NTE NTE1870 Datasheet

NTE1870
Integrated Circuit
Module – Color TV Switching Regulator
Absolute Maximum Ratings: (TA = +25°C unless otherwise specified)
Input AC Voltage, V Output Power, P
AC: 90V to 280V 80W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC: 150V to 280V 100W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Substrate Temperature, T Junction Temperature, T Ambient Operating Temperature Range, T Storage Temperature Range, T Thermal Resistance, Junction–to–Case, R
AC
max
O
max +105°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C
J
opr
stg
thJC
+105°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–10° to +60°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–30° to +105°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.8°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Characteristics:
Parameter Test Conditions Min Typ Max Unit
Output Voltage
Hi +B
Low +B VAC = 220V, IO1 = 500mA, IO2 = 500mA 15.0 V Line Regulation VAC = 90V to 280V, IO1 = 500mA, IO2 = 500mA 1 V Load Regulation VAC = 220V, IO1 = 300mA to 700mA, IO2 = 500mA 1.5 2.0 V Ripple Voltage VAC = 220V, IO1 = 500mA, IO2 = 500mA 0.3 0.6 V Temperature Stability VAC = 220V, IO1 = 500mA, IO2 = 500mA 0.01 %/°C Operating Frequency VAC = 220V, IO1 = 500mA, IO2 = 500mA 34 kHz Operating Efficiency VAC = 220V, IO1 = 500mA, IO2 = 500mA 80 % Cross Road Regulation VAC = 220V, IO1 = 500mA, IO2 = 0 to 1A 0.2 V Dielectric Voltage
(TA = +25°C unless otherwise specified)
VAC = 220V, IO1 = 500mA, IO2 = 500mA 114.0 115.0 116.0 V
Prim – Second
4 kV
Note 1. Hi +B: VO1, IO1; Low +B: VO2, IO2
P–P
Pin Connection Diagram
(Front View)
TR5 Collector (Internal)
15
TR5 Collector (Internal)
14 13
No Pin No Pin
12 11 TR5 Emitter (Internal)
TR5 Base (Internal)
10
Constant Current base Drive
9
Voltage Compensation
8 7
Constant Current Base Driver Control Constant Current Base Driver Control
6
Current Feedback for Overcurrent Protection
5
Power Supply for Control Voltage Set Up4 Voltage to Set Up an Output Voltage
3
Soft Start/Output Voltage Setting
2
Control Circuit GND
1
2.330 (59.2)
2.050 (52.0)
.335 (8.5)
1.004 (25.5)
.630
(16.0)
.835
(21.2)
115
.100 (2.54)
.205 (5.2)
1.400 (35.6)