NTI GF200, NPE-240A Quick Installation Manual

GF200
Quick Installation Guide
STEP 1 - BEFORE INSTALLING
Read both the GF200 and NPE-240A Installation manuals before installing.
This product must be installed and serviced by a licensed plumber, a licensed gas tter, or a professional service technician. NTI is not liable for any damages or defects resulting from improper installation.
When applicable, the installation must conform with Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 and/or CAN/CSA Z240 MH Series, Mobile Homes.
Safety
WARNING
Follow all local codes and/or the most recent edition of the National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA, or the Natural Gas and Propane Installation Code in Canada (CAN/CGA B149.1).
GF 200
Installation Manual
C learan ces [D
ég age ments
]
GF 200
C O M BINAT ION GAS WAT
ER HEA
T ER / CENT R AL
AIR HEA
T ING
*COMBINA
ISO N CHAU
F F EE­EAU INST
ANT ANE / GENERAT
EUR
D' AIR CH
AUD
#### #
Ma de in C an a
da
Fab r
iq u
es a u C an a
d
a
Seria
l Nu m b er :
#### #
#### # # ####
###
##
# ####
AIR FL OW
T h is ap p lia n ce is ap p ro v ed f o r u p f
lo w in stal latio n .
C ette f our n ai s e e s t a ppro v e e pou
r l '
i
ns tal l
a ti on et c i
r
c ul a ti on d'ai r as c ende nte.
Min . clearan
ce t o c o mb u st ib le co n st ru ct io n : ( i
n .) see d iag ram .
Dega
gemen
ts mi ni mum en
tr e l 'app arei l et des
c ons tru c ti ons c ombu
s ti bl es
( PO.)
Ven t
cl earan ce to co m b u st ib le co n stru ct io n ( in .) : 0
D egag ement d
e v ent c ons tr uc ti on s c ombu
s t
i
bl es ( PO.): 0
* Min s ervice cleara n ce
* D egag emen
t mi n. p our fi n s d '
e ntr e ti en pou r
l e s i ns tal l
a ti o ns
C: CO
MBU ST IBLE F
LOORS
Re fer t o Ins tal l
a ti o n Manu
al f or s er v i
c e c l
ear anc e de tai l
s
0
0
0
0
2 4* C
Elec t
rical Rat i
n g / Car
ac t
er i
s t
i
qu e El e c
tr i
q ue
VOL T S F R EQ . PHASE
MCA
MA
X. CKT . BR K
IN DO O R BLOWER MOT
OR
12 060 Hz
1
1 3 A
9 .6 A
3/ 4
F LA
HP
C e
rtifi e
d by
C e
r
t
ifie p ar
N Y The rma l I n
c
. 3 0 S to ne ga te D r
.,
S a
int Jo hn , N B ,
E 2H 0A4, C a
na d
a
Mo d el
[Mo de l
e]
F u el
[Gaz ]
A lt itu d e , ft
[Al ti tude , pi ]
In p u t
, MBH
[Entr ée, k W]
Mi n
Max
Sp ac
e Hea t
in g
Ca p
ac it y, M BH
[Cap
a c i
te d e
Cha
u ffag e , k W]
Nat.
19 .9 [5.83]20
0 [58 .61]
0 ­ 4500
*
T GF
-20 0
L P
D HW Hea
tin g
Cap acit y, MBH
[
Capac
i
te de DHW
C hauffa
ge, k W]
80 [23
.45]
200 [58.61
]
F AC T ORY SET
F O R N AT U RAL G A S
F i
el d c o nv er ted to Pr
op an e Gas
CO NF I
G U R ÉE A L '
USIN E POUR GAZ
NAT UREL
Co nv er ti e au pro pane
s ur pl ac e
Date:_
___ _ ____ _ ____ ____ _____
____ _____
D ate:__
____ ____
_____
____ ____ _____
__ __
Gas Press
u re [Pr
e s s i
on du
G a z ]
Natu
ral
[Natu
r
el ]
Pro p an e
Maxim u m In let Gas Pressu
re
[Pr es s i
on max i
ma l
e d '
e ntré e du gaz ]
Min im u m In let Gas Pressu
re [Pr
e s s i
on mi
ni mu m d' entr ée d u gaz
]
Man i
fo ld Pres s u re
[ Pres s i
on d'admi
s s i
on]
10 .5 " WC
3.5" W C
-
0.58 " WC
13 "
WC
8" W C
-
0. 02 / -
0.78" WC
I
m p o rt an t I n fo rm at io n
[Rens
i
gnes men t
s Im porta
nts ]
Us e for Natur
al or L P G a s o nl y .
Max i
mum
W a ter Pr es s u re = 1
50 ps
i
Max i
m um Stati
c Pres s ure =
0.8 IN
. W.C.
