The material in this guide is for information only and is subject to change without notice. Network Technologies Inc reserves the
right to make changes in the product design without reservation and without notification to its users.
SOFTWARE VERSIONS
Front Panel LCD Software Version 1.2
Ethernet Control Software Version 1.20
Supported Web Browsers............................................................................................................................................1
Optional Features .....................................................................................................................................................1
Default User Name and Passwords ............................................................................................................................2
Features and Functions................................................................................................................................................3
Connect the Sources...................................................................................................................................................4
Connect the Monitors and Speakers...........................................................................................................................5
Connect to the Ethernet...............................................................................................................................................6
Power Up.....................................................................................................................................................................6
LED Matrix......................................................................................................................................................................6
Control Options.............................................................................................................................................................7
Front Panel LCD with Keypad Control.........................................................................................................................7
Making Connections .................................................................................................................................................7
Menu Button..............................................................................................................................................................9
Unit Address ...........................................................................................................................................................10
Matrix Switcher’s Control Program For Windows 9X, NT, 2000, XP, Vista and 7....................................................13
SerTest- RS232 Interface Test Program...................................................................................................................13
Main Options...........................................................................................................................................................13
RU-Read Unit Size..............................................................................................................................................17
RO-Read Connection for Output Port .................................................................................................................17
CS- Connect Output Port to Input Port................................................................................................................17
CA- Connect All Output Ports to Input Port.........................................................................................................17
SS_01- Enable Auto Status Mode.......................................................................................................................18
SS_00- Disable Auto Status Mode......................................................................................................................18
AR- Read Mute and Volume for Audio Output Port ............................................................................................21
Web Interface ............................................................................................................................................................22
Enter the Password ................................................................................................................................................22
Main Menu.................................................................................................................................................................23
ii
Page 4
Video Switch Page ..............................................................................................................................................23
User Management ..................................................................................................................................................27
Help Page............................................................................................................................................................33
Update Web Server.............................................................................................................................................33
How to Use the Device Discovery Tool.....................................................................................................................35
Infrared Control ...........................................................................................................................................................36
Features And Functions.............................................................................................................................................36
How To Use The IRT.................................................................................................................................................37
Change the Switch..................................................................................................................................................37
Set Configuration....................................................................................................................................................39
Pinout of RS232 port on VEEMUX-A ........................................................................................................................44
Specifications for Straight-Through Serial Cable for CPU Connection.....................................................................44
Pinout for Matrix-Y-1 Cable .......................................................................................................................................45
Figure 1- Install Audio and Video Source Cables ..............................................................................................................................4
Figure 2- Install Monitors and Speakers ............................................................................................................................................5
Figure 3- Connect user terminal for RS232 control............................................................................................................................5
Figure 4- Connect the LAN to the VEEMUX-A...................................................................................................................................6
Figure 5- LED Matrix showing input 5 connected to output 5.............................................................................................................6
Figure 6- RS232 Connections for Daisy-chain.................................................................................................................................10
Figure 7- Web interface Welcome page.........................................................................................................................................22
Figure 8- Web interface Login Prompt.............................................................................................................................................22
Figure 9- Administrator Menu ..........................................................................................................................................................23
Figure 10- Web interface Video Switch page...................................................................................................................................23
Figure 11- Web interface Audio Switch page...................................................................................................................................25
Figure 12- Web interface Setup page..............................................................................................................................................26
Figure 13- Web interface Serial Setup page....................................................................................................................................26
Figure 15- Add User page................................................................................................................................................................27
Figure 16- Edit User settings ...........................................................................................................................................................28
Figure 17- Web interface Video Input Names page.........................................................................................................................29
Figure 18- Output Port Names.........................................................................................................................................................29
Figure 20- Web interface Update Firmware page............................................................................................................................32
iii
Page 5
Figure 21- Web interface Password page ........................................................................................................................................33
Figure 22- Updating the Web Server ...............................................................................................................................................33
Figure 23- Web interface Logout page.............................................................................................................................................34
The SM-nXm-AV-LCD Audio/Video Matrix switch (VEEMUX-A) allows up to 32 audio/video sources (n) to be connected to up to
16 destinations (m). Different destinations can even be connected to the same source. Video resolution up to 1920x12 00@85Hz
is supported with no degradation – guaranteed. Stereo audio is supported, as well as volume control and separate audio/video
switching. An LCD on the front panel indicates the current connections. The VEEMUX-A can be controlled by four methods: Front
Panel LCD with Keypad, RS232 interface, Ethernet, or optional Infrared Remote.
Basic Operation
The VEEMUX-A allows any source to be connected to any destination at any time with no restrictions or limitations.
•Audio and Video connections can be made concurrently or separately (i.e. user 1 can view video from port 3
and hear audio from port 11).
• Video inputs accept any RGBHV, RGBS, or RGsB signal.
• Video outputs are compatible with any RGBHV or RGBS monitor, regardless of input. (RGsB monitor requires
RGsB input)
• Audio inputs accept any standard line level audio (1Vrms or 2.5Vp-p).
• Audio outputs are capable of driving an 8 Ohm speaker load with 200mW of continuous RMS power.
• The Audio output volume of the AV matrix is adjustable for each output port.
• Up to 15 users (including the administrator) can have controlled WEB interface access to the VEEMUX
Supported Web Browsers
Most modern web browsers should be supported. The following browsers have been tested:
• Microsoft Internet Explorer 6.0 or higher
• Netscape 7.0 or higher
• Mozilla FireFox 0.9.2 or higher
Set your browser to always check if there is a newer version of the page than the version stored in cache. This action will ensure
that it will display the most up-to-date information.
Ordering Information
The SM-nXm-AV-LCD Audio/Video Matrix switch (VEEMUX-A) can be ordered in many sizes and with several control options.
The base unit includes a user keypad and an RS232 port to make up a complete system, with an option for an infrared control.
The infrared option is purchased separately, allowing for maximum user satisfaction in each unique configuration.
The VEEMUX-A Audio/Video Matrix switch is built to a specific size ranging from 8 to 32 inputs and 2, 4, 8, 12, or 16 outputs.
Simply order an SM-nXm-AV-LCD where the “n” in the part number represents the number of inputs and the “m” in the part
number represents the number of outputs.
SM-nXm-AV-LCD
Replace the “n” with 8,16, or 32
Replace the “m” with 2,4,8,12, or 16
The following list represents the available sizes that can be ordered:
• DDC Support (see page 41)- to order, add "D" to the part number (i.e. SM-nXm-AVD-LCD)
• Infrared Control (see page 36)- to order, add "IR" to the part number (i.e. SM-nXm-AV-LCD-IR)
1
Page 7
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Materials
Materials Supplied with this kit:
• NTI SM-nXm-AV-LCD Audio/Video Matrix switch
• IEC Line cord, country specific
• 4- #10-32 x 3/4" pan head screws and 10-32 cagenuts (server cabinet mounting hardware)
• CD with: a pdf file of this owner's manual
the NTI Discovery Tool
the Matrix Switcher’s Control Program
Cables
All cables are sold separately. The following table lists the available stocked cabl es with their length in feet. All of the 15HD and
BNC input and output connectors on VEEMUX-A are female. Custom cables are available – contact NTI for pricing and distance /
resolution limitations.
NTI NAME DESCRIPTION
VGA
VEXT-3/6/10/15/25/35/50/75/100-MM
VEXT-3/6/10/15/25/35/50/75/100
VINT-5B-6
SA-6/10/15/25/35/50-MM
Matrix-Y-1 or see page 44 for alternative
cables
Contact NTI for various lengths and colors Cat5 UTP Cable- Connectors are RJ45 male-Stocked cables are 2 thru 100 feet
Multi-coax high resolution VGA or SVGA video cable. Connectors are 15HD
male-male (used for INPUTS)- 3 thru 100 feet
Multi-coax high resolution VGA or SVGA video cable. Connectors are 15HD
male-female (used for OUTPUTS)- 3 thru 100 feet
Multi-coax high resolution VGA to BNC cable. Connectors are 15HD male to 5
BNC’s- 6 feet long
AUDIO
Audio Interface Cable- Connectors are 3.5mm male-male - 6/10/15/25/35/50
feet long
RS232
RS232 Interface Cable- Connectors are 9D male- female-female 12" long
(also see alternative cable specifications on page 44)
ETHERNET
Custom cables must have RJ45 connectors wired straight thru- pin 1 to pin 1,
etc.
Default User Name and Passwords
The default Telnet password is admin (lower case letters only) . For instruction on using Telnet, see page
14.
(No username is required in order to use Telnet. You will only be prompted for a password.)
The default Web Interface user name
The default Web Interface password
Interface, see page 22.
is Administrator (upper case letter for "A" only).
is admin (lower case letters only). For instruction on using the Web
2
Page 8
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Front View of VEEMUX-A
ESC
OUT
67
MENU
1
123IN45
21112
13
5
ETHERNET
NTI
1275 Danner Dr
Aurora, O H 44202
R
S
2
3
2
6
78
NETWORK
TECHNOLOGIES
INCORPORATED
Tel:330-562-7070
Fax:330-562-1999
www.nti1.com
VIDEO 7
VIDEO 8
9
8
VIDEO 5
VIDEO 6
9
0
7
8
*
ENTER
AUDIO OUT (USER)
3
5
4
6
VIDEO 3
VIDEO 4
IN
581234 678
OUT
1
DDC
2
3
4
5
6
7
NTI
Network Technologies Inc
Rear View of VEEMUX-A
1
2
VIDEO 1
VIDEO 2
MONITOR 7
MONITOR 8
MONITOR 5
MONITOR 6
10
R
VEEMUX A
AUDIO IN (CPU)
7
8
MONITOR 3
MONITOR 4
R
34
1
3
5
2
4
6
MONITOR 1
MONITOR 2
FEATURES AND FUNCTIONS
1. LCD Display- for visual indication of input-to-output connections and for configuration of the VEEMUX.
2. Keypad- buttons for user control over switch functions
3. AUDIO IN- for connection of audio cables from audio sources
4. AUDIO OUT- for connection of audio cables to audio output devices (speakers)
5. Power ON/OFF switch
6. IEC Power Connector- for attachment of power cord (not available on all units)
8. RS232 In/Out - 9D female connector- for attaching RS232 interface cable from a user terminal
9. VIDEO x- 15HD female connectors- for attachment of video cables from video sources
10. MONITOR x- 15HD female connectors- for connection of video output devices
11. DDC button- for manual update of DDC information between the monitor and the source(s) attached (optional)
12. LED Matrix- for visual indication of all input-to-output connections (page 6) (not available on all models)
13. ETHERNET- RJ45 female connector- for connection of CAT5 cable to Local Area Network (LAN) for WEB interface
3
Page 9
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
INSTALLATION
Connect the Sources
1. Turn OFF power to all video sources (inputs) that will be connected to the VEEMUX-A before connecting or
disconnecting any cables.
