NSi Industries DW200B User Manual

10
DW200B 3/21/07 11:44 AM Page 1
Holiday (H)
Date
10
13
14
15
16
17
18
19
20
21
22
23
24
11
12
1
2
3
4
5
6
7
8
9
Description
9
TABLE OF CONTENTS
Section Page
Capabilities & Features . . . . . . . . . . . . . 1
Installation Instructions . . . . . . . . . . . . . 2
Instructions for Setting the Unit . . . . . . . 3
1.0 To Set The Clock . . . . . . . . . . . . . . . . . . 4
1.1 To Modify Clock . . . . . . . . . . . . . . . . . . 4
(After previously Set)
2.0 To Set Date . . . . . . . . . . . . . . . . . . . . . . 4
2.1 To Modify Date . . . . . . . . . . . . . . . . . . . 4
(After previously Set)
3.0 Daylight Saving Time . . . . . . . . . . . . . . 4
4.0 Holiday Dates . . . . . . . . . . . . . . . . . . . . 5
5.0 Scheduling ONs, OFFs . . . . . . . . . . . . . 6
6.0 Review, Modify, Delete schedules . . . . . 7
7.0 Manual Override . . . . . . . . . . . . . . . . . . 7
Clear All Memory . . . . . . . . . . . . . . . . . 8
Blank Schedule sheets . . . . . . . . . . . . . 9-10
DW200B 3/21/07 11:44 AM Page 3
HSUSAFRTHWETU
OFFONTimeLoad Description MO
Sch.#
CH2, simply press the EVENT key again. If there is no schedule programmed for CH1 or CH2, the display will show --:--
NOTES:
1. Unit will go to RUN MODE automatically if no key is pressed for five minutes.
2. Unit has a look back feature. If you have just finished setting the unit and an output is to be updated, press the EVENT key. Unit will automatically pick up the last schedule.
3. Clear all memory. To clear all memory, while in the RUN mode, press ENTER, display will show:
Use the EVENT key to display:
Now Press ENTER briefly and everything in the timer memory is wiped off including real time, date and 12HOUR will flash.
8
NOTE: AFTER MAKING ANY CHANGES TO THE PROGRAM, PRESS MODE TO GO TO RUN MODE AND THEN PRESS EVENT TO UPDATE THE LOAD STATUS.
TORK MODEL DW200B
2 CHANNEL DIGITAL TIME SWITCH
CAPABILITIES & FUNCTIONS
CAPABILITIES
365 Day Advance, Single Day Holiday. ON and OFF setpoints:
- Combined total for both channels – 99 per week
- Minimum setting – 1 minute
Capable of different schedules each day of the week.
FEATURES Holidays 1 to 24 individual dates. Daylight Saving Automatic (can be adjusted) Leap Year Automatic compensation Display LCD Manual Override Until the next regular scheduled
ON or OFF. Automatic operation then resumes.
Clock Format AM/PM or 24 Hour Look Back Automatically executes the last
command after power failure.
Power Outage Permanent schedule retention for
up to 40 years. Clock maintained for 4 days on super cap. No battery needed.
1
DW200B 3/21/07 11:44 AM Page 5
ON
OFF
ON
OFF
Follow the same procedures above to set more schedule entries for channel 1. At the next blank screen press SELCT to select desired channel and proceed with the steps above to set more schedule entries.
6.0 REVIEW, MODIFY AND DELETE
Press MODE to advance to any of the following MODES:
1. CLOCK MODE: Press HOUR and MIN to modi- fy existing settings. Press ENTER.
2. DATE MODE: Press MONTH, DATE and YEAR to modify existing settings. Press ENTER.DAY is automatically adjusted.
3. DST Daylight Saving Time: To review press
ENTER. To modify press MONTH, DATE and DAY to change existing setting. Press ENTER.
4. HOLIDAY MODE: Press ENTER to advance to desired holiday. Press MONTH and DATE to modify, DEL to delete. Press ENTER.
5. SCHEDULE MODE: Press ENTER to advance to desired channel. Press HOUR, MIN, EVENT to modify time settings. Press SELCT and DAY to modify days and/or holiday, DEL to delete. Press ENTER after each modification.
6. RUN MODE: Time, day and seconds are dis­played. If today is a programmed holiday, an H (Holiday) will be displayed steady.
7.0 OVERRIDE OVR1 and OVR2 (override keys) are effective only
in the run mode. If a channel is schedule for ON/OFF, then the channel will change the present load status until the next scheduled event. CH# will flash when the load is overridden from scheduled event.
EVENT (in the RUN mode) key is used to update the load status. It will execute the last scheduled event for CH1 and CH2.The display will only show the last sched­uled event for CH1. To view the last schedule event for
7
INSTALLATION INSTRUCTIONS
1. Remove unit from enclosure by pushing the inside tab (located near the outside hasp) to the right. Swing unit to left and remove.
2. Five combination 1/2” and 3/4” knockouts are provid­ed on this enclosure. Remove the 1/2” (inner) knock­out by inserting a screwdriver in the slot provided and pound screwdriver handle with a hammer. Remove knock-out with pliers and smooth hole edges with file and knife if necessary. When the 3/4” outer knockout is required, place screwdriver in groove and pound screwdriver handle with hammer. Remove loose knock-out with pliers and smooth hole edges with file or knife if necessary.
