ground screw. Complete the wiring by adding a wall control. Follow the pictorial or schematic diagram.
Refer to FIGURE 6, FIGURE 7, and FIGURE 8
4. Attach heater to electrical box. Tuck wires up into electrical box. Fit screw heads from electrical box into appropriate keyholes, as shown. Twist heater clockwise to hold it in place. Tighten two (2) electrical box screws.
Refer to FIGURE 9
5. Install grille. Use grille screw (provided) to attach grille, as shown.
USE AND CARE
CAUTION – DISCONNECT ELECTRIC POWER SUPPLY AT SER­VICE ENTRANCE BEFORE CLEANING OR SERVICING UNIT.
Cleaning:
To clean the heater assembly, carefully clean through heater grille, using the round brush tool on your vacuum cleaner. Remove accu­mulations of dust, lint, etc., that might impede the flow of air through the heater. Such blockage will lower its efficiency and create a pos­sible overheat condition.
CAUTION – METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.
FIGURE 2
FIGURE 3
GROUND
SCREW
TOGGLE SWITCH
THERMOSTAT
GREEN OR
BARE WIRE
WHITE
BLACK
SWITCH
BOX
TIMER OR
WHITE
BLACK
GROUND
120 VAC 60 HZ LINE IN
FIGURE 4
2
TOGGLE SWITCH,
TIMER, OR
THERMOSTAT
HEATING ELEMENT
BLACK
BLACK
120 VAC LINE IN
M
BLACK
GROUND
GROUND
T
WHITE
WHITE
WHITE
FIGURE 8
CEILING BOX
SWITCH BOX
FIGURE 9
FIGURE 5
FIGURE 6
FIGURE 7
3