The material in this guide is for information only and is subject to change without notice. Network Technologies Inc reserves the
right to make changes in the product design without reservation and without notification to its users.
Note: Shielded
CAT 5,5e, or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission
and immunity requirements.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products
should not be run underground, outdoors or between buildings.
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
CE Statement
We, Network Technologies Inc, declare under our sole responsibility that the ST-C5KVM-600(M), STC5KVMRS-600(M),
STC5VMA-600(M), ST-C5V-600(M), STC5VRS-600(M), ST-C5VA-600(M), ST-C5SV-600, and ST-C5SVA-600 is in conformity
with European Standard EN55022.
Federal Communications Commission Radio Frequency Interference Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference and
(2) this device must accept any interference received, including interference that might cause undesired operation.
This device complies with Part 15 of the FCC rules. This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment.
Warning: This equipment generates, uses and can radiate radio frequency energy, and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Features and Functions................................................................................................................................................... 4
Preparation for Installation ..............................................................................................................................................6
Installing The Local Unit (models with VGA video connectors).................................................................................. 7
Installing The Local Unit (models with S-Video connectors) ......................................................................................9
Installing the Local Unit (models with only KM connectors) ......................................................................................10
Connect The CAT5 Cable.......................................................................................................................................... 11
Installing The Remote Unit (models with VGA video connectors)............................................................................. 11
Installing The Remote Unit (models with S-Video connectors) ................................................................................. 13
Installing The Remote Unit (models with only KM connectors) .................................................................................14
Connect the CAT5 cable............................................................................................................................................ 14
Plug-in and Boot Up................................................................................................................................................... 15
Mount the ST-C5RCK-12 Rackmount Extender Module Tray................................................................................ 16
Connect the CPU .................................................................................................................................................... 18
Connect the Devices............................................................................................................................................... 19
Connect the CAT5 cable......................................................................................................................................... 20
Plug-in and Boot Up................................................................................................................................................... 21
Video Quality .................................................................................................................................................................22
Figure 1- Connect the Local Unit with VGA video and RS232 support to the CPU............................................................................ 7
Figure 2- Connect the Local Unit with Audio support to the CPU ......................................................................................................8
Figure 3- Connect the local user to the XTENDEX Local Unit ...........................................................................................................8
Figure 4- Connect stereo speakers to XTENDEX Local Unit with audio support............................................................................... 9
Figure 5- Connect the S-Video Local Unit to the s-video/audio source.............................................................................................. 9
Figure 6- Connect S-Video display and speakers to Local Unit with s-video support ......................................................................10
Figure 7- Connect Local Unit with only keyboard and mouse support ............................................................................................. 10
Figure 8- Connect CAT5 cable to Local Unit.................................................................................................................................... 11
Figure 9- Connect the Extended Components to the Remote Unit .................................................................................................. 12
Figure 10- Connect speakers to the Remote Unit ............................................................................................................................ 12
Figure 11- Connect components to an S-Video Remote Unit ..........................................................................................................13
Figure 12- Connect keyboard and mouse to Remote Unit ............................................................................................................... 14
Figure 13- Connect the CAT5 cable to the Remote Unit.................................................................................................................. 14
Figure 14- Connect the AC adapter to the Remote Unit ..................................................................................................................15
Figure 15- Mount ST-C5RCK-12 Extender Module Tray in a rack...................................................................................................16
Figure 16- Secure each module to the tray...................................................................................................................................... 16
Figure 17- Secure each power supply to the tray ............................................................................................................................17
Figure 18- Connect cable between CPU and module...................................................................................................................... 18
Figure 19- Connect cable between user and module ......................................................................................................................19
Figure 20- Connect the CAT5 cable between the Local and Remote Units ..................................................................................... 20
Figure 21- Connect AC adapters ..................................................................................................................................................... 21
Figure 22- Buttons for video quality adjustment............................................................................................................................... 22
Figure 23- View looking into RJ45 female........................................................................................................................................ 24
ii
Page 4
NTI XTENDEX 600 Foot Extenders
INTRODUCTION
The XTENDEX Series CAT5 Extender (XTENDEX) is designed to enable one CPU to be controlled by two users, one local and
one remote. The remote user can be located as much as 600 feet away from a PS/2 CPU via Category 5 unshielded twistedpair cable. The local user will be located near the CPU.
Option:
Rackmount Modules- The XTENDEX Series CAT5 Extenders can be ordered as rackmount modules (Remote and/or Local
Units)- add “M” to the model number (i.e. ST-C5KVM-600M). When ordering rackmount modules, also order the ST-C5RCK-12
Rackmount Extender Module Tray (see page 16).
The XTENDEX Series Extender is extremely simple to install and has been thoroughly tested to insure reliable performance.
Through the use of Category 5 cable it is possible to economically increase the flexibility of a computer system. Here are some of
the features and ways this can benefit any workplace:
• Allows the placement of computer peripherals (monitor, keyboard, and mouse) in a location where
only these parts are needed without having the CPU there too, taking up valuable space
• Allows a PS/2 CPU to be accessed by both a local and remote user (up to 600 feet away)
• Compatible with XGA, VGA, and SVGA systems
• Provides crisp and clear resolution up to 1024 x 768 @ 600 feet (see page 21 for more details)
• Compatible with all NTI switches and splitters, enabling the joining of products to create a system that
satisfies all networking needs
• Video quality adjustment, for varying lengths of cable, is automatic (most models, see below and
page 20) providing optimum image quality
• Audio frequency response is 20Hz to 20Khz, +
• Digital transmission of audio signals reduces any loss in quality (models with audio support only)
This manual covers each of the XTENDEX Series CAT5-600 Extender models offered. Some features described in this manual
are available in some models and not in others. The chart below shows the features supported in each:
Note: Rackmount modules are not available with S-Video support
VGA Yes No No Automatic
VGA Yes Yes No Automatic
VGA Yes No Yes Automatic
VGA No No No Manual
VGA No Yes No Automatic
VGA No No Yes Automatic
S-Video No No No Manual
S-Video No Yes (RCA) No Automatic
VGA Yes No Yes Manual
NO Remote only No No Not Applicable
Support
1Db (models with audio support only)
Audio
Support
RS232
Support
1
Video Quality
Adjustment
Page 5
NTI XTENDEX 600 Foot Extenders
MATERIALS
Materials Included with this kit:
9 NTI XTENDEX Local Unit
9 NTI XTENDEX Remote Unit
9 2- 120VAC or 240VAC at 50 or 60Hz-9VDC/1.0A AC Adapters (only 1 ST-C5KM-600)
9 CD with a pdf file of this owner's manual
Additional materials may need to be ordered, depending upon the configuration:
¾ CAT5/5e/6 unshielded twisted-pair cable(s) terminated with RJ45 connectors wired straight thru- pin 1 to pin 1, etc. (see pg.
