MiCard V3 Installation Manual (Full
Install Guide)
MiCard V3 - Installation Manual
MiCard_V3_Full_Installation_Guide_EN_V1.0.pdf
uniFLOW Login Manager/MomClient (Secure/Public Printing Applet)
This manual describes the features, the installation, and the configuration of the MiCard V3 Reader
in detail.
MiCard is a registered trademark of NT-ware Systemprogrammierung GmbH.
Versioning
Disclaimer
All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, or
mechanical, including photocopying, recording, taping, or information storage and retrieval systems - without the
written permission of NT-ware Systemprogrammierung GmbH.
Company and product names mentioned herein are registered or unregistered trademarks of their respective
companies. Mention of third-party products is for information purposes only and constitutes neither an endorsement
nor a recommendation. NT-ware assumes no responsibility with regard to the performance or use of these products.
Also, NT-ware makes no claim to these trademarks. Any use of trademarks, logo, service marks, trade names, and
product names is prohibited without the written permission of the respective owners.
Adlib Software of Adlib Software; Adobe®, Adobe® Reader, Acrobat®, Distiller®, PostScript® and products of the
CREATIVE SUITE(S) of Adobe Systems Incorporated; Apple®, the Apple® logo, Mac®, Mac OS®, Macintosh®, iPhone®,
iPad® and AirPrint® of Apple Inc.; CANON, imageRUNNER, imageRUNNER ADVANCE, MEAP, CPCA, AMS, iW AMS, iW
Desktop, iSend, iW SAM of Canon Inc.; Crystal Reports of Business Objects SA, as of July 1, 2008: BusinessObjects of
SAP; eCopy™, eCopy ShareScan®, and eCopy ScanStation® of Nuance Communications, Inc.; Foxit Reader of Foxit
Corporation; Google Docs of Google Inc.; Helix™ Production Workflow is a trademark of NT-ware
Systemprogrammierung GmbH; Hewlett Packard, HP, LaserJet, and PCL of Hewlett-Packard Company; iOS® of Cisco
Technology Inc.; I.R.I.S. Group s.a.; JAWS pdf courier™ are trademarks of Global Graphics SA.; Microsoft®, Windows®,
Windows Vista®, Windows 7®, Internet Explorer®, Internet Information Server, Microsoft® Word, Microsoft® Excel,
SQL Server® of Microsoft Corporation; Neevia Document Converter ProTM of Neevia Technology; NetWare, Novell®,
Novell eDirectory® of Novell Inc.; OpenOffice.org™ of Oracle Corporation; PAS™ of Equitrac Corporation; PosterJet of
Eisfeld Datentechnik GmbH & Co. KG; Red Titan EscapeE of Red Titan Limited; NETAPHOR ®, SiteAudit™ are
trademarks of NETAPHOR SOFTWARE Inc.; Therefore™ of Therefore; UNIX® of The Open Group; uniFLOW OM®,
uniFLOW®, uniFLOW Serverless Secure Printing®, MIND®, microMIND®, and MiCard® are registered trademarks of
NT-ware Systemprogrammierung GmbH; pcProx®, AIR ID® are registered trademarks of RFIdeas Inc.Readers;
CASI-RUSCO® is registered trademark of ID Card Group; Radio Key® is registered trademark of Secura Key; GProx™ II is
unregistered trademark of Guardall; HID® ProxHID is registered trademark of HID Global Corporation; Indala® is
registered trademark of Motorola; ioProx™ is unregistered trademark of Kantech.
All other trademarks, trade names, product names, service marks are property of their respective owners and are
hereby acknowledged.
While every precaution has been taken in the preparation of this document, NT-ware assumes no responsibility for
errors or omissions, or for damages resulting from the use of information contained in this document or from the use
of programs and source code that may accompany it. NT-ware does not assume any responsibility or liability for any
malfunctions or loss of data caused by the combination of at least of one NT-ware product and the used operation
system and/or third-party products. In no event shall NT-ware be liable for any loss of profit or any other commercial
damage caused or alleged to have been caused directly or indirectly by this document.
In addition, this manual provides links to the sites of affiliated or independent companies and certain other
businesses. NT-ware is not responsible for examining or evaluating, and NT-ware does not warrant the offerings of,
any of these businesses or individuals or the content of their websites. NT-ware does not assume any responsibility or
liability for the actions, product, and content of all these and any other third parties. You should carefully review their
privacy statements and other conditions of use.
