NTi Audio NetBox Datasheet

PRODUCT DATA
NetBox
for XL2 Sound Level Meter
The NetBox connects the XL2 Sound Level Meter to the in­ternet for unattended noise monitoring. It transfers the mea­surement data to the fully-managed NoiseScout Web Portal in real time or provides a secure access to the instrument via the NTi Audio Gateway.
The NoiseScout solution brings your XL2 noise measurement data to your web browser. The NetBox retrieves the noise levels from the XL2 and forwards them via 3G, 4G, 5G, LAN or WLAN to the NoiseScout servers (4G/5G using an external modem). All mea­surement levels are available online for live visualization and unat­tended monitoring with email alerts.
NetBox with 3G Modem
for unattended noise monitoring
with the XL2 Sound Level Meter
Key Features
Secure 24/7 noise monitoring •
Communication 3G, 4G, 5G, LAN or WLAN•
NoiseScout provides automatic email alerts•
Remote noise data collection (SFTP)•
Plug-and-play solution•
Applications
Base-line surveys for planning•
Construction site monitoring•
Live Noise Monitoring
on the NoiseScout Web Portal with
XL2 Sound Level Meter and NetBox
www.nti-audio.com
Road traffic noise monitoring•
Entertainment venue management•
Neighborhood noise pollution measurements•
Environmental & Community Noise Surveys•
Nov 20, Page 1 / 9
Specifications
PRODUCT DATA
NoiseScout offers automated
email alerts when noise limits are ex-
ceeded
Online Communication NetBox (LAN & WLAN)•
Additional Interfaces 4 x USB port•
Connections to XL2 USB interface•
Data Day Credits Required for the online data transmission•
NoiseScout ­Managed Mode
NoiseScout ­Gateway Mode
LAN ­WLAN -
NetBox with 3G Modem, LAN & WLAN•
3G ( - SIM card slot provided) 4G/5G using an external modem ­LAN ­WLAN -
Auxiliary inputs/outputs (prepared for future use)• SD Card slot for service•
Power supply (top-head rail connector)•
Includes 10 Data Day Credits• Data Day Credits apply to a single user account. • Credits may be shared among multiple XL2s.•
Transfers measurement data and limit alerts from XL2 • to NoiseScout server Requires NoiseScout 365 or Data Credits Package for • pay-per-use: One Data Day Credit is debited for each calendar day on which data was download. Mobile Data Volume Expected Usage < 3 GB / month•
Remote access to all measurement data• Full remote control of XL2 Sound Level Meter• Requires NoiseScout 365 or Data Credits Package for • pay-per-use: One Data Day Credit is debited for each calendar day on which data was download. Mobile Data Volume Expected Usage•
Status (Bitmap): 200 MB / hour for each viewer ­XL View: 1 MB / hour for each viewer -
Monitoring Features NetBox supply voltage •
LED Indications Power: power supply active•
Power Supply 7.5 -16 VDC•
Frequency Bands NetBox with 3G-Modem and LAN supports
Temperature range –10 ºC to +50 ºC (14 °F to 122 °F)
Humidity range 5 % to 90 % RH, non-condensing
Dimensions L x W x H 138 x 138 x 30 mm (5.4” x 5.4” x 1.2”)
Weight 290 g (10.2 oz.)
Scope of Supply with Netbox
Communication signal strength and type• Ambient temperature•
XL2: connected with XL2• Server: connected with NoiseScout server • Data: data transmitting in process•
Power consumption •
NetBox typical 3 Watt ­XL2+NetBox typical 6 Watt -
GSM / GPRS / EDGE: 850 / 900 / 1800 / 1900 MHz• UMTS / HSPA: 850 / 900 / 1700 / 1900 / 2100 MHz•
10 Data Day Credits• Mains power adapter 12 V, 2.0 A, 100-240 V• Power cable to XL2• Optional: integrated 3G Modem with external antenna • (SMA connector)
www.nti-audio.com
Page 2 / 9
PRODUCT DATA
Order Information NetBox (LAN) 600 000 450•
All information subject to change without notice.
NetBox with 3G Modem and LAN 600 000 458• NoiseScout 365 600 000 437 • or Data Credits
30 Days 600 000 490 ­100 Days 600 000 491 ­366 Days (1 year) 600 000 492 ­1096 Days (3 years) 600 000 493 -
www.nti-audio.com
Page 3 / 9
PRODUCT DATA
Battery Power Supply
Situation•
mains power only optional available -
external battery pack(s) power the noise monitor station -
Solution •
external battery pack(s) power the NetBox ­optional are the battery packs connected to an individual char­ger
power supply is looped through the NetBox to the XL2 Sound ­Level Meter
What happens upon Battery Pack is down•
noise measurement is stopped (in case of used inernal XL2 bat- ­tery after 4 hours); XL2 powers down
(charger)
all measurement data recorded prior the power outage is saved ­on the meter
NetBox is powered off; no remote monitoring or data communi- ­cation is possible
NoiseScout - Managed Modus•
customer can be automaticaly informed by email about the ­power loss for immediate action
Note•
in case of Tracer battery packs are used, then utilize the acces- ­sory “Tracer Adapter Cable”, NTi Audio # 600 000 478
the Tracer Adapter Cable supports the auto-start of the NetBox ­or XL2 upon the battery was completely empty and is charged again; the power supply will be connected to the NetBox or XL2 via a relay only upon a minimum charge condition is reached.