Max i
mum Inl
et Wat
er T empe
r
atur e = 18
0° F
T h i
s app l
ian c e mu s t b e i n s ta l
led i n ac c or d anc e
wi th l oc al c od es , i f any ; i f
not, fol l
ow ANSI
Z 223 .1/NF
PA 54 o
r
CAN
/CSA B14
9.1, N
atura l
Gas and Pr opa ne In s ta l
l
ati on Co
de, a s
a ppl i
c abl e.
Uti l
i
s e z d es gaz Nat
ur el ou LP s eulement.
Pr es s i
o n d'eau
max
. = 150
l b /po²
Pr es s i
on s t
ati q ue max
. = 0 .8 PO. D'EAU
T emp.
max i
mal e d'
ea u d'en
tr ée = 180°
F
Cet a
ppar ei l
do i
t ê
tr e i ns tal l
é c on formé
ment au
x c od es
l
oc aux , l e c as éc héan
t ; s i
n on, s ui v e z AN SI Z 22
3.1 /
NF PA 54
o u CAN
/ CSA B14
9.1, g
az natur el et
prop ane C ode d '
i
ns
tal l
a ti on , l e c a s éc h éan t.
F OR YOUR
SAF ET Y
Do not s
tor e or us e gas
ol i
n e or other
fl a mmabl
e v ap or s a nd l i
q ui d s i n th e v i
c i
n i
ty
o f thi s or an y o ther appl i
a nc e.
POUR VOT RE SÉC
URIT É
Ne p as entr epos er
ou uti l
i
s er d' es s en c e ou d'au
tres
v apeu r
s et l i
qu i
d es
i
nfl ammab
l
es à pr ox i
mi té de c et
app ar ei l
ou de
tout
autr e appa
rei l
.
St an d ard ANSI Z
21.1
0.3 / C SA 4.3
Gas Water
Hea te rs , Vol ume III
Stora
ge Water
Hea ters , wi th In put R
ati ngs Abov
e 75 ,00 0 BT U
pe r
Hou r, Ci r
c ul ati ng a nd Ins ta ntaneo
us
CSA C2
2.2 N o . 23 6 / UL 199 5
Heat i
ng and C
ool i
ng Equi pmen
t
*
R e
f
e
r to w a
te r
h e
ate r r a
tin g
pla te u nd e
r
a c
c
ess p an el on t
he o pp o
s
ite si d
e of th is c a
b
in
et.
Orifice
s ne ce ss ary fo r
L P c o
nv e
r
s
io n are pro v
ide d
.
Failu r
e
to u se t
he co r
re ct ga s c a
n
c au se pro bl e
ms
w hic h ca n re s
ult in d ea th ,
s
eriou s inju r
y
o r
p r
o
p
erty
d ama g
e
Le s inje c
t
ures n e
ce ss
a
ires a l
a
co nv ersio n a
u
G P L
s o
nt
f
o
u
r
n
is.
Le f
ait de n
e pa s
u tilis
er le b on g az p eu t c a
u
se r de s
p
r
ob le mes qu i p e
u
ve n
t
me ne r a la mo rt, c au s
e
r de s b
e
ssu res
g
r
a
ve s o u
e nd omma ge
r la prop r
ie te
24* 24*
W a t
er h ea t
e r ratin g p lat e lo ca ted u n d er a cces s p a n el o n o p
p o s ite s id e o f
c ab in et.
20 A
DO NOT install in areas with excessively high humidity or poor air quality (dust, particulate matter, etc.)
STEP 2 - INSTALLING
1
Unpacking
GF 200
Installation Manual
Cleara nces [Dégage
ments]
GF 200
COMB INATIO N GAS WATER
HEAT ER / CEN
TRAL AIR HEA
TING
*C OMBINA
ISON CH
AUFF
EE-EAU I
NSTANT
ANE / GEN
ERATEU
R
D'AIR
CHAU
D
#####
M
ad e in Can
ada
Fa brique s
au Cana da
Serial Number:
#####
#####
#####
#####
#####
AIR FLO
W
Th is appliance is ap
proved fo
r upflo w install ation.
Cette fournaise
est approvee pou
r l'ins tallation et c
irculation
d
'air asc
endente.
Min. clearance to comb
ustible co
nstruct ion: (in .) see diagra
m.
Dega gements m
inimum
entre l'a
ppareil et des
construction
s combusti
bles (PO.)
Ve nt clearance to
combu stible cons
truction (in.): 0
D
egagement de v
ent construct
ions combus
tibles (PO.
): 0
* Min service clearan
ce
*
Degagement
min. pour
fins d'ent
retien pour les
installatio
ns
C
: COMBUSTIBLE
FLOORS
Refer t
o Installation Manual for ser
vice cleara
nce details
0
0
0
0
24* C
Electr ical Rating
/ Caracte
ristique El
ectrique
VOLTS FREQ.
PHASE
MCA
MAX.
