100-240VA C / 50-60Hz / 850W
Fuse 5*20mm / T6,3A
Speaker
OUT
O
I
Signal ON
Line IN Subwoofer
ON
Protect
Clip
LevelSignal Source
EQ Pink
EQ Line
Preset 3
Preset 4
Preset 5
All information subject to change without notice.
Warning LEDs, Troubleshooting
Warning LED Issue Root cause Countermeasure
Protect Amplifier output is muted The output current of the amplifier is A.
too high
Temperature inside amplifier too high B.
The amplifier output is oscillatingC.
A. Verify the connected cable / load
Switch OFF the amplifier for >20 sec.
B. Let the amplifier cool down
Verify that the built-in fan is operating
C. Check the compatibility of the speaker
(i.e. verify the load impedance)
Clip Distorted output signal The input signal level is too high Reduce the Line IN signal volume
(none) Amplifier audibly reduces the
output volume (
Note: this is a
protection feature
)
D. The input signal is overloading the
amplifier
E. The impedance of the output load is
too low (i.e. output power too high)
D. Select another test signal
Reduce the Line IN signal volume
E. Verify or modify the load
Check for external short circuit
Mains power switch Mains power socket
Output for dodec loudspeaker
PA3 rear panel
Mute / Unmute
amplifier output
Input for external
signal generator
Signal selection
Subwoofer ON
Output level control
Output for subwoofer(
factory use only
)
PA3 front panel
www.nti-audio.com Page 2 / 5