8 for proper EIA/TIA 568 B wiring method)
Note: Shielded
requirements.
¾ Cable(s) needed if Local Unit will be located further than 15" from the CPU
Model Cable(s) needed
ST-C5KVM-600 VKMEXT-xx (xx= 3/6/10/15/25/35/50/75/100 feet)
ST-C5KVMRS-600 VKMEXT-xx and DINT-xx
ST-C5KVMA-600 VKMEXT-xx and SA-xx-MF
ST-C5V-600 VEXT-xx
ST-C5VRS-600 VEXT-xx and DINT-xx
ST-C5VA-600 VEXT-xx and SA-xx-MF
ST-C5SV-600 SVEXT-xx
ST-C5SVA-600 SVEXT-xx and SA-xx-MF
ST-C5KM-600 VVKINT-xx or VVKEXT-xx
For Rackmount Modules the following materials are required- not supplied
Model
ST-C5KVM-600M VMCTINT-xx-MM and VMCTINT-xx
ST-C5KVMRS-600M VMRSTINT-xx-MM and VMRSTINT-xx
ST-C5KVMA-600M VMATINT-xx-MM and VMATINT-xx
ST-C5V-600M VTINT-xx-MM and VTINT-xx
ST-C5VRS-600M VRSTINT-xx-MM and VRSTINT-xx
ST-C5VA-600M VATINT-xx-MM and VATINT-xx
Legend:
xx= 3, 6, 10, 15 or 25 foot length
MM= cables have male connectors on both ends (except for the DB9) and are only used with Local Units
Note: If two users will be connected (one local and one remote), two of the cables without the “MM”
(i.e. VMCTINT-xx) will be needed.
Contact your nearest NTI distributor or NTI directly for all of your KVM needs at 800-RGB-TECH (800-742-8324) in US & Canada
or 330-562-7070 (Worldwide) or at our website at http://www.networktechinc.com and we will be happy to be of assistance.
CAT 5,5e, or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission
:
Cables needed
2
Page 6
NTI XTENDEX 600 Foot Extenders
8a910
11a
8a910
11b
8b11c
11d
6
7
(Front View)(Rear View)
6
7
6
7
FEATURES AND FUNCTIONS
2
5a
NTI
Network T echnolo gies Inc
XTENDEX
+
-
R
15
ST-C5KVMRS-600 Local Unit
5b
NTI
Network Technologies Inc
XTENDEX
+
-
R
15
(Front View)(Rear View)
ST-C5KVMA-600 Local Unit
15
NTI
Network T echnolo gies Inc
XTENDEX
5b
+
-
R
(Front View)(Rear View)
ST-C5SVA-600 Local Unit
R
NTI
Network Tech nologies Inc
XTENDEX
1
3
4a
XTENDEX
Network Technologies Inc
NTI
R
+
-
3
3
4a
XTENDEX
Network Technologies Inc
NTI
R
+
-
4b
XTENDEX
Network T echnolo gies Inc
NTI
R
+
-
R
XTENDEX
Network Tech nologies Inc
NTI
910
3
(Front View)(Rear View)
ST-C5KM-600 Local Unit
3
Page 7
NTI XTENDEX 600 Foot Extenders
FEATURES AND FUNCTIONS
1. Green LED- traffic indicator- illuminates when there is communication between the local and remote units.
2. Yellow LED- power indicator- illuminates when power has been supplied to the unit
3. Cat 5- RJ45 female- for connecting the CAT 5 cable
4a. Video Connector- 15HD female- for connecting the local user's VGA monitor
4b. S-Video Connector- 4 pin miniDIN female- for connecting the local user's S-video display (S-Video models
5a. RS232 Connector- 9D male- for connecting the local user's touchscreen monitor (models with RS232
support only)
5b. Audio Jack- 3.5mm stereo audio jack- for connecting to local speakers (models with audio support only)
6. Mouse Connector- green female 6 miniDIN- for connecting the local user's mouse
7. Keyboard Connector- purple female 6 miniDIN- for connecting the local user's keyboard
8a. Video Connector- blue 15HD male- for connecting to the video port on the CPU or KVM switch
8b. S-Video Connector- black 4 pin miniDIN male- for connecting to the s-video port on the video source
(S-Video models only)
9. Mouse Connector- green male 6 miniDIN- for connecting to the mouse port on the CPU or KVM switch
10. Keyboard Connector- purple male 6 miniDIN- for connecting to the keyboard port on the CPU or KVM switch
11a. RS232 Connector- light gray 9D female- for connecting to the RS232 port on the CPU or KVM switch
(models with RS232 support only)
11b. Audio Plug- 3.5mm stereo audio plug- for connecting to CPU audio line out (models with audio support
only)
11c. Audio Plug- red RCA plug- for connecting to the right channel audio (model ST-C5SVA-600 only)
11d. Audio Plug- white RCA plug- for connecting to the left channel audio (model ST-C5SVA-600 only)
12. Keyboard Connector- purple female 6 miniDIN- for connecting the remote user's keyboard
13. Mouse Connector- green female 6 miniDIN- for connecting the remote user's mouse
14a. RS232 Connector- 9D male- for connecting the remote user's touchscreen monitor (models with RS232
support only)
14b. Audio Jack- 3.5mm stereo audio jack- for connecting to remote speakers (models with audio support only)
15. 9VDC- 1.0A- connection jack for the AC adapter
16a. Video Connector- 15HD female- for connecting the remote user's monitor
16b. S-Video Connector- 4 pin miniDIN female- for connecting the remote user's S-video display (S-Video
models only)
17. Buttons- for manually adjusting video quality (models ST-C5V-600, ST-C5SV-600, and ST-C5KVMRS-600-SCI only)
14b
only)
1213
+
-
NTI
Network Technologies Inc
XTENDEX
(Front View) (Rear View)
16a
R
ST-C5KVMA-600 Remote Unit
3
15
XTENDEX
Network Tec hnologies Inc
NTI
R
+
-
4
Page 8
NTI XTENDEX 600 Foot Extenders
+
14b
-
R
NTI
Network Technolo gies Inc
XTENDEX
16b
3
Network Technolo gies Inc
NTI
R
(Front View)(Rear View)
12
-
13
+
XTENDEX
NTI