CKT. BR
K
IND OOR BLO
WER MOTOR
12060 Hz
1
13 A
9
.6 A
3/4
F
LA
HP
Certi fied b
y
Certifie
p
ar
NY The r
m
al I n
c. 30 Ston
ega t
e
Dr. , Sain t
John, N
B, E2H 0A4
, Ca nad a
Model
[Modele]
Fuel
[Gaz ]
Alt itude, ft
[Alti tude, pi]
Inpu t, MB H
[Entrée, kW] Min
Max
Space H e
a
ting
Capacity
,
MBH
[Capaci
te de
C
hauffage, kW]
N
at.
19.9 [5.83]200 [58.61]
0 - 4500*
TGF-20
0
LP
D
HW He ating
Capacity,
MBH
[Capacite de D
HW
Chauffage, kW
]
80 [23.45]200 [58.61]
FAC TORY SET
FOR N ATUR AL GAS
Field c
onverted to P
ropane Gas
CON FIGURÉE A L'US
INE POU
R GAZ NATUR EL
C
onvertie au pr
opane sur pl
ace
Date:_______
_
_
___________________
_
_
__
Date:_____
_
_
______________________
_
_
_
Gas Pressu
re [Press
ion du Gaz]
N
atural [Natur
el]Propane
Max imum Inle
t Gas Pressu
re [Pressi
on maxim
ale d'e
n
t
rée du gaz]
Minimum
Inlet G a
s
Pressure [Pre
ssion mini
mum d'entrée du gaz]
Ma nifold Pre
ssure [Pressi
on d'admission]
10.5" WC
3.5" WC
-0 .
5
8" WC
13" WC
8" WC
-0.02 / -
0
.
78" WC
Impo rtant In formati on [Rensign
esments Importants]
Use for Natural
or LP Gas onl
y.
Maximum Water Pressur
e = 150 psi
Maximum Stati
c Pressur
e = 0.8 IN.
W.C.
Maximu
m Inlet Wate
r Tempe
rature = 180°F
This appl
iance mu
st be installed
in accordance
with local
codes, if any; if
not, follow AN
SI
Z223.1/N
FPA 54 or C
AN/CSA
B149.1, Natura
l
Gas and Propane Instal
lation Code, a
s
applic
able.
Ut ilisez des ga
z Naturel
ou LP seulement.
Pres sion d'ea
u max. = 150 lb/po²
Pre ssion statique
max. = 0.8 PO. D'EAU
Temp. ma
ximale d'eau d'entrée =
180°F
Cet appare
il doit être i
nstallé conformément aux c
odes
locaux
, le cas éc
héant ; sinon, sui
vez ANSI Z
223.1 /
N
FPA 54 ou C
AN / CS
A B149.1, gaz nature
l et
prop ane Code d'installation
, le cas échéa
nt.
FOR YOUR SA
FETY
Do no
t
s
tore or use gas
oline or other
flammable vapors
and liquids in
the vicinity
of this or any othe
r appliance.
POU R VOTR E SÉCURITÉ
Ne pas e
ntreposer ou util
iser d'e
ssence ou d'autres
vapeurs
et liquides i
nflammabl
es à proxim
ité de cet
appareil ou de t
out autre apparei
l.
Standard AN
SI Z21.10.3 / C
SA 4.3
G
as Water H
eaters, Vol
ume III Storage
Water
He aters, with
In put Ratings
Above 75,000 BTU
per Hour, C
irculati
ng and Instantaneous
CSA C22.2 No. 236
/
UL 1995
Heating and C
ooling Equipm
ent
*
Refer t
o
water hea
te
r
rating pla
t
e
u
nde r access
pan el on the o ppo site side
o
f this cab i
n
et.
Ori fice s ne ce ssary for LP conversi
o
n are provide
d.
Failure to use t
h
e c o
r
re
ct g
as can cau se p
roblem
s
wh ic
h
can result i
n
d
eath, se
ri
o
us in
jury or prop
erty
da mag e
L
es inje ctures necess
a
ir
e
s
a la c o
nversi o
n au GP
L so nt
fourn i
s.
Le fait
d
e ne pa
s utilis e
r
le bo n gaz peu
t causer des
proble mes qui pe
uvent men
er a la m
ort, causer des bess
u
res
g
r
a
v
e
s
ou e
ndo mma ge r
la prop
ri
e
te
24* 24*
Water h eater rating
plate locat
ed und er access pan
e
l
on opp osite side
o
f cabinet.
20 A
KIT BOX
GF200
Manual Packet
LP Conversion Kit
Spare Parts Kit
Installation Kit Box
When you unpack the GF200, you will nd the
following items inside the appliance. Check for each of the following items before installing the appliance.
1
2
Location Requirements
Install the appliance in an area that allows for service and maintenance access to utility connections, piping, ductwork, lters, and traps. Based on the installa­tion location, ensure the following clearances are maintained:
Minimum clearance:
Clearance to combustibles
Recommended service clearances
Top 9 in as required
Back
Front *  (or as required)*
Side (w/o connections)  as required
Side (w/ connections)  as required
Side (Blower access)  24 in
Bottom
When locating the appliance prior to completing the ductwork and plumbing, it is essential that sucient space be allotted for the installation and mainten­ance of components such as:
• Flow switch
• Thermostatic Mixing Valve (TMV)
• Pressure Relief Valve (PRV)
• Shut o and drain valves
• Expansion tank (optional)
• Condensate drain (and optional pump)
• Return air lter
• Circulating blower
* No clearance required to front of unit if obstruction is removable (such as a door or access panel). 24 inch clearance if obstruction is permanent.
