Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Reverse Current 15mA
Forward Current 10mA
Storage Temperature −60˚C to +150˚C
Operating Temperature Range (Note 2)
LM136-5.0 −55˚C to +150˚C
LM236-5.0 −25˚C to +85˚C
LM336-5.0 0˚C to +70˚C
Soldering Information
TO-92 Package (10 sec.) 260˚C
TO-46 Package (10 sec.) 300˚C
SO Package
Vapor Phase (60 sec.) 215˚C
Infrared (15 sec.) 220˚C
See AN-450 “Surface Mounting Methods and Their Effect on
Product Reliability” (appendix D) for other methods of soldering surface mount devices.
Electrical Characteristics
(Note 3)
LM136A-5.0/LM236A-5.0 LM336B-5.0
Parameter Conditions LM136-5.0/LM236-5.0 LM336-5.0 Units
Min Typ Max Min Typ Max
Reverse Breakdown Voltage T
A
=
25˚C, I
R
=
1mA
LM136-5.0/LM236-5.0/LM336-5.0 4.9 5.00 5.1 4.8 5.00 5.2 V
LM136A-5.0/LM236A-5.0, LM336B-5.0 4.95 5.00 5.05 4.90 5.00 5.1 V
Reverse Breakdown Change T
A
=
25˚C, 6 12 6 20 mV
With Current 600 µA≤I
R
≤10 mA
Reverse Dynamic Impedance T
A
=
25˚C, I
R
=
1 mA, f=100 Hz 0.6 1.2 0.6 2 Ω
Temperature Stability V
R
Adjusted 5.00V
(Note 4) I
R
=
1 mA, (
Figure 2
)
0˚C≤T
A
≤70˚C (LM336-5.0) 4 12 mV
−25˚C≤T
A
≤+85˚C (LM236-5.0) 7 18 mV
−55˚C≤T
A
≤+125˚C (LM136-5.0) 20 36 mV
Reverse Breakdown Change 600 µA≤I
R
≤10 mA 6 17 6 24 mV
With Current
Adjustment Range Circuit of
Figure 1
±
1
±
1V
Reverse Dynamic Impedance I
R
=
1 mA 0.8 1.6 0.8 2.5 Ω
Long Term Stability T
A
=
25˚C
±
0.1˚C, I
R
=
1 mA, t=1000 hrs 20 20 ppm
Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. Electrical specifications do not apply when operating thedevice
beyond its specified operating conditions.
Note 2: For elevated temperature operation, T
j
max is:
LM136 150˚C
LM236 125˚C
LM336 100˚C
Thermal Resistance TO-92 TO-46 SO-8
θ
ja
(Junction to Ambient) 180˚C/W (0.4" Leads) 440˚C/W 165˚C/W
170˚C/W (0.125"
Leads)
θ
ja
(Junction to Case) N/A 80˚C/W N/A
Note 3: Unless otherwise specified, the LM136-5.0 is specified from −55˚C≤TA≤+125˚C, the LM236-5.0 from −25˚C≤TA≤+85˚C and the LM336-5.0 from
0˚C≤T
A
≤+70˚C.
Note 4: Temperaturestabilityfor the LM336 and LM236 family is guaranteed by design. Design limits are guaranteed (but not 100%percent production tested) over
the indicated temperature and supply voltage ranges. These limits are not used to calculate outgoing quality levels. Stability is defined as the maximum charge in
V
REF
from 25˚C to TA(min) or TA(max).
www.national.com3