2. For each video source, connect a VEXT-xx-MM cable from the video port of the source to a video input
("VIDEO 1") of the VEEMUX-A (see Fig. 1).
3. For each audio source, connect a SA-xx-MM cable from the audio source to an audio input ( "AUDIO IN ") port.
Notes:
The audio port on a CPU may be marked "line out", "spkr", or "headphones". If all 3 jacks are available, use
the jack marked "line out".
The "line out" jack is typically lime green and may be marked with this symbol
The "spkr" jack is typically orange, and may be marked with this symbol
The "headphones" jack may be marked with this symbol
ETHERNET
Video Port
15HD Female
Video Connector
Audio Port
ONE WILL BE MARKED "li ne
out" ,"spkr", "headphones"
OR WITH THIS SYMBOL
line
out
Figure 1- Install Audio and Video Source Cables
NETWORK
NTI
1275 Danner Dr
Aurora, OH 44202
R
S
2
3
2
TECHNOLOGIES
INCORPORATED
Tel:330-562-7070
Fax:330-562-1999
www.nti1.com
Rear View of a CPU
VIDEO 7
VIDEO 8
VIDEO 5
VIDEO 6
AUDIO OUT (USER)
5
7
6
8
VIDEO 3
VIDEO 4
1
3
2
4
VIDEO 1
VIDEO 2
Rear View of VEEMUX-A
15HD Male
Video Connector
HD15-Male
3.5mm Stere o
Plug
SA-xx-MM
4
VEXT-xx-MM
MONITO R 7
MONITO R 8
15HD Female
Video Connector
HD15-Male
3.5mm Stereo
Plug
MONITO R 5
MONITO R 6
AUDIO IN (CPU)
7
8
MONITO R 3
MONITO R 4
1
3
5
2
4
6
MONITOR 1
MONITOR 2
Page 10
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Connect the Monitors and Speakers
1. Connect a video output device to the port labeled MONITOR 1 on the rear of the VEEMUX-A (see Fig. 2).
2. Repeat step 6 for remaining output devices (monitors).
3. Connect audio output device (speakers) to port labeled AUDIO OUT 1.
4. Repeat step 8 for remaining audio output devices, connecting them to any remaining AUDIO OUT ports.
ETHERNET
Figure 2- Install Monitors and Speakers
3.5mm Ste reo
Jack
NTI
1275 Danner Dr
Aurora, OH 44202
www.nti1.com
R
S
2
3
2
NETWORK
TECHNOLOGIES
INCORPORATED
Tel:330-562-7070
Fax:330-562-1999
VIDEO 7
VIDEO 8
Speakers
Rear View of VEEMUX-A
VIDEO 5
VIDEO 6
3.5mm Ste reo
Plug
AUDIO OUT (USER)
7
8
5
6
VIDEO 3
VIDEO 4
3
4
1
2
VIDEO 1
VIDEO 2
MONITOR 7
MONITOR 8
15HD Female
Video Connector
15HD Male
Video Connector
MONITOR 5
MONITOR 6
AUDIO IN (CPU)
7
8
MONITOR 3
MONITOR 4
5
6
VGA
Multi-Scan
Monitor
3
4
MONITOR 1
MONITOR 2
1
2
Connect RS232
RS232 control can be achieved using a
separate user terminal or CPU with a
terminal program.
To make a terminal connection, connect a
serial cable (specifications on page 44)
between the user terminal and the 9 pin
DIN female connector on the VEEMUX-A
labeled "RS232". (See Fig. 3)
Figure 3- Connect user terminal for RS232 control.
If the Telnet Interface (page 14) or Web Interface (page 22) will be used, an Ethernet connection to the Local Area Network (LAN)
must be made using Cat5 cable with RJ45 connectors attached. Wiring between connectors should be straight throu gh (pin 1 to
pin 1, pin 2 to pin 2, etc..) Connect a Cat5 cable between the connector labeled "ETHERNET" and the LAN (see Fig. 4).
ETHERNET
NTI
1275 Danner Dr
Aurora, OH 44202
www.nti1.com
NETWORK
TECHNOLOGIES
INCORPORATED
Tel:330-562-7070
Fax:330-562-1999
R
S
2
3
2
RJ45 male
connector
Rear View of VEEMUX-A
AUDIO OUT (USER)
5
7
6
8
VIDEO 7
VIDEO 8
VIDEO 5
VIDEO 6
VIDEO 3
VIDEO 4
LAN
AUDIO IN (CPU)
5
1
3
2
4
VIDEO 1
VIDEO 2
MONITOR 7
MONITOR 8
MONITOR 5
MONITOR 6
7
8
MONITOR 3
MONITOR 4
6
3
4
MONITOR 1
MONITOR 2
1
2
Figure 4- Connect the LAN to the VEEMUX-A
Power Up
1. Plug the VEEMUX-A to an AC power outlet.
2. Turn ON power to the VEEMUX-A.
3. Turn ON power to any or all of the video and/or audio sources connected to the VEEMUX-A.
LED MATRIX
(not available on all models)
The LED Matrix is a grid of LEDs on the front panel of the VEEMUX-A. This grid is used to provide a visual indication of all
connections between video sources and destinations. It is not
(video source) is connected to an output (video destination), follow the LEDs down and to the right (respectively) until they
intersect. The illuminated LED at the point of intersection indicates the input is connected to the output by the VEEMUX-A.
OUT
IN
1234678
1
2
3
4
5
6
7
8
an indication of audio connections. To determine if an input
5
Figure 5- LED Matrix showing input 5 connected to output 5
6
Page 12
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
CONTROL OPTIONS
The VEEMUX-A Audio/Video Matrix Switch has four methods of control:
• Front Panel LCD with Keypad
• Directly via an RS232 interface
• Remotely via Ethernet
• Infrared Remote (optional)
Every unit comes standard with the Front Panel LCD with Keypad, RS232, and Ethernet connection built-in. If desired, the
Infrared Remote option may be requested at the time of the order. The Infrared Remote option requires the purchase of a
separate remote control device (Infrared transmitter) as well as an Infrared receiver to be installed in the VEEMUX-A. No software
is involved (see page 36 – Infrared Control). With the RS232 or WEB Interface options, there are no external d evices to be
purchased. NTI provides software commands as well as a test program to ensure the RS232 functions properly (see page 10 –
RS232 Control) and a graphic user interface for use with a RS232 or Ethernet connection.
Front Panel LCD with Keypad Control
The front panel keypad and LCD (drawing below) allow the user to view and change current aud io and video connections, adjust
audio volume and configure the RS-232 control interface. The keypad buttons perform the following functions.
ESC Escape back to the main display.
0 – 9 Used to enter numbers. ( # )
OUT Specifies output port
IN Specifies input port
ENTER Forces selection of single digit entries
Display next 4 connections
Display previous 4 connections
MENU Display the RS-232 menu. (See RS232 control on page 10.)
* Additional functions
OUT: 1 2 3 4
V
IN: 1 2 3 4
LCD WILL CYCLE TO DISPLAY A "v" FOR ALL VIDE O INPUTS FIRS T, THE N A "a" FOR ALL AUDI O INP UTS.
ESC
MENU
OUT
6
7890
1
IN
23
5
4
*
ENTER
Making Connections
The VEEMUX-A allows audio and video connections to be made concurrently or separ ately. In both situations, the output port
number must always be entered first.
• Connecting audio and video concurrently
When making this connection, any one of the following commands may be used:
1. <OUT>, Single digit output port number, <IN> or <ENTER>, Single digit input port number, <ENTER>.
Ex: <OUT> 3 <IN> 5 <ENTER>
2. Single digit output port number, <ENTER>, Single digit input port number, < ENTER>.
Ex: 3 <ENTER> 5 <ENTER>
3. Double digit output port number, Double digit input port number.
Ex: 03 05
All outputs can be connected to a single input by using <*>:
1. <*>, Single digit input port number, <ENTER>
Ex: <*> 5 <ENTER>
2. <*>, Double digit input port number
Ex: <*> 05
7
Page 13
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
•Connectingaudio only
To make an audio connection without changing the current video connection, use any of the follo wing commands:
1. <OUT>, <
Ex: <OUT> <
2. <OUT>, <▼>, <▼>, Double digit output port number, Double digit input port number.
Ex: <OUT> <
All audio outputs can be connected to one audio input by using <*>:
1. <*>, <
Ex: <*> <▼> <▼> 5 <ENTER>
2. <*>, <
Ex: <*> <▼> <▼> 05
• Connecting video only
To make a video connection without changing the current audio connection, use any of the following commands:
1. <OUT>, <
Ex: <OUT> <▲> 3 <IN> 5 <ENTER>
2. <OUT>, <
Ex: <OUT> <
All video outputs can be connected to one video input by using <*>:
1. <*>, <
Ex: <*> <
2. <*>, <▲>, Double digit input port number
Ex: <*> <
▼>, <▼>, Single digit output port number, <IN> or <ENTER>, Single digit input port number, <ENTER>.
