nubeca BW2110, BW2119, BW2219 Instruction Manual

VER:A00
Distributor:
Thanks for choosing the Digital Blood Pressure Monitor. Please read this instruction manual before using your unit. Please keep this instruction manual safe for future use.
Model No:BW2110
Fully Automatic Wrist Style
Digital Blood Pressure Monitor
Introduction ...............................................................................................1
Symbols Use .............................................................................................2
Important Safety Notes..............................................................................3
Konw Your Unit ......................................................................................4-5
IHB Introduction ........................................................................................6
Before Taking A Measurement ..................................................................7
Battery lnstallation/Replacement ............................................................8-9
Adjusting Settings ....................................................................................10
Proper Way of Measurement ...................................................................11
Take a Measurement ..........................................................................12-13
Use the Memory Function
To read the average value ...................................................................14
To read the measurement value ..........................................................15
To delete the memory value .................................................................16
About Blood Pressure
Blood Circulation ..................................................................................17
Health and Blood Pressure ..................................................................18
Classification of Blood Pressure .....................................................19-20
Before Using the Monitor
Care and Maintenance
Operating Instructions
Table of Contents
Exceptional Situations
Error Indicators ....................................................................................21
Eliminate Fault .....................................................................................22
Care and Maintenance
Care .....................................................................................................23
Maintenance ........................................................................................24
Specifications .....................................................................................25-26
Statement ................................................................................................27
Warranty Information ..........................................................................28-36
Table of Contents
2
Important Safety Notes
Read all information in the instruction manual and any other literature included in the box before using the unit.
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous.Follow the instructions of your healthcare provider.
Operate the unit only as intended. Don't use for any other purpose.
The unit is intended to use in measuring blood pressure and pulse rate for adult only, not recommended for neonatal baby at home or medical centre.
Do not use a cellular phone near the unit. It may result in operational failure.
Please avoid using in high radiant area in order to make your measuring data correctly.
Do not disassemble or attempt to repair the unit or components.
Do not use the equipment where flammable gas (such as anesthetic gas, oxygen or hydrogen) or flammable liquid (such as alcohol) are present.
To assure the correct use of the product basic safety measures should always be followed including the precautions listed below:
3
Symbols Use
Indicates a potentially hazardous situation
Type B applied part
Refer to instruction manual/booklet
MANUFACTURER
SERIAL NUMBER
The marking of electrical and electronics devices according to Directive 2002/96/EC. The device,accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal.
AUTHORISED REPRESENTATIVE IN THE EUROPEAN COMMUNITY
which, if not
avoided, could result in death or serious injury.
SYMBOLS USED IN THIS INSTRUCTION MANUAL
WARNING
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury to the user or
patient or damage to the equipment or other property.
1
Introduction
Thank you for purchasing Fully Automatic Wrist Style Digital Blood Pressure Monitor.
The unit uses the oscillometric method of blood pressure measurement. It means the unit detects the movement of your blood through your brachial artery, and converts your blood pressure into a digital reading. The unit is simple to use because a stethoscope is not needed while using an oscillometric monitor.
The unit stores automatically 60 sets of measurement values . You can read the stored data conveniently by pressing the memory button.
The unit comes with the following components:
• Main Unit
• Storage Case
• Instruction Manual printed in English
Body & Cuff
4
Know Your Unit
fWrist Cuf
Battery Compartment
Start/Stop Button Memory Button Memory Button
Display
Initialization
Initialization
Battery Installation / Replacement
1
Remove the battery cover from the battery compartment.
2
8
Install 2 “AAA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
2 AAAAlkaline Batteries
Power
Display
Storage Case
5
Know Your Unit
When the unit detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25% from the average rhythm or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the Irregular Heartbeat Symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
6
IHB Introduction
Normal Heartbeat
Irregular Heartbeat
Pulse
Blood
pressure
Pulse
Blood
pressure
Short Long
Irregular Heartbeat Symbol ( )
1.Avoid eating,drinking alcohol, smoking, exercising and bathing for 30 minutes before taking a measurement.
2.Stress raises blood pressure.Avoid taking measurements during stressful times.
