Electrical Characteristics (Cont’d): (0°C ≤ TA ≤ 75°C and 4.75V ≤ VCC ≤ 5.25V unless otherwise
specified for ALL devices)
Parameter Symbol Test Conditions Min Typ Max Unit
Output Voltage – High Logic State V
OH
VCC = 4.75V, IOH = –5.2mA 2.4 – – V
Output Voltage – Low Logic State V
OL
IOL = 48mA – – 0.5 V
Output Current – High Impedance State I
OZ
VCC = 5.25V, VOH = 2.4V – – 40 µA
VCC = 5.25V, VOH = 0.5V – – –40 µA
Output Short–Circuit Current I
OS
VCC = 5.25V, VO = 0, Note 1 –40 –80 –115 mA
Power Supply Current
NTE6885, NTE6887
NTE6886, NTE6888
I
CC
VCC = 5.25V
–
–
655998
89
mA
Input Clamp Voltage V
IC
VCC = 4.75V, IIC = –12mA – – –1.5 V
Output VCC Clamp Voltage V
OC
VCC = 0, IOC = 12mA – – 1.5 V
Output GND Clamp Voltage V
OC
VCC = 0, IOC = –12mA – – –1.5 V
Input Voltage V
I
II = 1mA 5.5 – – V
Note 1. Only one output can be shorted at a time.
Switching Characteristics: (VCC = 5V, TA = +25°C unless otherwise specified)
NTE6885, NTE6887 NTE6886, NTE6888
Parameter Symbol Test Conditions Min Typ Max Min Typ Max Unit
Propagation Delay Time
t
PHL
CL = 50pF 3 – 12 4 – 11 ns
High to Low State
CL = 250pF – 16 – – 15 – ns
CL = 375pF – 20 – – 18 – ns
CL = 500pF – 23 – – 22 – ns
Propagation Delay Time
t
PLH
CL = 50pF 3 – 13 3 – 10 ns
Low to High State
CL = 250pF – 25 – – 22 – ns
CL = 375pF – 33 – – 28 – ns
CL = 500pF – 42 – – 35 – ns
Transition Time High to Low State
t
THL
CL = 250pF – 10 – – 10 – ns
CL = 375pF – 11 – – 13 – ns
CL = 500pF – 14 – – 15 – ns
Transition Time Low to High State
t
TLH
CL = 250pF – 32 – – 28 – ns
CL = 375pF – 42 – – 38 – ns
CL = 500pF – 60 – – 53 – ns
Propagation Delay Time
High State to Third State
t
PHZ(E)CL
= 5pF – – 10 – – 10 ns
Propagation Delay Time
Low State to Third State
t
PLZ(E)CL
= 5pF – – 12 – – 16 ns
Propagation Delay Time
Third State to High State
t
PZH(E)CL
= 50pF – – 25 – – 22 ns
Propagation Delay Time
Third State to Low State
t
PZL(E)CL
= 50pF – – 25 – – 24 ns