▼> <▼> 3 <IN> 5 <ENTER>
▼> <▼> 03 05
▼>, <▼>, Single digit input port number, <ENTER>
▼>, <▼>, Double digit input port number
▲>, Single digit output port number, <IN> or <ENTER>, Single digit input port number, <ENTER>.
▲>, Double digit output port number, Double digit input port number.
▲> 03 05
▲>, Single digit input port number, <ENTER>
▲> 5 <ENTER>
▲> 05
Volume Control
The volume level can be adjusted on each output port.
•To increment <▲> or decrement <▼> the volume, use the following command:
<OUT>, <▼>, Double digit output port number, <▲> increment or <▼> decrement, <ENTER>
Ex 1: <OUT> <
▼> 03 <▲> <▲> <▲> <ENTER>
This will increment the volume by +6dB (2dB/ press).
Ex 2: <OUT> <
▼> 14 <▼> <▼> <ENTER>
This will decrement the volume by -4dB.
•To Mute, use the command:
<OUT>, <▼>, Double digit output port number, the <0> key, <ENTER>
Ex: <OUT> <
▼> 03 0 <ENTER>
This will mute output 3
•To Un-mute, use the instruction:
<OUT>, <▼>, Double digit output port number, the <1> key, <ENTER>
Ex: <OUT> <
▼> 03 1 <ENTER>
This will un-mute output 3
Memory Functions
There are 100 memory locations(0-99) available to save connection configurations. Location 0 is the power-ON default).
• Saving Connections
To save all current connections, use the following command:
<*>, <OUT>, Memory location, <ENTER>
Ex: <*> <OUT> 5 <ENTER>
• Restoring Connections
To restore connections from memory, use the following command:
<*>, <IN>, Memory location, <ENTER>
Ex: <*> <IN> 5 <ENTER>
Note: If the current switch configuration includes assigned Scan Mode dwell time values (page 9), to save the current
configuration be sure to assign a memory location to it. Otherwise, when the VEEMUX-A is powered OFF, all dwell
time values will be erased. Also, saving the configuration as memory location 0 will cause it to be the power-ON default
configuration.
Configurations that are saved into memory locations via
the keypad can be recalled via the web interface (page 20)
and vice versa.
8
Page 14
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
I
Menu Button
The Menu button is used to configure the RS-232 port.
•The baud rate is selected from the “Baud Rate Menu.” To access this menu, use the command:
<MENU>, the <1> key
Next, press the keypad number corresponding with the desired baud rate:
<1> – 9600
<2> – 4800
<3> – 2400
<4> – 1200
Ex: <MENU> 1 1
This will select 9600 baud
•To set the switch address, use the following instruction:
<MENU>, the <2> key, Double digit address (from 01 to 15- the default address is 01)
Ex: <MENU> 2 03
This will set the address at 03
Scan Mode
Scan Mode causes output ports (audio and video) to automatically switch from one audio and video input port to the next
consecutive audio and video input port after a specified period of time (referred to as the dwell time). Audio and video port
switching will continue indefinitely and no ports will be skipped, wheth er there are audio or video sources connected to them or
not. If desired, the VEEMUX can be configured to skip the scanning of specific ports using the RS232 Command Protocol (page
11) or Telnet (page 14) .
Dwell time settings can be any value from 0 seconds (000) to 255 seconds. A setting of 000 seconds (the default setting)
disables Scan Mode for that output port. If Scan Mode is disabled for a specific port number, then the video or audio to that
output port number will only change as decided by the administrator.
Note: While Scan Mode is enabled, audio and video ports of the same number will switch together. Independent control
of video and audio ports will be disabled. I.e., when video output 1 switches from input 1 to input 2, audio output 1
will also switch from input 1 to input 2.
To configure Scan Mode from the front panel LCD:
Press MENU, the following lines will be displayed:
1) Set Baud Rate
Press MENU again, the following line will be displayed:
Press 3 to select that menu item. The following request will be displayed:
Select Port
Select the output to be programmed using the numeric keys, then press ENTER. The display will show the current Dwell Time
value for that output and ask for a new value.
Using the numeric keys, enter a value between 0 and 255 and press ENTER. Leading zeros are allo wed (000) but the number
should not exceed 3 digits. The Scan Mode dwell setting value 0 will disable Scan Mode for that output port.
Scan Mode dwell time settings can also be configured through the RS232 Command Protocol (page 11), Telnet commands (page
14), or through the Web Interface (page 22).
NOTE: Scan Mode configuration settings can only be saved if they are assigned a memory location via the Keypad
Control (page 8). Otherwise when the power is cycled to the VEEMUX-A, all Scan Mode settings will be erased.
TIP: If the Scan mode settings are stored as memory location 0, they will be loaded each time the VEEMUX-A is powered
ON.
2) Set Unit Addr
3) Set Scan Mode
Current Time: 16
New Time:
NOTE: If Outputs Scanning Sequences (page 26)
Is enabled, Scan Mode as configured at the LCD
front panel will be disabled.
The disabled front panel Scan Mode feature will
be indicated by the message “SCAN SEQUENCE
S ACTIVE” on the LCD display.
9
Page 15
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
RS232 CONTROL
RS232 enables the VEEMUX to be remotely controlled via RS232. To control the VEEMUX via RS232 the user has three
options:
• write a program that runs on a PC using the Command Protocol (page 11)
• use the Matrix Switcher's Control Program (page 13) provided on the CD
• use the SerTest program (page 13) provided on the CD
Remote Connection
The RS232 Interface is designed to control the switch via serial (RS232) daisy chain connection from any host computer or other
controller with an RS232 communications port.
The pin outs for the DB-9 connector on the unit are as follows:
RS232 Connector (DB-9 FEMALE)
PIN SIGNAL FUNCTION
1 None no connection
2 TXD Transmit Data (RXD at host)
3 RXD Receive Data (TXD at host)
4 DSR Data Set Ready
5 GND Signal Ground
6 DTR Data Terminal Ready
7 CTS Clear to Send
8 RTS Request to Send
9 None no connection
On the DB-9 female connector, pins 4 (DSR) and 6 (DTR) are shorted and pins 7 (CTS) and 8 (RTS) are shorted. T herefore, host
handshaking is bypassed and TXD and RXD are the only active signals. A straight through DB-9 cable (not null modem) will work
for most CPUs. To daisy chain multiple units, use NTI Matrix-Y-1 "Y" cables, except for the last unit connected. (see Fig 6). For a
pinout of the Matrix-Y-1 cable, see page 45. For straight through cable pinouts applicable to various terminal types, see page
44.
Baud Rate
The unit powers up with a default baud rate of 9600 and a fixed data protocol of 8 data bits, no parity and 1 stop bit. The baud
rate is selectable through the "Baud Rate Menu". A data protocol of 8 data bits, no parity, and 1 stop bit is used in the daisy
chain communication.
Unit Address
To allow multiple units to be controlled from a single host port, the RS232 control interface is designed to allow "daisy chaining" up
to 15 units using the NTI Matrix-Y-1 "Y" cables. By setting the appropriate unit address with the keypad, each unit can be given a
unique address (1-15). Then the unit will only respond to commands on the bus if its address is embedded in the command. (See
Fig. 6.)
Host
CPU
Figure 6- RS232 Connections for Daisy-chain
RS232
Serial Port
RS232
NTI
SWITCH
First Unit
Matrix-Y-1
Matrix-Y-1Matrix-Y-1
RS232
NTI
SWITCH
Second Unit
RS232
NTI
SWITCH
Last Unit
10
Page 16
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Command Protocol
CPU controller commands supported by the unit are defined below. All commands must be terminated with a <CR> (carriage
return). When a command is sent, the entire string is echoed back along with a response from the addressed unit as shown in the
Command Definitions table (below). All characters in the command string are case sensitive (see Command Definiti ons table),
and all numbers below 10 must have a leading 0 (ex: 1 = 01).
Legend:
(All numbers must be two digits)
SW : Switch (01-15)
BR : Baud Rate Code (12,24,48,96)
VV : Volume Level (00-99, XX=UNSUPPORTED)
OP : Output Port (01-MAXOUTPUTS)
MU : Mute State (00=UNMUTE, 01=MUTE,
XX=UNSUPPORTED)
Command Definitions
Command String Good Response Description
CS SW,IP,OP *<CR> VIDEO Connect One Output/User Port To Input/CPU Port
CA SW,IP *<CR> VIDEO Connect All Output/User Ports To Input/CPU Port
RO SW,OP *<CR>IP<CR> VIDEO Read Connection For Output/User Port
AS SW,IP,OP *<CR> AUDIO Connect One Output/User Port To Input/CPU Port
AA SW,IP *<CR> AUDIO Connect All Output/User Ports To Input/CPU Port
AO SW,OP *<CR>IP<CR> AUDIO Read Connection For Output/User Port
AM SW,OP,MU *<CR> Set Mute State For Output/User Port
AV SW,OP,VV *<CR> Set Volume Level For Output/User Port
CC SW,MM *<CR>MM<CR> Save Matrix Connections Into Memory Bank xx
RC SW,LL *<CR>LL<CR> Restore Matrix Connections From Memory Bank
CB 00,BR None Change baud rate of serial line, BR=12(00),24(00),48(00),96(00)
RS SW *<CR> Internal Reset
RV SW,00 *<CR>string\0<CR> Read NTI Version String
RU SW *<CR>IP,OP<CR> Read Unit Size
AR SW,OP *<CR>MU,VV<CR> Read Mute, Volume For Output/User Port
MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED.
VV is a value between 00 to 99 (see chart page 12)
EA SW,ip *<CR> Set the IP address, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
EM SW,ip *<CR> Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field.