3
Checking the Rating Plate
Clearances [Dégagements]
IFW-80-200
COMBINATION GAS WATER HEATER / CENTRAL AIR HEATING
*COMBINAISON CHAUFFEE-EAU INSTANTANE / GENERATEUR
D'AIR CHAUD
#####
Made in Canada
Fabriques au Canada
Serial Number:
#####
#####
#####
#####
#####
AIR FLOW
This appliance is approved for upflow installation.
Cette fournaise est approvee pour l'installation et circulation d'air ascendente.
Min. clearance to combustible construction: (in.) see diagram.
Degagements minimum entre l'appareil et des constructions combustibles (PO.)
Vent clearance to combustible construction (in.): 0
Degagement de vent constructions combustibles (PO.): 0
* Min service clearance
* Degagement min. pour fins d'entretien pour les installations
C: COMBUSTIBLE FLOORS
Refer to Installation Manual for service clearance details
0
0
0
0
24* C
Electrical Rating / Caracteristique Electrique
VOLTS FREQ. PHASE MCA MAX. CKT. BRK
INDOOR BLOWER MOTOR
12060 Hz
1
13 A
9.6 A
3/4
FLA
HP
Certified by Certifie par
NY Thermal Inc. 30 Stonegate Dr., Saint John, NB, E2H 0A4, Canada
Model
[Modele]
Fuel
[Gaz]
Altitude, ft
[Altitude, pi]
Input, MBH
[Entrée, kW] Min
Max
Space Heating Capacity, MBH
[Capacite de Chauffage, kW]
Nat.
19.9 [5.83]200 [58.61]
0 - 4500*
IFW-80-200
LP
DHW Heating Capacity, MBH
[Capacite de DHW
Chauffage, kW]
80 [23.45]200 [58.61]
FACTORY SET FOR NATURAL GAS
Field converted to Propane Gas
CONFIGURÉE A L'USINE POUR GAZ NATUREL
Convertie au propane sur place
Date:________________________________
Date:________________________________
Gas Pressure [Pression du Gaz]
Natural [Naturel]Propane
Maximum Inlet Gas Pressure [Pression maximale d'entrée du gaz]
Minimum Inlet Gas Pressure [Pression minimum d'entrée du gaz]
Manifold Pressure [Pression d'admission]
10.5" WC
3.5" WC
-0.58" WC 13" WC
8" WC
-0.02 / -0.78" WC
Important Information [Rensignesments Importants]
Use for Natural or LP Gas only.
Maximum Water Pressure = 150 psi
Maximum Static Pressure = 0.8 IN. W.C.
Maximum Inlet Water Temperature = 180°F
This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1/NFPA 54 or CAN/CSA B149.1, Natural Gas and Propane Installation Code, as applicable.
Utilisez des gaz Naturel ou LP seulement.
Pression d'eau max. = 150 lb/po²
Pression statique max. = 0.8 PO. D'EAU
Temp. maximale d'eau d'entrée = 180°F
Cet appareil doit être installé conformément aux codes locaux , le cas échéant ; sinon, suivez ANSI Z223.1 / NFPA 54 ou CAN / CSA B149.1, gaz naturel et propane Code d'installation, le cas échéant.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ou utiliser d'essence ou d'autres vapeurs et liquides inflammables à proximité de cet appareil ou de tout autre appareil.
Standard ANSI Z21.10.3 / CSA 4.3
Gas Water Heaters, Volume III Storage Water Heaters, with Input Ratings Above 75,000 BTU per Hour, Circulating and Instantaneous
CSA C22.2 No. 236 / UL 1995
Heating and Cooling Equipment
* Refer to water heater rating plate under access panel on the opposite side of this cabinet.
Orifices necessary for LP co
nversion are provided.
Failure to use the correct gas can cause problems which can result in death, serious injury or property damage
Les injectures necessaires a la conversion au GPL sont fournis.
Le fait de ne pas utiliser le bon gaz peut causer des problemes qui peuvent mener a la mort,
causer des bessures
graves ou endommager la propriete
24* 24*
Water heater rating plate located under access panel on opposite side of cabinet.
20 A
Rating Plate, *Plaque Signalétique
Direct Vent Automatic Instantaneous Water Heater *Chauffe-eau instantané automatique à évent direct For Indoor, Outdoor or Manufactured Home (Mobile Home) Installation *Pour installation dans une maison préfabriquée (mobile)
Navien, Inc. 20 Goodyear, Irvine, CA 92618 Tel: 1-800-519-8794
Orifices necessary for LP conversion are provided. *Les injectures nécessaires à la conversion au GPL sont fournis. Failure to use the correct gas can cause problems which can result in death, serious injury or property damage. *Le fait de ne pas
utiliser le bon gaz peut causer des problèmes qui peuvent mener à la mort, causer des blessures graves ou endommager la propriété.
