National Rejectors, Inc. GmbH • Zum Fruchthof 6 • D-21614 Buxtehude • Telefon 04161/70 75 0 • Telefax 04161/70 75 55
Page 2
Manual G-26.4000:
Advantages
National Rejectors, Inc. GmbH, GermanyPage 2
Benefit from the Advantages of the NRI Changers
G-26.4000 Standard, G-26.4400 SIMPLEX V and G-26.4800 Professional
Increased sales
o 20-30% increase in sales with a changer
o Greater change capacity
o Sales audit information to optimize machine usage
o Up to 12 different denomination coins accepted (including up to 3 tokens)
Economical auditing
o Record of
- sales
- machine data
o Data printout
o Data display
o Readout of data by a data retrieval unit
Security
o Reliable validation
o Low power consumption
10 prices(G-26.4000 Standard)
o Quick simple price changing
Fast servicing
o Simple modular construction
Ready for new market requirements
o Re-programmable validator
- change of coin acceptance
- quick response to new frauds
o Use of a bill validator
o Use of a talking module
o Use of a card system
Setting Time and Date 14 .................................................................... 38
Single Coin Inhibit 15.......................................................................... 40
Printout Format 16 .............................................................................. 42
Coins to be inhibited 17 ...................................................................... 47
Communication with Audit Unit 18 .................................................. 49
Communication with a Card System 19 ............................................ 50
Communication with a Bill Validator 20........................................... 51
Communication with a Talking Module 21 ...................................... 52
Setting of ‘tube empty’ condition 22 ................................................. 53
Page 4
Manual G-26.4000:
General
National Rejectors, Inc. GmbH, GermanyPage 4
1. General
The G-26.4000 Standard, G-26.4400 SIMPLEX V and the G-26.4800 Professional are 3-tubechangers, accepting up to 12 different coin denominations, including up to 3 tokens, between 15 and
33 mm diameter.
Connection between changer and vending machine:
G-26.4000 Standard- parallel interface
G-26.4400 SIMPLEX V- serial interface
G-26.4800 Professional- serial interface
Payout of three different coins:
right tube-coins up to 30 mm diameter
left tube-coins up to 26.5 mm diameter
middle tube-coins up to 23.5 mm diameter
The tubes may store the same denomination coin to increase capacity.
The validator and changer each have their own microprocessor. Both processors communicate via a
serial interface.
Using a P.C., the validator is ‘self-teaching’ enabling reprogramming of coin acceptance.
It is possible to use a card system or bill validator with the changer (see functions 19 and 20).
In addition, you can record data using a data retrieval unit. This data can be used for audit purposes.
By connecting a talking module G-58.0100 to the changer, your vending machine can become more
appealing.
Page 5
Manual G-26.4000:
General
Page 5National Rejectors, Inc. GmbH, Germany
The changer series G-26.4800 Professional contains a further version, the so-called ‘BDV-Standard’.
For this device the keyboard is optional.
With a BDV-Standard device without keyboard several functions, described hereafter, are therefore
only possible by the vending machine control.
Note:
When using a G-26.4800 Professional the values, set with function 3,4,15,17 and 19, can be
overwritten by the vending machine control. Thus it is preferable to set these functions by the vending
machine control.
Differences:
ProfessionalBDV Standard
external display
connectableyesno
keyboard with internal
displayexistingoption
printout of data
readout with data retrievalpossiblenot possible
unit
functionsadjustable byadjustable by
keyboard orvending machine´vending machine or
vending machineor keyboardoptional keyboard
connection of bill validatorpossibleonly possible
or talking modulewith option
keyboard
Page 6
Manual G-26.4000:
Technical Data
National Rejectors, Inc. GmbH, GermanyPage 6
2. Technical Data
Acceptance:Up to 12 different coin denominations, incl. 3 tokens
Diameter:15 - 33 mm
Thickness:1.5 - 3.3 mm
Change capacity:Approximately 70 coins per tube
(depending on thickness)
Dimensions:Height: 380 mm
Width: 137.5 mm
Depth: 82.5 mm (89.5 mm when operating the return lever)
Mounting:Vertical (to within 2°)
Weight:Approximately 4 kg
Temperature:Operation: 0°C - +55°C
(Ambient temperature of the unit)
Storage: -30°C - +75°C
Humidity:Maximum 90%
Component spec:DIN 40 040 KSF
Power supply:115/230 Volts (European Standard)
110/220 V A.C., 120/240 V A.C.,
24 V A.C and 24 V D.C.
Power consumption:5 VA standby, 20 VA max.
Switching:For A.C. current max. 240 Volts, 2.5 A, 600 VA
For D.C. current max. 24 Volts, 50 mA short-circuit
The unit conforms with the technical specification of the regulation
1046/1984 of high frequency devices for ISM or similar purposes.
Page 7
Manual G-26.4000:
G-10.4000/5
Page 7National Rejectors, Inc. GmbH, Germany
3. Electronic Validator G-10.4000/5
General Information
The G-10.4000/5 is a microprocessor-controlled validator, which includes a serial interface for the data
transfer to the control unit.
Measurements
When a coin passes the measurement area within the validator, the coils measure the coin characteristics
of alloy, thickness, diameter and embossing. The measured analog values are recorded and processed
to 6 digital values.
For coin validation 6 parameters are available:
NFP = Phase shift measurement with low frequency
GRO = Diameter measurement with upper sensor
GRU = Diameter measurement with lower sensor
NFA = Amplitude measurement with low frequency
RCH = Calculated value
HFP = Phase shift measurement with high frequency
Coin channels
The inserted coin generates one value for each of the 6 parameters. The validator checks, whether this
value lie within its programmed limits, i.e. within the coin channel.
Within each channel the limit values for one coin denomination can be set. The 12 coin channels of the
G-10.4000/5 enables the coin acceptance of a maximum of 12 different coin denominations. This means
coins, whose characteristics correspond. Thus this also refers to tokens. Based on this there are two
coin channels programmed instead of only one in case of the acceptance of an old and new coin
denomination (for instance 0.10 £ old and 0.10 £ new).
Alternatively it is possible to programme a channel with 'normal bandwidth' and with 'narrow bandwidth'
for the same coin denomination.
To each coin channel one coin denomination can be assigned.
The G-10.4000/5 can validate up to a maximum of 8 different coin values. The coin channels 9 to 12
are linked up with the coin channels 1 to 8 and thus a coin value is assiged to these coin channels.
Page 8
Manual G-26.4000:
G-10.4000/5
Linked channels always accept the same coin value.
Example I:
Example I: Label of a G-10.4000/5 with German coin acceptance.
National Rejectors, Inc. GmbH, GermanyPage 8
This example shows the the coin channels 3 and 10, 4 and 11 as well as 5 and 12 are linked
together. The abbreviation "E" markes the channels with 'narrow' bandwidth. So for the same coin
denomination two channels are programmed, one with 'normal' and the other with 'narrow'
bandwidth.
Example II
Example II: Label of a G-10.4000/5 with English coin acceptance.
The example shows that the channels 2 and 10, 3 and 11 as well as 8 and 9 are linked together.
Different coin denominations are accepted, however, they have the same coin values.
Page 9
Manual G-26.4000:
G-10.4000/5
Page 9National Rejectors, Inc. GmbH, Germany
Individual coin inhibit
It is possible to inhibit each of the channels 2 to 12.
The channels 2 to 8 can be inhibited via keyboard of the changer ( see function 15).
If one of the channels 2 to 8 is inhibited via the keyboard of the changer, the assigned channel,
accepting the same coin value, is simultaneously inhibited.
Example:
Programmed coin value within channel 5 (narrow bandwidth) : 1.00 £
Programmed coin value within channel 12: 1.00 £
Due to the fact that channel 5 and 12 are linked together if the coin acceptance is inhibited within
channel 5, channel 12 is also inhibited.
In order to inhibit the coin acceptance of channels 9 to 12 a 4-pole Dual-In-Line switch is
provided on the pc-board of the G-10.4000/5 (see figure).
To get free access to the Dual-In-Line switch it is necessary to remove the G-10.4000/5.
Position of the Dual-In-Line switch on the CPU pc-board of the validator.
Page 10
Manual G-26.4000:
G-10.4000/5
o The channels 9 to 12 are assigned to the 4 switches as follows:
National Rejectors, Inc. GmbH, GermanyPage 10
* By moving the appropriate switch in the upper position ( 'open' ) the channel is inhibited.
By using the individual coin inhibit of channels 9 to 12 it is possible, for instance,
-to increase the slug rejection by inhibiting the channels with normal bandwidth for
changers with German coin acceptance
-to inhibit the coin acceptance of old coins, if they should no longer be accepted for
changers with English coin acceptance.
Coin sorting
The validator is able to sort coins into 3 different tubes or into the cashbox. The assignment of the coins
into tubes is done by the channels and is independent from the coin value.
During the sorting procedure the sorting gates are activated dependant on the time the inserted coin
requires to pass through the validator. Thus a fast coin requires a short sorting time. This individual
activation of the sorting gates increases considerably the sorting security.
Switch 1 in the lower position of the 4-pole Dual-In-Line switch has two functions. By using this
switch you can activate the sorting function (see page 11).