EG SW,ip *<CR> Set the default gateway, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
ET SW,timeout *<CR> Set the website timeout; timeout = numeric string of timeout in
RA SW * <CR>ip<CR> Read the IP address, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
RM SW * <CR>ip<CR> Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
RG SW * <CR>ip<CR> Read the default gateway, ip is in xxx.xxx.xxx.xxx format,
number of digits is minimum 1 and maximum 3 for each field
IP : Input Port (01-MAXINPUTS)
MM : Save Into Memory Bank (00-99)
LL : Load From Memory Bank (00-99)
<CR> : Carriage Return (Hex 0xD)
ip : IP address
AP : Audio Port
See chart on page 12 for values
Xx=00-99
Factory default is 9,600
Leading zeroes are accepted
Leading zeroes are accepted
Leading zeroes are accepted
seconds.
Leading zeroes are accepted
Leading zeroes are accepted
Leading zeroes are accepted
11
Page 17
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Command Definitions (Cont’d)
Command String Good Response Description
RT SW * <CR>timeout<CR> Read the website timeout; timeout = numeric string of timeout in seconds.
Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800
SS SW,00 *<CR> Disable Autostatus feature (see below)
SS SW,01 *<CR> Enable Autostatus feature (see below)
GO SW,OP *<CR>go
SW,OP,IP<CR>
GM SW,00 *<CR>go SW,OP,IP
(all ports)<CR>
GA SW,OP *<CR>go
SW,OP,AP<CR>
GB SW,00 *<CR>go SW,OP, AP
(all ports)<CR>
Ss SW,OP,dwt *<CR> Set value of Scan Mode dwell time (see page 9) for specific Output
dwt = 000-255 (seconds) 000= disable Scan Mode
Gs SW,OP *<CR>
DWT<CR>
Sa SW,OP *<CR> Set scan list of individual output to all inputs
Sc SW,OP *<CR> Clear scan list of individual output
S+ SW,OP,IP *< CR> Add individual input to Scan List of output
S- SW,OP,IP *<CR> Remove individual input from Scan List of output
Sx SW,OP *<CR>oooxoxxxoooo
xxx<CR>
If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch
memory, the command will be ignored. If the SW field corresponds to the unit address, but the syntax is wrong after this field, the
switch will answer with a bad response ?<CR>.
Set Volume Level For Output/User Port (for command string AV SW,OP,VV in chart above)
This command will set the volume of the specified AUDIO output/user port from a scale of 00 to 99, which represents a logarithmic
volume.
Serial Data (VV) Audio Volume
90 – 99 +10dB
80 0dB
60 -20dB
0 – 28 -52dB
Read connection of a Video Output Port to Video Input Port
Read connection matrix of all Video Output ports
Read connection of a Audio Output Port to Audio Input Port
Read connection matrix of all Audio Output ports
Read scan mode dwell time setting for an Output port
DWT values: 000-255 000= scan is disabled for the port
Inspect the Scan List of individual output (o=skip x=don't skip)
Autostatus
When Autostatus is enabled, any output-to-input connection change in the VEEMUX-A will cause an Autostatus message to be
sent via RS232 to the administrator. The format of the message would be "pc SW,OP:IP<CR>"
Example of an Autostatus message:
pc 01,01:04<CR>
which means "At the switch with unit address 01, the output (01) has changed connection to input 04."
Notes: Message to the administrator will be delayed by any RS232 traffic being received by the switch from the
administrator.
Autostatus must be disabled before using SerTest or the Matrix Switcher's Control Program (page 13).
By default, Autostatus is disabled and must be manually enabled. Autostatus is also disabled any time the power to the
VEEMUX-A is interrupted.
12
Page 18
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Matrix Switcher’s Control Program For Windows 9X, NT, 2000, XP, Vista and 7
The Matrix Switcher’s Control Program is an easy and powerful graphical program that controls NTI matrix switches through an
RS232 interface. The Matrix Switcher’s Control Program is downloaded by clicking on the link "Download Matri x Switcher’s
Control Program" found on the web page that appears when you insert the instruction manual CD into your CD ROM drive.
To install the Matrix Switcher’s Control Program after downloading
1. Locate the Setup.exe in the directory the program was downloaded to and double-click on it
2. Follow the instructions on the screen
The Matrix Switcher’s Control Program performs best on monitors set to a screen resolution of at least 800 X 600. Instruction for
using the Matrix Switcher’s Control Program is available by opening "MSCP Help" in the "NTI" program group once the program
has been installed and is open on the screen.
To open "MSCP Help" from the Windows desktop
1. Click on START
2. Click on PROGRAMS
3. Click on NTI
4. Click on MSCP Help
Note: While in Scan Mode, the video and
audio radio buttons shown on the Switch
page of the Matrix Switcher’s Control
Program may not be in sync with the
connection changes within the VEEMUX.
Connections will change without updating
the image on the screen.
SerTest- RS232 Interface Test Program
This software allows a user to test the functions of an NTI server switch, matrix switch or Multi-user/Multi-platform switch RS232
interface. The SerTest program is automatically loaded when installing the Matrix Switcher’s Control Program as described
above. The SerTest program, located in the NTI program group, generates a main menu with the 4 selections descr ibed below:
Main Options
• Matrix Operations
• Ethernet Operations
• Setup Options
• About SerTest
- send commands to the matrix unit.
- set Ethernet connection variables
- set COM port, baud rate, and unit address
- display the program version
Matrix Operations
Key Selection Description
1) Connect Video Output/User to an Input/CPU - connect an output to an input
2) Connect All Video Outputs/Users to an Input/CPU - connect all outputs to an input
3) Connect Audio Output/User to an Input/CPU - connect an output to an input (audio ports only)
4) Connect All Audio Outputs/Users to an Input - connect all outputs to an input (audio ports only)
5) Change Mute Status for Audio Output/User - mute or un-mute the Audio port output
6) Change Volume for Audio Output/User - change Audio port output volume
7) Read Connection for Video Output/User -read the connection of a specific video output
8) Read Connection for Audio Output/User -read the connection of a specific audio output
9) Read Mute and Volume for Audio Output/User - read the volume and the mute status of the specified output
(audio ports only)
a) Save I/O Connections into Unit Memory -save the connections into switch memory bank
b) Restore I/O Connections from Unit Memory -restore the connections from switch memory bank
c) Change All Units Baud Rate (9600/COM1:) -change RS-232 Baud rate of all switches
-the current baud rate and serial port are displayed in
parentheses
d) Reset Unit - send a reset command to the switch
- the current unit address is displayed in parentheses
e) Reset All Units - send an internal reset command to all switches
f) Read Unit Size - read the switch size (number of inputs and outputs)
g) Read Unit Version/Revision String -read a string containing the switch version, type, and size
h) Save All Units I/O Connections into Units Memory -save the connections into switch memory bank, command for all
switches
i) Restore All Units I/O Connections from Units Memory -restore the connections from switch memory bank, command for
all switches
13
Page 19
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Ethernet Operations
Key Selection Description
1) Set Unit IP Address - enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
2) Set Unit Subnet Mask
3) Set Unit Default Gateway - enter the desired default gateway
4) Set Unit Website Timeout - set the website timeout; timeout = numeric string of timeout in seconds
5) Read Unit IP Address - read the unit IP address in xxx.xxx.xxx.xxx format
6) Read Unit Subnet Mask - read the unit subnet mask in xxx.xxx.xxx.xxx format
7) Read Unit Default Gateway - read the unit default gateway in xxx.xxx.xxx.xxx format
8) Read Unit Website Timeout - read the current website timeout period in seconds
- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
4) set read timeout (5) - select the time period (in seconds) the SerTest will wait for an answer to a command
For any selection that requires user input, the user is prompted. When commands are sent to the matrix unit, the command string
and matrix unit responses are echoed to the screen. All commands generated by the program are formatted according to the
information provided in sections above. If any transmission problems are detected, an error message is displayed.
Press <Esc> or <Enter> to back out to the main menu and press again to exit.
- select PC serial port
- the current PC serial port is displayed in parentheses
- select PC serial port baud rate
- the current baud rate is displayed in parentheses
- select the unit address
- the current address is displayed in parentheses
- the current time period is displayed in parentheses
ETHERNET CONTROL
Telnet Interface-Port 2000
The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server
listens on ports 2000 and 2005. Port 2000 is for an operator telnet session while port 2005 (must be enabled) is intended for a
software control type session (see page 16). For operator telnet control using the telnet interface and the current IP address,
type the following in a command shell:
telnet 192.168.1.30 2000
The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.
The factory default password is "admin".
With a proper password sent the VEEMUX-A will respond with:
Password Successful
Connection Established
14
Page 20
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
The following commands are now available:
Command Reply Description
H(elp) or
h(elp)
CS nn,mm *<CR> Connect One Output nn To Input mm
CA nn *<CR> Connect All Outputs To Input nn
RO nn *<CR>mm<CR>
CC nn *<CR>nn<CR>
RC nn *<CR>nn<CR>
CB nn *<CR>
RV 00 *<CR>string<CR> Read NTI Version String
RU *<CR>nn,mm<CR>
RS *<CR> Reset Unit
Displays the list of commands Help
Read Connection For Output.
Returns the number of the input mm connected to output nn
Save Matrix Connections Into Memory Bank nn
nn should be between 00 and 99
Restore Matrix Connections From Memory Bank nn
nn should be between 00 and 99
Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)
Factory default is 9600.
Read Unit Size
Returns the number of inputs nn and the number of outputs mm
AS nn,mm *<CR> Connect audio inp ut nn to output mm
AA nn *<CR> Connect audio input nn to all outputs
AO nn *<CR>nn<CR> Read audio connection for output nn
AM nn,mu *<CR>
AV nn,vv *<CR>
Set mute state for output nn
mu(te State) = (00=UNMUTE, 01=MUTE)
Set volume level for output nn
vvis a value between 00 to 99 (see chart page 12)
Read mute, volume for output nn
AR nn *<CR>MU,VV<CR>
MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED.