PLEASE NOTE: Serious problems might occur if you modify the registry of your Windows operating system incorrectly.
These problems might require that you reinstall the operating system. We strongly recommend to always back up the
registry of your Windows operating system before applying changes to it, just in case you do something wrong.
NT-ware does not assume any responsibility or liability for any impact on the operating system after changing the
Registry. You understand and accept that you use this information and modify the registry of your Windows operating
system at your own risk.
Friday, October 26, 2012, Bad Iburg (Germany)
Important note: Information that is crucial for the correct functioning of the uniFLOW
software.
External manual: Pointer to additional manuals for third party hardware or third party
software.
Region Specific Feature: In case some features of uniFLOW are not universally
available, this icon will indicate it.
Link to an external reference within the WWW.
Detailed explanation of configuration settings or operational procedures.
Symbols
Text Styles
Text that appears in this style is used for screen text that appears in the uniFLOW user interface and on
user interface controls.
Text that appears in this style is used for User entries on screen, text that the user actually has to type in.
Text that appears in this style is used for hyperlinks to an external web page, or internal links to other pages
of this manual.
Text that appears in this style is used for code examples: XML code, variables or
regular expressions.
Pictograms
Copyright and Contact
©1998-2012 NT-ware Systemprogrammierung GmbH.
In case of errors or improvement suggestions please contact documentation@nt-ware.com.
MiCard V3 Installation Manual (Full Install Guide) Contents
Contents
1 MiCard V3 contactless card reader ............................................................. 2
1.1 Scope of supply ............................................................................................................. 2
1.2 Requirements ............................................................................................................... 2
1.3 FCC and IC Compliance Note .......................................................................................... 4
1.4 Supported Card Standards............................................................................................. 4
1.5 System Setup ................................................................................................................ 4
1.6 Installation of the MiCard V3 on the imageRUNNER ADVANCE ...................................... 5
1.7 LED Status ..................................................................................................................... 9
1.8 Beep Status ................................................................................................................... 9
2 Configuration ........................................................................................... 10
2.1 Upgrading from SSP to uniFLOM OM V4.1 or uniFLOW V5.0 ........................................ 13
3 MiCard V3 Configuration on the uniFLOW Server ..................................... 13
3.1 Global MiCard V3 Configuration .................................................................................. 14
3.1.1 Configuration - General ..................................................................................................................... 14
3.1.2 Configuration - Multi ......................................................................................................................... 15
3.1.3 Device Specific MiCard V3 Configuration .......................................................................................... 16
4 Index ........................................................................................................ 19
I
MiCard V3 Installation Manual (Full Install Guide)
1 MiCard V3 contactless card reader
MiCard V3 provides an easy to use, easy to install and cost effective solution for user
identification with a contactless card alongside your Canon iR and Canon
imageRUNNER ADVANCE. With MiCard V3 users can be identified by simply waving
their card over the reader. After identification the device unlocks and you are able to
make your copies or pick up your secure print jobs.
Installation and configuration has never been easier. You simply connect the MiCard
V3 directly to the device via USB. Even power is supplied via USB, thus providing a cost
effective solution by removing expenses normally required for an additional interface.
After connecting MiCard V3 to the device, it will automatically be recognized and
configured by the uniFLOW MEAP application, which has been integrated with the
device.
There are many different technologies for Radio Frequency Identification (RFID) on the
market. For additional flexibility, the MiCard V3 contactless card reader is available in a
number of different versions, all supporting different RFID frequencies and
technologies.
MiCard V3 Multi
The uniFLOW MEAP application embedded in the device will also make your life in the
office much easier. You can use it for printing confidential information securely. Simply
select the print job you want to print directly from the control panel of the device, with
no risk of being intercepted by anyone else.
Additionally, it can be used for charging copy jobs back to specific cost centers,
departments or customers, printing of general/internal company documents, or for
cross-authentication into other applications, like eCopy for example.
1.1 Scope of supply
The MiCard V3 reader package includes
the MiCard V3 reader unit
a short USB cable for the installation in an imageRUNNER ADVANCE (please refer
to chapter Installation of the MiCard V3 on the imageRUNNER ADVANCE (on page
5))
a longer cable to connect the reader unit to another imageRUNNER
a pull relief
adhesive tape
a Quick-Install Guide
1.2 Requirements
2