NSi Industries P1104FM-M User Manual

®
TIME SWITCH MECHANISM FOR POOL PANELS
240 VOLT, 24-HOUR MECHANICAL TIME SWITCH MECHANISM
MODEL#: P1104FM-M
CONTACT CONFIGURATION:
TIME SWITCH RATING:
w/ Fireman Switch (Heater Cutoff Switch)
DPST (Double Pole Single Throw), (2) NO (Normally Open Contacts), (1) NC (Normally Closed Contact)
40A Resistive/Inductive per pole, 7.5HP @ 240V (NO Contacts); 15A General Purpose/Resistive
E312471
MODES OF OPERATION: FIREMAN SWITCH RATING:
AUTOMATIC OPERATION:
3 Operating modes available: Timer/AUTO, OFF/Standby, ON
15A, SPST @ 12OV
Time Switch can be switched on or off in 15 minute increments for a multitude of on/ off operations per 24 hour period. See below for details on “modes of operation”.
IMPORTANT SAFETY INSTRUCTIONS
ATTENTION: Read carefully before attempting to install this control. Failure to comply with instructions could result in personal injury and/or property damage!
This control must be installed in accordance with National and Local Electrical Codes.
1. Disconnect power at main panel before installing or servicing this device.
2. USE COPPER CONDUCTORS ONLY
3. Do not exceed the ratings of this device, and current capacity of conductors
4. This control should not operate any equipment which would cause bodily injury or property damage should it be activate
5. unexpectedly.
READ & FOLLOW ALL INSTRUCTIONS – SAVE THESE INSTRUCTIONS
INSTALLATION & WIRING INSTRUCTIONS
To install Time Switch into control panel, insert lower back
1. edge of mechanism into Universal mounting plate located in control panel. Push top front edge of mechanism down into the mounting plate. You will here a click indicating that the Time Switch is securely attached to universal mounting plate. To wire switch follow the wiring diagram provided.
2. Use solid or stranded COPPER wire only.
3. Strip the supply and load wires by removing 1/2 inch of
4. insulation. Insert the wires under the proper terminal plates and
5. tighten the screws firmly.
PROGRAMMING & OPERATING YOUR TIME SWITCH MECHANISM
SETTING THE TIME: Rotate clock face in a clockwise direction until proper time is displayed. In order to properly set time
for AM or PM, verify that black arrow on clock face matches the correct 24-hour clock setting (example: 6=6AM, 18=6PM). If it does not, rotate clockwise 1 complete turn for correct AM or PM setting.
SETTING “ON” and “OFF” TIMES: Set the captive trippers for
desired on/off sequence required.
OFF-Push trippers IN (toward center of clock)
• ON-Push trippers OUT (away from center of clock)
MODES OF OPERATION: (Using 3-Position Rocker Switch)
Timer/AUTO: Automatic Time Switch operation according
• to captive tripper’s on/off settings OFF/Standby: Maintains proper clock time and Time Switch
• program settings during periods of non-use. ON: Used to override Timer/AUTO mode. User can turn the
• Time Switch ON. Time Switch will remain ON until the user switches back to TIMER/AUTO or OFF mode.
TORK, INC. • 888.500.4598 • www.TORK.com
NOTE: There is no adjustment to fireman switch
A DIVISION OF
MODES
TIMER/AUTO OFF/STANDBY ON
NSi INDUSTRIES, LLC
Loading...