Network Tec hnologies Inc
14a
ST-C5SVA-600 Remote Unit
17
R
16a
3
R
15
Network Tec hnologies Inc
NTI
(Front View) (Rear View)
ST-C5KVMRS-600-SCI Remote Unit
1213
+
-
1
3
R
NTI
Network Tech nologies Inc
XTENDEX
R
(Front View) (Rear View)
ST-C5KM-600 Remote Unit
3
XTENDEX
ST-C5KVM-600M
REMOTE UNIT
NTI
CAT5
R
R
KVM
USER
9V
1.0 A
R
NTI
www.netw orktechin c.com
ST-C5KVM- 600M
R
NTI
LOCAL UNIT
CAT5
R
KVM
XTENDEX
R
E
M
O
T
E
U
N
T
18
I
ST-C5KVM-600M
3
USER
NTI
www.netw orktechin c.com
ST-C5KVM-600M
15
ST-C5KVM-600M
Remote Module
Front and Rear Views
ST-C5KVM-600M
Local Module
Front and Rear Views
(All XTENDEX 600 foot extender modules have the same connections)
18. USER- .05 SCSI II Female- for connecting cable between module and the user devices
19. CPU- .05 SCSI II Female- for connecting cable between the module and the CPU
R
XTENDEX
XTENDEX
1.0 A
CPU
9V
2
15
Network Tech nologies Inc
NTI
+
-
15
+
-
XTENDEX
+
-
L
0
C
A
L
U
19
N
I
T
18
15
5
Page 9
NTI XTENDEX 600 Foot Extenders
LIMITATIONS
• Hot-plugging of devices is supported provided devices were originally connected at power-up.
• In order for two users to share a PS/2 CPU, the user in control must pause for at least 3 seconds before another user can
take control. After the 3 second pause, either user can take control of the CPU.
For models with RS232 support:
• The RS232 ports on the Local and Remote Units will support serial devices other than touchscreen monitors as follows:
• 2 simple devices (i.e. mice) connected to each
• 1 complex device (i.e. serial modem, RS232 command port on an NTI switch) connected to
either
•In order for two users to share a PS/2 CPU, the user in control must pause for at least 3 seconds before another user can
take control. After the 3 second pause, either user can take control of the CPU.
•The RS232 port supports all baud rates up to 56K bits per second and the attached CPU must be configured accordingly.
For models with audio support:
• The audio input of the XTENDEX with audio support is compatible with the following standard CPU audio outputs:
• To connect the ST-C5SVA-600 to a CPU, it may be necessary to use an RCA phono-to-3.5mm stereo jack adapter
• The audio output of the XTENDEX with audio support is compatible with self-powered stereo speakers.
the Remote or Local Unit.
• Line out - typically lime green in color
• Speaker out- typically orange in color
• Headphone out- typically located on the CD-ROM
unit, or
PREPARATION FOR INSTALLATION
•Locations should be chosen for the monitors, mice, and keyboards that also have space to connect the Remote and Local
Units within the distance provided by the cables. If extension cables are needed, contact NTI for the cables required.
•The CAT5 cables must be run to the locations where the Remote and Local Units will be connected. Be careful to route the
cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the video signal
(i.e. AC motors, welding equipment, etc.).
•All cables should be installed in such a way that they do not cause stress on their connections to the equipment. Extended
lengths of cable hanging from a connection may interfere with the quality of that connection. Secure cables as needed to
minimize this.
•Properly shut down and disconnect the power from the CPU and monitors to be separated. If other equipment is involved
whose connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper
disconnection and re-connection procedures before proceeding.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products
should not be run underground, outdoors or between buildings.
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
6
Page 10
NTI XTENDEX 600 Foot Extenders
INSTALLATION
Installing The Local Unit (models with VGA video connectors)
1. Plug the cables of the Local Unit into the back of the CPU. (See Figure 1.)
a) Connect the blue 15HD cable end to the VGA port on the back of the CPU.
b) Connect the purple 6 pin miniDIN cable end with the keyboard symbol
on it to the keyboard port on the back of the CPU. (KVM models only)
c) Connect the green 6 pin miniDIN cable end with the mouse symbol
on it to the mouse port on the back of the CPU. (KVM models only)
DEVICE
CONNECTORS
(LIGHT GRAY- RS232)
6 pin miniDIN
Female
Connector
(PURPLE-KEYBOARD)
6 pin miniDIN
Male Connector
SERIAL
CONNECTOR
(GREEN-MOUSE)
9D Male
RS232 Connector
VIDEO
CONNECTOR
15HD Female
Video Connector
PS/2 CPU
15HD Male
Video Connector
(BLUE- VIDEO)
ST-C5KVMRS-600 Local Unit
(Front View)
(Keyboard)
9D Female Connector
NTI
Network Tech nologies Inc
XTENDEX
(Mouse)
-
R
+
Figure 1- Connect the Local Unit with VGA video and RS232 support to the CPU
d) If the Local Unit has RS232 support, connect the light gray 9D cable end to the RS232 port on
the back of the CPU.
e) If the Local Unit has Audio support, connect the black 3.5mm stereo plug into the "line out",
"spkr", or "headphones" jack on the back of the CPU. (See Figure 2)
Notes:
If all 3 jacks are available, use the jack marked "line out".
