TIME SWITCH MECHANISM FOR POOL PANELS
TWO (2) CLOCK MODULE, 240 VOLT, 24-HOUR
MODEL#: P1104-2M
MECHANICAL TIME SWITCH MECHANISM
E312471
CONTACT CONFIGURATION:
SWITCH RATING (each):
MODES OF OPERATION:
AUTOMATIC OPERATION:
DPST (Double Pole Single Throw), (2) NO (Normally Open Contacts)
40A Resistive/Inductive per pole, 5HP @ 240V (NO Contacts)
3 Operating modes available: Timer/AUTO, OFF/Standby, ON
Time Switch can be switched on or off in 15 minute increments for a multitude of
on/off operations per 24 hour period.
IMPORTANT SAFETY INSTRUCTIONS READ & FOLLOW ALL INSTRUCTIONS – SAVE THESE INSTRUCTIONS
ATTENTION: Read carefully before attempting to install this control. Failure to comply with instructions could result in personal injury and/or property damage!
This control must be installed in accordance with National and Local Electrical Codes.
1.
Disconnect power at main panel before installing or servicing this device.
2.
USE COPPER CONDUCTORS ONLY
3.
Do not exceed the ratings of this device, and current capacity of conductors
4.
This control should not operate any equipment which would cause bodily injury or property damage should it be activate
5.
unexpectedly.
INSTALLATION & WIRING INSTRUCTIONS
To Remove & Replace 2-Clock Assembly from Panel:
1.
a) Remove pullout handle. b) Remove screws in pullout
switch base. c) Lift out entire time switch assembly from
panel.
To Re-Install: a) Remove pullout handle from NEW 2-clock
2.
assembly. b) Insert top edge of assembly into support
brackets on top side of panel. c) Secure screws in pullout
switch base into panel bracket. d) Re-insert Pullout Switch
handle
To wire switch follow the wiring diagram provided.
3.
Use solid or stranded COPPER wire only.
4.
Strip the supply and load wires by removing 1/2 inch of
5.
insulation.
Insert the wires under the proper terminal plates and
6.
tighten the screws firmly.
PROGRAMMING & OPERATING YOUR TIME SWITCH MECHANISM
SETTING THE TIME: Rotate clock face in a clockwise direction until proper time is displayed. In order to properly set time for AM or PM,
verify that black arrow on clock face matches the correct 24-hour clock setting (example: 6=6AM, 18=6PM). If it does not, rotate clockwise 1
complete turn for correct AM or PM setting.
SETTING “ON” and “OFF” TIMES: Set the captive trippers for
desired on/off sequence required.
OFF-Push trippers IN (toward center of clock)
•
ON-Push trippers OUT (away from center of clock)
•
MODES OF OPERATION: (Using 3-Position Rocker Switch)
Timer/AUTO: Automatic Time Switch operation according
•
to captive tripper’s on/off settings
OFF/Standby: Maintains proper clock time and Time Switch
•
program settings during periods of non-use.
ON: Used to override Timer/AUTO mode. User can turn the
•
Time Switch ON. Time Switch will remain ON until the user
switches back to TIMER/AUTO or OFF mode.
MODES OF OPERATION: (Using slide switch between dials)
INDEPENDENT: The 2 time switches work independently
•
INTERLOCKED: The contacts of right side time switch (#2)
•
is functional only when left side time switch (#1) is ON.
TORK, INC. • 888.500.4598 • www.TORK.com
A DIVISION OF
MODES
TIMER/AUTO
OFF/STANDBY
ON
NSi INDUSTRIES, LLC