3. When attaching conduit to enclosure, exercise care to align and support conduit in order to prevent unnec­essary stress on enclosure.
4. Reinstall unit by reversing step 1 above and connect wires according to wiring diagram on inside case label.
GROUNDING
National Electrical Code requires that grounding must be continuous and in proper electrical contact in all ground­ing conductors, metallic conduits and grounding termi­nals. When using metal conduits, install the proper size approved grounding bushings. The minimum size copper grounding conductors must be #10 AWG if the circuit breaker or fuse is 30 or 40 amp, #12AWG if 20 amps, and #14 AWG if 15 amp.
NOTE: Do not use top entry for wiring
WE SUGGEST YOU MAKE COPIES OF THE SCHED­ULE SHEETS LOCATED IN BACK OF THIS BOOKLET AND COMPLETE THEM PRIOR TO SETTING THE UNIT.
2
Disconnect power at main panel prior to installing or servicing this time switch or the equipment connect­ed to it. Connect in accordance with national and local electrical codes. Installation by a licensed electrical contractor is recommended.
DW200B 3/21/07 11:44 AM Page 7
Press MONTH and DATE to set holiday 1 and then press ENTER. The display will show:
To delete any holiday press DEL and press
ENTER.
NOTE: a. A total of 24 holidays can be set, all following the
same schedule.
b. For any holiday to be used, the MONTH and DATE
must be preset.
5.0 SCHEDULE SET MODE
Press MODE until display shows:
Press SELCT to select channel 1 or 2.
5.1 SETTING HOURS AND MINUTES
a. Press HOUR and MIN to set desired time. b. Press EVENT to set desired event.
5.2 SETTING DAYS AND HOLIDAY
Press SELCT to select the flashing desired days and/or holiday, otherwise press DAY to skip and then press ENTER. To delete entry, press DAY until previously selected entry flashes, press SELCT and then press ENTER. The display will show:
6
INSTRUCTIONS FOR SETTING THE UNIT
Connect unit to main po
wer source prior to entering the settings. When powering up the unit for the first time, allow 1-2 minutes to charge the supercap and the dis­play will show 12 HOUR.
Press HOUR to change to 24 hour (military format) or Press ENTER to set 12 hour (AM/PM format).
NOTES:
1. During the RUN mode, the Hour, Minutes, Seconds,
Day of week and flashing colons will be displayed.
2. The unit will not go into run mode unless the clock
and date is set. In any other mode, if no entries are made for 5 minutes, the unit will automatically go to the run mode.
3. Unit will display “PF” (Power Failure) in the absence of
AC power. A minimum of 8 hours is required to fully charge the super cap.
4. When previously programmed unit comes back from
a power failure, it will “look back” and update the schedule, executing the last scheduled event. If a sig­nal setting was scheduled, after power failure the unit will execute the last scheduled signal. Settings can be manually updated by pressing the EVENT key in the run mode.
After pressing ENTER the unit will display:
3
NOTE: AFTER MAKING ANY CHANGES TO THE PROGRAM, PRESS MODE TO GO TO RUN MODE AND THEN PRESS EVENT TO UPDATE THE LOAD STATUS.
DW200B 3/21/07 11:44 AM Page 9
MO TU WE TH FR SA SU H
CH1 2 3 4 ASTRO SEASON 1 2 3 4
SIG1 SIG2 CLK DATE SCH
CH1 2 3 4 ASTRO SEASON 1 2 3 4
SIG1 SIG2 CLK DATE SCH
SIG1 SIG2 CLK DATE SCH
If daylight savings is required, press ENTER , dis­play will show:
Press ENTER to accept default dates (second Sunday in March) or press MONTH, DATE, and DAY to modify DST settings and press ENTER. The display will show:
Press ENTER, display will show:
Press ENTER to accept default dates (first Sunday in November) or press MONTH, DATE, and DAY to modify DST settings and press ENTER. Press
MODE, the display will show:
NOTE: DST OFF indicates Daylight Savings Time
was not set.
4.0 SET INDIVIDUAL HOLIDAY DATES
Press MODE until display shows:
5
1.0 TO SET THE CLOCK
Press HOUR and MIN to advance to the present hour and mins. Check AM/PM, and press ENTER.
1.1 TO MODIFY CLOCK Press MODE until the display shows: CLK. Press HOUR and MIN. to modify clock and press ENTER.
2.0 TO SET DATE
If you are setting for the first time, display will show:
Press MONTH, DATE, and YEAR key to advance to the desired month, date and year, then press
ENTER. NOTE: The day of the week will be automatically
set once the date is set.
2.1 TO MODIFY DATE Press MODE until the display shows DATE. Press MONTH, DATE and YEAR to modify present set- tings and then press ENTER.
3.0 DAYLIGHT SAVING TIME
After setting or modifying the date, display will show:
NOTE: If daylight saving time (DST) is NOT required, press MODE, display will show:
4
DW200B 3/21/07 11:44 AM Page 11
SIG1 SIG2 CLK DATE SCH
MO TU WE TH FR SA SU H
MO TU WE TH FR SA SU H
ON
OFF
ON
OFF
MO TU WE TH FR SA SU H
Loading...