NSS PREDATOR CXH100 Operating Instructions Manual

PREDATOR CXH100
https://harrissupplyind.com - To Order Parts Call 608-268-8080
IMPORTANT SAFETY INSTRUCTIONS
READ AND UNDERSTAND ALL INSTRUCTIONS
BEFORE OPERATING OR SERVICING MACHINE
Failure to Observe These Instructions Can Cause Personal Injury
DANGER!
ALWAYS unplug machine before attempting to service the motorized brush attachment.
NEVER operate in standing water. NEVER expose to rain. ALWAYS store indoors.
NEVER overfill recovery tank or allow water to enter vacuum standpipe. This will cause damage to the vacuum motor and possible electrocution.
NEVER operate machine with a cut, abraded or taped cord.
NEVER operate machine with a broken grounding blade on the plug.
ALWAYS replace the entire cord when the cord or plug is damaged in any manner.
NEVER handle the machine, cord or plug with wet hands.
NEVER drop or insert any object into any machine opening.
ALWAYS keep face, fingers, hair or any other body part, or loose clothing away from any machine opening or any moving part, particularly the revolving brush.
NEVER leave the machine unattended when plugged in. Unplug the machine from the electrical outlet when not in use.
ALWAYS turn the machine off before unplugging it from the electrical outlet.
NEVER operate this machine in the presence of flammable or combustible liquids or fumes.
• When any electrical motor, switch, cord or plug service is required, maintenance should only be done by an authorized service station, an electrician or other qualified persons.
NEVER operate this machine if it is not working properly, if it as been dropped, damaged, exposed to weather, or dropped into water. Return the machine to a ser vice center for examination and repair.
NEVER operate this machine with any air opening blocked. Keep all air openings free of dust, lint, hair, ect.
NEVER operate this machine without solution tank filter screens or vacuum standpipe filter screen in place or if they are clogged. Clean all filter screens after every use.
ALWAYS store this machine indoors. Protect it from rain or snow.
NEVER spray the top of the machine with liquids.
DO NOT pull or carry this machine by the electrical supply cord, use the cord as a handle, close a door on the cord, pull the cord around sharp edges or corners, or expose to heated surfaces.
NEVER disconnect the plug by pulling on the cord. To disconnect the cord from the outlet grasp the plug, not the cord.
ALWAYS unplug this machine before attempting to service.
ALWAYS use a defoamer which will prevent a buildup of foam in the recovery tank. If a defoamer is not used, the motor can be damaged from shampoo being pulled into the vacuum motor.
to Machine Operator, By-standers or Possible Machine Damage.
SAVE THESE INSTRUCTIONS
INFORMATION & OPERATING INSTRUCTIONS
https://harrissupplyind.com - To Order Parts Call 608-268-8080
DO NOT OPERATE MACHINE UNTIL YOU HAVE READ THIS SECTION
IMPROPER USE OF THE PREDATOR CXH100 WILL VOID THE WARRANTY
1. Always use a rag to prevent burns when handling quick-disconnects.
2.
Always use a defoamer when foaming occurs to prevent vacuum motor damage.
3. To keep fitting and lines from damage during freezing conditions, use an antifreeze in the pump and heater or keep equipment inside heated areas.
4. Do not let pump run dry.
5. Use neutral pH, water-based products only - NO SOLVENTS!
INSPECTION:
Carefully unpack and inspect the PREDATOR CXH100 for shipping damage. Each unit is tested and inspected before shipment. Any damage incurred is the responsibility of the carr ier, who should be notified immediately.
CLEANING SOLUTIONS:
We recommend liquid cleaning chemicals. Powders may be used, but unless mixed very thoroughly, they could cause build-up in the lines, pump, quick-disconnects, etc. A pH of 7-9 is strongly recommended to avoid premature pump wear, which would void the warranty.
MAINTENANCE:
For optimum performance, flush the machine with clear water at the end of each working day. Once a month, minimum, run a flushing compound through the machine to cut any alkaline build-up that may have formed.
Lubricate wheels, casters and hinges as needed. The pump and vacuum motors do not require any maintenance.
The body can be cleaned with a general all-purpose detergent and protected with a silicone type product like Armor All®. The quick-disconnects should be lubricated with silicone, also.
Prior to each job, inspect the holding tank filter and the recovery tank float filter for hair and dirt. The drain valve should also be inspected regularly and kept free of any debris or build-up.
SET-UP:
https://harrissupplyind.com - To Order Parts Call 608-268-8080
Fill the holding tank with clear water and the detergent of your choice. Mix well. Although this machine is designed to supply instant hot water, the addition of warm or hot water to the holding tank would be a plus factor.