The "line out" jack is typically lime green and may be marked with this symbol
The "spkr" jack is typically orange, and may be marked with this symbol
The "headphones" jack may be marked with this symbol
7
Page 11
NTI XTENDEX 600 Foot Extenders
(PURPLE-KEYBOARD)
AUDIO CONNECTOR
ONE WILL BE MARKED "line
out" ,"spkr", "headphones"
OR WITH THIS SYMBOL
line
out
PS/2 CPU
(GREEN-MOUSE)
(BLUE- VIDEO)
(BLACK- AUDIO)
ST-C5KVMA-600 Local Unit
(Front View)
3.5mm Stereo Plug
Figure 2- Connect the Local Unit with Audio support to the CPU
Female Connector
2. Make connections for a local user (see Figure 3)
a) Connect the cable from the local user's VGA monitor to the female 15HD port on the Local Unit.
b) Connect the local user's keyboard to the purple 6 pin miniDIN female port on the Local Unit.
c) Connect the local user's mouse to the green 6 pin miniDIN female port on the Local Unit.
9D Male
RS232 Connector
ST-C5KVMRS-600 Local Unit (Front and Rear View)
Front View of
Local Unit
NTI
Network Technologies Inc
R
XTENDEX
6 pin miniDIN
+
-
Rear View of Local Unit
VGA
Multi-Scan
Touch-screen
Monitor
R
NTI
Network Tech nologies Inc
XTENDEX
15HD Female
Video Connector
+
-
Figure 3- Connect the local user to the XTENDEX Local Unit
PS/2 KEYBOARDPS/2 MOUSE
Local User's Keyboard, Monitor, and Mouse
8
Page 12
NTI XTENDEX 600 Foot Extenders
d) If the Local Unit has RS232 support, connect the local user's RS232 cable from a touch screen
monitor to the 9D male port on the Local Unit.
e) If the Local Unit has audio support, connect the cable from the local speakers to the 3.5mm
stereo audio jack on the Local Unit. (See Figure 4)
ST-C5KVMA-600 Local Unit
Front View
R
NTI
Network Tech nologies Inc
XTENDEX
+
-
3.5mm Stereo
Audio Jack
Stereo
Speakers
Figure 4- Connect stereo speakers to XTENDEX Local Unit with audio support
Installing The Local Unit (models with S-Video connectors)
1. Plug the cables of the Local Unit into the back of the s-video source. (See Figure 5.)
a) Connect the 4 pin miniDIN male cable end to the s-video port on the video source.
b) If the Local Unit has audio support, connect the red RCA plug to the "right" speaker jack on the
audio source and connect the white RCA plug to the "left" speaker jack on the audio source.
Note: Refer to the owner's manual of the s-video/audio source to determine how the left and right audio channels are
labeled.
DVD Player
4 pin miniDIN Male
S-Video Connector
White RCA Plug
Left Channel
Red RCA Plug
Right Channel
R
NTI
Network Tech nologies Inc
XTENDEX
ST-C5SVA-600 Local Unit
(Front View)
+
-
Figure 5- Connect the S-Video Local Unit to the s-video/audio source
9
Page 13
NTI XTENDEX 600 Foot Extenders
2. Make connections for a Local User (see Figure 6)
a) Connect one end of an SVEXT-xx-MM cable to the s-video port on the display.
b) Connect the other end of the same SVEXT-xx-MM cable to the s-video port on the Local Unit.
c) If the Local Unit has audio support, connect the cable from the local speakers into the 3.5mm
jack on the local unit.
Front View
NTI
Network Tec hnologies Inc
XTENDEX
ST-CSVA-600 Local Unit
+
-
R
3.5mm Stereo
Audio Jack
Speakers
Rear View
SVEXT-xx-MM
S-Video
Display
Stereo
Local User's Display
Figure 6- Connect S-Video display and speakers to Local Unit with s-video support
Installing the Local Unit (models with only KM connectors)
1. Plug the cables of the Local Unit into the back of the CPU. (See Figure 7)
a) Connect the green 6 pin miniDIN cable end with the mouse symbol on it to the mouse port on the back of the CPU.
b) Connect the purple 6 pin miniDIN cable end with the keyboard symbol on it to the keyboard port on the back of the
CPU.
DEVICE
CONNECTORS
6 pin miniDIN
Female Connector
(GREEN-MOUSE)
(PURPLE-KEYBOARD)
PS/2 CPU
6 pin miniDIN
Male Connector
NTI
Network Tech nologies Inc
XTENDEX
R
ST-C5KM-600 Local Unit
(Front View)
Figure 7- Connect Local Unit with only keyboard and mouse support
10
Page 14
NTI XTENDEX 600 Foot Extenders
Connect The CAT5 Cable
Connect the CAT5 cable to the “Cat 5” port on the Local Unit.
(See Figure 8.) When properly inserted the cable end should
snap into place.
Note: If an RJ45 wall outlet is being used, connect the other
end of the extension cable to the RJ45 wall outlet.
!
WARNING: Never connect the XTENDEX to an Ethernet
card, Ethernet router, hub or switch or other Ethernet RJ45 connector
of an Ethernet device. Damage to devices connected to the
Ethernet may result.
Yellow Power LED
Rear View of Local Unit
Green Traffic LED
XTENDEX
Network Tech nologies Inc
NTI
R
+
-
CAT5 Cable to
Remote Unit
Figure 8- Connect CAT5 cable to Local Unit
Installing The Remote Unit (models with VGA video connectors)
1. Position the Remote Unit such that the CAT5 cable, the monitor cable, device cables, and the AC
adapter power connector can each reach the Remote Unit without putting strain on the cables.
