![](/html/20/2050/20503039abf293f66426158c7df3df63c5b4833d0c19d5ac4a40b43824f3c9a3/bg1.png)
DESCRIPTION
HOUSING:
• Rugged, 26-gauge galvanized steel construction
• Key-holed mounting brackets span up to 24” and are adjustable
horizontally and vertically
• Reversible knockout bracket allows wiring from top or side
• 4” round duct tting with built-in backdraft damper for easy duct
connection
BLOWER:
• Plug-in, permanently lubricated motor
• Totally enclosed motor with long life bearings designed for
continuous operation (HD80RDB, HD50RDB only)
• Centrifugal blower wheel
RADIATION DAMPER:
• For use in 1, 2 and 3 hour rated oor-ceiling and roof-ceiling
constructions
• Galvanized steel frame
• High temperature, non-asbestos, reinforced ber thermal fabric
• Stainless steel closure springs
• 165°F fusible link
GRILLE:
• Attractive steel grille painted white
• Low prole blends well with any decor
(1) rough-in Kit & (1) finish Kit maKe a
complete unit. purchase each separately.
Rough-In Kit
Model RDA • Contains housing and radiation damper
(packed 4 per carton).
Finish Kits
Models 110RDB, 80RDB, HD80RDB and HD50RDB •
Contain blower and grille (packed 4 per carton).
SPECIFICATIONS
RDA with VOLTS AMPS CFM SONES DUCT
110RDB 120 1.3 110 4.0 4”
ROUND
80RDB 120 0.5 80 2.5 4”
ROUND
HD80RDB 120 0.5 80 2.5 4”
ROUND
HD50RDB 120 0.4 50 1.5 4”
ROUND
Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
Architectural & Engineering Specications
February 2008
Ventilating Fans With
Radiation Dampers
MODEL
RDA
RDB
MODELS
INSTALLATION
Complete installation instructions are included with each Ventilating
Fan Kit.
ARCHITECT’S SPECIFICATION
Ventilation Fan with Radiation Damper shall be NuTone Model
RDA with 110RDB (RDA with 80RDB) (RDA with HD80RDB) (RDA
with HD50RDB).
Housing shall be made of galvanized steel and have adjustable
mounting brackets. It shall have a built-in backdraft damper and
be ducted to a roof or wall cap.
Blower shall be removable and have a centrifugal blower wheel.
Motor shall be permanently lubricated.
Air delivery shall be no less than and sound level shall be no
greater than values listed in the chart to the left. Air and sound
ratings shall be certied by HVI.
Radiation damper shall be rated for use in up to three hour ceiling
constructions. It shall be UL Classied and Warnock Hersey Listed
(see other side for installation details).
Ventilation Fan with Radiation Damper shall be Energy Star
qualied (Model HD50RDB only).
CLASSIFIED
Model
HD50RDB
only
®
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
80B 99043057D
![](/html/20/2050/20503039abf293f66426158c7df3df63c5b4833d0c19d5ac4a40b43824f3c9a3/bg2.png)
Ventilating Fans
with
Radiation Dampers
CLASSIFIED
FAN
SEE DETAILS ON UL
CLASSIFICATION
MARKING ON
PRODUCT
DAMPER
MOUNTING
BRACKET
WIRE
WARNOCK HERSEY LISTING
INCLUDES DAMPER ONLY. IT
DOES NOT INCLUDE EXHAUST
FAN. DAMPERS MAY BE USED
WITH UL LISTED FAN MODELS
16” OR 24” ON CENTER
MOUNTING
BRACKET
FAN
DAMPER
NOTED.
FASTENER
GRILLE
GRILLE
SCREW
CEILING
WOOD
FRAMING
MEMBER
OR JOIST
GRILLE
CEILING
GRILLE SCREW