Consult your installation manual for more information. *Consultez votre manuel d’installation pour plus d’information. Suitable for combination water (potable) heating and space heating and not suitable for space heating applications only.
*Convient au chauffage combiné de l’eau (potable) et des locaux, mais non au chauffage des locaux seulement.
This appliance is certified for use at altitudes up to 4,500 ft (1,370 m) in accordance to the latest CAN/CGA 2.17-High Altitude Installation procedures at normal manifold pressure. For installation instructions at altitudes higher than 4,500 ft, please contact Navien. *Cet appareil
est certifié pour une utilisation à des altitudes de 0 à 4,500 pieds (1,370 m) conformément aux toutes les procédures d’installation à haute altitude CAN/CGA 2.17 à une pression normale. Pour les installations à élévations en haut de 4,500 pieds, appeler le bureau de Navien.
This appliance must be installed in accordance with local codes, or in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the CSA B149.1, Natural Gas and Propane Installation Code. *Cet appareil doit être installé selon les règlements
locaux, ou en l’absence de tels règlements, selon le National Fuel Gas Code, ANSI Z223.1/NFPA 54, ou les, Code d'installation du gaz natural et du propane, CSA-B149.1.
Model No., *Numéro de modèle
NPE-210A
Max. Input Rating, *Entrée GPL max.
180,000 Btu/h
Recovery Rating, *Calibre de recouvrement Max. Inlet Gas Pressure, *Pression max. de gaz d’entrée Min. Inlet Gas Pressure, *Pression min. de gaz d’entrée Manifold Pressure, *Pression d’admission Electrical Rating, *Régime nominal électrique Max. Water Pressure, *Pression d’eau max.
Type of Gas, *Type de gaz NG Min. Input Rating, *Débit calorifique max.
19,900 Btu/h
265 Gallons/Hour, *gallons/heures
10.5 Inches W.C. *pouces W.C.
3.5 Inches W.C. *pouces W.C.
-0.36 Inches W.C. *pouces W.C. AC *c.a. 120 Volts 60Hz, less than 2 amperes, *Utilise moins de 2A 150 psi *lb/po2 ANSI Z21.10.3 · CSA 4.3-2011
FOR YOUR SAFETY *POUR VOTRE SÉCURITÉ
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other gas appliances. *Ne rangez
pas et n'utilisez pas d'essence ou d'autres liquides ou vapeurs inflammables près de cet appareil ou de tout autre appareil électroménager.
Clearances [Dégagements]
GF 200
COMBINATION GAS WATER HEATER / CENTRAL AIR HEATING
COMBINAISON CHAUFFEE-EAU INSTANTANE / GENERATEUR
D'AIR CHAUD
#####
Made in Canada
Fabriques au Canada
Serial Number:
#####
#####
##### #####
#####
AIR FLOW
This appliance is approved for upflow installation.
Cette fournaise est approvée pour l'installation et circulation d'air ascendente.
Min. clearance to combustible construction: (in.) see diagram.
Dégagements minimum entre l'appareil et des constructions combustibles (PO.)
Vent clearance to combustible construction (in.): 0
Dégagement de vent constructions combustibles (PO.): 0
* Min service clearance
* Dégagement min. pour fins d'entretien pour les installations
C: COMBUSTIBLE FLOORS *Refer to Installation Manual for service clearance details
0
0
0024*
C
Electrical Rating / Caractéristique Électrique
VOLTS
INDOOR BLOWER MOTOR
120 60 Hz
1 12 A
9.6 A
3/4
RATED AMPS HP
Certified by Certifie par
NY Thermal Inc. 30 Stonegate Dr., Saint John, NB, E2H 0A4, Canada
Model
[Mod
èle]
Fuel
[Gaz]
Altitude, ft
[Altitude, pi]
Input, MBH
[Entrée, kW]
Min
Max
Space Heating Capacity, MBH
[Capacité de
Chauffage, kW]
Nat.
19.9 [5.83] 200 [58.6]
0 - 4500*
GF 200
LP
80 [23.5]
FACTORY SET FOR NATURAL GAS
Field converted to Propane Gas
CONFIGURÉE À L'USINE POUR GAZ NATUREL
Convertie au propane sur place
Date:________________________________ Date:________________________________
Gas Pressure [Pression du Gaz]
Natural [Naturel] Propane
Maximum Inlet Gas Pressure [Pression maximale d'entrée du gaz]
Minimum Inlet Gas Pressure [Pression minimum d'entrée du gaz]
Manifold Pressure [Pression d'admission]
10.5" WC
3.5" WC
-0.58" WC
13" WC
8" WC
-0.02 / -0.78" WC
Important Information [Rensignesments Importants]
Use for Natural or LP Gas only.