2. Connect the monitor cable to the female 15HD video connector on the Remote Unit.
3. Connect the device(s) to the Remote Unit (see Figure 9)(KVM models only).
a) Connect the keyboard to the purple female 6 pin miniDIN connector on the Remote Unit.
b) Connect the mouse to the green female 6 pin miniDIN connector on the Remote Unit.
4. If the Remote Unit has RS232 support, connect the remote user's RS232 cable from a touch
screen monitor to the 9D male port on the Remote Unit.
5. If the Remote Unit has audio support, connect the cable from the remote speakers to the 3.5mm
stereo audio jack on the Remote Unit. (See Figure 9)
11
Page 15
NTI XTENDEX 600 Foot Extenders
9D Male
RS232 Connector
ST-C5KVMRS-600 Remote Unit (Front and Rear View)
Front View of
Remote Unit
+
-
NTI
Network Technol ogies Inc
XTENDEX
R
6 pin miniDIN
Female Connector
Rear View of Remote Unit
15HD Female
Video Connector
VGA
Multi-Scan
Monitor
PS/2 KEYBOARDPS/2 MOUSE
Remote User's Keyboard, Monitor, and Mouse
Figure 9- Connect the Extended Components to the Remote Unit
ST-C5KVMA-600 Remote Unit
Front View
+
-
R
NTI
Network Tech nologies Inc
XTENDEX
3.5mm Stereo
Audio Jack
Stereo
Speakers
Figure 10- Connect speakers to the Remote Unit
12
Page 16
NTI XTENDEX 600 Foot Extenders
Installing The Remote Unit (models with S-Video connectors)
1. Position the Remote Unit such that the CAT5 cable, the s-video cable, speaker cable, and the AC
adapter power connector can each reach the Remote Unit without putting strain on the cables.
2. Connect one 4 pin miniDIN end of another SVEXT-xx-MM cable to the Remote Unit.
3. Connect the other 4 pin miniDIN end of the SVEXT-xx-MM cable to the s-video port on the display.
4. If the Remote Unit has audio support, connect the speakers to the 3.5mm jack on the Remote Unit
(see Figure 11).
3.5mm Stereo
Audio Jack
-
+
XTENDEX
Front View
R
NTI
Network Technologies Inc
ST-C5SVA-600 Remote Unit
Rear View
SVEXT-xx-MM
Stereo
Speakers
Remote User's Display
S-Video
Display
Figure 11- Connect components to an S-Video Remote Unit
13
Page 17
NTI XTENDEX 600 Foot Extenders
Installing The Remote Unit (models with only KM connectors)
1. Position the Remote Unit such that the CAT5 cable, the keyboard cable, mouse cable and power supply cable can each
reach the Remote Unit without putting strain on the cables.
2. Connect the keyboard to the purple female 6 pin miniDIN connector on the Remote Unit.
3. Connect the mouse to the green female 6 pin miniDIN connector on the Remote Unit.
ST-C5KM-600 Remote Unit
Front View
+
-
R
NTI
Network Tech nologies Inc
XTENDEX
6 pin miniDIN
Female Connector
Remote User's Keyboard and Mouse
PS/2 KEYBOARDPS/2 MOUSE
Figure 12- Connect keyboard and mouse to Remote Unit
Connect the CAT5 cable
Make sure the CAT5 cable has been installed in accordance with the “Preparation for Installation”
instructions on page 3. Connect the CAT5 cable to the “Cat 5” port on the Remote Unit. (See Figure 13.)
When properly inserted the CAT5 cable end should snap into place.
Note: If an RJ45 wall outlet is being used, connect
the other end of the extension cable to the RJ45 wall
outlet.
!
WARNING: Never connect the XTENDEX to
an Ethernet card, Ethernet router, hub or switch or other
Ethernet RJ45 connector of an Ethernet device. Damage
to devices connected to the Ethernet may result.
Figure 13- Connect the CAT5 cable to the Remote Unit
Rear View of Remote Unit
XTENDEX
Network Technologies Inc
NTI
R
+
-
CAT5 Cable to
Local Unit
14
Page 18
NTI XTENDEX 600 Foot Extenders
Plug-in and Boot Up
1. Plug the power cord from the monitor into the power outlet.
Connect each AC adapter power connector to the 9VDC ports on the Remote and Local Units Plug each AC adapter into a
2.
power outlet. The yellow LED on the RJ45 connector of both the Remote and Local Units should illuminate, indicating that a
proper power connection has been made to them. (See Figure 14.)
Green Traffic LED
3. Turn ON the CPU and Monitor. They should each react as if they were directly connected to each other.
Note: The green LED on each RJ45 connector will illuminate anytime data traffic is passing between the Local and
Remote Units, indicating proper CAT5 cable connection and communication. (See Figure 14)
Rear View of Remote Unit
Yellow Power LED
Barrel
9 VDC
Adapter
ADAPTER
Power Connector
9VDC @ 1.0A OUTPUT
(Outside
barrel)
2.1 mm x 5.5 mm Female
Figure 14- Connect the AC adapter to the Remote Unit
(Inside
barrel)
15
Page 19
NTI XTENDEX 600 Foot Extenders
Rackmount Modules (optional)
If ST-C5-600M Series XTENDEX rackmount modules (Local and/or Remote modules) are being installed, then an ST-C5RCK-12
Rackmount Extender Module Tray must be used (sold separately) to mount the modules to a RACK. The ST-C5RCK-12
provides a convenient mounting method for up to 12 Local and /or Remote XTENDEX modules.
Note: Rackmount Local modules are compatible with rackmount Remote modules or desktop Remote units.
Mount the ST-C5RCK-12 Rackmount Extender Module Tray
1. The ST-C5RCK-12 Rackmount Extender Module Tray was designed to be directly mounted in a rack. It includes a mounting
flange to make attachment easy.
2. Install 4 cage nuts (supplied) to the rack in locations that line up with the holes in the mounting flange on the tray.