3.The cuff can be applied to your left or right wrist.Always measure your blood pressure on the same wrist.
4.Measurements should be taken in a quiet place.
5.Position the unit at heart level throughout the measurement.
6.Remain still and do not talk during the measurement.
7.Keep a record of your blood pressure and pulse readings for your physician.A single measurement does not provide an accurate indication of your true blood pressure.You need to take and record several readings over a period of time.Try to measure your blood pressure at the same time each day for consistency.
8.Wait 30~60 seconds between measurements.The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement.You may need to increase the wait time depending on your individual physiological characteristics.
7
Before Taking A Measurement
Unit lndication
Systolic Blood Pressure
Diastolic Blood Pressure
Heartbeat Symbol
Pulse
Memory & Times
Irregular Heartbeat Symbol
Low Battery Symbol
Average Value Symbol
Inflation/Deflation Symbol or WHO Indication
Adjusting Settings
10
Replace the battery cover.
Caution!
3
Battery Installation / Replacement
9
Use two identical 1.5V alkaline batteries type AAA/LR03. Do not use rechargeable batteries. Replace both of the batteries if the symbol of low battery appears on the display.
Never leave any low battery in the battery compartment since they may leak and cause damage to the unit.
Press the “MEM” down button about 10 seconds unil the units (kPa or mmHg) displayed when the unit turned off. Then press the “MEM” up button to change the current unit. Press the “START/STOP” button to save the current setting and turn off.
11
Proper Way of Measurement
1
Wrap the cuff tightly around your wrist by using the Velcro strip.
2
Sit in a chair with your feet flat on the floor.
3
Remove all clothes from your arm allowing the cuff to fit directly on the skin.
Start to inflateDeflating automatically
All symbols display
Measurement starts while inflating.
2
The hearbeat symbol “ ” flashes once a pulse is detected.
To a fit pressure
Continue InflatingHeartbeat appearInflatingStart to inflate
All display symbols appear.
12
Take a Measurement
Press the “
START/STOP
” button.
1
1cm
(0.4'')
13
Take a Measurement
Press the “
START/STOP
” button to turn off the unit.
4
The cuff is deflated automatically, and the measurement results are stored in memory with date and time
The “ ” symbol will be displayed if irregular heartbeat is deteced.
The blood pressure and pulse rate are displayed when the measurement completed.
3
“kPa”display
“mmHg”display “ ”display
“ ”display
The unit will automatically turn off after two minutes if you have forgotten to turn it off.
NOTE: To stop the inflation or measurement, press the “
START/STOP
” button in anytime. The unit will
stop inflating and then release and turn off.
OR OR
The unit also calculates an average reading based on the values of the latest 3 times measurement taken.
Press the “MEM” up button, the average value of
the latest 3 times
measurement taken
of the current user will display with the average reading.
Use the Memory Function
14
To read the average value
...................................
the average value of the latest 3 times measurement taken
Turn to next
The unit stores the blood pressure and pulse rate in the memory after completing a measurement every time. It can automatically store 60 sets of measurement values . The oldest record is deleted to save the latest measurement value when more than 60 sets.
15
Use the Memory Function
..............................................
To read the measurement value
Press the “MEM” up button to display the set of measurement values.
Press the “MEM” down button to display the next set of measurement values.
After the measurement finished and when reading the memory values, the backlight is on about 10 seconds.
16
Use the Memory Function
To delete the memory value
..............................................
In the memory reading mode,
press
the “MEM” down button for 4-6 seconds, the unit
will display “ ”.
Press the “MEM” up button and confirm “ ” or “ ”.
If you are sure all the data of corresponding user can be deleted, press the “START/STOP” button, all the corresponding user’s data will be deleted and the unit will turn off.
Note: If you have set “ ”, but do not press a button for 2 minutes, the unit will turn off automatically, but the corresponding user’s blood pressure data will not be deleted. The delete operation must be confirmed by user.
