NTE Electronics R61 Series Catalog Page

Features
16 Time Ranges in Single Timer (0.1 sec. to 120 min.)
User Sets Time Ranges
No Math Just Flip Switches
Instructions Right on Unit
Fine Tuning Knob for Precision Timing
in the Field No Rewiring
AC or DC Operation
CMOS Digital Circuitry 0.5% Repeatable Accuracy
R61 Series
Programmable, DPDT, 10 Amp, AC or DC, Delay On Release Time Delay Relays.
TIME RANGE
D36
Alternate Knob Style
Switches are recessed.
2.400 (60.96)
.242 (6.2)
.600 (15.24)
2.800
(71.12)
Knob Style
Min Max
0.1 0.25
A
0.15 0.5
B
0.3 1.0
C
0.5 2.0
D
1.0 4.0
E
2.0 8.0
F
4.0 15
G
8.0 30
H
15 60
I
30 120
J
1.0 4.0
K
2.0 8.0
L
4.0 15
M
8.0 30
N
15 60
O
30 120
P
DPDT, 2 Form “C”
Ext. Switch
SecondsMinutes
OPERATION
DELAY ON RELEASEInput voltage must be applied continuously
to operate the internal relay. When the control switch is closed, the relay energizes. When the control switch is opened, timing begins. When timing is complete, the relay will deenergize. Time may be reset to zero during timing by closing the control switch.
CONTINUOUS ON POWER
CONTROL ON SWITCH
OUTPUT ON SWITCHING
NTE Type No.
R6111AD1012 12VAC/DC DPDT 167mA 10A D36
R6111AD1024 24VAC/DC DPDT 83mA 10A D36
R6111AD10120 120VAC/DC DPDT 17mA 10A D36
SURFACE MOUNT 11PIN OCTAL R95104
PANEL MOUNT 11PIN OCTAL R9511 9
DIN RAIL MOUNT 11PIN OCTAL R95114
DIN RAIL MOUNT 11PIN OCTAL R95182
OFF
OFF
OFF
MOUNTING
STYLES
AC or DC OPERATED
Nom.
Voltage
Contact
Arr.
ACCESSORIES
DESCRIPTION
Input
Cur.
Nom.
DELAY
Contact
28VDC
or 120VAC
Max.
Cur. @
NTE
TYPE NO.
Diag
No.
6
1.770
(44.95)
4
3
2
(DC) + (DC) (AC) L N (AC)
7
8
9
10
1151
INPUT
Electrical Specifications
Contact
Rating: 10 Amps 240VAC or less, 1/3 HP, 240VAC or 120VAC
Pilot Duty 345VA, 120VAC or 240VAC, 50/60H
Life: 5000,000 operations at full load Mechanical Life: 7,000,000 operations at no load
Input
Nominal Input voltage: See Chart Steady state input current: See Chart
Timing
Timing adjustment modes available: See Timing Range Chart
Repeat Accuracy
± 0.5% after established at steady temperature (4 hours)
Timing tolerance at high end of range: 0, +10% Timing tolerance at low end of range: +0, 50% Reset Time: 60 mS typ
Protection
Transient: surge test 10,000V for 20 mS Dielectric Breakdown
Coil To Contact: 1850 VAC Across Open Contact: 1850 VAC
Environmental Characteristics
Operating: 20°C to +55°C
Weight
Std: 4.5 oz (130 grams) approx.
Z
64
NTE Electronics, Inc. D Voice (973) 748−5089 D FAX (973) 748−6224 D http://www.nteinc.com
Loading...