NTE NTE109 Datasheet

NTE109
Germanium Diode
Fast Switching General Purpose
Description:
The NTE109 is a high conductance device with good switching characteristics for low impedance cir­cuits, high resistance–high conductance for efficient coupling, clamping and matrix service, and for­ward and inverse pulse recovery for critical pulse applications.
Absolute Maximum Ratings: (TA = +25°C unles otherwise specified) Continuous Inverse Operating Voltage (Note 1), V
cont
Continuous Average Forward Current, IF 60mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak Recurrent Forward Current (Note 2) 325mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Forward Surge Current (1 sec), I
500mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FSM
Electrical Characteristics:
Peak Reverse Voltage, P Forward Voltage Drop (IF = 200mA), V Maximum Reverse Leakage (VR = 50V), I
RV
F
R
Additional Specifications:
Ambient Temperature Range, TA –78° to +90°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Absolute Maximum Storage Temperature Range, T
stg
–78° to +100°C. . . . . . . . . . . . . . . . . . . . . . . . .
Average Power Dissipation (TA = +25°C), PD 80mW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Derate Above 25°C 10mW/10°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Average Shunt Capacitance 0.5µfd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Average 100mc Rect. Efficient 55%. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
80V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.0V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100µA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Note 1 The continuous inverse operating voltage rating, V
operated at elevated junction temperature. The percent derating of V perature increment above 25°C is equal to V
/10. For critical high temperature–high volt-
cont
must be reduced when the diode is
cont
for each 10°C tem-
cont
age applications, is recommended that diodes be 100% tested and specified at the elevated temperature.
Note 2 The peak operating current is generally the controlling factor in AC rectifier service and may
be exceeded for pulses of less than 200µs duration.
1.000 (25.4)
Min
Color Band Denotes Cathode
.300
(7.63)
Typ
.107 (2.72) Dia Max.022 (.509) Dia Max