Then secure the tray to the rack using four #10-32 x 3/4” screws (supplied). Be sure to tighten all mounting screws securely.
#10-32 x 3/4"
Rack Screws
(supplied)
Rack
Cage Nuts
(supplied)
Figure 15- Mount ST-C5RCK-12 Extender Module Tray in a rack
3. Slide each module into the tray and line up the holes in the mounting plate on the module with corresponding holes in the tray.
Secure the module(s) using the two screws provided. Blank plates and screws are provided to cover empty module spaces.
Frontview of ST-C5RCK-12 with XTENDEX Extender Modules
NTI
XTENDEX
ST-C5KVM-6 00M
LOCAL UNIT
CAT5
R
R
KVM
4. Secure the power supply for each module to the power supply/cable management shelf at the rear of the tray using the bracket
and screw supplied.
NTI
XTENDEX
ST-C5KVM-6 00M
LOCAL UNIT
CAT5
R
R
KVM
NTI
XTENDEX
ST-C5KVM-600M
LOCAL UNIT
CAT5
R
R
KVM
Secure XTENDEX module(s) to the ST-C5RCK-12
using the screws provided.
Figure 16- Secure each module to the tray
16
Page 20
NTI XTENDEX 600 Foot Extenders
Rearview of ST-C5RCK-12 with XTENDEX Extender Modules
Power supply/cable managment shelf
Power supply mounting bracket
(supplied with each module)
Figure 17- Secure each power supply to the tray
USER
R
NTI
1275 Danner Dr
Aurora, OH 44202
Tel:330-562-7070
Fax:330-562-1999
www.networktechinc.com
ST-C5USB VA-30 0M
CPU
L
0
C
A
L
U
N
I
9V
1.5 A
T
Plug power connector
into Extender module
Connect power cord to
power supply here
Secure each power supply to the tray
using the bracket and screw provided.
17
Page 21
NTI XTENDEX 600 Foot Extenders
Connect the CPU
Connect a cable between the Local Unit and the CPU. Use the appropriate cable for the application (see chart below).
Figure 18 shows the proper connections for the ST-C5KVMA-L-600M using a VMATINT-xx-MM cable (xx= 3, 6, 10, 15 or 25 foot
length). Make sure all connections are firmly seated.
AUDIO CONNECTOR
ONE WILL BE MARKED "line
out" ,"speaker", "headphones"
OR WITH THIS SYMBOL
line
out
PS/2 CPU
6mD-Male
Mouse Connector
(Green)
6mD-Male
Keyboard Connector
(Purple)
3.5mm Stereo Plug
VMATINT-3/6/10/15/25-MM
0.05 SCSI II series
15HD male
Video Connector
REAR VIEW
ST-C5KVMA-L-600M
(Local Unit)
Connect to
ST-C5KVMA-L-600M
Local Unit at "CPU"
USER
CPU
9V
1.0 A
R
NTI
www.networktechinc.com
ST-C 5KVMA-60 0M
L
0
C
A
L
U
N
I
T
Figure 18- Connect cable between CPU and module
Cables for connecting 600M modules to a CPU
Features Supported:
Cable To Use Video Keyboard/Mouse Audio RS232
VMCTINT-xx-MM Y Y N N
VMATINT-xx-MM Y Y Y N
VMRSTINT-xx-MM Y Y N Y
VTINT-xx-MM Y N N N
VATINT-xx-MM Y N Y N
VRSTINT-xx-MM Y N N Y
xx= 3, 6, 10, 15 or 25 foot length
18
Page 22
NTI XTENDEX 600 Foot Extenders
Connect the Devices
Connect a cable to the monitor, keyboard, mouse, speakers (if supported), and touch screen RS232 cable (if supported) and then
to the Local or Remote Unit at the connector marked “USER”. Figure 19 shows the proper connections for the ST-C5KVMA-R600M (remote unit) using a VMATINT-xx cable (xx=3,6,10,15 or 25 foot length). Use the appropriate cable for the application (see
chart below). Make sure all connections are firmly seated.
Connect to
ST-C5KVMA-R-600M
Local Unit or
Remote Unit
at "USER"
0.05 SCSI II series
USER
VMATINT-3/6/10/15/25
15HD-Female
Video Connector
6mD-Female
Keyboard Connector (Purple)
VGA
Multi-Scan
Monitor
R
NTI
www.ne tworktechi nc.com
ST-C5KVMA-600M
9V
1.0 A
R
E
M
O
T
E
U
N
I
T
REAR VIEW
ST-C5KVMA-R-600M
(Remote Unit)
6mD-Female
Mouse Connector (Green)
3.5MM-Stereo Jack
PS/2
Mouse
Figure 19- Connect cable between user and module
Cables for connecting 600M modules to user devices
Features Supported:
Cable To Use Video Keyboard/Mouse Audio RS232
VMCTINT-xx Y Y N N
VMATINT-xx Y Y Y N
VMRSTINT-xx Y Y N Y
VTINT-xx Y N N N
VATINT-xx Y N Y N
VRSTINT-xx Y N N Y
xx= 3, 6, 10, 15 or 25 foot length
PS/2 Keyboard
Stereo
Speakers
19
Page 23
NTI XTENDEX 600 Foot Extenders
Connect the CAT5 cable
Connect the CAT5 cable to the “CAT5” port on the front of the Local Unit (see Figure 20). When properly inserted the
cable end should snap into place. Connect the other end of the cable to the “CAT5” port on the Remote Unit.
WARNING: Never connect the XTENDEX to an Ethernet card, Ethernet router hub or switch
or other Ethernet RJ45 connector of an Ethernet device. Damage to devices connected to the Ethernet may
!
result.