The 1st latest measurement value
The 2nd latest measurement value
The 60th latest measurement value
Backward
Forward
17
About Blood Pressure
Lower pressure
Relaxation of the
heart muscle
Pressure decreased
to the blood vessel
Blood return heart
Higher pressure
Contraction of
the heart muscle
Pressure increased
to the blood vessel
Extrude blood
Diastolic Blood PressureSystolic Blood Pressure
Blood Circulation
The blood circulation is responsible for supplying the body with oxygen. blood pressure is the pressure exerted on the arteries. The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by contraction of the heart muscle. The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by relaxation of the heart muscle.
18
About Blood Pressure
The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat and high levels of cholesterol (LDL), which sticks to the inside in blood vessels, reduces elasticity of these vessels. Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction. For these reasons it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute, throughout the day. Therefore it is essential to take regular measurements to help you identify an average blood pressure.
19
About Blood Pressure
*Note!
When a person’s systolic and diastolic pressures fall into different categories, the higher category should apply.
WHO
80
85
90
100
110
Diastolic Blood Pressur (mmHg)
120 130 140 160 180
Systolic Blood Pressure (mmHg)
Optimal
blood pressure
(target value)
Normal blood pressure
Normal systolic value
Mild hypertension
Moderate hypertension
Severe hypertension
After each measurement is completed, the LCD display will show your position automatically on the six segments of the bar indicator which corresponds to World Health Organization (WHO) Blood Pressure Indicator.
Reference Material: Journal of Hypertension 1999, Vol 17 No.2
Classification of Blood Pressure
High blood pressure can go unnoticed for a long time, since it doesn’t cause noticeable symptoms. The following are all possible causes of abnormally high blood pressure: Overweight; High cholesterol level; Smoking; Excessive alcohol consumption; Stress and emotional upset; Excessive consumption of salt; Lack of physical exercise; Genetic / hereditary predisposition; Underlying illnesses, such as kidney disorders or endocrine disturbance.
If your blood pressure reaches upper values of 140~160 mmHg and lower values of 90~95 mmHg in repeated measurements over several days, you should consult your doctor for detailed medical examination. You can assist the treatment prescribed by your doctor in the following ways: Loose weight and lower your cholesterol level; Reduce the consumption of alcohol; Reduce the intake of salt; Stop smoking; Take regular exercise; Monitor your blood pressure.
20
About Blood Pressure
Classification of Blood Pressure
21
Exceptional Situations
Wrap the cuff correctly and tightly.
Inflate over again after ensuring.
Measure over again according to correct way.
Do not move your arm and body, and keep quiet.
When the batteries power are too low.
The course of inflating appears error.
When measurement fails.
Correction
CauseSymbol
Error Indicators
Replace both of the worn batteries with two new ones.
The following symbol will appear on the display when measuring abnormally.
22
Exceptional Situations
Blood pressure varies constantly. Many factors including stress, time of day, how you wrap the cuff, may affect your blood pressure. Review the sections "Proper Way of Measurement" and "Take a Measurement".
Check the battery installation for proper placement of the batteries polarities.
Measurement values appear too high or too low.
No display appears on the display screen.
No power.
Causes and Solutions
Problem
Eliminate Fault
Replace both of the worn batteries with two new ones.
23
Care and Maintenance
Care
Avoid subjecting the monitor to strong shocks or vibrations, such as dropping the nuit on the floor.
Use the unit consistent with the instructions provided in this manual. Use only authorized parts and accessories.
Keep the unit in the storage case when not in use.
Clean the unit with a soft dry cloth. Do not use any abrasive or volatile cleaners.
Never immerse the unit or any components in water.
Store the unit in a clean and dry location. Do not subject the unit to extreme hot or cold temperature, humidity and direct sunlight.
Maintenance
24
Care and Maintenance
naphtha
thinner
gasoline
Remove the batteries if the unit will not be used for 3 monthes or longer. Always replace both of the batteries with new ones at the same time.
Do not wet the cuff or attempt to clean the cuff with water.
Do not clean the body and cuff with naphtha, thinner or gasoline etc.
60 Sets Measurement Values
25
Specifications
BW2110
LCD Digital Display
Oscillometric Method
Measurable
Model No.
