Features
• Replaces Slow Blow Glass Cartridge Fuse
• .250” (6.35mm) Quick Connect Terminals
• Snap−In Mounting
• Visual Trip Indicator
• Push Button to Reset Breaker
R59 Series
Thermal Circuit Breaker, Fuse Holder
Type
D41
.540
(13.72)
Max
.625
(15.88)
Max
1.535 (38.99)
Max
.370 (9.4) .190 (4.83)
.325
(8.26)
Max
.760 (19.31)
Max
.760
(19.31)
Max
NTE Type No.
R59−0.25A 0.25 14.0
R59−0.5A 0.50 3.55
R59−1A 1.0 0.89
R59−2A 2.0 0.17
R59−3A 3.0 0.069
R59−4A 4.0 0.043
R59−5A 5.0 0.030
R59−6A 6.0 0.026
R59−7A 7.0 0.017
R59−8A 8.0 0.016
R59−10A 10.0 0.011
R59−12A 12.0 0.009
R59−15A 15.0 0.007
R59−20A 20.0 0.007
Current Rating
Amps
Typical Resistance
Ohms
Trip Times
0.25 to 2 Amp Types 3.0 to 20 Amp Types
Rated Load Trip Times Rated Load Trip Times
100% No Trip 100% No Trip
175% Trip in 1 Hour 135% Trip in 1 Hour
200% 4.5 to 28.0 Sec. 200% 2.2 to 15.0 Sec.
400% 1.0 to 6.5 Sec. 400% 0.55 to 1.8 Sec.
600% 0.4 to 4.0 Sec. 600% 0.27 to 0.7 Sec.
800% 0.17 to 0.45 Sec.
1000% 0.12 to 0.3 Sec.
.625 − .635
(15.88 − 16.13)
.570 − .575
(14.48 − 14.61)
.625 − .635
(15.88 − 16.13)
Recommended Panel Thickness: .032 − .062 (.813 − 1.574)
Recommended Panel Cutouts
.625 − .635
(15.88 − 16.13)
.540 − .550
(13.77 − 13.97)
Electrical Specifications
Electrical Characteristics (@ 25°C)
Calibration: Will continuously carry 100% of rating.
Maximum Operating Voltages: 32 VDC; 250 VAC, @ 50/60 Hz
Dielectric Strength: 1500VAC RMS
Resettable Overload Capacity:
Reset Time:
Interrupt Capacity: 1000 Amps @ 250 VAC, 50/60 Hz. and 32 VDC
Mechanical Characteristics
Termination: .250 (6.35) Quick Connect Terminals
Mounting: Snaps into panel from front
Weight: 0.35 ozs. (10 g) approx.
0.25 to 2 Amp types: May trip between 101% and 174%,
but must trip at 175% of rating within one hour at +25°C
3.0 to 20 Amp types: May trip between 101% and 134%,
but must trip at 135% of rating within one hour at +25°C
0.25 to 2 Amp types: Six times rated current
3.0 to 20 Amp types: Ten times rated current
0.25 to 2 Amp types: 180 seconds max.
3.0 to 20 Amp types: 10 to 60 seconds typ.
in accordance with UL standard 1077
NOTE: Soldering to terminals is not recommended.
(See Recommended Panel Cutouts)
62