NTI
XTENDEX
ST-C5KVM-600M
LOCAL UNIT
CAT5
R
R
KVM
XTENDEX
Network Tech nologies Inc
NTI
R
(Front View)
CAT5 Cable- up to 300 feet
Connect Local unit to either
rackmount Remote Unit module
(ST-C5KVMA-R-600M) or
desktop Remote Unit
(ST-C5KVMA-R-600)
-OR-
ST-C5KVMA-R-600 Remote Unit
Yellow Power LED
Green Traffic LED
ST-C5KVMA-R-600M
Remote Unit
(Front View)
NTI
XTENDEX
ST-C5KVM-600M
REMOTE UNIT
CAT5
R
R
KVM
Figure 20- Connect the CAT5 cable between the Local and Remote Units
20
Page 24
NTI XTENDEX 600 Foot Extenders
Plug-in and Boot Up
1. Plug the power cord(s) from the monitor(s) into power outlet(s).
2. Connect the AC adapter power connectors to the 9VDC ports on the Remote and Local Units. (AC adapter shown in
Figure 21)
3. Plug the AC adapters into power outlets. The “Power” LED (yellow) on the CAT5 connector of each unit should illuminate,
indicating that a proper power connection has been made.
4. Turn ON the CPU and monitor(s). The CPU and monitor(s) should each react as if they were directly connected to each
other. The green “Traffic” LEDs on the Remote and Local Units (see Figure 20) should blink indicating there is proper
communication between them.
Note: A loss of signal (blank screen) may be experienced for an instant during the automatic video quality adjustment
process after powering-up. This may also occur if the XTENDEX senses a loss of or weak signal connection in the
CAT5 cable.
USER
R
NTI
1275 Danner Dr
Aurora, OH 44202
Tel:330-562-7070
Fax:330-562-1999
www.networktechinc.com
ST-C5USBVA-30 0M
CPU
L
0
C
A
L
U
N
ST-C5KVMA-600M
I
9V
1.5 A
T
(Local Unit-Rearview)
USER
CPU
L
0
C
A
L
U
N
I
9V
1.0 A
R
T
NTI
www.networktechinc.com
ST-C5KVMA-600M
REAR VIEW
ST-C5KVMA-L-600M
(Local Unit)
Figure 21- Connect AC adapters
21
Page 25
NTI XTENDEX 600 Foot Extenders
VIDEO QUALITY
Automatic Video Quality Adjustment(see chart on page 1)
Video quality adjustment is done automatically to assure the image is as clear as possible.
Note: When the cable is longer than 300 feet some colored lines can be seen at the black-to-white transitions. This is a
normal behavior and is caused by the different twisting rates of each pair of wires in the CAT5 cable.
Manual Video Quality Adjustment (see chart on page 1)
It is possible that on initial startup the image on the monitor will not be as crisp as the image normally is. This is due to the
frequency characteristics of the CAT5 cable. It may be necessary to press the "+" or "-" buttons (see Figure 22) until the image
is crisp and clear. Press the "+" button if the image is not crisp and clear enough. Press the "-" button if the image has been
over-corrected (such that horizontal lines appear to trail or shadow at the edge of an open window). A momentary press of either
button will make a minor change in the image. If either button is pressed and held, the changes made will be gradual and
continuous. Ultimately, the image quality should improve to a satisfactory level. Once the adjustment is made, it should not be
necessary to change it again, as the new settings are stored in memory and become the default settings with each startup.
Note: When the cable is longer than 300 feet some colored lines can be seen at the black-to-white transitions. This is a
normal behavior and is caused by the different twisting rates of each pair of wires in the CAT5 cable.
Side view of ST-C5V-600 Remote Unit
Press using pen or other
pointed object to improve
screen image
NTI
XTENDEX
+
_
_
CAT5
ST-C5V-600M
REMOTE UNIT
R
R
V
Front View
ST-C5V-600M
Remote Unit
Figure 22- Buttons for video quality adjustment
If the image still lacks definition, configuration adjustments may need to be made to the attached video display equipment. This is
a problem most often seen in LCD displays. Check the manual for the equipment having the poor display and look for an "autoadjust" or "auto-configure" feature. Once this is done, you may need to repeat the Video Quality Adjustment procedure
described above to achieve the best image.
22
Page 26
NTI XTENDEX 600 Foot Extenders
TECHNICAL SPECIFICATIONS
Models with VGA Video
Video Compatibility SVGA, XGA, VGA
Video Coupling DC
Video Connectors HD15 male to CPU
Input / Output Impedance 75 Ohms
Input Horizontal Frequency Range 15kHz to 130 Hz
Input Vertical Frequency Range 30 Hz to 150 Hz
Sync Types Supported Separate and composite TTL Level and sync on green
Video Maximum I/O Levels 1.45Vp-p
Models with S-Video
Video Compatibility All s-video displays and sources
Video Coupling DC
Video Connectors 4 pin miniDIN male to video source
Video Maximum I/O Levels 1.45Vp-p
Input / Output Impedance 75 Ohms
Models with Keyboard/Mouse support
Keyboard/Mouse Connectors Female 6 pin miniDIN to Keyboard and Mouse
Mouse and Keyboard Compatibility All PS/2 mice and keyboards
Keyboard and Mouse Current Rating 500mA maximum
Models with Audio Support
Audio Connectors 3.5mm stereo jack to speakers
Signal Type Line Level, stereo, unbalanced
Audio Frequency Response 20Hz to 20Khz, + 1dB
Signal-to-noise ratio 76 dBA
Total Harmonic Distortion and Noise 0.017%
Stereo Crosstalk -70 dB
Audio Maximum I/O Levels 3.1Vp-p
Output Impedance Max 2K Ohms, unbalanced
THD+N 0.017%,F=20-20KHz, RL=2K Ohm, Vout=1 Vrms
Models with RS232 Support
RS232 Connectors 9D male to device
RS232 Baud Rate 56K bps maximum (no adjustment for baud rate is needed)
RS232 Compatibility RXD, TXD, RTS, DTR, CTS, DSR
General
Interconnect Cable CAT5/5e/6 Solid UTP EIA/TIA 568 B wiring w/ male RJ45 connectors
Remote and Local Unit Power 120V or 240V at 50 or 60Hz-9VDC/1.0A via AC Adapters (2)
Dimensions WxDxH (In.) (Local or Remote) 3.1x3.4x1 (Desktop models)
Dimensions WxDxH (In.) (Local or Remote) 1.4x6.8x3.5 (Rackmount modules)
HD15 female to monitor
4 pin miniDIN female to display
Male 6 pin miniDIN to CPU device ports
3.5mm stereo plug to CPU (VGA Video Models)
RCA phono plug to audio source (S-Video Models)
9D female to CPU
Distances and Resolutions for CAT5/CAT5e and CAT6 Cables
Unshielded Twisted Pair (UTP) Resolutions
UTP CABLE DISTANCE (feet) RESOLUTION
CAT5/CAT5e 600 1024x768 at 60Hz
CAT5/CAT5e 400 1280x1024 at 60Hz
CAT5/CAT5e 300 1600x1200 at 60Hz
CAT5/CAT5e 100 1920x1440 at 60Hz
CAT6 300 1024x768 at 60Hz
CAT6 200 1280x1024 at 60Hz
CAT6 100 1920x1440 at 60Hz
23
Page 27
NTI XTENDEX 600 Foot Extenders
INTERCONNECTION CABLE WIRING METHOD
The connection cable between the remote and local is terminated with RJ45 connectors and must be wired according to the
EIA/TIA 568 B industry standard. Wiring is as per the table and drawing below.