Page 11
Manual G-26.4000:
G-10.4000/5
Page 11National Rejectors, Inc. GmbH, Germany
The sorting function - special function for validators with English coin acceptance - can be
activated by using switch 1,
-if within channel 12 no coin is programmed,
-if the coin denomination, accepted by channel 9, is guided into the right tube
* Move switch 1 on the 4-pole Dual-In-Line switch in the upper position
o Now coins accepted within channel 9 are no longer guided into the right tube, but coins
accepted within channel 8 are guided into the right tube.
Attention: If within channel 12 a coin is programmed, the coin denomination within channel 9 must
not be sorted into the right tube as during inhibit of channel 12 (using switch 1) the sorting
changes from channel 9 to channel 8.
Page 12
Manual G-26.4000:
G-10.4000/5
National Rejectors, Inc. GmbH, GermanyPage 12
NRI Programming Unit
NRI offers a programming station by which you can change the settings according to your
requirements.
By using the NRI programming station for validators series G-10.4000/5 you can
-check the proper function of the connected validator,
-if necessary, determine the reason for a fault
-change the programming
-display the actual measured values of an inserted coin
-programme the coin channels by inserting special coins
-change the validator setting in order to adapt it to the desired vending machine.
A programming station for the G-10.4000/5 includes the following units:
G-55.0287 adapter (for AT computers) with 9-pin plug
or
G-55.288 adapter (for XT computers) with 25-pin plug
G-19.0577 tester
G-19.0584 test stand
93 00 631 software 'KUNEMP', deliverable on 5.25" or 3.5" disk
The software 'KUNEMP' can also be used for the validator series G-18.3000.
You can connect the NRI programming station to an IBM personal computer or compatible with
a RS232 interface.
Page 13
Manual G-26.4000:
Transport/Connection
Page 13National Rejectors, Inc. GmbH, Germany
4. Transport and Connection of Unit
Transport
o Before transport please empty all tubes
o Transport and storage in factory packing prevents damage
o No transit fixings required
Attention
Components behind validator are at line voltage.
Always unplug changer before removing validator.
Always refit the safety screw.
Prior to installation
* Check that changer is correct for your machine
* Check operating voltage and change if necessary (switch S1 on interface module)
(Only units for 110.. 240 Volts).
Installation
o Connecting cable to vendor must not yet be plugged
* Mount changer
* Unfasten safety screw (see figure)
* Remove validator
* Secure changer with screws
* Refit validator
* Fix safety screw
* Connect non-fused green/yellow earth lead
* Plug to machine
* Check that motors are in standby state (key ‘+’ twice)
* Fill change tubes with at least 20 coins each (see ‘Filling Change Tubes’ page 18)
Page 14
Manual G-26.4000:
Functions
National Rejectors, Inc. GmbH, GermanyPage 14
5. Description of Operating Modes
Note: The functions described hereafter can be set within units including the latest software. If
necessary, please contact NRI.
ModeReasonSelect
o Inventory- to relocate changer01
- servicing
Emptying tubes- inventory
- transport
o Price setting02
(G-26.4000 Standard)
o Machine number02AU
o Acceptance limit- prevents misuse as0301
changemaker
All coins are inhibited once
acceptance limit is reached
o Change limit- maintains change store0302
Limited change given
Only effective within mode ‘multi-vend’
o Setting of tokensSetting value of up to three0303
different tokens possible.
o Single vendCoins inserted for each vend.04
Changer inhibits coin
Change given after each vendacceptance, when credit exceeds
automaticallyhighest price.
o Multi-vendMore than one vend may be04
made without inserting coins
Change after vends andfor each.
reject operation
o Committed to vendPrevents misuse as changemaker04
Vend must be made before
change given
o Uncommitted to vend04
Change returned at any time
Page 15
Manual G-26.4000:
Functions
Page 15National Rejectors, Inc. GmbH, Germany
ModeReasonSelect
o External reset04
(G-26.4000 Standard)
Vending machine provides
reset signal
o Internal resetPrice pulse 75 up to 100 msec04
(G-26.4000 Standard)
No reset signal from
vending machine
o Reset via 6Determined by machine.04
(G-26.4000 Standard)Only effective in connection
with ‘external reset’.
o Reset via 8Determined by machine.04
(G-26.4000 Standard)Only effective in connection
with ‘external reset’.
Lamp ‘exact change’Customer can buy, however, he
lights up (unchangeable)possibly has to renounce his
residual money. Money which cannot
be paid back, will remain as credit.
Note:o The ‘exact change’ lamp now solely depends on
the ‘tube empty’ condition, set on function 22.
o When coins are still in the tubes, they are paid out even in
case of 'tube empty' display.
o Residual credit, due to insufficient change, remains.
o Change is paid back in lowest number of available coins.
o Blocking of coinsCoins set by function 1704
when ‘tube empty’are not accepted when the
(unchangeable)‘tube empty’ condition is
fulfilled.
o Display of timeWhen credit = 00.00 the0401
time can be displayed.
Page 16
Manual G-26.4000:
Functions
National Rejectors, Inc. GmbH, GermanyPage 16
ModeReasonSelect
o Display of credit inPrior to payout of residual0401
'single vend'money, credit is displayed
for 2.5 seconds.
o Delayed resetAfter reset, price line remains0401
active for 300 msec.
o Cigarette modeActivation of the cigarette0401
mode is independent from
validator setting.
o Ecological functionDiscount possible, if no cup0401
is used.
o Data displayAudit purposes
- vending machine data05
- sales data06
- vend / sales data08-09
- vend sales data per price line (G-26.4000 Standard)10-11
- coin and tube data12
o DiagnosticsServicing13
o Time/date setting14
o Single coin inhibitAny coin may be inhibited15
o Printout formatShort or full data16
o Coins to be inhibitedApplicable during ‘tube empty’17
condition (function 22)
o Communication with18
audit unit
o Communication with19
card system
o Communication with20
bill validator
o Communication with21
talking module
o Setting of ‘tube22
empty’ condition
Page 17
Manual G-26.4000:
Initial Operation
Page 17National Rejectors, Inc. GmbH, Germany
6. Initial Operation
* Check
- supply voltage
- vending machine compatibility
- vending machine interface
* Connect earth wire to housing of vendor.
Good metallic contact is absolutely necessary.
* Connect changer
* Switch on
- external display shows 00.00 or time or residual credit
* Check operating modes are correctly set (function 04)
* Check that motors are in standby state (key ‘+’ twice)
* Fill each tube with at least 20 coins (see ‘Filling Change Tubes’ page 18)
* Check setting of time and date (function 14)
* Set prices (G-26.4000 Standard) and machine number (function 02)
* Check maximum change and credit (function 03)
* When tokens are accepted, check correct setting (function 0303)
* Check single coin inhibit (function 15)
* Check coin acceptance and correct credit display
* Test vend and check correct change dispenser
Changer is now ready for use.
Page 18
Manual G-26.4000:
Filling Change Tubes
7. Filling Change Tubes
It is preferable to fill tubes as follows:
o Unit in standby mode
* Press ‘+’ key
* Insert coins
* Press ‘+’ key
o Possibly existing credit remains unchanged.
Filling level of tubes: I-I = not empty
-= full
II= empty
National Rejectors, Inc. GmbH, GermanyPage 18
maximum filling level
Note:
-Before starting to fill tubes cashbox should be emptied, as coins guided into cashbox are not
counted.
-Even when keyboard is blocked filling of change tubes by pressing ‘+’ key is possible.
-Inserted coins will be audited.
-All coins are accepted, including the coins inhibited by function 15.
Additionally it is possible to fill tubes using function 1305 (see’Diagnostics’).
Page 19
Manual G-26.4000:
Display of Line Conditions
8. Display of Line Conditions
G-26.4000 Standard
(Remedying faults within vending machine)
o Changer in standby
* Key ‘+’
* Key ‘P’
o On display appears for example:
Page 19National Rejectors, Inc. GmbH, Germany
Where:
0060= price 60 p
01= selection line 1 active
The price of the selected product appears also on the external display. If another product is selected
the display shuts down temporary so that even if the price is the same the change to another selection
line is displayed.
For line conditions following displays are possible:
-6 = line 6 active (coin inhibit)
-8 = line 8 active (reset)
-9 = line 9 active (tube empty)
01 = selection line 1 active
.
.
06 = selection line 6 active
.
.
10 = selection line 10 active
* Key ‘P’
o Changer returns to standby
Page 20
Manual G-26.4000:
Test Vends
9. Test Vends
G-26.4000 Standard
o Changer in standby
* Key ‘+’
* Key ‘P’
* Key ‘E’
o On display appears:
National Rejectors, Inc. GmbH, GermanyPage 20
* If you select now for instance selection 1, the display will indicate:
This means that the vend operation for selection 1 (price: 60 p) is now initiated. When the vending
machine has finished the vend the following display is obtained:
If no further test vend is initiated, the display shows again the status indication for test vends (first
figure on this page) after 10 seconds. After approximately 40 seconds the changer returns to standby.
The number of test vends is counted and can be displayed within function 08 (vend data) under 0903.
Also the printout includes the number of test vends (second number under ‘cycles’).
* Key ‘P’
o Changer returns to standby.
Page 21
Manual G-26.4000:
Operating Keys
Page 21National Rejectors, Inc. GmbH, Germany
10. Operating Keys
Keys
F = Function select / Return to standby
E = Execute function / Rapid increase of values
P = Programming / Return to standby
+ = Increase of values
Display shuts down approximately 40 msec after last use of key.
Continuous depression of key gives rapid indexing forward.