VV is a value between 00 to 99 (see chart page 12)
Set value of Scan Mode dwell time (see page 9) for specific Output
Read set Scan Mode dwell time value (dwt) for specific Output (nn)
in seconds (see also "Scan Mode" on page 9)
Sa nn,mm *<CR> Set scan list of individual output nn to all inputs mm
Sc nn *<CR> Clear scan list of individual output nn
S+ nn,mm *<CR> Add input mm to Scan List of output nn
S- nn,mm *<CR> Remove input mm from Scan List of output nn
Sx nn *<CR>oooxoxxxooooxxx<CR> Display the Scan List of output nn (o=skip x=don't skip)
CP
<Ctrl>-<X>
(see note 4 below)
User is prompted to introduce the
password twice
Good Bye.
Connection to host lost.
Change password- five (5) characters minimum
Quit telnet session
Notes:
1. The commands must be typed exactl
2. If a mistake is made, the user must backspace to the beginning and completely retype the comma nd.
y as shown in the chart. The commands are case sensitive.
3. If a command is sent that the VEEMUX-A does not recognize or exceeds the configuration of the switch, the
reply "?" may be received. Check the command syntax and try again.
4. To quit the telnet session, press the keyboard keys <Ctrl><X>.
15
Page 21
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
>
Telnet Interface-Port 2005
For a software control type of telnet interface session (versus operator telnet control through port 2000 as described on page 14),
connect to the VEEMUX through the current IP address at port 2005. To do this, a connection to port 2005 must first be enabled
(see Web Setup on page 26). Then, with port 2005 enabled, use the command set below to control and acquire information from
the VEEMUX.
Notes:
• If Port 2005 connection is idle for 10 seconds it will disconnect
• Up to 2 active connections are allowed at the same time
• After establishing the connection, the unit will answer with *<CR>. If the connection fails or there are already 2
connections
Legend: (All numbers must be two digits)
OP : Output Port (01-MAXOUTPUTS)
IP : Input Port (01-MAXINPUTS)
<CR> : Carriage Return (Hex 0xD)
Command Summary
Command String Good Response Description
established, it will answer with ?<CR
RU<CR> ru OP,IP<CR> Read unit size
RO OP<CR> pc OP,IP<CR> Read connection for OP
CS OP,IP<CR> *<CR> Connect OP to IP
CA IP<CR> *<CR> Connect all outputs to IP
SS 01<CR> *<CR> Enable auto-status mode
SS 00<CR> *<CR> Disable auto-status mode
SX<CR> See details Examine connections
AO OP<CR> ac OP,IP<CR> Read audio connection for OP
AS OP,IP<CR> *<CR> Connect audio OP to IP
AA IP<CR> *<CR> Connect all audio outputs to IP
AV OP,VV<CR> *<CR> Set audio volume for OP
AM OP,MM<CR> *<CR> Set audio mute status for OP
AR OP<CR> ar OP:MM,VV<CR> Read mute and volume for OP
XX<CR> *<CR> Close connection
A <CR> (carriage return, 0x0D) is considered to be the end of the command string. If a string exceeds 16 characters, an end of
string will be inserted automatically to avoid buffer overflow. An eventual <LF> (line feed, new line, 0x0A) after a <CR> will be
ignored. A bad string will always be responded to with the ASCII character ‘?’ followed by a <CR>.
This command will read the size of the unit. The response returns the number of inputs and the number of outputs in two-digit,
ASCII code format. If the numbers are smaller than 10, the 1st digit is ‘0’.
This command will read the connection of an output port. The response returns the output port that is connected to the input port.
Output – 1st digit
Output – 1st digit
(0x30…0x32)
(0x30…0x32)
Output-2nd digit
(0x30…0x39)
Output – 2nd digit
(0x30…0x39)
‘,’
(0x2C)
Input – 1st digit
(0x30…0x32)
<CR>
(0x0D)
Input – 2nd digit
(0x30…0x39)
<CR>
(0x0D)
CS- Connect Output Port to Input Port
Command:
Byte 1 By te 2 Byte 3 Byte 4 Byte 5 Byte 6Byte 7 Byte 8 Byte 9
‘C’
(0x43)
Response:
‘S’
(0x53)
Space
(0x20)
Output – 1st digit
(0x30…0x32)
Byte 1 Byte 2
‘∗’
(0x2A)
This command connects the specified input port to the specified output port.
<CR>
(0x0D)
CA- Connect All Output Ports to Input Port
Command:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
‘C’
(0x43)
‘A’
(0x41)
Space
(0x20)
Response:
Byte 1 Byte 2
‘∗’
(0x2A)
This command connects all output ports to the specified input port.
<CR>
(0x0D)
Input – 1st digit
(0x30…0x32)
Output – 2nd digit
(0x30…0x39)
Input - 2nd digit
(0x30…0x39)
17
‘,’
(0x2C)
Input –1st digit
(0x30…0x32)
<CR>
(0x0D)
Input –2nd digit
(0x30…0x39)
<CR>
(0x0D)
Page 23
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
SS_01- Enable Auto Status Mode
Command:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
‘S’
(0x53)
‘S’
(0x53)
Space
(0x20)
‘0’
(0x30)
‘1’
(0x31)
<CR>
(0x0D)
Response:
Byte 1 Byte 2
‘∗’
(0x2A)
Auto status mode is disabled by default whenever the connection is established, and this command must be entered to enable it.
When auto status mode is enabled, a message will be sent whenever an input/output connection changes from any source. The
format of this message is given in the table below. The first two numeric digits are the output port number and the two after the
colon are the number of the input port that is now connected to it.
This command will read the connection of the desired audio output port. The response returns the audio input port that is
connected to that audio output port.
This command sets or clears the mute status of the specified audio output port. A mute status of 00 indicates that the port is not
muted, while a status of 01 indicates that the port is muted.
<CR>
(0x0D)
Output – 2nd digit
(0x30…0x39)
‘,’
(0x2C)
‘0’
(0x30)
Mute Status
(0x30 or 0x31)
<CR>
(0x0D)
Terminate telnet session
Command:
Byte 1 Byte 2 Byte 3
‘X’
(0x58)
Response:
Byte 1 Byte 2
‘∗’
(0x2A)
The unit will respond with ‘*’<CR> and close the connection, terminating the telnet session. The unit is then available for future
connections.
This command will read the volume and mute status of the desired audio output port. The response returns the audio output port
and its mute status and volume.
‘R’
(0x52)
‘r’
(0x72)
Space
(0x20)
Space
(0x20)
Volume – 2nd digit
(0x30…0x39)
Output – first digit
(0x30…0x32)
Output – 1st digit
(0x30…0x32)
Output – 2nd digit
<CR>
(0x0D)
Output – second digit
(0x30…0x39)
(0x30…0x39)
‘,’
(0x2C)
<CR>
(0x0D)
‘0’
(0x30)
Mute Status
(0x30 or 0x31)
‘,’
(0x2C)
21
Page 27
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Web Interface
A user may control the connections of the VEEMUX-A using a Web Interface via any web browser (see page 1 for web supported
browsers). With the VEEMUX-A connected to a LAN through an Ethernet cable, a user can access the web interface controls
inside the VEEMUX-A.
FYI: To quickly locate a VEEMUX-A on the LAN and edit the IP address settings, use the Device Discovery Tool (page
35).
To access the web interface, type the current IP address into the address bar of the web browser.
Address
To open a SSL-encrypted connection, type:
Address
You will be prompted to accept a certificate. Accept the NTI certificate.
A "Welcome Page" will appear.
Figure 7- Web interface Welcome page
http://192.168.1.30
https://192.168.1.30
Enter the Password
Click on a link to the left to be prompted for a username and password. To change the password, see page 33.
User Name = Administrator (upper case letter for "A" only)
Password = admin (lower case letters only)
Note: The browser must be configured to accept cookies
in order for the user to successfully make use of the web
interface.
Figure 8- Web interface Login Prompt
If you are not the Administrator, access to the VEEMUX may be limited. Contact the VEEMUX administrator for your individual
username and password.
For information on setting up as many as 15 additional users, see page 27.
As described on the following pages, each link will enable different areas of control for the VEEMUX-A.
22
Page 28
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Main Menu
The VEEMUX main menu provides control over all functions of the switch. The administrative
menu includes options not available to other users with limited privileges.
When logged in as a user other than the Administrator, only the VIDEO SWITCH, AUDIO
SWITCH, CHANGE PASSWORD, HELP, and LOGOUT options will be available.
Figure 9- Administrator Menu
Video Switch Page
User Video Switch Page (more limited
control- non-accessible ports are
grayed-out. )
(User Main Menu)
Figure 10- Web interface Video Switch page
Administrative users will have full access to the Video Switch page (above) which displays the active connections
(shown in orange). This page enables the user to manually control the audio and video or just the video
connections of the VEEMUX-A. (To change audio connections separately, see page 19.) Up to 10 different
connection configurations can be saved and later recalled by any connection method. Output Scanning
Sequences (page 30) for each output can also be enabled. Standard Users have more limited control.
Configuration control and Sequencing are only available to the Administrator.
23
Page 29
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Note: If changes are made using the keypad (page 7) or by another user through the web interface, you
must refresh the screen using your browser to see those changes.
Note: Configuration 0 will be automatically loaded when the VEEMUX-A is powered up.
To change a connection, click on the radio button (square image with circle in the center) that intersects the input
and output columns. A black dot will be placed in the circle to indicate the selection. Then press the Submit
button. The display will be reloaded with the selections changed to orange to indicate they are now active. Multiple
connections can be changed simultaneously.
To quickly clear the selected radio buttons
button has not already been pressed with the selections made.
To quickly connect all outputs to a single input, choose the desired input from the "Set all Outputs to Input" dropdown list and press the Submit button.
Note: If radio buttons are selected in addition to using the "Set all Outputs to Input" option, the selections
made by the "Set all Outputs to Input" will take precedence when the Submit button is pressed. Selections
that conflict with it will be ignored.
Note: Scanning sequences that are enabled for an output through th e web interface, either at the Video
Switch Page or at the Output Scanning Sequences page (page 30) will disable Scan Mode for that output as
configured through the LCD menu (page 7).
