Features
• 16 Time Ranges in Single Timer (0.1 sec. to 120 min.)
• User Sets Time Ranges
No Math − Just Flip Switches
• Instructions Right on Unit
• Fine Tuning Knob for Precision Timing
• Pin for Pin Interchangeable with Timers
in the Field − No Rewiring
• AC or DC Operation
• CMOS Digital Circuitry − 0.5% Repeatable Accuracy
R61 Series
Programmable, DPDT, 10 Amp, AC or
DC, Delay On Release Time Delay
Relays.
TIME RANGE
D36
Alternate Knob Style
Switches
are recessed.
2.400 (60.96)
.242 (6.2)
.600 (15.24)
2.800
(71.12)
Knob
Style
Min Max
0.1 0.25
A
0.15 0.5
B
0.3 1.0
C
0.5 2.0
D
1.0 4.0
E
2.0 8.0
F
4.0 15
G
8.0 30
H
15 60
I
30 120
J
1.0 4.0
K
2.0 8.0
L
4.0 15
M
8.0 30
N
15 60
O
30 120
P
DPDT, 2 Form “C”
Ext. Switch
SecondsMinutes
OPERATION
DELAY ON RELEASE− Input voltage must be applied continuously
to operate the internal relay. When the control switch is closed, the
relay energizes. When the control switch is opened, timing begins.
When timing is complete, the relay will deenergize. Time may be reset
to zero during timing by closing the control switch.
CONTINUOUS ON
POWER
CONTROL ON
SWITCH
OUTPUT ON
SWITCHING
NTE Type No.
R61−11AD10−12 12VAC/DC DPDT 167mA 10A D36
R61−11AD10−24 24VAC/DC DPDT 83mA 10A D36
R61−11AD10−120 120VAC/DC DPDT 17mA 10A D36
SURFACE MOUNT 11−PIN OCTAL R95−104
PANEL MOUNT 11−PIN OCTAL R95−11 9
DIN RAIL MOUNT 11−PIN OCTAL R95−114
DIN RAIL MOUNT 11−PIN OCTAL R95−182
OFF
OFF
OFF
MOUNTING
STYLES
AC or DC OPERATED
Nom.
Voltage
Contact
Arr.
ACCESSORIES
DESCRIPTION
Input
Cur.
Nom.
DELAY
Contact
28VDC
or 120VAC
Max.
Cur. @
NTE
TYPE NO.
Diag
No.
6
1.770
(44.95)
4
3
2
(DC) + − (DC)
(AC) L N (AC)
7
8
9
10
1151
INPUT
Electrical Specifications
Contact
Rating: 10 Amps 240VAC or less, 1/3 HP, 240VAC or 120VAC
Pilot Duty 345VA, 120VAC or 240VAC, 50/60H
Life: 5000,000 operations at full load
Mechanical Life: 7,000,000 operations at no load
Input
Nominal Input voltage: See Chart
Steady state input current: See Chart
Timing
Timing adjustment modes available: See Timing Range Chart
Repeat Accuracy
± 0.5% − after established at steady temperature (4 hours)
Timing tolerance at high end of range: −0, +10%
Timing tolerance at low end of range: +0, −50%
Reset Time: 60 mS typ
Protection
Transient: surge test 10,000V for 20 mS
Dielectric Breakdown
Coil To Contact: 1850 VAC
Across Open Contact: 1850 VAC
Environmental Characteristics
Operating: −20°C to +55°C
Weight
Std: 4.5 oz (130 grams) approx.
Z
64
NTE Electronics, Inc. D Voice (973) 748−5089 D FAX (973) 748−6224 D http://www.nteinc.com