NTI DL1 Specifications

Digilyzer DL1
Technical Specification
dated Oct 2003 Frame Consumer / Professional, up to 24 bit,
Sampling Frequency fs = 32 – 96 kHz, Also supports: Interleaved 96 kHz mode on
all inputs (single channel double sampling frequency mode)
Measurements
Signal Level-FS, Level-RMS, Signal Frequency,
THD+N (down to -100dB or 0.001%), Scope, Frequency Sweep, VU+PPM, Event Logger, Overload Detection
Carrier Sampling Frequency ( accuracy ±2.5 ppm),
Carrier Level, Error Indicator Box
Frame Channel Status according to AES 3
(edition 1999) and IEC 60958-3, Bit Statistics, Consistency Check
Event Logger
Recording Resolution selectable 1”, 10”, 1’, 10’, 1h Recording Duration 8’, 83’, 8h, 83h, 20days Display ?t 1”, 10”, 1’, 10’, 1h, 10h, 24h, all Recording Intervals max. 500
Single Errors in one recording interval 10 - 36 000
Input Connectors
AES3 (110 Ohm) XLR, S/PDIF (RCA), TOS-Link, ADAT, AES3id (75 Ohm) using optional adapter, phantom power resistant
Monitor Built-in speaker, headphone connector Display Backlit graphic LCD Power Supply - 3x AA size dry batteries (alkaline),
typical lifetime 8 hours
- External DC power, 7.5 VDC, 500 mA, stabilized, use NTI recommended parts only
Dimensions (L x W x H)
163 x 86 x 42 mm (6.4“ x 3.38“ x 1.63“)
Weight 300 g (10.5 oz) incl. batteries Temperature 0° to +45° C (32° to 113° F)
Contact details:
NTI AG Im alten Riet 102 9494 Schaan Liechtenstein Tel. +423 / 239 60 60 Fax. +423 / 239 60 89 info@nt-instruments.com, www.minstruments.com
Humidity < 90 % R.H., non condensing
Page 1 of 1