Maximum Water Pressure = 150 psi
Maximum Static Pressure = 0.8 IN. W.C.
Maximum Inlet Water Temperature = 180°F
This appliance must be installed in accordance
with local codes, if any; if not, follow ANSI Z223.1/NFPA 54 or CAN/CSA B149.1, Natural Gas and Propane Installation Code, as applicable.
Utilisez des gaz Naturel ou LP seulement.
Pression d'eau max. = 150 lb/po²
Pression statique max. = 0.8 PO. D'EAU
Temp. maximale d'eau d'entrée = 180°F
Cet appareil doit être installé conformément aux codes
locaux, le cas échéant ; sinon, suivez ANSI Z223.1 /
NFPA 54 ou CAN / CSA B149.1, gaz naturel et
propane Code d'installation, le cas échéant.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
POUR VOTRE SÉCURITÉ
Ne pas entreposer ou utiliser d'essence ou d'autres
vapeurs et liquides inflammables à proximité de cet
appareil ou de tout autre appareil.
Standard ANSI Z21.10.3 / CSA 4.3
Gas Water Heaters, Volume III Storage Water Heaters, with Input Ratings Above 75,000 BTU per Hour, Circulating and Instantaneous
CSA C22.2 No. 236 / UL 1995
Heating and Cooling Equipment
* Refer to water heater rating plate on the opposite side of this cabinet.
Orifices necessary for LP conversion are provided.Failure to use the correct gas can cause problems
which can result in death, serious injury or property damage.
Les injectures nécessaires à la conversion au GPL sont
fournis.
Le fait de ne pas utiliser le bon gaz peut causer des
problèmes qui peuvent mener à la mort, causer des blessures graves ou endommager la propriété.
24*
24*
Water heater rating plate located on opposite side of cabinet.
20 A
FREQ.
PHASE MCAMAX. CKT. BRK.RATED AMPS
15 A
Part # 85477
The GF200 is congured for Natural Gas from the factory. If conversion to Propane Gas is required, the conversion kit supplied with the water heater must be used.
• Before connecting the gas supply, determine the gas type and pressure for the water heater by referring to the rating plate. Use only the same gas type indicated on the rating plate. Using a dierent gas type will result in abnormal combustion and malfunction of the water heater. Gas supplies should be connected by a licensed professional only.
• The appliance and its gas connection must be leak tested before placing the appliance in operation.
• The water heater cannot be converted from natural gas to propane or vice versa without the supplied gas conversion kit. Do not attempt a eld conversion of the water heater without a the gas conversion kit. Doing so will result in dangerous operating conditions and will void the warranty.
NTI is not liable for any property damage and/or personal injury resulting from improper conversions.
WARNING
4
Return Air Ducting
The return air may be delivered to the appliance via:
a) either side;
b) the back;
c) the bottom; or
d) any combination thereof, provided, in
all cases, that access to at least one side door remains clear (24” min.) for blower access and maintenance.
MAX CUTTING
BOUNDARY
18” x 18”
(324 sq. in.)
MAX
CUTTING
BOUNDARY
14.5” x 24.5” (355 sq. in.)
Side Back Bottom
In all installations, an appropriate air ltration system is recommended and must meet test requirements in UL 900. Failure to install and properly main­tain such a system could lead to damage to and/or premature failure of the space heating components.
In all cases, care must be taken to ensure that return ducting is sealed against the inlet, such that the entire air steam is directed through the air lter. Failure to do so could cause damage to the air moving equipment and clogging of the heating and/or cooling coils.
NOTE: For details and recommendations on side, back or bottom return ducting see GF200 Installation Manual.
5
Venting
Max length: 150’
Max length: 60’
1
2
8
Max number of
elbows: 8
Max number of
elbows: 6
1
2
6
3” Venting
1 in (25 mm) min.
Combustion Air
Vent
Maintain 12” min. clearance above highest anticipated snow level or grade.
Combustion Air
Combustion Air
Vent
Maintain 12” min. (18” min. for Canada) clearance above highest anticipated snow level.
Max. 24” above roof.
Vent
Combustion Air
2” Venting
Vent Termination Options
Concentric Vent Terminations
12 in (300 mm) min. *
12 in (300 mm) min.
12 in (300 mm) min.
36 in (900 mm) min.
Horizontal Vent Termination
Interior View
Exterior View
Vertical Vent Termination
12” Min from any obstruction above, below, left or right.
Exhaust Vent Materials
From factory, the GF200 operates at water temperatures exceeding 150°F, resulting in the potential for exhaust temperatures to exceed 149°F.
As such, high-temperature vent pipe material (CPVC or polypropylene; see table below) must be used for the rst 3 feet (2" venting) or 0.5 feet (3" venting).
If such materials are unavailable, see the Venting section of the GF200 manual for instructions on how to limit the maximum water temperature set point.
