I
0
=
=
Fitting the Hose, Fitting the Air Seperator

Warning Light
Cause Solution
Dust caps still tted Remove the caps.
Blocked hose Unblock the hose.
Bag full Remove and replace
Cloth lter clogged Remove and replace, clean dirty lter by vacuuming.
Hepa cartridge clogged
Replace, seek advice from an instructed
person or manufacturer.
Slow Repeated Flash
This indicates that your lter bag has become full. Please change the bag.
If the fault persists check the following:-
Constant Red Light
This indicates a possible machine fault or that the auxiliary socket has become overloaded.
If the auxiliary socket is over loaded the machine will cut out.
Switch off the machine to reset.
If the fault remains check the fuse.