FYI: See page 22 for an example of using the Outputs Scanning Sequen ces feature.
To change video only, or audio and video
leave the "Video + Audio" block empty (to effect only
video) or use the mouse to place a check in the box
shown to the right (to effect audio and video
connections). With a change of status, press Save
to have it take effect.
press the Clear Changes button. This will only work if the Submit
, either
For the Administrator Only:
To save a configuraton
desired slot (numbers 0-99) to save the active
The webpage configuration that loads after a Save is the configuration that was actually saved.
To load a saved configuration
desired configuration. Then press the Load button. The VEEMUX-A will make the connections and the screen will
refresh to show the connections associated with that configuration selection.
Configurations that are saved into memory locations via the keypad (pg. 8) can be recalled via the web interface and vice versa.
, from the Stored Configurations user interface, use the drop-down list to select the
configuration into and press the Save button.
Note: This will save the currently active
VEEMUX-A. If changes have been made in the web interface
without first pressing the Submit button, those changes will not
yet be part of the active
Note: If changes to the active configuration have been made by
another user prior to saving the
current connection selections, the changes made by the other
user will be saved as the configuration.
, from the Stored Configurations user interface, use the drop-down list to select the
configuration.
configuration on the
24
Page 30
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Audio Switch Page
To change audio connections only, the
Audio Switch page (right) enables the user
to control the audio connections
independently of the video connections.
Note: If Scan Mode is enabled for the
output port being connected to,
changes to that output port connection
will not be accepted.
Figure 11- Web interface Audio Switch page
Using the same methods of control described for the Video Switch page (page 23) the user can control the audio
connections made between ports on the VEEMUX-A. Additionally, the user can mute any output port or raise and
lower the volume at each output port.
Using the chart below, apply the value for the desired level of volume for each output port.
Value Audio Volume
90 – 99 +10dB
80 0dB
60 -20dB
0 – 28 -52dB
Place a checkmark in the Mute box for any output port where no volume is desired.
25
Page 31
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Setup Pages
These settings enable the user to configure the VEEMUX-A web interface connection. This change will take a few
seconds and automatically redirect the user to the IP address specified.
Note: Since the webserver will be restarting all active connections will be logged out.
The Website Timeout option controls how long an inactive web connection will stay logged in. Any change to the
Website Timeout configuration takes effect immediately.
The “Telnet configuration” block enables the VEEMUX-A to receive commands on port 2005 in addition to port
2000. For more on telnet use, see “Telnet Interface- Port 2000” on page 14.
Figure 12- Web interface Setup page
Figure 13- Web interface Serial Setup page
Changes to the Serial Address and Serial Speed (Figure 13) do not require a reset and will take effect
immediately.
26
Page 32
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
User Management
The Administrator can assign usernames and passwords to up to 14 users. Once assigned, the Administrator can control which
ports a user will have access to. Under the ADMINISTRATION menu, select “USER MANAGEMENT”.
Figure 14- Administration menu
Up to 14 unique user accounts can be configured. Up to 15 simultaneous users (including the Administrator) can be logged in at
the same time, and the same user account and password can be logged into from more than one location.
Note: The more users that are logged in, the slower the VEEMUX-A will respond to changes in its settings.
Add User
To add a user, select “Add user” to open a configuration window.
Figure 15- Add User page
Enter a username (1- 16 characters), a password (at least 5 characters and up to 16- case sensitive), and retype the password.
Place a checkmark in each box associated with an Input Port or Output Port that this user should have access to.
Click on “Add User” to finish, or “Reset” to start over.
To quickly provide access to all ports, click on “Add User with Full Access”.
27
Page 33
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Edit User
To Edit a User, select “EDIT USER” from the USER MANAGEMENT section of the menu.
Figure 16- Edit User settings
From the Edit User page, the Administrator can change all user settings or delete the user altogether.
Just as “Submit- Full Access” quickly provides access to all ports for a user, “Submit-No Access” quickly removes access to all
ports for a user.
28
Page 34
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Input Names
The Input Names pages (Video and Audio) enable the
Administrator to change the names of the video and audio
input ports displayed on the Switch page. To change an
input port name, enter the name of the port for the desired
input port number, and press "Save".
Note: Only the changes to the port directly to the left
of the Save button will be saved. All other changes to
ports without pressing the port's respective Save
button will be discarded. All port names must be no
more than 12 characters in length and only
alphanumeric characters may be used.
Figure 17- Web interface Video Input Names page
Output Names
From the Administration menu, the Video or Audio Output
Names page can be displayed. (Selected separately from the
menu.) These pages enable the Administrator to change the
names of the output ports displayed on the Switch page. To
change an Output Name, enter the name of the port for the
desired output port number, and press "Save".
Note: Only the changes to the port directly to the left of
the Save button will be saved. All other changes to ports
without pressing the port's respective Save button will be
discarded. All port names must be no more than 12
characters in length and only alphanumeric characters
may be used.
Figure 18- Output Port Names
29
Page 35
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Outputs Scanning Sequences
Figure 19- Outputs Scanning Sequences page
The Outputs Scanning Sequences page (accessible only to the Administrator) displays the configuration of an automatic switching
sequence from input (video source) to input for each output (monitor).
The page displays:
output number being configured
the Scanning Sequence function status for that output
the Scan Mode status of each input (ON/OFF)
the length of time in seconds (dwell time) that each input will be viewed when connected
The output selection at the top of the page can be changed to any output to display the Scan Sequence Input selections and dw ell
times for that output.
The inputs and the amount of time that each will be viewed (0-32000 seconds) can be set to cycle sequentially for each connected
output. If an input is set to 0 seconds, the sequence status will display “OFF”, and the input will be omitted from the scanning
sequence. To include an input in the sequence, enter a dwell time period from 1-32000 seconds, and press Apply.
To quickly clear all dwell time settings, press the Clear All button at the bottom of the page. All sequence settings will chan ge to
“OFF” and all dwell time settings will change to 0.
To enable the scanning sequence for the output shown, place a checkmark in the “Sequence Enable” block.
Tip: To quickly enable the scan sequence for multiple outputs, use the “Sequence Enable” blocks found on the Switch
Page (page 18).
Note: If only 1 input is set to Sequence “ON”, then the output connection to that input will not change when the Scanning
Sequence is enabled.
Note: If the scanning sequence for an output is enabled th rough the web interface, then the Scan Mode for that output
as configured through the LCD menu (page 9) will be disabled.
30
Page 36
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Example of using Outputs Scanning Sequences
Problem: A synchronous scan is desired for all outputs with a dwell time of 30 minutes per input, and no two outputs should be
looking at the same input at any given time.
Solution:
1. Set the dwell time for all inputs listed in each output at 180 seconds (30 minutes). Press “Apply”.
2. Go to the Video Switch page (page 18) and set each output to an input of the same number (1 to 1, 2 to 2, 3 to 3, etc..).
Click on “Submit” at the bottom of the Video Switch Page to submit selections and establish a connection and starting
point for the scanning sequence. (Blocks shown in yellow in the third image indicate connections made.)
3. Click on the “Sequence Enable” box for each output (from the Video Switch Page).
4. Click on “Submit” again to begin the scanning sequence for each output.
From the moment the configuration is submitted, a synchronous scan will begin on all outputs. Each output will connect to its
respective input for 30 minutes. After 30 minutes, the outputs will each switch to the next consecutive input and remain
connected for 30 minutes. This cycle will continue indefinitely until sequencing is disabled.
Step 1- setup dwell times
Step 4- Click on “Submit” to begin
Step 2- setup starting point for scan and cl ick “Submit”
Step 3- enable the scanning sequence
31
Page 37
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Update Firmware
For updating the Ethernet
Control, use this section and
insert the file v1_x.bin
For updating the Front Panel
LCD, use this section and insert
the file rmtlcd_va_1_x. hex
Figure 20- Web interface Upda te Firmware page
The Update Firmware page (located in the main menu under "ADMINISTRATION") shows the current version of the
firmware for the Web interface (Figure 20-upper) and for the Front panel (Figure 20-lower) and enables the Administrator to
update the firmware of the VEEMUX-A.
WARNING: Failure to carefully follow these directions can permanently damage the VEEMUX-A. Please read these
directions in full before continuing. Do not, under any circumstances, reset or power-down the VEEMUX-A while the
firmware is being updated. Do not attempt to update the firmware if a power-failure is likely.
Note: The Firmware can only be updated from the non-secure (http) website. If you attempt to access this page from the
secure (https) website, you will be automatically redirected to the non-secure site.
To update the firmware:
1. Contact NTI for the latest firmware file and copy it to your computer.
2. On the Update Firmware page, browse to the firmware file.
3. Press Update Firmware (for the Ethernet Control) or Update Front Panel Firmware (for the LCD).
Note: If an update is attempted using the wrong firmware for the section an error message will be received. No update
will occur.
4. Wait for the following message to appear (may take several minutes):
Flash of new image completed:
The system will automatically restart.
5. The VEEMUX-A will restart itself in 10 seconds, logging out all connections. After approximately 40 seconds,
the VEEMUX-A will be ready to resume operation.
If a message appears stating that the Upload has failed, or that a non-fatal error has occurred:
1. Ensure that the file being uploaded is the NTI firmware file.
2. Repeat the process from step 2 above.
Note: The following message does not indicate that damage to the product has occurred.
If a message appears stating that there has been a fatal error:
1. DO NOT RESET OR POWER-DOWN THE VEEMUX-A.
2. Repeat the update process from the first step 2 above.
3. If you get another Fatal Error message, call NTI tech-support at 1-800-742-8324 or 330-562-7070.
FYI: The VEEMUX-A should continue to run normally unless it is reset. However, damage may have occurred
to the web server firmware that will prevent the product from starting up correctly.
