NTE NTE959 Datasheet

NTE959
Linear Integrated Circuit
Voltage Regulator, Negative, –18V, 1A
Description:
The NTE959 voltage regulator employs current limiting, thermal shutdown, and safe–area com­pensation which makes it remarkably rugged under most operating conditions. With adequate heat– sinking they can deliver output currents in excess of 1.0 amperes.
Features:
Absolute Maximum Ratings:
Input Voltage, V
IN
Internal Power Dissipation, P
(TA = +25°C unless otherwise specified)
D
Derate Above +25°C 15.4mW/°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internal Power Dissipation (T
= +25°C), P
C
D
Derate Above +75°C 200mW/°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum Junction Temperature Range, T Storage Temperature Range, T
stg
J
Thermal Resistance, Junction–to–Ambient, R Thermal Resistance, Junction–to–Case, R
Electrical Characteristics:
Parameter Symbol Test Conditions Min Typ Max Unit
Output Voltage V
Line Regulation Reg
Load Regulation Reg
(VIN = –27V, IO = 500mA, TJ = 0° to +125°C unless otherwise specified)
O
LoadTJ
TJ = +25°C –17.3 –18.0 –18.7 V 5mA IO 1A, PO 15W,
–33V V TJ = +25°C,
Line
Note 1
Note 1
thJC
= +25°C,
thJA
–17.1 –18.0 –18.9 V
–21V
IN
–33V VIN –21V 25 360 –30V VIN –24V 10 180 5mA IO 1.5A 55 360 250mA IO 750mA 22 180
–35V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internally Limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Internally Limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–55° to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–65° to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
mV
mV
Electrical Characteristics: (VIN = –27V, IO = 500mA, TJ = 0° to +125°C unless otherwise specified)
Parameter Symbol Test Conditions Min Typ Max Unit
Quiescent Current I Quiescent Current Change ∆I
B
TJ = +25°C 4.5 8.0 mA –33V ≤ VIN –21V 1.0 mA
B
5mA IO 1A 0.5 Ripple Rejection RR 32V VIN 21V, f = 120Hz 57 dB Dropout Voltage VIN – VOTJ = +25°C, IO = 1A 2.0 V Output Noise Voltage V Output Resistance r Short–Circuit Current Limit I Peak Output Current I Average Temperature
TCV
O
sc
max
TA = +25°C, 10Hz f 100kHz 10 µV/V
n
f = 1kHz 19 m
TA = +25°C, VIN = 35V 0.2 A
TJ = +25°C 2.2 A
O
–1.1 mV/°C Coefficient of Output Voltage
Note 1. Load and line regulation are specified at constant junction temperature. Changes in V
due to heating effects must be taken into account spearately. Pulse testing with low duty cycle is used.
.420 (10.67)
Max
O
O
.147 (3.75)
Dia Max
.070 (1.78)
Max
.100 (2.54)
GND
.110 (2.79)
(12.7)
.250 (6.35)
Max
(12.7)
V
OUT
V
/Tab
IN
.500 Max
.500
Min
Loading...