Protection against unauthorized or inadvertent programme changes:
* Switch over switch on CPU pc-board (protected = left or upper plug position)
Note: Units with a model number higher than G-26.4000/4 have an additional switch on the interface
module. This switch must be in position ‘keyboard enabled’.
When keyboard is blocked the following functions are possible:
-function 01 (inventory)
Referring to the G-26.4800 Professional this function can be inhibited by the vending machine.
Thus function 01 can only be executed when either the keyboard is enabled or by the vending
machine.
-filling of tubes
-display of line conditions
-functions 19 and 20
All other functions are selectable. However, changes are not possible.
Page 22
Manual G-26.4000:
Flow Chart
National Rejectors, Inc. GmbH, GermanyPage 22
11. Flow Chart
standby
F
P or +emptying tubes (inventory) 01Eleft tubeFmiddle tubeFright tube
F
P or +pricing and machine no. 02Epricingmachine no. 02AU
F
P or +accept/change limit 03Eaccept limitationPchange limitationPsetting of token
F
P or +setting of operating modes 04Eoperating modes
F
operating mode 0401Eoperating modes
F
P or +vending machine data 05Emachine No.Eaudit No.Eon/off mains
F
P or +sales data 06Esales data
F
P or +vend data 08Evend totalsEvend subtotals
F
P or +sales/vends per price 10Esales per priceEvends per price
F
P or +coin and tube data 12Ecoin/ tube data
F
P or +diagnostics 13
F
P or +setting time and date 14Etime/date
F
P or +single coin inhibit 15
F
P or +printout format 16
F
P or +coins to be inhibited 17
F
P or +communication with audit unit 18
F
P or +communication with card system 19
F
P or +communication with bill validator 20
F
P or +communication with talking module 21
F
P or +setting of 'tube empty' condition 22
G-26.4000 Standard
G-26.4000 Standard
G-26.4000 Standard
after display
10th price
Page 23
Manual G-26.4000:
Page 23National Rejectors, Inc. GmbH, GermanyEmptying Tubes
12. Operation
Function 01 = Emptying tubes (Inventory)
ActionKeyDisplay
* Select functionF 01
* Inventory left tubeE01
I—
* Payout coins singlyE once
* Payout coins rapidlyE continuously
* Inventory middle tubeF01
-I-
* Payout coins singlyE once
* Payout coins rapidlyE continuously
* Inventory right tubeF01
—I
* Payout coins singlyE once
* Payout coins rapidlyE continuously
* Return to base functionF01
* Return to standbyP or +shuts down
Page 24
Manual G-26.4000:
Pricing and Machine No.
National Rejectors, Inc. GmbH, GermanyPage 24
Function 02 = Pricing and Machine Number
G-26.4000 Standard
ActionKeyDisplay
* Select functionF until02
02 appears
* Display price 1E0201
00.05
Assuming price 1 was displayed
* Display prices 2 to 10P sequentially
* Increase by lowest coin+ once0201
value00.06
* Multiple increase by lowest+ continuously0201
coin value00.30
* Rapid increase (100 timesE0201
lowest coin value)05.30
* Setting lower priceE and + simultaneously
until 00.00 appears, then
set price
* Programming or priceP0202
00.10
After display of price 10
Note: The machine number cannot be changed, if a data retrieval unit is used.
* Display machine numberP02AU
001234
* Change machine number (+ 1)+02AU
001235
* Change machine number (+ 100)E02AU
001335
* Setting of 5th and 6th digitE until desired02AU
number appears101335
* Return to base functionP02
* Return to standbyP or +shuts down
Page 25
Manual G-26.4000:
Machine No.
Page 25National Rejectors, Inc. GmbH, Germany
Function 02 = Machine Number
G-26.4800 Professional and G-26.4400 SIMPLEX V
Note: The machine number cannot be changed, if a data retrieval unit is used.
ActionKeyDisplay
* Select functionF until02
02 appears000000
* Display machine numberP02AU
001234
* Change machine number (+ 1)+02AU
001235
* Change machine number (+ 100)E02AU
001335
* Setting of 5th and 6th digitE until desired02AU
number appears101335
* Return to base functionP02AU
* Return to standbyPshuts down
Page 26
Manual G-26.4000:
Accept/Change Limit
National Rejectors, Inc. GmbH, GermanyPage 26
Function 03 = Acceptance and Change Limitation and Setting of Tokens
ActionKeyDisplay
* Select functionF until03
03 appears
* Display acceptance limitE0301
00.00
* Increase by lowest coin+ once0301
value00.01
* Increase by multiple of+ continuously0301
lowest coin value01.00
* Rapid increase (100 timesE0301
lowest coin value)06.00
* Display change limitP0302
00.00
* Increase by lowest coin+ once0302
value00.01
* Increase by multiple of+ continuously0302
lowest coin value00.50
* Rapid increase (100 timesE0302
lowest coin value)01.50
* Reduce to lower amountE and + simultaneously
until 00.00 appears,
then to setting required
Note: If the acceptance and change limitation is set to 00.00, the appropriate limit has no action.
Function 03 continued next page
Page 27
Manual G-26.4000:
Setting of Tokens
Page 27National Rejectors, Inc. GmbH, Germany
Function 03 = Acceptance and Change Limitation and Setting of Tokens
ActionKeyDisplay
* Display of set token 1P0303
00.10
* Increase by lowest coin+ once0303
value00.15
* Increase by multiple of+ continuously0303
lowest coin value00.40
* Rapid increase (100 timesE0303
lowest coin value)05.40
* Display of set token 2P0304
01.00
Changes as described above
* Display of set token 3P0305
02.00
Changes as described above
* Return to base functionP03
* Return to standbyP or +shuts down
Note: For each vend only one token is accepted, i.e. after insertion of a token the unit goes
automatically into mode ‘committed to vend’.Further insertion of coins is possible.
Page 28
Manual G-26.4000:
Operating Modes
National Rejectors, Inc. GmbH, GermanyPage 28
Function 04 = Operating Modes
ActionKeyDisplay
* Select functionF until04
04 appears
* Display of settingE04
(see next page)10000100
* Select digit to be changedP sequentially04
10000100
* Change setting+04
11000100
* Programme new settingP04
11000100
* Display of next settingF0401
(G-26.40000 Standard)00000000
* Change setting
- as described above -
* Return to base functionF0401
* Return to standbyP or +shuts down
Page 29
Manual G-26.4000:
Operating Modes
Function 04 = Operating Modes
Example: G-26.4000 Standard
Page 29National Rejectors, Inc. GmbH, Germany
1 = external reset )
0 = internal reset )
1 = committed to vend
0 = uncommitted to vend
1 = single vend
0 = multi vend
1 = ‘Exact change’ lamp lights up (unchangeable)
1 = reset line 6 )
0 = reset line 8 )
G-26.4000 Standard
= not yet used
1 = Blocking of coins when ‘tube empty’
(unchangeable)
G-26.4000 Standard
Page 30
Manual G-26.4000:
Operating Modes
Function 0401 = Operating Modes
G-26.4000 Standard
display of credit in ‘single vend’
display of time
National Rejectors, Inc. GmbH, GermanyPage 30
ecological function passive
cigarette mode passive
delayed reset
By inserting a ‘1’ following functions are selected:
Display of time
The time can be displayed on the credit indicator by setting this bit to ‘1’. Otherwise 00.00 appears
on the display.
Note: If the time display function is programmed within the electronic validator, then function 0401
will have no effect on the time display.
Display of credit in ‘single vend’
Prior to payout of residual money in ‘single vend’ the existing residual credit is displayed for
approximately 2.5 seconds. Then payout starts.
Delayed reset
After reset, price line remains active for approximately 300 msec.
Cigarette mode
If the value in the validator is ‘0’ it is possible to select a time of 4 seconds, by setting the fourth digit
to ‘1’. However, if a time of > 0 is programmed in the validator, the set value of the validator is valid.
Please note that the setting of function 0401 has higher priority than the validator setting.
Ecological function(only valid for G-26.4000 4-price and 10-price)
If the 4th price line of the changer is connected to the key 'own cup', customers who use their own
cup will get a discount of the amount set as the 4th price.