Upload Succeeded
32
Page 38
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Change Password Page
Figure 21- Web interface Password page
Use this page to change the password for accessing the web interface. (This password is also used for the telnet
interface.) Be sure to make note of the new password exactly as it is case sensitive. The password must be
between 5 and 16 characters in length and can be alphabetical or numeric.
Help Page
This page explains the purpose of each of the other pages in the VEEMUX-A web interface.
Update Web Server
RS232 interface, or via the front panel of the VEEMUX-A. All users presently connected will be disconnected and
must log back in after using this command.
Click on this selection to globally update the Web Server to any settings that have been changed though Teln et, the
Figure 22- Updating the Web Server
33
Page 39
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Logout Page
Figure 23- Web interface Logout page
This page will enable the user to end the session and close the web interface connection. Click on the "Press Here
to Continue Logout" button to exit the VEEMUX-A web interface.
Note: The connection will timeout automatically after a preset period of inactivity, configurable on th e Web Setup
page.
34
Page 40
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
DEVICE DISCOVERY TOOL
In order to easily locate NTI Devices on a network, the NTI Device Discovery Tool may be used. A link to the Discovery Tool is
provided on the web page that appears when you insert the instruction manual CD provided into your CD ROM drive. Either click
on the link or browse the CD to locate the NTIDiscover.jar file. The Discover Tool can be run from the CD or it can be saved
to a location on your PC. Either way, to open it just double-click on the file NTIdiscover.jar . This will open the NTI Device
Discovery Tool.
Note: The Device Discovery Tool requires the Java Runtime Environment (version 6 or later) to operate. A copy of Java
version 6 is provided on the CD and a link to the web page from which it can be downloaded and installed is also on the
CD.
Note: The computer using the Device Discovery Tool and the NTI Device must be connected to the same physical
network in order for the Device Discovery Tool to work. If no devices are found, the message “No Devices Found” will
be displayed.
Tip: If your Windows program asks which program to open the NTIDiscover.jar file with, select the Java program.
Figure 24- Device Discovery Tool
Click on the “Detect NTI Devices” button to start the discovery process. After a short time, the tool will display all NTI devices on
your network, along with their network settings.
How to Use the Device Discovery Tool
To Change a Device’s Settings
on the Enter key, or the Submit button on that row. If the tool discovers more than one device, the settings for all devices can be
changed and you can click on the Submit All button to submit all changes at once.
To Refresh the list of devices, click on the Refresh button.
To Blink the LEDs of the unit, click on the Blink LED button (This feature is not supported on all products.) The Blink LED
button will change to a “Blinking….” button. The LEDs of the unit will blink until the Blinking… button is clicked on, or the NTI
Device Discovery Application is closed. The LEDs will automatically cease blinking after 2 hours.
To Stop the LEDs of the unit from blinking, click on the Blinking… button. The Blinking…. button will change to a Blink LED
button.
, within the row of the device whose settings you wish to change, type in a new setting and click
35
Page 41
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
INFRARED CONTROL
(Optional)
The IRT-64X32 (or IRT) is an infrared remote transmitter that enables the user to control up to four (4) NTI VEEMUX Audio/Video
Matrix switches via an infrared receiver from up to 50 feet away (with an unobstructed view). The IRT is battery-powered and
always ready to use. The IRT will have a blank display unless an action is being selected by the user. The IRT enables the user
to make connections between any input (video source) and any output (display device) on up to four (4) separate switches
Note: Multiple switches that are located close to each other and are to be individually controlled must b e p re-configured
(by NTI) to be identified by the IRT as switches #1, #2, #3, or #4. Please ask your salesperson to have switches
configured accordingly at time of order. Unless otherwise specified, by default, all IRT-enabled switches will be
configured as switch #1.
Materials included:
• IRT-64X32 Infrared Remote Transmitter for audio/video matrix switches
• (2) AA Cell Batteries- installed
NTI
Network Technologies Inc
R
.
Features And Functions
KEYPAD
¾ Buttons Numbered 0-9 – Used for port selection
¾ OUT – Pressed to validate and transmit the Output selection
¾ IN – Pressed to validate and transmit the Input selection
¾ SYS – Pressed to choose the switch to be controlled or to configure the maximum
number of inputs/outputs
LCD Display
¾ The first digit of the LCD will display the number of the switc h to be controlled foll owed by the decimal point. This way the
user will always know which switch will be effected by the IRT.
¾ The last two digits in the LCD represent 1) the desired input or output port to be connected or 2) the desired switch to be
controlled when changing switches.
¾ The "Lo Batt" decimal point will illuminat e when the user should change the batteries.
¾ The LCD will automatically power-down after 30 seconds of non-use and power-up with the press of any button.
Represents switch to be controlled
SW
Represents Input or
Outp ut
Lo Batt
36
SW
1
456
789
OUTIN
Lo Batt
23
0
SYS
IRT-64X32
Page 42
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
How To Use The IRT
The IRT-64X32 enables the user to control the connections of up to 32 input ports and 16 output ports on up to four (4) separate
NTI audio/video matrix switches. When any key is pressed, the IRT will power ON. A number key should always be pressed
first unless a change to the configuration is desired (see "Set Configuration" on page 39). When a number key is pressed the
LCD will display that number blinking. What to press next depends on what action is desired;
• change the switch to be controlled
• change the output port
• change the input port
Note: The user must always change or confirm the output port first and the input port second
If the "SYS", "IN" or "OUT" key is pressed first, the LCD will display the current switch followed by the decimal point and an error
signal "EE". The error signal will display because there is no number to be displayed. A number key must always be pressed
before a "SYS", "IN" or "OUT" key is pressed.
Exception: The "SYS" key is pressed first when setting the configuration. (See page 39)
Power ON with SYS, IN or OUT keys Power ON with "2" key
Change the Switch
Press the number of the switch to be controlled. The number selected will be blinking in the last digit.
FYI: If the user realizes that an invalid number has been introduced before
buttons, a correction can be made by pressing the correct number. If the correct number is a single digit, it must be
preceded by a "0" to make the correction.
Press the "SYS" key. The blinking number will become blank and the switch number will update.
Note: If the number entered is larger than 4, when the "SYS" key is pressed the LCD will display the current switch and
the error signal "EE".
pressing either the "SYS", "IN", or "OUT"
37
Page 43
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Change Output Port
Press the desired port number. If there is no change in the desired output port, the output port must still be selected. As the
digits are selected, the last number entered will blink. The LCD will also display the current switch number followed by the
decimal point.
With the desired port number selected, point the IRT at the switch/receiver and press the "OUT" button to transmit the selection
and make the change. The blinking number in the LCD will stop blinking. An LED on the receiver will illuminate.
FYI: If the switch did not receive the data the LED will not illuminate. The user can re-send the same data by pressing
the "OUT" button again. The LED at the receiver will illuminate to indicate a completed transmission from the IRT..
Note: If the number introduced is larger than the maximum number of outputs the IRT is configured for, then once the
"OUT" key is pressed the LCD will display the current switch and the error signal "EE".
Change Input Port
Press the desired port number. As the digits are selected, the last number entered will blink. The LCD will also display the
current switch number followed by the decimal point.
With the desired port number selected, point the IRT at the switch/receiver and press the "IN" button to transmit the selection and
make the change. The blinking number in the LCD will stop blinking. The LED at the receiver will go OFF.
FYI: If the switch did not receive the data the LED will not go OFF. The user can re-send the same data by p ressing the
"IN" button again. The illuminated LED on the receiver will go OFF when the received data is complete.
Note: If the number introduced is larger than the maximum number of inputs that the IRT is configured to control, then
once the "IN" key is pressed the LCD will display the current switch and the error signal "EE".
38
Page 44
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Set Configuration
The IRT-64x32 factory default setting is 32 inputs and 16 outputs. When the batteries are changed the setting wi ll return to the
default value. At the default setting the IRT has the ability control any matrix switch with up to 32 inputs and 16 outputs without
changing the configuration. However, when controlling smaller switches without changing the configuration it is up to the user to
press valid number(s). To avoid confusion, it is recommended to configure the IRT to communicate with the largest switch to be
controlled.
To change the maximum number of inputs or outputs:
1. From power-down state (blank LCD) press and hold the "SYS" button for at least 3 seconds. The LCD will first display an
error message but after 3 seconds the letter "c" will display:
2. Enter the number of inputs or outputs. As the digits are entered, they will be displayed and the last one entered will blink.
Note: Only the inputs OR the outputs may be configured each time the configuration function is used. To perform
another configuration operation the user must start again at "Set Configuration" step 1.
3. Accept the choice by pressing the "IN" button for setting inputs, or the "OUT" button for setting the outputs. The LCD will not
blink anymore and will display “i” (for inputs) or "o" (for outputs) and the number.
Notes:
- The maximum nu mb er of inputs and outputs that can be entered is 32 and 16 respectively. If the user introduces a
number larger, the display will show an error signal ("c.EE") and the maximum number will remain at the last valid
value configured.
- If more than one switch is being controlled, the IRT should be configured for the largest switch. It is up to the user
to introduce valid numbers to the smaller switches when making selections.
39
Page 45
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
Battery Replacement
The IRT has a low-battery indicator to let the user know when it is time to change the batteries. The right-hand decimal point in
the LCD display will illuminate (see illustration below). This will stay illuminated while th e IRT is in use until the batteries are
changed or the battery charge is too low for the IRT to operate.
To Change The Batteries:
1. Remove slide cover on rear of unit.
2. Remove old batteries carefully.
3. Insert (2) new “AA” cell batteries.
4. Replace slide cover on unit.
SW
Lo Batt
5. Reset the configuration if a range other than the default setting is desired.
Specifications
• 50 feet maximum operating range between the transmitter and the front of the NTI switch / infrared receiver.
Note: Line of sight between IRT and receiver must be unobstructed.
• Select up to 16 outputs
• Select up to 32 inputs
• Operates with (2) “AA” batteries.
• "Lo Batt" decimal point in LCD will illuminate to indicate a low battery when the battery voltage drops to approximately 2.25
volts.
