NTE8065 thru NTE8242
Thermal Cutoff
(Thermal Fuse)
Description:
Twenty One Thermal Cut−offs (also known as Thermal Fuses) are now included in the NTE product line. They are miniature, NON−RESETTABLE temperature sensitive devices designed to prevent appliances and electronic equipment from
overheating. NTE thermal cutoffs are UL and CSA listed.
Literally thousands of different applications have been devised for thermal−cutoffs, thus providing a large replacement
market. Such applications include:
• Hair Dryers • Refrigerators • Battery Chargers
• Irons • Hot Plates • Glue Guns
• Electric Motors • Window Fans • Coffee Makers
• Microwave Ovens • Popcorn Poppers • Dishwashers
• Toasters • UPS • And hundreds of others
The TCO (Thermal Cut−Off) responds to temperature by interrupting an electrical circuit when the operating and/or environmental temperature exceeds the thermal rating of the device. This is accomplished when the internal organic pellet
experiences a phase change, allowing the spring activated contacts to permanently open the circuit.
Functioning
NTE
Type No.
8065 193 66 151 42 108 130 266
8070 193 72 162 50 122 115 239
8076 193 77 171 − − − −
8081 193 84 184 60 140 125 257
8085 193 87 189 − − − −
8090 193 93 200 − − − −
8096 193 98 209 76 169 140 284
8098 193 100 212 − − − −
8103 193 104 220 80 176 150 302
8108 193 109 228 88 190 140 284
8115 193 11 7 243 − − − −
Diag.
No.
Temperature
°C °F °C °F °C °F
Holding
Temperature
Maximum
Temperature
Functioning
NTE
Type No.
8118 193 121 250 94 201 170 338
8125 193 128 263 106 223 155 311
8139 193 141 286 11 7 243 171 340
8149 193 152 306 128 262 176 349
8167 193 170 338 146 295 300 572
8181 193 184 364 160 320 300 572
8182 193 192 378 162 324 290 554
8213 193 216 421 191 376 241 466
8226 193 228 443 − − − −
8242 193 240 464 200 392 290 554
Diag.
No.
Temperature
°C °F °C °F °C °F
Holding
Temperature
Maximum
Temperature
Electrical Rating
Volts
120/250 VAC 15A 10A
240 VAC 25A RES 16.7 RES
277 VAC 20A RES 15A RES
FEATURES:
• Maximum Current Rating: 15 Amps
• Typical Opening Temperature Tolerance: +0°C, −5°C
• 18 Gauge Solid Copper Wire
• Full 1 1/3 ” leads to fit all replacement configurations
• All types meet the requirements of Underwriters
Laboratories Specifications, CSA, and VDE.
• Each device comes packaged with 2 crimp splices for
solderless connection.
S UL File No. E49429
S UL File No. E117626 (Guide # XCMQ2)
S C−UL File No. E117626 (Guide # XCMQ8)
S CSA File No. LR43279
S VDE File No. 115369
Note 1: Temperature sensitive devices. Do not store above +48°C (+120°F).
Note 2: Color Band does not denote temperature group.
Note 3: The electrical resistance of the NTE series thermal cut−off is comparable to that found in an equal length of 18 gauge solid copper wire. With
proper air flow, heat generation below 15 Amps is minimal, above 15Amps the upper limit on the currentcapacity will depend on the environment
for each specific application.
Note 4: A general rule of thumb for continuous operating temperature for thermal cut−offs is 30°C less than the Maximum Opening Temperature.
Interrupting Continuous
Diagram 193
NOTE: Tin plated lead NOTE: Silver plated lead
Electrical Rating
Volts
120−277 VAC 125VA Pilot Duty
180 VAC 3A Motor Rating
3.220 (81.78) Max
1.380 (35.0)
Case End
.457 (11.6) Max
** Some devices may have a lead length of .980 (25.0)
Interrupting Continuous
1.383 (35.1) **
Epoxy End
.160 (4.1) Dia Max
Rev. 5−11