Page 31
Manual G-26.4000:
Vending Machine Data
Page 31National Rejectors, Inc. GmbH, Germany
Function 05 = Vending Machine Data
ActionKeyDisplay
* Select functionF until05
05 appears
* Display identificationE0501
number1335
* Display audit numberE0502
(with this identification no.)0120
* Display interruptionsE0503
to supply0001
(since last printout)
* Return to base functionF05
* Return to standbyP or +shuts down
Page 32
Manual G-26.4000:
Sales Data
National Rejectors, Inc. GmbH, GermanyPage 32
Function 06 = Sales Data
ActionKeyDisplay
* Select functionF until06
06 apppears
Since last printout:
* Cash to cashboxE0601
90.75
* Cash to tubesE0602
36.45
* Change paid outE0603
15.75
* Actual level left tube (value)E0604
3.45
* Actual level middle tube (value)E0605
12.80
* Actual level right tube (value)E0606
5.20
Since last printout:
* Left tube inventoriesE0607
3.20
* Middle tube inventoriesE0608
11.80
* Right tube inventoriesE0609
5.70
* Credit to GLOBO cardE0610
43.00
* Receipts fromE0611
bill validator30.00
* Erased residual creditE0612
00.19
* Return to base functionF06
* Return to standbyP or +shuts down
Page 33
Manual G-26.4000:
Vend/Sales Data
Page 33National Rejectors, Inc. GmbH, Germany
Function 08 = Vend / Sales Data
ActionKeyDisplay
* Select functionF until08
08 appears
Since installation:
* Total salesE0801
15.50
* Total vendsE0901
10
Since last printout:
* Total salesE0802
* Total vendsE0902
* Display of number ofE0903
free vends2
* Return to base functionF08
if a GLOBO Card system is connected:
* Total sales with GLOBO CardE 4 times0804
* Number of vends withE0904
GLOBO Card 75
3.50
3
55.00
* Discount by GLOBOE0805
Card System12.50
* Return to base functionF08
* Return to standbyFshuts down
Page 34
Manual G-26.4000:
Vend/Sales Data per Price Line
National Rejectors, Inc. GmbH, GermanyPage 34
Function 10 = Vend/Sales Data per Price Line
G-26.4000 Standard
ActionKeyDisplay
* Select functionF until10
10 appears
* Sales per price lineE sequentially1008
to required price09.30
* Vends per price lineE sequentially1108
to required price930
* Return to base functionF10
* Return to standbyP or +shuts down
Page 35
Manual G-26.4000:
Coin and Tube Data
Page 35National Rejectors, Inc. GmbH, Germany
Function 12 = Coin and Tube Data
ActionKeyDisplay
* Select functionF until12
12 appears
* Coins in left tube (quantity)E1201
20
* Coins in middle tube (quantity)E1202
41
* Coins in right tube (quantity)E1203
14
Since last printout:
* Coins accepted in left tubeE1204
* Coins accepted in middle tubeE1205
* Coins accepted in right tubeE1206
* Number of accepted coins :E1207
coin 1305
* Number of accepted coins :E1208
coin 2114
* Number of accepted coins :E1209
coin 398
"
"
165
298
119
* Number of accepted coins :E1214
coin 80
* Return to base functionF12
* Return to standbyP or +shuts down
Page 36
Manual G-26.4000:
Diagnostics
National Rejectors, Inc. GmbH, GermanyPage 36
Function 13 = Diagnostics
ActionKeyDisplay
* Select functionF until13
13 appears
* Select ‘Motors toE1301
service state’
* Execute (see ‘RemedyingE1301
Faults’)—-
* Select ‘Motors toE1302
standby state’
* Execute (see ‘RemedyingE1302
Faults’) ¦¦¦
* Select ‘Take overP1303
data block’
* Access to data blockE1303
Either
* Take over data block+1303
and erase credit00.00
or
* Take over data blockP1303
and retain credit2.50
—2.50
Function 13 continued next page
Page 37
Manual G-26.4000:
Diagnostics
Page 37National Rejectors, Inc. GmbH, Germany
Function 13 = Diagnostics
ActionKeyDisplay
* Select ‘Printout ofP1304
data block’
* PrintoutE1304
¦¦
Connect printer and key ‘PRINT’ on printer
(Example of printout : see below)
* Select ‘Filling of tubesP1305
through validator’ 2.50
* ExecuteE1305
00.00
Existing credit is erased. Now insert coins to fill tubes.
Inserted coins are counted but not evaluated as credit.
* Select ‘Display of lineP1306
conditions’
(G-26.4000 Standard)
* ExecuteE1306
(Example: vend line 1 active)01
* Return to base functionF13
* Return to standbyFshuts down
Example of printout:Reserve Byte
Language of Printout
Machine Type
Cigarette Mode
Lowest Coin Denomination
000130000010
001000500100(left tube) (middle tube) (right tube)
001000500100Coin Denomination Channels
0200050000D11 - 8
00000000FFData Block End
092002200004Software Version
08:09
04.08.1992
Page 38
Manual G-26.4000:
Setting Time and Date
National Rejectors, Inc. GmbH, GermanyPage 38
Function 14 = Setting Time and Date
ActionKeyDisplay
* Select functionF until14
14 appears
* Time and dateE1306
(example:92114830
13.06.92 date
11.48 30 time)
* Select digit to beP sequentially1306
changed92114830
* Change digit+1306
92124830
* Programme digitP1306
92124830
* Return to base functionF14
* Return to standbyFshuts down
Page 39
Manual G-26.4000:
Setting Time and Date
Page 39
Function 14 = Setting Time and Date
daymonth
National Rejectors, Inc. GmbH, Germany
yearhoursminutesseconds
Seconds unit can only be set to zero.
Flashing digit may be changed.
Page 40
Manual G-26.4000:
Single Coin Inhibit
Page 40
National Rejectors, Inc. GmbH, Germany
Function 15 = Single Coin Inhibit
ActionKeyDisplay
* Select functionF until15
15 appears
* Display of settingE15
(see next page)0101000
* Select digit to beP sequentially15
changed0101000
* Change digit+15
0100000
* Programme changeP15
0100000
* Return to base functionF15
* Return to standbyFshuts down
Page 41
Manual G-26.4000:
Single Coin Inhibit
Function 15 = Single Coin Inhibit
Page 41
National Rejectors, Inc. GmbH, Germany
coin 8th channelcoin 2nd channel
0 = coin accepted
1 = coin inhibited
Acceptance of lowest denomination coin cannot be inhibited.
Flashing digit may be changed.
Page 42
Manual G-26.4000:
Printout Format
Page 42
National Rejectors, Inc. GmbH, Germany
Function 16 = Printout Format
ActionKeyDisplay
* Select functionF until16
16 appears
* Display of settingE16
(see next page)0000
* Select digit to beP16
changed0000
* Change digit+16
0001
* Programme changeP16
0001
* Return to base functionF16
* Return to standbyP or +shuts down
Printout:
* Connect printer
* Press PRINT key
In the case of a fault condition, printout is possible even whilst on the internal display four
points are flashing.
Page 43
Manual G-26.4000:
Printout Format
Function 16 = Printout Format
G-26.4000 Standard
Page 43
National Rejectors, Inc. GmbH, Germany
The machine data is always printed
0 = Sales data is printed
1 = Sales data is not printed
0 = Vend/sales data per price line is printed
1 = Vend/sales data per price line is not printed
0 = Time is printed
1 = Time is not printed
0 = Audit data is erased after printout.
1 = Audit data is only erased after initialization with
a data retrieval unit for service (see chapter 19).
This digit cannot be changed by the keyboard. After
readout with a data retrieval unit the digit is set to ‘1’,
whilst it is set to ‘0’ after initialization with a data retrieval
unit for service.
Page 44
Manual G-26.4000:
This section isCASHLESSCARD
printed out onlySALES
if a card system
is operating.0number of vends using GLOBO CARD
Printout Format
MACHINE:111
15.06.1989
AUDIT0: 19
AUDIT1: 1
TOTAL SALES
S208.00
C141
==========
OFF/ON
TO CASHBOXmoney inserted by
C4* = discount by ecological function.
When using the ecological function, the printout includes a star behind C4. The star indicates
that the amount behind the abbreviation represents a discount and not a sale.
Page 45
Manual G-26.4000:
Printout Format
Page 45
Function 16 = Printout Format
G-26.4800 Professional/G-26.4400 SIMPLEX V
National Rejectors, Inc. GmbH, Germany
The machine data is always printed
0 = Sales data is printed
1 = Sales data is not printed
0 =
no influence
1 =
0 = Time is printed
1 = Time is not printed
0 = Audit data is erased after printout.
1 = Audit data is only erased after initialization by a
data retrieval unit for service (see chapter 19).
This digit cannot be changed by the keyboard. After
readout with a data retrieval unit the digit is set to ‘1’,
whilst it is set to ‘0’ after initialization with a data retrieval
unit for service.
Page 46
Manual G-26.4000:
Printout Format
MACHINE:111
15.06.1989
AUDIT0: 19
AUDIT1: 1
TOTAL SALES
S208.00
C141
==========
OFF/ON
TO CASHBOXmoney inserted by
10.00customers to cashbox
0.00receipts from bill validator
TO TUBES
58.10money inserted by customers to tubes
10.00money inserted during tube filling
(operator)
CHANGE
15.60change paid out
11.50money paid out during inventory
0.00erased remaining credit
Page 46
National Rejectors, Inc. GmbH, Germany
TUBE STORE
16.70
SALES
24.30
CYCLES
..........
This section isCASHLESSCARD
printed out onlySALES
if a card system
CYCLES
is operating.0number of vends using GLOBO CARD
DISCOUNT
CASH TO CARDcredit to cards (reloading
==========
20
0number of test sales
0.00turnover using GLOBO CARD
0.00
0.00cards)
Page 47
Manual G-26.4000:
Coins to be inhibited
Page 47
National Rejectors, Inc. GmbH, Germany
Function 17 = Coins to be inhibited
The coins set on this function are inhibited when the ‘tube empty’ condition applies. The ‘tube
empty’ condition is set on function 22.
ActionKeyDisplay
* Select functionF until17
17 appears
* Display settingE17
(see next page)1111000
* Select digit to beP sequentially17
changed1111000
* Change digit+17
1110000
* Programme changeP17
1110000
* Return to base functionF17
* Return to standbyP or +shuts down
Page 48
Manual G-26.4000:
Coins to be inhibited
Page 48
Function 17 = Coins to be inhibited
National Rejectors, Inc. GmbH, Germany
coin 8th channelcoin 2nd channel
Acceptance of lowest denomination coin (1st channel) cannot be inhibited.