* Approved polypropylene systems include: Duravent Polypro (Single Wall): 2PPS­xxx (2in), 3PPS-xxx (3 in) / Centrotherm Innoue SW: ISxx02xx (2 in), ISxx03xx (3 in) / Centrotherm InnoFlue Flex: IFVL02XXX (2 in). Refer to the manufacturer’s litera­ture for detailed information.
** For installation in Canada, eld-supplied plastic vent piping must comply with CAN/CGA B149.1 (latest edition) and be certied to the Standard. For Type BH Gas Venting Systems, ULC-S636. Components of this listed system must not be interchanged with other vent systems or unlisted pipes or ttings. All plastic components and specied primers and glues of the certied vent system must be from a single system manufacturer and must not be intermixed with another system manufacturer’s parts. The supplied vent connector and vent termination are certied as part of the water heater.
2
Locale Recommended Vent Materials
USA
Canada**
• PVC Schedule 40 (Solid core)
• CPVC Schedule 40 or 80 (Solid core)
• Approved Polypropylene*
• Type BH Special Gas Vent Class IIA (PVC)
• Type BH Special Gas Vent Class IIB (CPVC)
• Type BH Special Gas Class IIC (Polypropylene)
3
3
NOTE: The service clearances are recommendations.
If you are unable to maintain those specic clearances, be sure you have an alternative plan as to how you are going to service the unit.
Intake
Exhaust
Intake
Exhaust
12 in (300 mm) min.
12 in (300 mm) min.
Intake
Exhaust
Exhaust
Intake
15.5” x 20”
(310 sq. in.)
Vent
Venting requirements dier in the US and Canada. Consult the following chart or the most recent edition of ANSI Z223.1/NFPA 54 or CAN/CGA B149.1, as well as all applicable local codes and regulations when selecting vent pipe materials. Do not use cellular core PVC (ASTM F891), cellular core CPVC, or Radel® (polyphenolsulfone) for the exhaust vent.
90° = 5 linear feet
45° = 3 linear feet
90° = 8 linear feet
45° = 4 linear feet
Located on interior left side of cabinet (near buer tank).
Located on interior right side of cabinet (near heat exchanger).
See sub-step: 6Plumbing
If the GF200 is connected to Liqueed Propane Gas (LP), it MUST be converted using the LP Conversion Kit located inside the cabinet. Failure to do so could cause severe injury or death.
*WARNING:
3
4
6
Plumbing
A kit box containing the necessary plumbing connections is shipped inside the front cover.
Item Part Number Quantity
Open Brass Connection Adapter 85372 2
Plug Brass Connection Adapter 85523 2
Pipe Clips 85371 4
Flow Switch 85582 1
Vinyl Tubing (10.5") 83044 1
O-Rings 85369 6
Screws 82998 14
2" Vent Termination Caps
2" Wall Flanges
85590
85591
2
4
Jumper 85742 1
This appliance is shipped with cardboard inserts on the inside to support the plumbing during shipping. Remove cardboard prior to installation.
REMOVE CARDBOARD
Determine which side of the appliance the gas, inlet water, and outlet water connections will be made on. A) Left side connections B) Right side connections C) Both - One (or more) on each side
NOTE: Typically, both water connections are installed on the opposite side of the return air duct to allow for air lter & maintenance clearances.
ATTACH O-RING PN: 85369
NOTE: wet the
outer surface of the O-ring for easier insertion.
Install the plug adapters in the unused inlet and outlet connections.
1
2
3
Slide each plug through the hole in the cabinet and into the correspond­ing pipe; secure with (3) screws (PN: 82998) and (1) pipe clip (PN: 85371).
REMEMBER TO ATTACH O-RING BEFORE SECURING.
ATTACH PIPE CLIPS PN: 85371
4
COLD
SUPPLY
HOT
SUPPLY
UNION
FLOW SWITCH
TEMPERING VALVE
SHUT OFF VALVES
DRAINS
SERVICE DOOR
PRESSURE RELIEF VALVE
EXPANSION TANK
Typical near-appliance plumbing layout
Do not block service door
Dry-t the open brass connections (w/ O-rings removed, but w/ screws and clips in place) and solder nearby connections. Install the O-rings and re-insert the t­tings, fastening with clips and screws (x 3).
Take care not to damage the O-rings with excessive heat.
5
A tempering valve must be
installed on the hot water
outlet to prevent scalding.
Pressure
Relief Valve
Improper installation of the pressure relief valve may result in property damage, personal injury, or death. Follow all instructions and guidelines when installing the pressure relief valve. The valve should be in­stalled only by a licensed professional.
To complete the installation of the appliance, you must install an approved 3/4 in, maximum 150 PSI pressure relief valve (PRV) on the hot water outlet.
The water heater has a built-in high temperature shut o switch, so install a “pressure only” relief valve. This valve is not supplied, but is required.
The PRV should be placed as close to the hot water outlet as possible. No other valve should be placed between the PRV and the appliance.
