NScessity NSUH-342 Instruction Manual

ULTRASONIC HUMIDIFIER
NSUH-342
Please read this instruction manual before operating and keep
safe for future reference.
Important Safety Instructions
When using any electrically powered product, basic safety precautions should always be followed.
PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE USING THE PRODUCT.
z Check the household voltage to ensure it matches the units rated specification
before operating.
z Close supervision is necessary when the unit is used near children or pets, or
left unattended.
z Do not allow children to play with any packaging, such as plastic bags. z If the supply cord is damaged it must be replaced by the Manufacturer or an
authorised service centre in order to avoid a hazard. If the product malfunctions, or has been dropped or damaged in any way. Return the complete product to an authorised service facility for checking and repair.
z This produ ct is intended for domestic use only and not for comme rcial, industrial
or outside use.
z Always turn the unit off, unplug and empty the water tray before moving it. z To disconnect from the power supply, grip the plug and pull from the power
socket. Never pull by the cord.
z Do not operate the unit in areas where petrol, paint, or other flammable liquids
are used or stored.
z Do not use the unit in artificially hot or humid conditions or allow it to be used in
any hazardous environment.
z Do not place the unit near an open flame, cooking or heating appliance, or hot
surface.
z This unit is not intended for use in wet or damp locations. Never locate the unit
in an area where it may fall into a bath or other water container. Always use on a dry level surface.
z Do not let the power cord hang over the edge of a table or counter. Arrange the
power cord away from an area where it may be tripped over.
z Never place the po wer cord under a carpet or rug. z Do not place objects on th e product or allow obje cts t o obstruct the inlet or outlet
openings. Do not operate in close proximity to walls or curtains, etc.
z The use of att achment s or accessories not recommended or sold b y the product
distributor is not recommended as they may cause injury to persons or property and void the warranty.
z Do not attempt to repair the unit other than to clean the tank and transducer. To
repair the unit take it to a qualified service engineer.
z Do not allow water to run inside the humidifier as this could result in a fire or
electric shock.
READ AND SAVE THESE INSTRUCTIONS
Please read this User Guide carefully before using:
Do not use your humidifier in a closed room; excessive moisture may build up if there is insufficient ventilation in the room. If moisture forms on the walls or windows you should turn the humidifier off or decrease the output as the room has plenty of moist air and additional moisture may cause damage.
Locate your humidifier in an area inaccessible to children.
Never direct the mist spray outlet (15) directly towards electronic
equipment, a wall or piece of furniture.
Do not place your humidifier on a rug, carpet or finished surface that may be damaged by excess moisture.
Wallpaper and wooden surfaces can be damaged by excessive moisture.
For extra protection place a waterproof pad under the humidifier.
Do not block the mist spray outlet (15).
Do not add any oils or perfumes to the water in the tank
Features of NSUH-342
Automatic switch off If the water level drops below a preset level the unit will automatically shut-off to prevent damage.
Output Adjustment The output selection knob allows you to continuously adjust the output. You can select an ideal output in line with the indoor environment.
Humidity display function This product comes with a hygrometer. This indicates the current ambient humidity range. The indicator on the hygrometer is colour coded to ease use. When the indicator points to yellow area, it indicates low humidity; when it points to green area, it indicates ideal humidity; when it points to blue area it means high humidity.
Parts Description NSUH-342
1) Power cable
2) Main Switch/Output adjust knob
3) Power light
4) Transducer
5) Water level protection Switch
6) Water Basin
7) Base unit
8) Air outlet
9) Arrow for water outlet direction
10) Water Tank Cover
11) Silencer
12) Mist conduct
13) Water Tank
14) Water Tank Handle
15) Nozzle
16) Hygrometer
Operating Instructions
This humidifier should be placed under ambient temperature for half an hour before it is put into use for the first time. The desired operating environment for this humidifier is:
Temperature: 5
Relative humidity: maxi mum 80%RH
Use clean water, temperature below 40C (purified water is recommended) Clean the Water Basin and Water Tank after long storage. It is normal to find a small quantity of water remaining in the Water Tank when the unit has stopped running.
Remove the Water Tank and turn it upside down. Remove the tank cap and fill with fresh cold water (never use hot water). Put the cap back onto the Water Tank tightly and place the Water Tank back onto the Base Unit.
Put the Nozzle into the slot at the top of the Water Tank.
Connect the Power Cabl e and switch on the Main Switch (turning on
the Main Switch without water can cause damage the unit). The Power Indicator light will be turned on and the unit will begin to function.
Adjust to the desired output by tuning the adjustment dial clockwise to increase output or anti-clockwise to decrease output.
When all the water in the tank has been used the humidifier will stop. Unplug your humidifier, remove the tank and refill it with cold water following the instructions outlined above. Please ensure you unplug the unit before re-filling.
