CBT 12XS BATTERY TESTER
A battery diagnosis device for testing all types of 12V batteries
TEST PROCEDURES / OPERATING INSTRUCTIONS
IMPORTANT :
1. For testing 12 volts batteries with capacity range (CCA: A-value on the battery):
DIN : 110~670 CCA
IEC : 130~790 CCA
EN : 185~1125 CCA
CA(MCA) : 240~1440 CA(MCA)
2. Suggested operation range 0 (32) to 50 (122) in ambient temperature.
WARNING :
1. Working in the vicinity of a battery is dangerous. Batteries generate
explosive gases during normal battery operation. For this reason, it is of utmost importance, if you have any doubt, that each time before using your tester, you read these instructions very carefully.
2. To reduce risk of battery explosion, follow these instructions and
those published by the battery manufacturer and manufacturer of any equipment you intend to use in the vicinity of the battery. Observe cautionary markings on these items.
3. Do not expose the tester to rain or snow.
- GB.1-V1 -
PERSONAL SAFETY PRECAUTIONS :
1. Someone should be close to you in order to come to your aid when you work near a battery.
2. Have plenty of fresh water and soap nearby in case battery acid comes into contact with your skin, clothing or eyes.
3. Wear safety glasses and protective clothing.
4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flush out your eye with running cold water for at least ten minutes and get medical attention immediately.
5. NEVER smoke or allow a spark or flame in vicinity of battery or machine.
6. Be extra cautious to reduce risk of dropping a metal tool onto the battery. It could spark or short-circuit the battery or other electrical parts and could cause an explosion.
7. Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead acid battery. It can produce a short circuit current high enough to weld a ring or the like to metal causing a severe burn.
PREPARING TO TEST:
1. Be sure area around battery is well ventilated while battery is being tested.
2. Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
3. Inspect the battery for cracked or broken case or cover. If the battery is damaged, do not use tester.
4. If the battery is not sealed maintenance free, add distilled water in each cell until battery acid reaches level specified by the manufacturer. This helps purge excessive gas from cells. Do not overfill.
5. If necessary to remove battery from vehicle to test, always remove ground terminal connection from battery first. Make sure all accessories in the vehicle are off to ensure you do not cause any arcing.
- GB.2-V1 -
OPERATION & USE :
BATTERY TEST- CBT 12XS
1. Before you test a battery in a vehicle, turn off the ignition and all consumers. Close all the vehicle doors and the trunk lid.
2. Make sure the battery terminals are clean. Wire brush them if necessary. Clamp the black charging load lead to the vehicle negative battery terminal. Clamp the red charging lead to the vehicle positive battery terminal.
3. LED display will light on and show the voltage of the battery
XX.XX on the screen. Press "ENTER" to the next step.
NOTE : If you see HI / Lo / ---- /Blank appear on the screen or
screen flickers, please refer to TROUBLESHOOTING.
4. Please press \ key to select the battery type of
SLI or SEAL :
SLI : Standard SLI flooded batteries.
SEAL : VRLA/GEL/AGM etc sealed /MF batteries.
5. Press "ENTER" to the next step.
6. Please press \ key to select the battery rating of
SAE , din , IEC , En or CA (MCA).
7. Press "ENTER" to the next step.
8. Please press \ key to input the cold test current in A.CCA or CA(MCA)
SAE : 200~1200 CCADIN : 110~670 CCAIEC : 130~790 CCAEN : 185~1125 CCACA(MCA) : 240~1440 CA(MCA)
Press "ENTER" to begin the test.
9. Test the battery within 1 second.
- GB.3-V1 -