1. Plug in cord #1, identified by the 4" long red band on the end of the cord. (This cord runs the pump and vacuums).
2. Turn on the pump and spray through the cleaning tool for a few seconds to fill the lines with solution.
3. Plug in cord #2. IF THE GREEN LIGHT ILLUMINATES, THE HEAT EXCHANGER WILL TURN ON AUTOMATICALLY (SEE NOTE BELOW). Wait 2 minutes for the heat exchanger to reach operating temperature. You may now begin cleaning. It will take about 10 seconds for the initial heat to reach the wand.
NOTE: 240 Volt machines do not have a green light. NOTE: If the green circuit indicator light does not illuminate when cord #2 is plugged in,
then both cords are on the same circuit. Try other outlets until the light comes on. See bypass switch section (below) if you are unable to get a green light.
BYPASS SWITCH:
NOTE: 240 Volt machines do not have a Bypass Switch. The bypass switch completely bypasses the circuit locator. Use this feature when you cannot
get the green light to come on and you believe that the two cords are on separate circuits.
CAUTION: If the bypass switch is on and the two cords are plugged into the same circuit, the breaker will blow.
ELECTRIC CIRCUIT LOCATOR:
NOTE: 240 Volt machines do not have an Electronic Circuit Locator. This unique, patented “smart system”, operated by a solid state circuit, will inform the operator
when the two cords are plugged into separate lines by illuminating the green indicator light. This helps prevent tripping circuit breakers.
BALL FLOAT VAC SHUTOFF:
When the recovery tank is full, the float system will shut off the incoming air flow and prevent water from entering the vacuum motors. The float may not work properly if the float filter is clogged or if there is heavy foam in the tank.
CAUTION: To avoid vac motor damage, a travels freely before turning on the machine. U
SAFETY PRECAUTIONS:
All extension cords must have a rating of at least 12/3 (#12 cord). Extension cords should be no longer than 50 feet. Replace the plug immediately if the ground prong becomes damaged or is broken off. Not only is the ground necessary for safety, but the circuit locator system will not operate correctly without it.
lways make sure the float filter is clean and the ball
se a defoamer whenever foam is present.
(5)
https://harrissupplyind.com - To Order Parts Call 608-268-8080
21
(3) (4)
VACUUM (1), VACUUM (2), AND PUMP (3) SWITCHES:
These switches are all powered by cord #1 (4" red band). Switches are on when illuminated.
BYPASS SWITCH (4): Not part of 240V machine
Turning on this switch (switch illuminates when on) bypasses the circuit locator. See previous page for explanation of the bypass system.
GREEN INDICATOR LIGHT (5): Not part of 240V machine
When this light is illuminated, it confirms that the machine is on two separate circuits. See previous page for additional information on the circuit locator.
SWITCH PLATE
HOLDING TANK LID
DOME (RECOVERY TANK)
8" WHEELS
VENT
3" CASTORS
VAC INTAKE
LATCH (2)
DRAIN VALVE
LIFT HANDLE
QUICK-DISCONNECT
(SOLUTION LINE ATTACHMENT)
COMMON STAINS AND CLEANING TREATMENTS
https://harrissupplyind.com - To Order Parts Call 608-268-8080
TREATMENT METHODS
First: Remove excess material by blotting to absorb liquids, or by scraping with a dull edge
(butter knife) is a solid.
Second: Clean the remaining stain as directed by the chart below. Always follow the direction
on the container. Apply the cleaning material directly to the stain (avoid over wetting the carpet or upholstery), then remove the loosened stain material with a white ab-
sorbent cloth or tissue. Third: When the carpet is dry, gently brush the carpet pile to restore its appearance. Note: Treat unknown stains with a volatile solvent first and follow with other agents as re-
quired. If you are uncertain of the effect of the cleaning agent on the carpet fiber or
dye, test on an inconspicuous area first.