Flashing digit may be changed.
Page 49
Manual G-26.4000:
Communication Audit Unit
Page 49
National Rejectors, Inc. GmbH, Germany
Function 18 = Communication with Audit Unit
G-26.4800 Professional and G-26.4400 SIMPLEX V
An audit unit, alreday integrated within the machine control, is able to communicate with a
G-26.4400 SIMPLEX V and G-26.4800 Professional.
Attention: A ‘1’ may only be programmed, if an audit unit is available.
ActionKeyDisplay
* Select functionF until18
18 appears
* Display of settingE18
0
* Change digit+18
1
* Return to base functionP18
* Programme changeP or +shuts down
Note:0 = no audit unit available
1 = connected with audit unit
The fault code 32 appears, if
- audit unit switched off
- vendor cable possibly is defective
- no audit unit connected, however, a ‘1’ is programmed
In the case of a fault, coin acceptance is inhibited and no vends possible.
Page 50
Manual G-26.4000:
Communication Card System
Page 50
National Rejectors, Inc. GmbH, Germany
Function 19 = Communication with a Card System
G-26.4000 Standard and G-26.4800 Professional
Attention: A ‘1’ may only be programmed, if a credit card system is connected to the changer.
When you connect a GLOBO Card system, please refer to the installation instructions for the
GLOBO Card system.
ActionKeyDisplay
* Select functionF until19
19 appears
* Display settingE19
0
* Change setting+19
1
* Return to base functionP19
* Programme new settingP or +shuts down
Note:0 = no card system available
1 = card system connected
The fault code 33 appears, if
- the card system is switched off
- the connecting cable is defective
- no card system is available, however, a ‘1’ is programmed
The display shuts down after approximately 2 minutes. The changer no longer attemps to
communicate with the card system and the fault code is recorded.
The communication with the card system can be reestablished as follows:
* Key Ffault code --33-- appears
* Key F againdisplay shuts down and card system responds again
Page 51
Manual G-26.4000:
Communication Bill Validator
Page 51
National Rejectors, Inc. GmbH, Germany
Function 20 = Communication with a Bill Validator
G-26.4000 Standard and G-26.4800 Professional
Attention: A ‘1’ may only be programmed, if a bill validator is connected to the changer.
ActionKeyDisplay
* Select functionF until20
20 appears
* Display settingE20
0
* Change setting+20
1
* Return to base functionP20
* Programme new settingPshuts down
Note:0 = no bill validator available
1 = a bill validator is connected
The fault code 34 appears, if
- the bill validator is switched off
- the connecting cable is defective
- no bill validator is available, however, a ‘1’ is programmed
The display shuts down after approximately 2 minutes. The changer no longer attemps to
communicate with the bill validator and the fault code is recorded.
Remedying of the fault as described under function 19.
Page 52
Manual G-26.4000:
Communication Talking Module
Page 52
National Rejectors, Inc. GmbH, Germany
Function 21 = Communication with a Talking Module
G-26.4000 Standard and G-26.4800 Professional
Attention: A ‘1’ may only be programmed, if a talking module is connected to the changer.
ActionKeyDisplay
* Select functionF until21
21 appears
* Display settingE21
0
* Change setting+21
1
* Return to base functionP21
* Programme new settingP or +shuts down
Page 53
Manual G-26.4000:
Setting 'Tube empty' condition
Page 53
National Rejectors, Inc. GmbH, Germany
Function 22 = Setting of ‘tube empty’ condition
By using this function it is possible to determine the tube condition which will cause the display
of ‘tube empty’ and to inhibit the acceptance of all coins programmed by function 17.
Please refer also to function 17 'Coins to be inhibited'.
ActionKeyDisplay
* Select functionF until22
22 appears
* Display settingE22
00
* Increase by '1'+22
01
* Return to base functionF22
* Return to standbyP or +shuts down
Possible setting for tube empty condition - see next page.
Page 54
Manual G-26.4000:
Setting 'Tube empty' condition
Page 54
National Rejectors, Inc. GmbH, Germany
On the following table ‘A’ corresponds to the tube with the lowest coin value, whilst ‘C’
corresponds to the tube with the highest coin value.
Note: The factory setting is ‘00’, i.e. the ‘tube empty’ condition is fulfilled when either the tube for
the lowest coin value is empty, or both tubes for the higher coin values are empty.
Value to be set‘Tube empty’ condition
00A empty or
B and C empty
01all tubes empty
02A and B empty
03A and B empty or
A and C empty
04only A empty
05A empty or
B empty
06A empty or
B empty or
C empty
07A and C empty
08A empty or
C empty
09B and C empty
10only B empty
11B empty or
C empty
12only C empty
Page 55
Manual G-26.4000:
Summary Fault Codes
Page 55
National Rejectors, Inc. GmbH, Germany
13. Summary of Fault Codes
DisplayMeaningCategory
01left motor not in final position2
02middle motor not in final position2
03right motor not in final position2
04left and right motors not in final position2
05middle and right motors not in final position2
06left and middle motors not in final position2
07right, middle and left motors not in final position2
13data block of validator defective1
21price data is sent to validator3*
22price data is loaded from validator3*
23data block is loaded3
31no answer from vending machine control1
32no answer from audit unit1
33no answer from credit card system2
34no answer from bill validator2
41file transfer caused by vending machine control3
42file transfer caused by audit unit3
43file transfer caused by credit card system3
44file transfer caused by bill validator3
47file transfer caused by talking module3
48file transfer caused by changer3
51vend operation3
52terminate transaction sent to credit card system3
55data transfer to data retrieval unit3
80vending machine control blocked3 (1)
81free vend3
82function ‘free vend’ and vending machine control blocked 3 (1)
83changer functions blocked by data retrieval unit3
95lowest coin value > 2.501
96lowest coin value = 00.001
* If the transfer of the data block is interrupted, this fault becomes a fault of category 1.
Page 56
Manual G-26.4000:
Summary Fault Codes
Page 56
National Rejectors, Inc. GmbH, Germany
DisplayMeaningCategory
....connecting cable or validator defective1
flash
22 flashesprice data has invalid length1
alternately
with four
points
Category 1 : These faults result in a service case and a shutdown of the vendor.
Category 2 : These faults result in a service case, however, further operation of vendor is possible
with reservation.
Category 3 : Status indication.
Page 57
Manual G-26.4000:
Remedying Faults
Page 57
National Rejectors, Inc. GmbH, Germany
DisplayMeaning
01Left motor not in final position
02Middle motor not in final position
03Right motor not in final position
04Left and right motor not in final position
05Right and middle motor not in final position
06Left and middle motor not in final position
07Left, middle and right motor not in final position
When a motor fault occurs during payout, subsequent payout operations are made with the two other
tubes.
Simultaneously,acceptance of high valued coins is inhibited (function 17, only when ‘Inhibit of high
valued coins’ is selected in function 04). The LED for ‘tube empty’ lights up.
The fault is stored within the error memory and is displayed temporarily.
Pressing any key the last fault is displayed.
Either:
o It is a fault, which can be removed by yourself, for instance a jammed coin
G-26.4000 Standard, G-26.4800 Professional:
* Remove jammed coin
* Key ‘F’
o Fault number appears on display
* Key ‘F’
G-26.4800 BDV-Standard:
* Remove jammed coin
* Execute inventory function by vending machine
The fault is removed.
All tubes pay out coins correctly.
Page 58
Manual G-26.4000:
Remedying Faults
Page 58
National Rejectors, Inc. GmbH, Germany
or:
G-26.4000 Standard, G-26.4800 Professional:
o It is a fault, which cannot be removed immediately. However, the changer should remain in
operation. Therefore, for example, the other tubes have to be filled.
On the display appears:
* Key ‘F’
o Display shuts down
* Fill tubes (see page 18)
* To ensure that no customer gets less change due to the defective motor, initiate one payout
operation (function 01 = inventory) from the tube with the defective motor.
o The fault number appears temporarily on the display.
The changer remains in working condition. When change is given the tube with defective motor is not
operated. The acceptance of high valued coins is inhibited (function 17) and the LED ‘tube empty’
lights up.
G-26.4800 BDV-Standard without keyboard:
* Select function ‘filling of tubes’ on vending machine
control, then fill tubes.
Page 59
Manual G-26.4000:
Remedying Faults
Page 59
DisplayMeaning
13Data block of validator defective
This fault condition can be removed as follows:
* Key ‘F’ 4 times
* Key ‘E
* Key ‘+’ 2 times
* Key ‘F’
* Check setting of functions 2, 3, 4, 15, 16 and 17
National Rejectors, Inc. GmbH, Germany
DisplayMeaning
....Four points are flashing every two seconds.
This means that the connecting cable to the validator or the validator itself is
defective.
The fault condition can be removed as follows:
* Check whether the plug of cable to validator is plugged in correctly
* Check whether the cable strands are fixed and possibly change cable
* Check whether validator is defective and possibly replace validator
Page 60
Manual G-26.4000:
Remedying Faults
Page 60
DisplayMeaning
22 flashes Price data has invalid length
alternately
with four
points
In case the above mentioned numbers are displayed the function of the changer is not influenced,
because these indications are only for information.
Page 61
Manual G-26.4000:
Remedying Faults
Page 61
National Rejectors, Inc. GmbH, Germany
DisplayMeaning
31No answer from vending machine control
32No answer from audit unit
33No answer from card system
34No answer from bill validator
In case these fault codes appear, the coin acceptance is inhibited and no vend is possible.
