NuTone 605RP User Manual

Architectural & Engineering Specifications
March 2004
Heat-A-Vent
®
MODEL: 605RP
DESCRIPTION
Two functions in one unit. Use them individually
or together.
2) Exhausts stale air and moisture to refresh the bath atmosphere.
Streamline design with handsome white grille. Grille
is tough polymeric, impervious to bathroom climate.
Includes adjustable hanger bars. 16"-24". Built-in
junction box with receptacles for simple plug-in of heater and fan motors.
Nickel-chrome heating element.
Quiet polypropylene duct adapter with silent backdraft
damper snaps on. Longer tapering collar for easy attachment of 4" duct.
Connects to 120vAC.
For your convenience, NuTone offers a complete line
of accessories to adapt this unit to your construction requirements.
DESIGN FEATURES
Air Delivery: 70 CFM. Sound Level: 4.0 Sones. British Thermal 5118. Units: Dimensions: Housing: 145⁄8" x 77⁄8" x 55⁄8".
Grille: 97⁄8" x 161⁄4". Material & Housing: Galvanized steel, Component Data: Grille: White polymeric.
Damper: polypropylene. Impellers: Centrifugal. Motors: Sleeve bearings, thermally protected. Element: Open coil, nickel-chromium. 1500W. Duct Size: 4" diameter. Electrical Rating: 120V, 60Hz, 13.5A
INSTALLATION
• Adjustable hanger bars attach to 16" or 24" O.C. joists in new construction.
• Built-in junction box accepts plug-in heater motor, and fan motor.
• Duct adapter has built-in damper and long, tapering collar for duct attachment.
• Discharge is horizontal through 4" round duct.
• Each unit includes complete Installation Instructions for both new and existing construction.
Do not install unit over bath tub or in shower stall.
• Connect to 20 amp branch circuit.
ARCHITECT'S SPECIFICATIONS
Heat-Vent Combination shall be Model 605RP as
manufactured by NuTone according to listed specifications.
NUTONE, INC. / 4820 RED BANK ROAD, CINCINNATI, OHIO 45227
Product specifications subject to change without notice.
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
CERTIFIED TEST DATA
Air delivery and sound level ratings are certified by the Home Ventilating Institute Division of AMCA, based on testing performed by an independent third party testing laboratory, in accordance with HVI standards. This NuTone model is listed by Underwriters' Laboratories Inc.
The air delivery of a ventilating system may be determined by:
1. Determine the equivalent duct length for each 90 degree
elbow by adding one foot of duct length for each inch of
duct diameter, i.e., a 4 inch diameter duct elbow equals
4 feet equivalent duct length and an 8 inch diameter
duct elbow equals 8 feet equivalent duct length.
2. Add the total straight length of duct and the equivalent
length for each elbow to obtain the total equivalent
duct length.
3. Locate the intersection of the fan performance curve and
the total equivalent duct length curves and draw a vertical
line down to the CFM scale and read the system air
performance.
(NOTE: 31⁄4" x 10" duct equals 6 inch diameter duct.)
DIMENSIONS
1
6
1
/4"
1
4 5/8
"
17
1/8
"
5 5
/8
"
9
7
/8
"
7
7
/8"
0.45
AIR PERFORMANCE CURVE
(4 In. Duct to 10 Foot Lengths)
STATIC PRESSURE INCHES OF WATER
CFM
0.05
76 73 71 68 66 64 62 60 57 54
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.5
10 050
0
0.0 0
0.10
0.20
0.3 0
0.4 0
0.5 0
STATIC PRESSURE–INCHES OF WATER
50 Feet
40 Feet
30 Feet
20 Feet
10 Feet
CFM CUBIC FEET PER MINUTE
75 12525