STAIN TYPE TREATMENT MATERIAL
Asphalt Volatile solvent/detergent Beer Liquid detergent, White vinegar Berry stain Liquid detergent, Ammonia 3-6%, Water Bleach Liquid detergent, Water Blood (dried) Warm detergent, Ammonia 3-6%, Water Blood (wet) Liquid detergent, Water Butter Volatile solvent Catsup or Mustard Liquid detergent Chewing gum Volatile solvent Chocolate Liquid detergent, Ammonia water Coffee Detergent, White vinegar, Volatile solvent Cola drink Liquid detergent Creme de Menthe (green) Liquid detergent Egg (raw) Liquid detergent Food dye Liquid detergent, Water Furniture dye or polish Paint/Oil/Grease remover, Detergent Gravy Liquid detergent Lipstick Paint/Oil/Grease remover Mascara Paint remover, Volatile solvent, Detergent, Water Milk Liquid detergent Orange drink Liquid detergent, Water Shoe polish Heated iron into clean towel, Volatile solvent Tea Liquid detergent Tomato Juice Liquid detergent Urine Liquid detergent, Water Vomit Warm detergent, Water, White vinegar Wine Liquid detergent, Ammonia 3-6%, Water, Vinegar
PREDATOR CXH100
https://harrissupplyind.com - To Order Parts Call 608-268-8080
PARTS LIST
ITEM # PART # DESCRIPTION ITEM # PART # DESCRIPTION
#1 4091011 Metal "T" Handle
#1A 4091231 Drain Gate
#2 4090581 Screw, 10-32 X 5/8, S/S #3 4091251 Latch
#4 4091161 O-Ring, Thin #4A 4091171 O-Ring, Thick #4B 4090701 Nut, Cast Aluminum
#5 4091661 Vacuum Tank, Black, specify model
#6 4091241 Hose Barb, 1-1/2", plastic
#7 4091291 PVC Elbow, 1-1/2"
#8 4091391 Gasket, for Vacuum Dome
#9 4091581 Vacuum Dome #10 4091571 Vac Shut-off, manifold Assy.
#10A 4091501 Ball & Cage
#11 4090701 Nut, Cast Aluminum #12 4091171 O-Ring, Thick #13 4091291 PVC Elbow, 1-1/2" #14 4091121 Hose Clamp, size 28 #15 4091551 Hose, Rubber, 2" X 20"
#15A 4091561 Hose, Rubber, 2" X 16"
#16 4091591
4091741
#16A 4091201 Hose Barb, 1/3 pt X 3/8 hose
#17 4091061 Hose Clamp, size 36 #18 4091221 Heat Exchanger Mount #19 4091421 Hose, 1/4" X 26" #20 4091081 Elbow, Brass, Street, 1/4 pt #21 4091091 Elbow, Brass, Street, 1/8 pt #22 4091611 Gasket #23 4091631 Stop Chain, 13" #24 4091181 Split Ring #25 9120930 3/16 Flat Washer, ZP #26 9120900 1/4-20 Hex Nut, w/Ny-Lok, ZP #27 4091211 Vacuum Motor, 2-stage, 120V
4092101 Vacuum Motor, 2-stage, 240V
#27A 4091431 Gasket, Vac Motor
#28 9120920 1/4 Hex Nut, Finish #29 9120880 1/4 Split Lock Washer #30 9091080 1/4-20 X 3-1/2 Hex Bolt #31 4091651 Manifold, Vacuum, #3 or #4
#31A 4091651 Manifold, Vacuum, #3 or #4
#32 4091411 Exhaust Flange #33 9121270 1/4-20 X 1" Bolt, Hex Head, ZP #34 9120900 1/4 Hex Nut, w/Ny-Lok, ZP #35 N/A #36 4091281 Heat Sink Plate #37 4091401 Handle, Chrome #38 4090601 1/4-20 X 3/8" Screw, Flathead, ZP #39 4091031 Quick Disconnect, male, 1/4 p.t. #40 4090691 Washer, Vulcanized Fiber
#40A 4091111 Bushing, Vulcanized Fiber #40B 9122470 Washer, Brass, 1"OD X 9/16IDX 1/16"
#41 4091311 Louver, 3" (includes 3 screws) #42 4091261 Latch Strike
Heat Exchanger, Complete, CXH100, 120V Heat Exchanger, Complete, CXH100, 240V
Thermistor Control w/potentiometer (see misc.)