Warning
6
7
Connection the condensate drain
Direct to
drain
Drain via
Neutralizer
Laundry tub
via condensate
pump
Direct to
laundry tub
Choose
Connection Side
This appliance is shipped from factory with a condensate drain pre-installed on the right side. To switch sides, refer to the GF200 Installation Manual.
To connect the condensate drain:
1. Connect a drain line to the 5/8 in barbed tting at the side of the appliance. Secure with hose clamp. Use only corrosion-resistant material for the drain line, such as PVC or CPVC. Do not reduce the size of this tting or the drain line to less than 1/2 in.
2. Place the free end of the drain line into an appropriate drain.
3. If you are using a condensate pump, ensure that the pump allows for up to 2 GPH of drainage. If you are not using a condensate pump, ensure that the drain line is pitched downward at a minimum slope of 1/4 in per foot.
Before connecting the con­densate drain, choose one of the following disposal options:
a. Direct to drain
b. Drain via neutralizer
c. Direct to laundry tub
d. Laundry tub via con-
densate pump
7
DO NOT install O-ring before soldering
9
Wiring
Service switch (Field Supplied)
120V /1P/60HZ 15A FUSED POWER SUPPLY
a
b
c
d
e
f
g
h
i
j
k
a
b
c
d
e
f
g
h
i
j
k
Error
Hot Water Recirculation
Diagnostics button
Information button
Reset button
Combustion
N/A
Display
Up button
Down button
Power button
A code will appear on the display
Indicates Recirculation Mode or Pump activity
For installers only
A code will appear on the display
Resets the water heater (when an error occurs)
Indicates when the gas burner is on
Increases the tem­perature
Decreases the tem­perature
Turns the water heater on or o
10
Front Panel
8
Gas Connection
Pipe size : 1/2 in to 3/4 in (inner diameter)
Gas Shuto Valve
Union
Gas Supply
Recommended Gas Pressure Settings:
NG: 3.5” – 10.5” w.c. LP*: 8.0” – 13.0” w.c.
To connect the gas supply:
1. Determine the gas type and pressure for the appliance by referring to the rating plate.
2. Perform a pressure test on the main gas supply line. For detailed instructions to meas­ure the inlet gas pressure, see relevant section in the water heater installation manual (supplied).
3. Determine the proper size and type for the gas line. Purge the gas line of any debris.
4. Install full port valves on the gas supply line and appliance.
5. Connect the gas supply line. Test it, all connection points, and the GF200 for gas leaks.
6. Shut o manual gas valve and run a hot water faucet (until the water heater shuts o due to lack of fuel) to purge the gas line.
7. Re-open the manual gas valve and open several high ow rate xtures to ramp the water heater up to its maximum ring rate.
8. Check the inlet gas pressure reading on the manometer as shown below.
9. If readings are out of range: adjust the inlet gas pressure regulator.
Recommendation: Install GF200 as rst appliance downstream of meter
Gas Supply Line
Gas meter’s capacity ≥ Total gas capacity of connected appliances
It is recommended that this appli­ance be connected as the rst one downstream of the gas meter to ensure a sucient gas supply.
Tighten the appliance connection valves with care to avoid damage.
It is recommended that a union be installed on the gas supply line close to the appliance, to facilitate any future maintenance or service.
Gas connection is possible from both sides. A union inside the cabinet will help improve access to plumbing and lters when routing gas line from right side.
NOTE:
Input Description
FLOW SWITCH
FLOW SWITCH: Connect the two leads from the external ow switch here (one per terminal). Note: The ‘hot’ lead only becomes energized (from the H2Air board) when Central Heating mode (W) is active. Switch closes at approx. 0.5 US gpm.
FLOW SWITCH
W HEAT: Connect heating wire from thermostat here.
G
VENTILATION: Connect continuous ventilation / circulation wire from thermostat here.
R 24 V AC OUTPUT: Connect power input wire from thermostat here.
C COMMON: Connect common wire from thermostat here.
YC
COMPRESSOR COMMON: Connect common wire from Outdoor A/C Unit control here. This is the GF200 FREEZE PROTECTION – it must be connected.
Y2
COOLING (2nd Stage): Connect second stage cooling wire from thermostat here (see Appendix 4.1 for cfm table).
Y1
COOLING (1st Stage): Connect rst stage cooling wire from thermostat here (see Appendix 4.1 for cfm table).
GROUND GROUND: Connect earth ground wire here.
L2 NEUTRAL: Connect the neutral wire for the power supply here
L1 LINE: Connect the line voltage wire for the power supply here
Cold Water
Remove the kit box before installation.
Do not use metal pipe
for draining condensate
Combustion Settings (%CO ± 0.5):
High re Low re
NG
8.9 9.5
LP*
10.2 10.8
Combustion Analyzer (optional):
Each NPE-240A is factory-tested before assembly into the GF200. However, should you wish to verify the combustion, target %CO values are listed below.
NOTE: Master power switch located behind the front cover on right-hand side of wiring panel it must be ON to operate NPE-240A.