NTE NTE970 Datasheet

NTE970
Linear Integrated Circuit
3–Terminal Adjustable Positive Voltage Regulator
1.2V to 33V, 3A
Description:
The NTE970 is an adjustable 3–terminal positive voltage regulator in a TO3 type package capable of supplying in excess of 3 Amps over a 1.2V to 33V output range.
Features:
Absolute Maximum Ratings:
Input–Output Voltage Differential, VI–V Power Dissipation, P
D
Operating Junction Temperature Range, T Storage Temperature Range, T
stg
Thermal Resistance, Junction–to–Case, R
O
J
thJC
Lead Temperature (During Soldering, 10sec), T
Internally Limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0° to +125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65° to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L
35V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.5°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
+300°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Characteristics: (VI –VO = 5V, IO = 1.5A, P
= 30W, 0° ≤ TJ +125°C unless
max
otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Line Regulation Reg Load Regulation Reg
lineTA
load
= +25°C, 3V VI – VO 35V, Note 1 0.005 0.030 %/V VO 5V VO 5V
TA = +25°C, 0mA IO 3A, Note 1
5 25 mV – 0.1 0.5 %V
O
Note 1. Regulation is measured at constant junction temperature. Change in output voltage due to
heating effects must be taken into account separately. Pulse testing with low duty cycle is used.
Electrical Characteristics (Contd): (VI VO = 5V, IO = 1.5A, P
unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
= 30W, 0° ≤ TJ +125°C
max
Thermal Regulation Reg Adjustment Pin Current I Adjustment Pin Current Change ∆I Reference Voltage V
thermTA
Adj
Adj ref
= +25°C, Pulse = 20ms 0.002 %VO/W
50 100 µA 10mA IL 3A, 3V (VI – VO) 35V 0.2 5.0 µA 10mA IO 3A, 3V (VI – VO) 35V,
1.20 1.25 1.30 V
P 30W
Line Regulation Reg Load Regulation Reg
Temperature Stability T Minimum Load Current I Maximum Output Current Limit I
Lmin
max
3V (VI – VO) 35V, Note 1 0.02 0.07 %/V
line
load
VO 5V
10mA IO 3A, Note 1
20 70 mV VO 5V 0.3 1.5 %V 0° TJ +125°C 1 %V
S
VI – VO = 35V 3.5 10 mA VI – VO 10V 3.0 4.5 A
O O
VI – VO = 30V 1.0 A
RMS Noise, % of V
O
N TA = +25°C, 10Hz f 10kHz 0.003 %V
O
Ripple Rejection Ratio RR VO = 10V, f = 120Hz 65 dB
C
= 10µF 66 86 dB
Adj
Long Term Stability S TA = +125°C 0.3 1.0 %/1.0k
Note 1. Regulation is measured at constant junction temperature. Change in output voltage due to
heating effects must be taken into account separately. Pulse testing with low duty cycle is used.
.350 (8.89)
.215 (5.45)
.430
(10.92)
.135 (3.45) Max
V
IN
Adjust
.875 (22.2)
Dia Max
1.187 (30.16)
.665
(16.9)
V
OUT
Seating Plane
.040 (1.02).312 (7.93) Min
.156 (3.96) Dia (2 Holes)
.188 (4.8) R Max
.525 (13.35) R Max