The reason may be
- the connecting cable is defective
- the peripheral unit is switched off
- no peripheral unit connected, however, a ‘1’ is programmed within the appropriate function
If the fault codes 33 or 34 appear, it is possible to change functions 19 or 20 in spite of a blocked
keyboard. This is necessary, if it is not possible to replace the unit immediately.
After approximately 2 minutes the display shuts down. The changer no longer attemps to communicate
with the card system or the bill validator respectively. The fault code is recorded.
The communication can be reestablished as follows:
* Key Ffault code 33 (34) appears
* Key F againdisplay shuts down and the card system (bill validator) responds
again
Page 62
Manual G-26.4000:
Service Functions
Page 62
National Rejectors, Inc. GmbH, Germany
Function S01 = Display of error list
WhatKeyDisplay
* Select service functionES-01
* Display of error listES-01
04 -03-
04 is the number of fault within the error memory and here
04 corresponds to the number of faults
03 is the code of the fault
* Display prior fault+S-01
03 -01-
03 is the number of fault within the error memory
01 is the code of the fault
* Return to standbyF or Pshuts down
Function S02 - Erasing of error list
WhatKeyDisplay
* Select service functionES-01
* Select function ‘erase’FS-02
* Erase error listES-02
+S-02
ES-02
Page 63
Manual G-26.4000:
Service Functions
Page 63
National Rejectors, Inc. GmbH, Germany
Function S03 = Initialize GLOBO Card system
This function appears only when a GLOBO Card system is connected to the changer. Please refer
to the operating instructions 'GLOBO Card System - Installation'.
Function S04 = Tube counter set to Zero
WhatKeyDisplay
* Service functionES-01
* Select function 'Erase'F until S-04 appearsS-04
* Set tube counter to zeroES-04
+S-04
+S-04
o The tube counter is erased and the display shuts down after approximately one second.
Page 64
Manual G-26.4000:
Maintenance
Page 64
National Rejectors, Inc. GmbH, Germany
16. Maintenance
* Adjustment of
- prices (G-26.4000 Standard)see function 02
- coin acceptancesee operating instructions for KUNEMP G-10.4000/5
- coin denominationsee operating instructions for KUNEMP G-10.4000/5
- token denominationsee function 0303 and operating instructions for
KUNEMP G-10.4000/5
* Filling change tubes through validator
either with key '+'
or by function 1305 ( see item 'Filling Change Tubes', page 18)
* Check and replace if necessary, coin damper in validator
* Clean validator as follows:
o No dismantling necessary
* Open front of validator by turning lock knob to the left
* Clean with damp cloth
o Keep unit away from water
* Shut front of validator by turning lock knob to the right
Page 65
Manual G-26.4000:
Adaptations
Page 65
National Rejectors, Inc. GmbH, Germany
17. Adaptations to different machines
The changer may be modified with interchangeable interface modules, EPROM’s of the control and/
or connecting cables.
Replacing interface module
* Unfasten safety screw
* Remove validator
* Remove screws 1 and 2
* Withdraw module
* Fit new module
* Replace screws 1 and 2
* Refit validator and fasten safety screw
1
Interface modules available
4- and 10-price outputs for 110/120/220/240 Volts A.C.
switchable 110/220 and 120/240 Volts
4- and 10-price outputs for 24 Volts A.C.
4-price outputs for 24 Volts A.C. COCA COLA Standard
G-26.4500 SIMPLEX III
G-26.4400 SIMPLEX V
G-26.4800 Professional
G-26.4800 BDV-Standard
2
Page 66
Manual G-26.4000:
Replacement connecting cable
Page 66
Replacement of connecting cable
* Unfasten safety screw
* Remove cable clamp (two screws) of the interface module
* Remove cable
* Refit and secure new cable
* Pay attention that the cable clamp covers the shield
* Refit validator and secure with safety screw
National Rejectors, Inc. GmbH, Germany
Page 67
Manual G-26.4000:
Bill Validator
Page 67
National Rejectors, Inc. GmbH, Germany
18. Use of a Bill Validator
A converter is used for the interface of different bill validators and changers.
The data transfer between converter and changer is carried out according to a data protocol, which
is similar to the BDV 001 protocol.
The converter enables connection of one of the following types of bill validators:
ARDAC S 2000
Armatic AL 07 *
Coges LMB/1 - LMB/8
Landis & Gyr BSN 40
* The blocking signal of this unit must be high active.
If you would use another type of bill validator, please contact NRI.
For each type of bill validator a special connecting cable is required, which can be ordered at NRI.
Please refer also to the separate operating instructions “Use of Bill Validator in connection with the
changer series G-26.4000”.
Page 68
Manual G-26.4000:
Data Retrieval Unit
Page 68
National Rejectors, Inc. GmbH, Germany
19. Use of a Data Retrieval Unit
By using an infrared adapter the data of the G-26.4000 can be read out (not possible with a G-26.4800
BDV-Standard changer). This adapter transfers the data via an infrared transmission line to a data
retrieval unit.
By using a data retrieval unit the data of the changer can be loaded into a personal computer for further
processing.
There exist three different types of data retrieval unit:
data retrieval unit for service
data retrieval unit for driver
data retrieval unit for management.
After printout of data by a printer the data is erased. However, if prior to printout a data retrieval unit
was used, the data remain stored even after printout.
Only after initialization with a data retrieval unit for service the data is erased after printout.
Please refer to the separate ‘Operating Instructions for Data Retrieval Unit’.
Page 69
Manual G-26.4000:
Talking Module
Page 69
National Rejectors, Inc. GmbH, Germany
20. Use of a NRI Talking Module G-58.0100
Due to its small dimensions the talking module can be used in all kinds of vending machines.
The use of IC’s of state-of-the-art technology enables a natural voice reproduction.
By using a personal computer you can create individual text yourself.
Please refer to the separate ‘Operating Instructions for Talking Module G-58.0100’.
Page 70
Manual G-26.4000:
Drawing Changer
Page 70
National Rejectors, Inc. GmbH, Germany
Return lever
Label
Max. Filling level
Display
Keyboard
Page 71
Manual G-26.4000: Appendix
Changer Series G-26.4000
National Rejectors, Inc. GmbH, Germany
Manual for
- Appendix -
Index
Technical Information 3/93: Latest Programme Version
Technical Information 5/93: Changer Series G-26.4000/6
Page 72
Technical Information 3/93 GB
Changer Series G-26.4000
- latest programme version -
The changer series G-26.4000 are now delivered with the following programme version :
92 00 220-005 (valid for G-26.4000 4-price, 10-price)
92 00 230-005 (valid for G-26.4000 BDV, Professional, Simplex V)
All validators manufactured since 1989, we received for repair, will be retrofitted automatically.
This changer software offers the following functions:
1) Function 19 = Activate communication with the NRI card system GLOBO Card
2) Function 03 = Setting of a subsidy instead of token no. 2
3) Function 04 = Erase remaining credit
4) Function 04 = Activate price table within G-26.4000 Simplex V
5) Function 02 = Setting of prices within G-26.4000 Simplex V
6) Function 10 = Read out of vend/sales data via display (G-26.4000 Professional
and Simplex V)
7) Function 16 = Print out of vend/sales data (G-26.4000 Professional and Simplex V)
8) Function 16 = Print out via printer without print key
Due to additional information the printout of audit data has changed. Please find an example of
the new printout within.
06.93/Bw/VBi
National Rejectors, Inc. GmbH • Zum Fruchthof 6 • D-21614 Buxtehude • Telephone: 04161/70 75 0 • Telefax 04161/70 75 55
Page 73
Manual G-26.4000: Technical Information 3/93
Page 2
National Rejectors, Inc. GmbH, Germany
1) Function 19 = Activate communication with NRI card system GLOBO Card
ActionKeyDisplay
* Select functionF until 19 appears19
* Display settingE19
0000
(See page 3)
* Select digit, if requiredP twice19
0000
* Change setting, if required+19
0010
* Select last digitP 19
0010
* Change this setting+19
0011
* Return to base functionF19
* Return to standbyP or +shuts down
Page 74
Manual G-26.4000: Technical Information 3/93
Page 3
National Rejectors, Inc. GmbH, Germany
Explanation of function 19 = Activate communication with NRI card system GLOBO Card
Note:Only if a card system is connected should a '1' be programmed into any of the four
digits in function 19. These digits have to be 'O' if no card system is connected.
0: no communication with the card system
1: communication with the card system
0: machine control can modify last digit (see below)
1: last digit can only be modified via the changer keyboard
0: changer does not accept discount from card system
1: changer does accept discount from card system
0: no subsidies possible (see below)
1: subsidies possible when using GLOBO card
2nd digit from the right (machine control):
Only in machines working with the protocol BDV 001 the machine controller can sometimes
automatically set the last digit of the display, described above, to '0' after switching on the
machine. If a card system is connected it does not work. However, it is possible to put it into
operation in the following way:
* Set the 2nd digit from the right to '1' ( = last digit can only be modified via the changer
keyboard)
4th digit from the right (subsidies):
In case of a subsidized vend the card user gets his product either free of charge (free vend) or a
part of the vend price is deducted from the card credit.
If a '1' is programmed within the 4th digit from the right of function 19, you can determine within
function 0304 the amount, which shall be deducted from the vend price (see page 4).
