NTE 15050AC, 15049AC, 15048-ECG, 15047-ECG, 15046-ECG Datasheet

...
NTE15040–ECG thru NTE15048–ECG
NTE15049AC & NTE15050AC
Surge Arresters (Gas Filled)
DC Breakdown Voltage
Impulse Breakdown Maximum Capacitance
NTE Type No.
Diag.
No.
(VDC)
Minimum
Volts
Maximum
Volts
Impulse Breakdown
@ (100V/ms)
Maximum Voltage
Maximum Capacitance
Between Electronics
@ 1MHz (pF)
15040–ECG 628 75 60 90 400 1.0 15041–ECG 628 90 72 108 400 1.0 15042–EGC 628 110 88 132 450 1.0 15043–ECG 628 145 116 174 500 1.0 15044–ECG 628 230 195 265 600 1.0 15045–ECG 628 300 255 345 700 1.0 15046–ECG 628 350 297 403 750 1.0 15047–ECG 628 470 400 540 850 1.0 15048–ECG 628 600 510 690 1000 1.0
15049AC 628 120VAC 225 700 1.0 15050AC 628 240VAC 425 800 1.0
SPECIFICATIONS
Surge Life
10A 10/1000µs Pulse 2500 Operations. . . . . . . . . . . . . . . . . . . .
500A 10/1000µs Pulse 1000 Operations. . . . . . . . . . . . . . . . . . .
AC Suffix 300 Operartions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Current
8/20 20kA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Current
10 Operations 60Hz for 1sec., with 3 min. Intervals 20. . . . . .
AC Suffix 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Current
11 Cycles 60Hz 20A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Suffix 10A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Insulation Resistance
100 VDC 10,000 Megohms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Temperature –65° to +125°C. . . . . . . . . . . . . . . . . . . . . . . .
Response Time (Typical) < 100ns. . . . . . . . . . . . . . . . . . . . . . . . . . . .
TYPICAL CIRCUIT APPLICATIONS
Application Protected Equipment NTE Type
CATV Trunk Amplifier 15043–ECG
Cable Extender, Splitter Grounding Block, Converter Box, 30 & 60 VAC Power Supply
15044–ECG
AC Line Protection
117 VAC Line 15049AC 220 VAC Line, All AC Loads 15050AC
Communica­tion
Modem 15046–ECG Antenna Connected Equipment 15041–ECG,
15043–ECG, 15044–ECG
Power Sup­plies
Voltage Doubler, Capacitors, Voltage Regulator, Rectifier Diodes
15044–ECG, 15047–ECG
Computer Data Lines 15041–ECG,
15044–ECG
Application Protected Equipment NTE Type
Test Equipment Meter Inputs 15040–ECG,
15045–ECG
Capacitive Discharge
Ignition Circuit Components, Pulse Generator Components
15044–ECG, 15046–ECG
Process Control (24 MA Signal Loop)
Instrumentation Circuits 15040–ECG,
15041–ECG
Signal Lines (Single Ended)
Alarm Circuits 15040–ECG
Communications (Lightning)
Telephone Line (Normal Mode)
15046–ECG
Power Line (Lightning)
AC Wall Output (Long Branch Circuit) 120 VAC
15049AC
Breaker Box (Short Branch Circuit) 240 VAC
15050AC
.245 (6.22)
.319 (8.1) Dia
.032 (0.813) Dia
1.490 (37.7)
Diagram 628