Battery
(charger)
www.nti-audio.com
Battery
XL2NetBox
Configuration 2: Battery Power Supply
Page 4 / 9
PRODUCT DATA
Setup and Power Supply Configurations
This part describes the recommended setup and power supply con­figurations of the NoiseScout measurement station for short-term and long-term noise monitoring applications.
The internal XL2 battery can’t be continiously charged by an external power supply for long-term applications. Therefore either replace the internal XL2 battery in annual intervals or operate the measurement station without the internal XL2 battery.
The manufacturer guidelines of the solar controller has to be followed. High electrical currents may be appli­cable. Select connection the cable type accordingly.
Mains Power
Situation•
mains power available -
no back up for mains power interruptions -
Solution•
default mains adapter (12V) supplies NetBox -
power supply is looped through the NetBox to the XL2 Sound ­Level Meter
What happens upon Mains Power Loss•
noise measurement is stopped (in case of used inernal XL2 bat- ­tery after 4 hours); XL2 powers down
all measurement data recorded prior the power outage is saved ­on the meter
NetBox is powered off; no remote monitoring or data communi- ­cation is possible
NoiseScout - Managed Modus•
mains adapter
www.nti-audio.com
customer can be automaticaly informed by email about the ­power loss for immediate action
XL2NetBox
Configuration 1: Mains Power
Page 5 / 9
PRODUCT DATA
Mains Power Supply with Battery Backup
Situation•
mains power available -
external battery pack(s) serve as back up -
Solution•
default mains adapter (12V) supplies NetBox -
power supply is looped through the NetBox to the XL2 Sound ­Level Meter
external battery packs are connected for back up in case of ­mains power drops out (a charger is connected as applicable)
What happens upon Mains Power Loss•
external battery pack(s) power XL2 Sound Level Meter -
(charger)
noise measurement is continued as long as XL2 is powered by ­the external and internal battery
all measurement data is saved on the XL2; no data is lost -
NetBox is powered off; no remote monitoring or data communi- ­cation is possible
NoiseScout - Managed Modus•
customer can be automaticaly informed about mains power ­loss by email
the measurement data of the last 7 days is available on the me- ­ter - power up the NetBox again within latest 6 days to ensure continious measurement data
(charger)
mains adapter
www.nti-audio.com
Battery
Configuration 3: Mains Power Supply with Battery Backup
Battery
XL2NetBox
Page 6 / 9
Solar Power
Situation•
no mains power available -
solar panel powers the noise monitor station -
Solution •
external battery pack supplies NetBox -
power supply is looped through the NetBox to the XL2 Sound ­Level Meter
solar controller charges battery pack from the solar panel -
What happens upon Battery Pack is down•
noise measurement is stopped (in case of used inernal XL2 bat- ­tery after 4 hours); XL2 powers down
PRODUCT DATA
all measurement data recorded prior the power outage is saved ­on the meter
NetBox is powered off; no remote monitoring or data communi- ­cation is possible
NoiseScout - Managed Modus•
customer can be automaticaly informed by email about the test ­station power loss for immediate action
www.nti-audio.com
Solar­panel
Solar-
controller
Battery
XL2NetBox
Configuration 4: Solar Power
Page 7 / 9
PRODUCT DATA
Mains Power Supply with Solar Backup of Test Station
Situation•
mains power available -
solar panel serves as backup power for the noise monitor sta- ­tion
Solution •
default mains adapter (12V) supplies NetBox -
power supply is looped through the NetBox to the XL2 Sound ­Level Meter
solar controller is connected for back up in case of mains power ­drops out and charges battery from the solar panel
What happens upon Mains Power Loss•
battery pack powers NetBox and XL2 Sound Level Meter -
noise measurement is continued as long as XL2 is powered by ­the external and internal battery
all measurement data is saved on the XL2; no data is lost -
NetBox is powered on; remote monitoring or data communica- ­tion is possible
NoiseScout - Managed Modus•
customer can be automaticaly informed by email about the test ­station power loss for immediate action
mains adapter
www.nti-audio.com
Solar­panel
Solar-
controller
Battery
NetBox
Configuration 5: Mains Power Supply with Solar Backup of Test Station
XL2
Page 8 / 9
Mains Power Supply with Solar Backup of XL2
Situation•
mains power available -
solar panel serves as backup power for the noise monitor sta- ­tion
Solution •
default mains adapter (12V) supplies NetBox -
power supply is looped through the NetBox to the XL2 Sound ­Level Meter
solar controller is connected for back up in case of mains power ­drops out and charges battery from the solar panel
What happens upon Mains Power Loss•
PRODUCT DATA
battery pack powers XL2 Sound Level Meter -
noise measurement is continued as long as XL2 is powered by ­the external and internal battery
all measurement data is saved on the XL2; no data is lost -
NetBox is powered off; no remote monitoring or data communi- ­cation is possible
NoiseScout - Managed Modus•
customer can be automaticaly informed by email about the ­mains power loss for immediate action; the XL2 continiues the measurement
mains adapter
www.nti-audio.com
NetBox
Solar­panel
Configuration 6: Mains Power Supply with Solar Backup of XL2
Solar-
controller
Battery
XL2
Page 9 / 9