The number of subsidized vends per day are determined by the card system. Additionally the card
system contains the information whether the set subsidized amount should be granted or not when
using a GLOBO card.
Page 75
Manual G-26.4000: Technical Information 3/93
Page 4
National Rejectors, Inc. GmbH, Germany
2) Function 03 = Setting of a subsidy instead of token no. 2
When the Globo card system is connected you can programme a subsidy within function 0304 of
the changer.
Note:Prior to programming of a subsidy instead of token 2 make sure that within function
19 the communication with the Globo card system as well as subsidies are activated
(refer to page 2).
ActionKeyDisplay
* Select function 03F until 03 appears03
* Display acceptance limitE0301
00.00
* Select function 03 04P three times0304
00.05
* Increase by lowest coin+ once0304
value00.10
* Increase by multiple of+ continuously0304
lowest coin value00.50
* Rapid increase+ continuously0304
(100 times lowest coin value)05.50
* Return to base functionP03
* Return to standbyP or +shuts down
Page 76
Manual G-26.4000: Technical Information 3/93
3) Function 04 = Erase remaining credit
Page 5
National Rejectors, Inc. GmbH, Germany
If you activate function 'Erase remaining credit', non-payable credit is erased after a
single vend.
Non-payable residual credit means a credit amount for example lower than the lowest coin within
tubes of if tube store is empty.
Within function multi vend the non-payable residual credit is erased after pressing the return
lever.
All erased credit amounts are added by the changer control and printed out under 'erased residual
credit' when printing the audit data.
1 = Erase remaining credit unable to be payed back
(only valid for
G-26.4000 Simplex V)
1 = Reset line 6
0 = Reset linet 8
1 = External reset
0 = Internal reset
1 = Committed to vend
0 = Uncommitted to vend
1 = Single vend
0 = Multi vend
1 = Price setting with Simplex V
1 = Blocking of coins when 'tube empty'
(unchangeable)
1 = 'Exact change' lamp lights up
(unchangeable)
{
G-26.4000 Standard
{
G-26.4000 Standard
* When programming this function please refer to the 'Manual for Changer Series G-26.4000'
function 04.
Page 77
Manual G-26.4000: Technical Information 3/93
Page 6
National Rejectors, Inc. GmbH, Germany
4) Function 04 = Activate price table within G-26.4000 Simplex V
Using this function it is possible to set the prices within the G-26.4000 Simplex V. Thus the audit
data for the G-26.4000 Simplex V now include also the information referring vend/sales per price
line.
Prior to price setting it is necessary to activate the price table within the G-26.4000 Simplex V.
1 = Erase remaining credit unable to be payed back
1 = Reset line 6
0 = Reset line 8
1 = External reset
0 = Internal reset
1 = Committed to vend
0 = Uncommitted to vend
1 = Single vend
0 = Multi vend
1 = Price setting with SIMPLEX V
1 = Blocking of coins when 'tube empty'
(unchangeable)
1 = 'Exact change' lamp lights up
(unchangeable)
{
G-26.4000 Standard
{
G-26.4000 Standard
(Only valid for
G-26.4000 Simplex V)
* When programming this function please refer to the ' Manual for Changer Series G-26.4000'
function 04.
Page 78
Manual G-26.4000: Technical Information 3/93
Page 7
National Rejectors, Inc. GmbH, Germany
5) Function 02 = Setting of prices within G-26.4000 Simplex V
Up to 10 prices can be set.
* Please refer to the 'Manual for Changer Series G-26.4000' function 02 = Pricing of G-26.4000
Standard.
Note:Prior to price setting please activate the price table for G-26.4000 Simplex V within
function 04 ( please refer to page 6).
Up to now prices of Simplex V were programmed within the machine control. Therefore the
communication between G-26.4000 Simplex V and machine is performed in such a way that the
changer expects the price information from the machine control. In order to ensure that the
communication is not interrupted by the price table within Simplex V, please make sure that the
price information within the machine control is adapted.
Price setting within the machine control depends on the lowest coin value in the changer. If the G-
26.4000 Simplex V has a price table, the 1st price within the machine control has to correspond
with the lowest coin value of the changer. All other prices within the machine control have to be a
multiple of the lowest coin value.
Price for product1=1 x lowest coin value
Price for product2=2 x lowest coin value
Price for product3=3 x lowest coin value
etc.
Setting of price information within the machine control is independent from prices within the
changer.
If the vendor transfers 2.50 to the changer, the changer charges the price set within function
0205.
Page 79
Manual G-26.4000: Technical Information 3/93
Page 8
National Rejectors, Inc. GmbH, Germany
6) Function 10 = Read out of vend/sales data via display
(G-26.4000 Professional and Simplex V)
The new changer software records also the vend/sales data of the G-26.4000 Simplex V and
Professional. This data can be read out via the changer display.
* Please refer to the 'Manual for the Changer Series G-26.4000' function 10
'G-26.4000 Standard'.
Note:In order to record the vend/sales data of the G-26.4000 Simplex V please activate the
price table for G-26.4000 Simplex V within function 04 and set prices in function 02
(please refer to page 6).
7) Function 16 = Print out vend/sales data (G-26.4000 Professional and
Simplex V)
By using this function you can determine the printout format. In order to print out the vend/sales
data for the changer Simplex V or Professional please activate the appropriate position within
function 16.
0 = Sales data is printed
1 = Sales data is not printed
0 = Vend/sales data per price line is printed
1 = Vend/sales data per price line is not printed
0 = Time is printed
1 = Time is not printed
0 = Audit data is erased after printout
1 = Audit data is only erased after initialization by a
data retrieval unit for service
0 = Printout via printer with print key
1 = Printout via printer without print key
* Please refer to the 'Manual for Changer Series G-26.4000' function 16.
Page 80
Manual G-26.4000: Technical Information 3/93
Page 9
National Rejectors, Inc. GmbH, Germany
8) Function 16 = Printout via printer without print key
When using this function the changer checks whilst printing whether the printer is connected or
not. In case the printer is not connected, the print procedure is finished immediately. However,
the audit data is not erased. This prevents possible manipulations by pulling off the connecting
cable from the printer early.
If this function is active you can only use a printer without print key, i.e. a printer in which the
print key is shunted and thus active permanently.
0 = Sales data is printed
1 = Sales data is not printed
0 = Vend/sales data per price line is printed
1 = Vend/sales data per price line is not printed
0 = Time is printed
1 = Time is not printed
0 = Audit data is erased after printout
1 = Audit data is only eased after initilization with a
data retrieval unit for service
0 = Printout via printer with print key
1 = Printout via printer without print key
* Please refer to the 'Manual for Changer Series G-26.4000' function 16.
Page 81
Manual G-26.4000: Technical Information 3/93
Annex
Printout of audit data
MACHINE: 2Machine No. 1 - 4 digits
123456Machine No. > 4 digits
19.02.1991
AUDIT0:4
AUDIT1:1
TOTAL SALES
S13.00
C40
CASHLESSCARDOnly if a card system is operating
S7.50sales
C30cyclessince initialisation
C7.50credit
===========
ON/OFF:2
Page 10
National Rejectors, Inc. GmbH, Germany
This section is
printed out only if
a card system is
operating.
TO CASHBOX
9.00money inserted by customers to cashbox
0.00receipts from bill validator
TO TUBES
4.00money inserted by customers to tubes
24.00money inserted during tube filling (operator)
CHANGE
0.00change paid out
0.00money paid out during inventory
0.00erased remaining credit
TUBE STORE
28.00
SALES
13.00
CYCLES
40
0number of test sales
...........
CASHLESSCARD
SALES
7.50turnover using GLOBO Card
CYCLES
30number of vends using GLOBO Card
DISCOUNT
8.20total value of discount and subsides
20number of subsidies and free vends
The changer series G-26.4000/6 includes a CPU-card with extended memory:
G-53.0801 with programme version 92 00 225-001
(valid for G-26.4000 4-price, 10-price)
G-53.0802 with programme version 92 00 240-001
(valid for G-26.4000 BDV, Professional, Simplex V)
G-53.0803 with programme version 92 00 240-001
(valid for G-26.4000 BDV)
The G-26.4000/6 offers you additional functions as follows:
1) Function 06= Display of additional sales data since last printout
2) Function 08/09 = Display of additional vend data
3) Function 07= Display of sales data since installation
4) Function 25= Setting of maximum number of coins per tube
5) Function 22 02 = Setting of 'committed to vend' even when tubes are empty
6) Function 31= Programming of free vend for token
7) Function S-99 = Standard setting
8) Function 0401 = a)Display of price for selected product
b)Working with 'two price lists' (only G-26.4000/6 4-price)
9) Function 02= Price setting for two price lists (only G-26.4000/6 4-price)
10) Function 10/11 = Display vend/sales data per price line for two price lists
(only G-26.4000/6 4-price)
11) Function 24= Setting of period of validity for second price list (only G-26.4000/6 4-price)
Due to the additional information the printout of audit data has changed. Annex I shows you an
example of the new printout. Annex II gives further improvements to the changer.
08.93/VBi
National Rejectors, Inc. GmbH • Zum Fruchthof 6 • D-21614 Buxtehude • Telephone 04161/70 75 0 • Telefax 04161/70 75 55
Page 83
National Rejectors, Inc. GmbH, GermanyPage 2Manual G-26.4000: Technical Information 5/93
1. Function 06 = Display of additional sales data since last printout
* Please refer to function 06 Sales Data of the 'Manual f o r Changer Series
G-26.4000'.