#43 4090061 Label, CXH100, NSS #44 4091331 PVC Reducer #45 4091151 Cord Retainer w/Strain Relief #46 4091301 #47 4091321 Snap Track (N/A on 240V) #48 4091271 Axle, 1/2 X 18-13/16" #49 4091361 Wheel, 8 inch, non-marking #50 4091021 Axle Cap #51 9120900 1/4 Hex Nut, Ny-Lok, ZP #52 4091141 Axle Bracket #53 4090611 1/4-20 X 3/4" Hex Bolt, ZP #54 4091511 Base, Black (specify model) #55 4091351 Castor, 3" swivel #56 4091641 Holding Tank, Black (specify model) #57 4091191 Filter, Pump Inlet, 40 mesh, S/S #58 4091601 Lid, with Hinges #59 4090101 Switch Plate, (empty) CXH100
#59A 4090511 #4 X 3/8" Screw, Panhead, S/S
#60 4091041 Switch, SPST, Covered, w/light #61 4091041 Switch, SPST, Covered, w/light #62 4091041 Switch, SPST, Covered, w/light #63 4091051 #64 4091071 Light, Green (N/A on 240V) #65 4091381 Pump, 100 PSI, 120V
4092121 Pump, 100 PSI, 240V #66 4091131 Hose Clamp, 3/8 - 7/8 #67 4091101 Hose Barb & Elbow, plastic #68 4091531 Hose, Rubber, 3/8" X 13" #69 4091541 Hose, Rubber, 3/8" X 48" #70 4090531 6-32 Hex Nut w/Ny-Lok #71 4091441 Fan, Cooling, 100CFM, 120V
4092131 Fan, Cooling, 100CFM, 240V #72 4091451 Fan Guard #73 4090541 6-32 X 2" Screw, Panhead, S/S #74 4091521 Cord Wrap, Black #75 1391161 Washer, Plastic, 5/8OD X 3/8ID X 1/16 #76 4090671 3/8 Acorn Nut, Nickel Plate
MISCELLANEOUS ASSEMBLIES/PARTS
4091621 Drain Gate Assembly, complete with
4091461* Thermistor Control Kit w/Potentiometer
4091471* Thermistor Control Kit w/Potentiometer,
4091481* Rebuild Kit for 100 PSI pump
(NOTE: Items in kits not sold separately.)
4090251 Power Cord, 120V 4090261 Power Cord, 240V
Dual Cord Sensor Circuit Board (N/A on 240V)
Switch, SPDT, Covered, w/light (N/A on 240V)
O-Rings & Nut
& Probe (240V, #4091721)
Probe & Cutout (240V, #4091731)
NOT SHOWN
PREDATOR CXH100
https://harrissupplyind.com - To Order Parts Call 608-268-8080
13
12
4B
11
19
20
14
15
7
38
10
10A
9
8
5
4B
6
4A
4
1
2
1A
3
27
27A
17
16
21
15A
28
31
32
37
16A
18
14
26 25
24 23
14
29
30
22
14
42
41
27
27A
31A
40
67
68
41
40B
53
69
66
65
67
66
26 25
28 29
30
34
70
44
54
41
59A
33
35
36
73
71
53
52
51
60
61
62
63
64
59
56
72
46
45
47
48
49
50
58
57
76
75
74
40
39
40A
55
34
43
PREDATOR CXH100
FAN
https://harrissupplyind.com - To Order Parts Call 608-268-8080
BLACK WHITE
ORANGE
ORANGE
#2
OUTSIDE
WHITE
BLUE
VACUUM
VAC 1
SW
VAC 2
SW
BLACK
SW
#1
INSIDE
PUMP
VACUUM
CORD 1
GROUND
WHITE
PREDATOR
CXH100
WIRING DIAGRAM
DUAL
BLACK
RED
TEMP. CONTROL
WHITE
WHITE
BLACK
TC
P4 P3
HEATER
CIRCUIT
BOARD
P2
WHITE
P7P6P5
P1
GREEN
LIGHT
BLACK
GROUND
CORD SENSOR
BYPASS SWITCH
BLACK
WHITE
CORD 2
6/12/01
PREDATOR
CXH100
WIRING DIAGRAM
240V
FAN
120V
VAC 1
SW
VAC 2
SW
BROWN
ORANGE
SW
BROWN BLUE
ORANGE
WHITE
BLUE
VACUUM
FILTER
BROWN
CORD 1
GROUND
WHITE
VACUUM
BLUE
PUMP
NSS Enterprises, Inc.
3115 Frenchmens Road, Toledo, Ohio 43607 PHONE (419) 531-3761 FAX (419) 531-3761
NSS® Enterprises, Inc. European Distribution Centre
Unit II, Pinfold Trading Estate 55 Nottingham Road STAPLEFORD, NOTTINGHAM NG9 8AD ENGLAND U.K. PHONE: (44) 0115 939 1568 FAX: (44) 0115 949 0615
PREDATOR CXH100 ORIG. 05-00 9094004 WHW REV. B 08-01
TEMP. CONTROL
WHITE
WHITE
BLACK
TC
HEATER
GROUND
CORD 2
11/26/97
Loading...