Display
Measuring Principle
Circumference of Wrist
13.5~21.5cm
(5.3''~8.5'')
Electric Shock
Protection
Measurement Range
Accuracy
Pressure
Pulse
Pressure
Pulse
Pressure
0 to 299 mmHg (0~39.9 kPa)
40 to180 Pulses/min
3 Digits Display of mmHg or kPa
3 Digits Display
Memory/IHB/Heartbeat/Low Battery,etc.
3 mmHg (0.4kPa)
5% of reading
Pulse
Internal power supply appliance type B
LCD Indication
Symbol
26
Specifications
10 ~ 40 C (50 ~ 104 F)
15 ~ 90%RH (Noncondensing)
-20 ~ 60 C (-4 ~ 140 F)
10 ~ 95%RH (Noncondensing)
Temperature
Humidity
Temperature
Humidity
Barometric Pressure
Automatic by Internal Pump
Automatic by Air Valve
In 2 Minutes
Approx. 87*84*36mm
Operating Environment
Memory Function
Inflation
Power Source
Rapid Air Release
Automatic Power-Off
Dimensions
Approx. 110g (Batteries not included)
Gross Weight
80~105 kPa
2 AAA Alkaline Batteries
28
27
Warranty Information
Federal law restricts this device to sale by or on the order of a physician.
Unit subjected to misuse, abuse, and neglect of these manual contents, non-instructional purposes;unauthorized repair or modifications will be excluded from this warranty. This guarantee specifically excludes expendables and consumables, for example batteries.All warranty claims must be directed to the distributor responsible for the sale of the device. The content of this warranty is subject to change without further notice.
For repair under this warranty.Our authorized service agent must be advised of the fault within the period of the warranty.This warranty covers parts and labor only under normal operations.A transportation fee or freight fee that may be incurred will be the owner’s responsibility.Any defect resulting from natural causes, e.g.,flood,hurricane etc., is
not within this guarantee. This guarantee does not cover damage incurred by use of the unit not in accordance with the instructions, accidental damage, or being tampered with or serviced by unauthorized service agents.
The unit, excluding the unit cuff, is guaranteed to be free of defects in workmanship and materials for a period of two years from the date listed on the purchase record, when used in accordance with the instructions provided with the unit.The unit cuff is warranted to be free from defects in materials and workmanship appearing within one year from the date listed on the purchase record when the unit is used in accordance with the instructions provided with the unit.
Statement
The intended use: The unit is intended to be used by adults at home or medical centre to measure blood pressure and pulse rate.
The unit satisfies the requirements of IEC60601-1 Medical electrical equipment, EN1060-1: Non-invasive sphygmomanometer, EN1060-3: Non-invasive sphygmomanometer,IEC80601-2-30: Medical electrical equipment.
The unit has passed the EMC Test.
Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultatory method, within the limits prescribed by the American National Standard, Manual, electronic, or automated sphygmomanometers.
The risk of patient and user can be lowered to acceptable level.
Substitution of a cuff different from that supplied might result in measurement error.
Please contact us if you need the circuit diagrams, component part lists etc.
Specifications are subject to change without notice due to improvements in performance.
Transport and Storage Environment
29
Warranty Information
Periodical check: Sensitive measuring devices must be checked from time to time for accuracy and leakage, we therefore recommend that the performance should be checked every 2 years and after maintenance and repair.
Please contact the local distributor for details.
The unit satisfies the requirements of EN60601-1 Medical electrical
equipment Part 1: General requirements for basic safety and essential
performance; EN60601-1-2: Medical electrical equipment Part 1-2:General
requirements for basic safety and essential performance – Collateral standard:
Electromagnetic compatibility – Requirements and tests;
EN1060-1:Non-invasive sphygmomanometers – Part 1: General requirements;
EN1060-3: Non-invasive sphygmomanometers – Part 3: Supplementary
requirements for electro-mechanical blood pressure measuring system.
EN1060-4Non-invasive sphygmomanometers – Part 4: Test procedures
to determine the overall system accuracy of automated non-invasive
sphygmomanometers.
Warning: Do not use luer lock connector in the construction of tubing. There
Is a possibility that they might be inadvertently connected to intravascular fluid
systems, allowing air to be pumped into a blood vessel.
