NTE NTE5646 Datasheet

NTE5646
TRIAC – Internally Triggered
Description:
The NTE5646 is a TRIAC that includes a diac trigger mounted inside the same package. This device saves the user the added expense of buying a discrete diac and the assembling associated with a gated triac. This device includes a dial trigger mounted inside the same isolated TO220 type package.
Absolute Maximum Ratings:
Repetitive Peak Off–State Voltage (Gate Open, TJ = +110°C, Note 1), V RMS On–State Current (TC = +80°C, Conduction Angle of 360°), I
T(RMS)
DRM
Peak Surge (Non–Repetitive) On–State Current (One Cycle, at 50Hz or 60Hz), I Peak Gate–Trigger Current (3sec Max), I Operating Junction Temperature Range, T Storage Temperature Range, T
stg
Typical Thermal Resistance, Junction to Case, R
GTM
opr
Θ
JC
Note 1. All values apply in either direction.
Electrical Characteristics: (TC = +25°C unless otherwise specified)
TSM
–40° to +110°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–40° to +150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
600V. . . . . . . . . . . . . .
10A. . . . . . . . . . . . . . . . . .
100A. . . . . . .
1.5A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.8°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parameter Symbol Test Conditions Min Typ Max Unit
Peak Off–State Current I
DRM
Maximum On–State Voltage V DC Holding Current I Critical Rate–of–Rise of
Off–State Voltage
Critical Rate–of–Rise of
Commutation Voltage
HOLD
Critical
dv/dt
Commutating
dv/dt
Gate–Controlled Turn–On Time T
TM
gt
Gate Open, TV = +110°C, V
= 600V, Note 1
DRM
0.5 mA
IT = 10A, Note 1 1.5 V Gate Open, Note 1 60 mA VD = 600V, Gate Open,
T
= +110C, Note 1
C
TC = +80°C, Gate Unenergized, V
= 600V, IT = 10A, Note 1
D
VD = 600V, tR = 0.1µs, I
= 10A (Peak)
T
60 V/µs
4 V/µs
3 µs
Trigger DIAC Specifications
Breakover Voltage Symmetry ∆V Breakover Voltage
V
(BO) BO
3 V
30 45 V
(Forward & Reverse)
Dynamic Breakback Voltage
[V ±] 5 V
(Forward & Reverse)
Peak Breakover Current I
BO
200 µA
Trigger Firing Capacitance C 0.1 µF
Note 1. All values apply in either direction.
.147 (3.75)
Dia Max
.070 (1.78) Max
.420 (10.67)
Max
.110 (2.79)
Isolated
.500
(12.7)
Max
.250 (6.35)
Max
.500
(12.7)
Min
MT
1
.100 (2.54)
Gate
MT
2
Loading...