The additional sales data are:
06 13 = Total amount of accepted tokens(since last printout)
06 14 = Erased token amount(since last printout)
2. Function 08/09 = Display of additional vend data
* Please refer to function 08 Vend/Sales Data of the 'Manual for Changer Series
G-26.4000'
The additional vend data are:
08 08 = Total sales with token(since installation)
09 08 = Total vends with token(since installation)
08 09 = Total sales with token(since last printout)
09 09 = Total vends with token(since last printout)
Explanation:
The additional sales and vend data refer to the tokens programmed within the changer. Using function 03
you can programme token values (please refer also to the 'Manual for Changer Series G-26.4000'). The
total value of all accepted tokens is stored within the changer.
If a token is used for paying it is not necessary that the token value corresponds to the price. If the token
value is higher than the price, the difference appears briefly, but then the display shuts down and the
difference remains within the changer. The total of these differences will be shown under 'erased token
amount' on the printout.
If the token value is lower than the price, it is possible to insert coins in order to reach the required amount.
Page 84
Manual G-26.4000: Technical Information 5/93
National Rejectors, Inc. GmbH, GermanyPage 3
3. Function 07 = Display of sales data since installation
ActionKeyDisplay
* Select functionF until07
07 appears
Since installation
* Cash to cashboxE0701
865.20
* Cash to tubesE0702
250.00
* Change paid outE0703
175.60
* Cash to tubesE0704
during filling of tubes315.30
* Money paid outE0705
during inventory113.00
* Credit to cardE0706
78.80
* Receipts ofE0707
bill validator670.00
* Erased residualE0708
credit26.30
* Total amount ofE0709
accepted tokens120.60
* Erased token amountE0710
11.70
* Return to baseF07
function
* StandbyP or +shuts down
Page 85
National Rejectors, Inc. GmbH, GermanyPage 4Manual G-26.4000: Technical Information 5/93
4. Function 25 = Setting of maximum number of coins per tube
ActionKeyDisplay
* Select functionF until25
25 appears
* Display of maximumE2501
number of coins00
in left tube
* Increase by ‘1’+ until desired2501
number appears20
* Erase valueE and +2501
simultaneously until00
00 appears
* Display of maximumP2502
number of coins00
in middle tube
Change as described above
* Display of maximumP2503
number of coins00
in right tube
Change as described above
* Return to baseF25
function
* StandbyP or +shuts down
If the maximum number of coins is reached this is represented by the character 'A' during tube filling.
If no value is programmed (display = 00) the maximum number of coins is limited automatically to 96
pieces.
5. Function 2202 = Committed to vend even when 'tube empty'
Page 86
Manual G-26.4000: Technical Information 5/93
National Rejectors, Inc. GmbH, GermanyPage 5
Up to now the function 'committed to vend' was cancelled as soon as the tube empty condition was
fulfilled. Programming a '1' within function 2202 the feature 'committed to vend' remains valid even when
'tube empty'.
ActionKeyDisplay
* Select functionF until22
22 appears
* Display ofE2201
“tube empty” condition00
* Display of “committed toP2202
vend when tube empty”0
* Change setting+2202
1
* Return to baseF22
function
* StandbyP or +shuts down
'0' = Uncommitted to vend when 'tube empty'
'1’ = Committed to vend when 'tube empty'
6. Function 31 = Programming of free vend for token
Page 87
National Rejectors, Inc. GmbH, GermanyPage 6Manual G-26.4000: Technical Information 5/93
Using function 31 you can programmme free vend for a token to allow certain customers to buy products
free of charge. Possibly programmed token values within function 03 (please refer to 'Manual for Changer
Series G-26.4000') are displayed, but not considered.
ActionKeyDisplay
* Select functionF until31
31 appears
* Display settingE31
000
* Select digit to beP until desired3101
changeddigit flashes000
* Change setting+3101
010
* Return to baseF31
function
* StandbyP or +shuts down
Example:
0 = no free vend with token 1
1 = free vend with token 2
0 = no free vend with token 3
Page 88
Manual G-26.4000: Technical Information 5/93
National Rejectors, Inc. GmbH, GermanyPage 7
7. Function S-99 = Standard setting
Function S-99 allows you to store the present setting of the changer and to execute the standard setting as
mentioned below.
ActionKeyDisplay
* Service functionES-01
* Select standardF until S-99S-99
settingappears
* Execute standardES-99
settingH
+S-99
HH
PS-99
HHH
o The standard setting is executed and
after approximately 1.5 seconds appearsAA
When executing the service function S-99 again the stored changer setting is reestablished and the display
shuts down.
Standard setting:
1. Values from 00.10 up to 01.00 (in decimal steps) are assigned to prices 1 to 10.
2. No acceptance and change limitation (function 03)
6. No printout of vend/sales data per price line (function 16)
7. Coins are inhibited within channels 4, 5, 6, 7, 8 when 'tube empty'
(function 17)
8. No communication with peripheral units (functions 18, 19, 20, 21)
9. 'Tube empty'- condition is set to 0 (function 22)
Page 89
National Rejectors, Inc. GmbH, GermanyPage 8Manual G-26.4000: Technical Information 5/93
8a. Function 0401 = Display of price for selected product
When activating this function the price of the selected product is shown on the external display if
the credit within the changer is not sufficient for the vend. Thus the customer realizes how many
coins he has to insert.
The operator is able to check easily the set vend prices.
1 = Display of price for selected product
1 = Two price lists
(only valid for G-26.4000/6 4-price)
1 = Ecological function
1 = Cigarette mode
1 = Delayed reset
1 = Display of credit in 'single vend'
1 = Display of time
* Please refer to the 'Manual for Changer Series G-26.4000' function 0401.
Page 90
Manual G-26.4000: Technical Information 5/93
National Rejectors, Inc. GmbH, GermanyPage 9
8b.Function 0401 = Working with 'two price lists'
(only G-26.4000/6 4-price)
The G-26.4000/6 4-price changer can process two prices per product. The prices are combined in two
price lists. The switch over from one price list to the other one depends on the period of validity. It is possible
that during a certain period the machine sells the products at a more favourable price. For example the
machine will become more attractive for the night shift.
Please activate 'two price lists' in function 0401.
1 = Display of price for selected product
1 = Two price lists
(only valid for G-26.4000/6 4-price)
1 = Ecological function
1 = Cigarette mode
1 = Delayed reset
1 = Display of credit in 'single vend'
1 = Display of time
* Please refer to the 'Manual for Changer Series G-26.4000' function 0401.
Page 91
National Rejectors, Inc. GmbH, GermanyPage 10Manual G-26.4000: Technical Information 5/93
9. Function 02 = Setting of prices for two price lists
(only G-26.4000/6 4-price)
Note:Please activate 'two price lists' in function 0401 (see page 9), before setting the price
for the second price list.
Within the second price list you can also select free vend (price = 00.00).
ActionKeyDisplay
* Select functionF until02
02 appears
* Display of 1st priceE02
price list II 1 00.10
* Display of 2nd priceP02
price list II 2 00.50
etc., until 4th price is reached
* Display of 1st priceP02
price list IIII 1 00.20
etc.
Assuming the price to be changed is displayed
* Increase by lowest coin+ once02
valueI 1 00.20
* Multiple increase by+ continuously02
lowest coin valueI 1 00.70
* Rapid increase (100 timesE02
lowest coin )I 1 10.70
* Setting lower priceE and + simultaneously02
until 00.00 appears, thenI 1 00.10
set price
Page 92
Manual G-26.4000: Technical Information 5/93
National Rejectors, Inc. GmbH, GermanyPage 11
10.Function 10/11 = Display of vend/sales data per price line
for two price lists (only G-26.4000/6 4-price)
Note:Before you can read the data per price line, please activate 'two price lists' within
function 0401 (see page 9) and execute price setting for two price lists (see page 10).
ActionKeyDisplay
* Select functionF until10
10 appears
* Display: Sales selection 1E10 1
of price list I00.10
* Display: Number ofE11 1
vends with selection 11
of price list I
etc., until price 4 is reached
* Display: Sales selection 1E10 II 1
of price list II00.20
* Display: Number ofE11 II 1
vends with selection 12
of price list II
etc., until price 4 is reached
* Return to baseF10
function
* StandbyP or +shuts down
Page 93
National Rejectors, Inc. GmbH, GermanyPage 12Manual G-26.4000: Technical Information 5/93
Note:If two price lists are used within the changer, the printout also includes the data for
* = Discount by ecolocigal function
(Only G-26.4000 Standard)
Page 96
Manual G-26.4000: Technical Information 5/93
National Rejectors, Inc. GmbH, GermanyPage 15
Annex II
Further improvements to the changer:
-In function 02 of the changer G-26.40000/6 Simplex V now up to 20 prices are available.
-After printout the audit data are not erased immediately, but after a vend, after insertion of a coin or
after pressing the return lever.
-Data referring to the filling level of tubes as well as the coins sorted into tubes are transmitted to the
vending machine control, if the machine control requires this data (only BDV).
-If the condition for 'tube empty' is fulfilled, the coins inhibited by function 17 (Coins to be inhibited)
are enabled, if
- user card is within the GLOBO Card system
- reloading of card is allowed
in order to enable the reloading of the card.