IMPORTANT
NOTE
DO NOT LEAVE ANY WATER IN THE HUMIDIFIER WHEN YOU STOP USING IT. WATER LEFT IN THE HUMIDIFIER MAY CAUSE BACTERIAL GROWTH THAT COULD HARM THE HUMIDIFIER'S PERFORMANCE
YOUR HUMIDIFIER REQUIRES REGULAR CLEANING TO PREVENT THE BUILD UP OF IMPURITIES & BACTERIA. WE RECOMMEND THAT YOU RINSE THE TANK EVERY DAY AND CLEAN YOUR HUMIDIFIER EVERY WEEK.
O
C-40OC
DO NOT USE WITHOUT NOZZLE FITTED CORRECTLY
Daily maintenance
z Unplug the humidifier. z Empty the water tank and rinse with water, use a brush or soft cloth to
remove any stains from the inside and outside.
Weekly maintenance
z Unplug the humidifier. z Empty the water tank. Disinfect the tank by adding 5ml (1 teaspoon) of
(depending on usage)
bleach to approximately half a tank of cold water. Replace the tank cap; shake the tank to allow all the surfaces to be come wet. Leave the solution in the tank for about 20 minutes, shaking the tank every few minutes to keep all the surfaces wet.
z Alternatively substitute a sterilising solution, suitable for Baby’s feeding
products.
z Empty the water tank and rinse thoroughly to remove any bleach smell. z Clean the water channel with a damp soft cloth. z Gently scrub the area around the transducer with a soft brush. If scale
has built up in this area it can be removed with a descaler suitable for plastic kettles. Do not turn your humidifier on during the cleaning or descaling process.
BS Plug Wiring
Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code:
BLUE – NEUTRAL BROWN - LIVE
z The BLUE wire is the NEUTRAL and must be connected to the
terminal that is marked with the letter N or coloured BLACK.
z The BROWN wire is the LIVE and must be connected to the terminal
that is marked with the letter L or coloured RED.
z Neither wire is to be connected to the terminal which is marked with
the letter E or or coloured GREEN OR GREEN/YELLOW.
z Always ensure that the cord grip is
positioned and fastened correctly.
If a 13A (BS 1363) fused plug is used it must be fitted with a 3A fuse. If in doubt consult a qualified electrician.
Specifications
Standard Output: 250ml/hr Capacity of water tank: 3.4L Noise level: 35dBA Rated Voltage: 230V~ Rated Frequency: 50Hz Power: 35W
Storage Instructions
When the product is left unused over a period of time, ensure that both the water tank and water channel are clean. After cleaning, leave it to dry and return to the original box for storage.
Product Disposal Information
Do not mix products bearing the crossed out bin symbol with your general household waste. For the correct collection and treatment of these products take them to the collection points designated by your local authority. Alternatively contact the retailer who sold you the product.
Service & Warranty
NScessity Products guarantees this product free from defects in materials and workmanship for a period of one (1) year. Should this unit be operated under conditions other than those recommended, at voltages other than the voltage indicated on the unit, incorrect battery operation, or any attempts made to service or modify the unit, this will render this WARRANTY VOID. The product you buy may sometimes differ slightly from illustration. This warranty is in addition to, and does not affect, your statutory rights.
Should you have a problem with this product, please contact our help desk, Tel: 0870 765 2574.
This product has been manufactured to comply with EEC Directives
73/23/EEC and 89/336/EEC
NScessity Products GU8 6BD
NSUH-342/IM/01
Trouble Shooting Guide
If in the event your unit is not working, please check the following
Fault Symptom Analysis How to fix
Power light off, no airflow and no mist
airflow but no mist
Peculiar smell from/in the Water Tank
Power light on, no airflow and no mist
Small Output
Abnormal noises
Mist flowing down unit not out of Nozzle Water in Tank doesn’t flow down
Power Cable unconnected Connect Power Cable Main Switch off Switch on the Main
Switch No water in the Water Tank Fill water into Water Tank Power light on, with Water Level Switch is not at the proper position Brand new product
Dirty water or water stayed in the Water Tank too long
Water level too high in the Water Basin Too much scale on Transducer Dirty water or water stayed in the Water Tank too long
Too less water in Water tank Fill more water into the
Unit is standing on uneven or leaning surface There are gaps between Nozzle and Water Tank
The movement of the Rubber Seal in the Tank Cover is blocked
Reinstall the Water Level
Switch Cover
Leave Tank Cover open in
cool place for 12 hours
Clean Water Tank and
replace/fill with fresh
clean water
Take out some of the
water from the Basin
Clean Transducer
Clean Water Tank and
replace/fill with fresh
clean water
Water Tank
Place the unit on flat,
stable surfaces
Ensure lid is fitted
correctly.
Clean the tank cover to
remove the sticky dirt and free the Rubber Seal.