Troubleshooting
PROBLEM SOLUTION
IRT is not selecting output
IRT is not selecting input
• Check battery
• Make sure you are using the correct IRT for the switch. (Check model number
• The IRT may be configured to control the wrong switch or the wrong size of
• Check battery
• The IRT may be configured to control the wrong switch or the wrong size of
on the front of the IRT.)
switch (see "Set Configuration" on page 39)
switch (see "Set Configuration" on page 39)
40
Page 46
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
DDC SUPPORT
(Optional)
DDC information allows the CPU to automatically select the optimal resolution for the monitor by receiving, at pow er up,
information from the monitor concerning its resolution specifications.
When DDC Support is installed, the DDC information is acquired from the monitor by the VEEMUX-A switch when the VEEMUX-A
is powered-up. A monitor with DDC support must be connected to MONITOR 1 for this to occur. The DDC information will
be made available at every CPU port.
The DDC information can also be acquired by pressing the DDC button located on th e front of the switch. This button allows the
monitor configuration to be changed without powering down the switch.
Notes:
1. All monitors connected to the VEEMUX-A switch with DDC support must be able to support at least the maximum
resolution of the DDC monitor connected to '"MONITOR 1".
2. In order for the CPU to correctly receive the DDC information from the switch at boot-up, the switch must be
powered up before all attached CPUs.
41
Page 47
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
RS232 UPGRADE OF THE FRONT PANEL LCD FIRMWARE
The firmware in the front panel LCD can be upgraded to include the latest features availabl e using either the RS232 port
(below) or Ethernet Control (page 22). Follow the procedure below to use the RS232 method to u pdate the Front Panel LCD
firmware in the VEEMUX-A. To prepare, first download the rmtlcd_va_1_x. hex file (x= the current firmware version) from
the NTI Video Matrix Switch website http://www.networktechinc.com/vmtx.html
The following will be needed:
1 PC running HyperTerminal (or other terminal program) equipped with a 9 pin or 25 pin serial port
o
o A VEEMUX-A made to use the Firmware Upgrade feature
o 1 serial cable wired straight through to connect your PC's serial port to the “RS232” port on the VEEMUX-A
(see cable specifications on page 44)
o A firmware file for a VEEMUX-A downloaded from www.networktechinc.com
Procedure:
1. Power OFF the VEEMUX-A.
2. Connect the null modem cable between the serial port on the PC and the “RS232” port on the VEEMUX-A.
.
3. Use HyperTerminal to prepare to connect to the VEEMUX-A (using settings 9600 baud, 8-N-1 no flow). Make sure
HyperTerminal has been configured for connection through the correct COM port on the PC.
4. With the HyperTerminal window open, hold the spacebar and apply power to the VEEMUX-A. A command menu and the
Command prompt (>) should appear.
Copyright 2006 Network Technologies Inc
Flash Loader Utility v1.0
H Display this help menu
C Clear flash
L Load flash with .hex file
Command>
Note: Commands are not case-sensitive (for example, 'h' or 'H' will execute the help command), and the <Enter> key
is not required to execute a command.
If the Flash Loader Utility menu does not appear, the VEEMUX-A you have may have been made prior to the release of
this product change. To verify this, with the VEEMUX-A powered ON, at the HyperTerminal window enter the following
command:
RV 01 (be sure to include the space)
The following revision string will appear:
$date: 2006/04/17
If the date shown is before
20:20:59 $$revision: 1.1 $$IN: 08 $$OUT: 04 $
2006/04/17, then the VEEMUX-A firmware cannot be upgraded using this procedure.
42
Page 48
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
5. Press <L> to load the firmware (hex) file. This will prepare the file for transfer to the VEEMUX-A.
If the file fails to load, press the <C> key to clear the old firmware, and press <L> to load it again.
6. When the message “Start sending file via Xmodem protocol..”' appears, the VEEMUX-A is waiting for the Firmware file to
be uploaded.
A box or some other characters may be displayed repeatedly on the line below this message while the VEEMUX-A waits;
this is normal.
7. Click “Transfer” > “Send File...” from the HyperTerminal menu bar
8. Select “Xmodem” from the Protocol drop-down menu,
9. Click “Browse”. Go to the directory containing the firmware to load into the VEEMUX-A. Select to highlight the hex file,
click “Open”, then click “Send”.
10. A window will appear displaying information about the upload operation, including the upload process. It may take a few
seconds for the upload to begin.
DO NOT DISRUPT POWER while the firmware is uploading to the VEEMUX-A.
11. When the upload is completed, the command prompt will return. Power the VEEMUX-A OFF, then ON again. Upgrading
is complete, and the VEEMUX-A is ready to use.
43
Page 49
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
RS232 CONNECTION CABLES
Pinout of RS232 port on VEEMUX-A
The VEEMUX-A RS232 serial port is a DB-9F (female) connector configured as a DCE (data communication equipment) port. The
RS232 port interface signals are listed below, including equivalent CCITT V.24 identification, and signal direction:
DB-9F
pin #
1 N/a N/a N/a No connection -2 TxD BA 103 Transmit Data Output
3 RxD BB 104 Receive Data Input
4 DSR CC 107 Data Set Ready Input
5 SG AB 102 Signal Ground –
6 DTR CD 108.2 Data Terminal Ready Output
7 CTS CB 106 Clear T o Send Input
8 RTS CA 105 Req uest To Send Output
9 N/a N/a N/a No connection --
On the DB-9 female connector, pins 4 (DTR) and 6 (DSR) are shorted and pins 7 (RTS) and 8 (CTS) are shorted. Therefore, CPU
handshaking is bypassed and TXD and RXD are the only active signals.
Common
name
EIA
name
CCITT
name
Function Direction
Specifications for Straight-Through Serial Cable for CPU Connection
VEEMUX-A to PS2 or SUN CPU (9 PIN) VEEMUX-A to MAC CPU (25 PIN)
The Matrix-Y-1 cable is used to connect multiple VEEMUX-A units in a daisy-chain to a single terminal. (See RS232 Control on
page 10. )
Arrows indicate signal direction.
Wiring Schematic of Matrix-Y-1 cable
9D Female9D Male9D Male
(Unit #1)
23
33
555
(Source)
(Unit #2)
Not connected to
source connector
22
7
Jumper
8
1
Jumpers
4
6
RACK MOUNTING INSTRUCTIONS
This NTI switch was designed to be directly mounted to a rack. It includes a mounting flange to make attachment easy.
Install 4 cage nuts (supplied) to the rack in locations that line up with the holes (or slots) in the mounting flange on the NTI switch.
Then secure the NTI switch to the rack using four #10-32 screws (supplied). Be sure to tighten all mounting screws securely.
Do not block power supply vents in the NTI switch chassis (if provided) . Be sure to enable adequate airflow in front of and
behind the NTI switch.
Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.
10-32
Rack Screws
(supplied)
Rack
Cage Nuts
(supplied)
45
Page 51
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
SPECIFICATIONS
DESCRIPTION SPECIFICATION
Operating temperature -18 °C - 55°C (0°F - 131°F) (17-90% non-condensing RH)
Storage temperature -30°C - 60°C (-20°F-140°F) (17-90% non-condensing RH)
Power requirements 110 or 220VAC @ 50 or 60Hz
Fuse protection 2A 240VAC Fast-blo
Video Connectors 15HD female
Maximum Resolution 1920 x 1200 @ 85Hz
Video Signal : Video
Bandwidth
Sync
Ethernet Connector RJ45 female, 10BaseT
RS232 Connector DB9 male, 300-9600 bps
Audio Connector 3.5mm jack
Audio Signal Type Stereo unbalanced
Audio: Frequency response
THD + N
S/N
Crosstalk
Audio Input: Impedance
Max. input level
Audio output: Gain adjustment
Impedance
RGB analog (75 ohms, 0.7 Vp-p)
200MHz (typ) or greater
H/V separated (TTL), composite, sync-on-green
20Hz to 20kHz, +/- 0.5dB
0.01% @ 1kHz
>90 dB
> 85 dB @ 1kHz
10kOhm
1Vrms or 2.5Vp-p
No Video - Check power – power ON, power cable connected
- Check video cabling – make sure cables are secured
- Check connections – make sure you’re connected to an active input
No Audio - Check power – power ON, power cable connected
- Check audio cabling – mak e sure audio plugs are fully inserted
- Check connections – make sure you’re connected to an active input
- Check volume – make sure the output you are checking is un-muted and turned up to an audible
level (pg 12).
SAFETY STATEMENTS
Grounding
These products have protective earth ground terminals and are built with full attention to consumer safety. There must be an uninterruptible safety earth ground between the main power source and the product's power cord or supplied power cord set.
If ever the possibility exists for the grounding protection to have been reduced in any way, disconnect the power supply until the
grounding connection has been fully restored.
Servicing
NTI products are not intended to be serviced in the field and contain no user-serviceabl e parts. In the event repair is needed, all
servicing must be performed by factory trained and authorized service personnel. Only those items specifically ide ntifi ed in this
manual (if any) may be adjusted by the user of this product and adjusted only as instructed in this manual.
memory, 8
mount to a rack, 45
password
password-change, 33
Scan Mode, 9
Scanning Sequences, 30
serial setup, 26
servicing, 47
Software control, 16
specifications, 46
specifications-cables, 44
Switch page, 23
Telnet, 6
Telnet Interface, 14
Telnet password
Telnet-Port 2005, 16
troubleshooting, 47
unit address, 10
Update Front Panel Firmware, 42
User management, 27
user name
username and password, 22
web browsers, 1
, 2, 22
, 2
, 2
47
Page 53
NTI VEEMUX AUDIO/VIDEO MATRIX SWITCH
WARRANTY INFORMATION
The warranty period on this product (parts and labor) is two (2) years from the date of purchase. Please contact Network
Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at http://www.networktechinc.com
for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns.
Man069 Rev. 2/5/14
48
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.