1 White/Orange 2 T
2 Orange 2 R
3 White/Green 3 T
4 Blue 1 R
5 White/Blue 1 T
6 Green 3 R
7 White/Brown 4 T
8 Brown 4 R
Pin Wire Color Pair Function
Pair 2Pair 1
T
1
+
Figure 23- View looking into RJ45 female
Pair 3
Pair 4
T
R
R
T
3
2
4
-
5
+
-
+
R
R
T
8
6
7
+
-
-
TROUBLESHOOTING
Each and every piece of every product produced by Network Technologies Inc is 100% tested to exacting specifications. We
make every effort to insure trouble-free installation and operation of our products. If problems are experienced while installing this
product, please look over the troubleshooting chart below to see if perhaps we can answer any questions that arise. If the
answer is not found in the chart, please check the FAQs (Frequently Asked Questions) at our website at
http://www.networktechinc.com or contact us directly for help at 1-800-742-8324 (800-RGB-TECH) in US & Canada or 1-330-5627070 worldwide. We will be happy to assist in any way we can.
Problem Cause Solution
Remote or Local Unit
yellow power LED does
not illuminate
Local power LED does
not illuminate when the
CPU is powered
No Video on monitor
Video Picture is not sharp
or is smeared
•Power supply is not connected or
plugged-in.
•The keyboard connector is not
properly plugged in
•One or more video cables is loose
or disconnected.
•No power to Remote or Local
Units.
•Video Cable was not attached
when CPU was booted.
• CAT5 cable is not connected.
• All Video Cables are not firmly
seated.
• CAT5 cable is too long.
• The CAT5 cable is not properly
connected.
• Video not adjusted
• Make sure outlet is live and AC adapter is plugged-in.
(one for the Remote and one for the Local)
• Make sure 9VDC jack is fully connected
• Check keyboard connection
• Check all video cable connections
• Make sure yellow LEDs are illuminated for local and
remote. If not, see solutions for first two problems above.
• With all the cables properly connected, reboot the CPU.
• Check cable connections. Make sure they are snapped-
in properly and completely and reboot.
•Check all connections. Make sure all cables are fully
seated.
• Verify length is within specified limits-600'.
• Check cable connections. Make sure they are snapped-
in properly and completely.
•Check cable connections and power cycle. If model has
manual quality adjustment buttons see page 22 for
adjustment instruction.
24
Page 28
NTI XTENDEX 600 Foot Extenders
Problem Cause Solution
The picture on the monitor
is black and white, rather
than color
A constant vertical wobble
appears down the screen
Monitor sometimes loses
sync, causing it to go
blank for a second or two
Wrong or missing
characters from those
typed
CPU doesn't detect the
keyboard and the mouse
IBM Scroll Point mouse is
not recognized by CPU
Image is not displayed
properly, lacks definition
Models with RS232 Support
No RS232 communication
Models with Audio Support
No audio
The video cable was not attached to
the CPU when it was booted.
CAT5 cable is too close to a strong
power source.
•Electrical power system is very
noisy, particularly the ground.
•The CAT5 cable is not properly
connected.
The keyboard may be in the wrong
mode.
•Keyboard cable or mouse cable
are loose or reversed
•Cat 5 cable is too long
Only one IBM Scroll Point mouse is
connected at either the Local or
Remote unit
Signal is being skewed by the CAT5
cable and not being received correctly
by the monitor .
•One or more RS232 cables is
loose or disconnected
•Audio cable is not properly
plugged in
• Speakers are not plugged in
• CAT5 cable is not properly
connected
With the cables all properly connected, reboot the CPU.
Reroute CAT5 cable if possible.
•Make sure the interconnection cable is not near any
power lines.
•Check cable connections. Make sure they are snapped-
in properly and completely.
• Disconnect keyboard at Remote Unit end and reconnect.
• Reboot the system.
• Check cable connections
• Cat 5 cable can be no more than 600 feet in length
• In order for an IBM Scroll Point mouse to be recognized,
an IBM Scroll Point mouse must be connected at both
the Local and Remote extender units. Otherwise it will
be recognized and work only as a Microsoft Intellimouse.
•Check the user's manual for the monitor, projector, or
display equipment for an "automatic adjustment" or
"auto-configure". This is most common to LCD type
monitors.
mount to a rack, 16
preparation to install, 6
Rackmount modules, 16
resolution chart, 23
ST-C5RCK-12, 16
technical specification, 23
video quality adjustment, 22
WARRANTY INFORMATION
The warranty period on this product (parts and labor) is two (2) years from the date of purchase. Please contact Network
Technologies Inc at
for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products
should not be run underground, outdoors or between buildings.
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
(800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at http://www.networktechinc.com
Manual 014 Rev. 6/26/09
25