30
Warranty Information
It can’t be used while the wrist (arm) has bleeding or wound to avoid the blood
flowing from the wound in pressurizing.
It can’t be used while the wrist (arm) has bleeding or wound to avoid the blood
flowing from the wound in pressurizing.
WARNING: No modification of this equipment is allowed.
Clean the cuff with a soft dry cloth.
Applied parts contains cuff. The deviceaccessories and the packaging have to be disposed of waste
correctly at the end of the usage. Please follow Local Ordinances or
Regulations for disposal.
Protection Class: Internally powered equipment Applied Part Type: Type B Moisture Protection: IPX0, continue operation
Manufacturer will make available on request circuit diagrams, component part lists etc for the service personnel in parts repair.
32
Guidance and manufacture’s declaration – electromagnetic emission
Emission test
RF emission
Harmonic
Voltage
Group 1
Class B
Not applicable
Not applicable
The Digital Blood Pressure Monitor use RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.
The Digital Blood Pressure Monitor is suitable for use in all establishments other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.
CISPR 11
RF emissions
emissions
fluctuations/
flicker emissions
IEC 61000-3-3
IEC 61000-3-2
CISPR 11
Compliance
Electromagnetic environment – guidance
The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer of the user of the Digital Blood Pressure Monitor should assure that it is used in such an environment.
31
Warranty Information
Guidance and manufacture’s declaration
Caution: this machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used. *MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS. *Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT. * Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.
Caution: This unit has been thoroughly tested and inspected to assure proper performance and operation!
WARNING: The use of ACCESSORIES, transducers and cables other than those specified, with the exception of transducers and cables sold by the MANUFACTURER of the COMPRESSOR NEBULIZER as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the ME EQUIPMENT or ME SYSTEM.
Warranty Information
33
Warranty Information
34
Warranty Information
Guidance and manufacture’s declaration – electromagnetic immunity
Immunity test
Power frequency
magnetic field IEC
61000-4-8
±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
3A/m 3A/m
Floors should be wood, concrete or ceramic tile. If floor are covered with synthetic material, the relative humidity should be at least 30%.
Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
(50Hz/60Hz)
Electrostatic
IEC 61000-4-2
discharge (ESD)
IEC 60601 test
Compliance
level level
Electromagnetic environment - guidance
The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of Digital Blood Pressure Monitor should assure that it is used in such an environment.
NOTE UT is the a.c. mains voltage prior to application of the test level.
Guidance and manufacture’s declaration – electromagnetic immunity
Immunity test
80 MHz to 2.5
GHz
3A/m
3A/m
80 MHz to 800 MHz 800 MHz to 2.5 GHz
Portable and mobile RF communications equipment should be used no closer to any part of the Digital Blood Pressure Monitor, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site
Radiated RF
IEC 61000-4-3
IEC 60601 test
Compliance
level level
Electromagnetic environment - guidance
Recommended separation distance
The Digital Blood Pressure Monitor is intended for use in the electromagnetic environment specified below. The customer or the user of Digital Blood Pressure Monitor should assure that it is used in such an environment.
35
Immunity test
80 MHz to 2.5
GHz
3A/m
3A/m
survey,a should be less than the compliance level in each frequency range.
b Interference may occur in the vicinity of equipment marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Digital Blood Pressure Monitor is used exceeds the applicable RF compliance level above, the Digital Blood Pressure Monitor should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Digital Blood Pressure Monitor.
Radiated RF
IEC 61000-4-3
IEC 60601 test
Compliance
level level
Electromagnetic environment - guidance
Warranty Information
36
Recommended separation distances between portable and mobile RF communications equipment and the Digital Blood Pressure Monitor.
output power of transmitter
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
Separation distance
(m)
according to frequency of transmitter
Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the Digital Blood Pressure Monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Digital Blood Pressure Monitor as recommended below, according to the maximum output power of the communications equipment.
Warranty Information
80 MHz to 800 MHz
0.01
0.1 1
10
100
0.117 0.233
0.369 0.738
1.167 2.333
3.689 7.379
11.667 23.333
80 MHz to 800 MHz
Loading...