Novatel Wireless GSM0108 Users manual

Page 1
Enfora Enabler II-G
Triple/Quad-Band
GSM/GPRS Radio Modems
Integration Guide
Version 1.07
Page 2
Integration Guide Version 1.07
Guide
Version: 1.07
Date: 1/8/2004
Status: Released
Document Control ID: GSM0100PB001
General
All efforts have been made to ensure the accuracy of material provided in this document at the time of release. However, the items described in this document are subject to continuous development and improvement. All specifications are subject to change without notice and does not represent a commitment on the part of Enfora, Inc. Enfora, Inc. will not be responsible for any loss or damages incurred related to the use of information contained in this document.
This product is not intended for use in life support appliances, devices or systems where a malfunction of the product can reasonably be expected to result in personal injury. Enfora, Inc. customers using, integrating, and/or selling this product for use in such applications do so at their own risk and agree to fully indemnify Enfora, Inc. for any damages resulting from illegal use or resale.
Copyright
Complying with all applicable copyright laws is the responsibility of the user. Without limiting the rights under copyright, no part of this document may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopying, recording or otherwise), or for any purpose, without the express written permission of Enfora, Inc.
Enfora may have patents, patent applications, trademarks, copyrights or other intellectual property rights covering subject matter in this document. Except as expressly provided in any written license agreement from Enfora, the furnishing of this document does not give you any license to these patents, trademarks, copyrights or other intellectual property.
©2002, 2003 Enfora, Inc. All rights reserved.
Enabler and Spider are either registered trademarks or trademarks of Enfora, Inc. in the United States.
Page 3
Integration Guide Version 1.07
1.0 Safety Precautions..................................................................................................... 4
1.1 Important Safety Information............................................................................................... 4
2.0 Regulatory Compliance FCC......................................................................... 4
2.1 Integration Considerations and Installation Requirements ................................................. 4
2.2 Disclaimer ........................................................................................................................... 6
3.0 Manual Overview......................................................................................................... 7
3.1 Revision History .................................................................................................................. 7
3.2 Reference Documents ........................................................................................................ 8
4.0 Introduction....................................................................................................................... 10
4.1 Product Overview.............................................................................................................. 10
4.2 Key Features of the GSM/GPRS OEM Module ................................................................ 10
4.3 Providing Multi-Band Operation ........................................................................................ 11
4.4 Wireless Data Application Possibilities ............................................................................. 11
4.5 GSM/GPRS System Overview ......................................................................................... 12
4.6 Summary of the Features for the Enfora Enabler II-G Radio Module .............................. 14
5.0 Technical Specifications.................................................................................... 16
5.1 Enabler II-G Module Block Diagram ................................................................................. 16
5.2 Detailed Product Specifications ........................................................................................ 17
5.3 Operating Power ............................................................................................................... 18
6.0 Physical Interfaces................................................................................................... 20
6.1 Physical Layout .................................................................................................................20
6.2 Enabler II-G Mounting Reference ..................................................................................... 22
6.3 Pin Orientation Reference................................................................................................. 23
6.4 Connectors........................................................................................................................ 24
6.5 I/O Signal Connector on the Enfora Enabler II-G Module ................................................ 25
6.6 Antenna............................................................................................................................. 26
6.7 Control Connector Signal Descriptions and Functions ..................................................... 26
6.8 Subscriber Identity Module (SIM) Carrier ......................................................................... 32
7.0 Modes of Operation................................................................................................ 34
7.1 Enabling the Transmission Modes for the GSM/GPRS Services ..................................... 34
7.2 Voice Communication ....................................................................................................... 34
7.3 Circuit-Switched Data ....................................................................................................... 34
7.4 SMS: Short Message Services ......................................................................................... 35
7.5 SMS Features Supported by the Enfora Enabler II-G Module ......................................... 35
8.0 SIM Operation............................................................................................................... 36
8.1 Provisioning the SIM ......................................................................................................... 36
8.2 GSM Services Supported by the Enfora Enabler II-G Module ......................................... 36
8.3 GPRS Services Supported by the Enfora Enabler II-G Module .......................................36
8.4 Selecting the Modes of Operation .................................................................................... 37
9.0 Software Interface .................................................................................................... 38
9.1 Software Interface ............................................................................................................. 38
9.2 Format for the AT Commands ..........................................................................................38
9.3 Enfora AT Command Set .................................................................................................. 39
9.4 Enfora Packet Application Programming Interface ........................................................... 39
9.5 Enfora Modem Control Library Architecture ..................................................................... 41
Page 4
Integration Guide Version 1.07
10.0 Setup and Initialization .................................................................................... 44
10.1 General Setup................................................................................................................ 44
10.2 GSM/SMS Examples ..................................................................................................... 47
10.3 GPRS Packet Examples................................................................................................ 47
11.0 Integration and Testing ................................................................................... 48
Integrating the Enfora Enabler II-G Module................................................................................ 48
APPENDIX A - Warranty Repair and Return Policy ........................ 50
Reporting and Troubleshooting Problems with the Enfora Enabler II-G Module ....................... 50
APPENDIX B - Regulations and Compliance ......................................... 51
GCF Approval (Formerly FTA) ................................................................................................... 51
Electromagnetic Compatibility (EMC) and Safety Requirements............................................... 51
EMC/Safety Requirements for the USA ..................................................................................... 51
Human Exposure Compliance Statement .................................................................................. 52
Compliance with FCC Regulations............................................................................................. 52
Unintentional Radiators, Part 15................................................................................................. 53
Intentional Radiators, Part 24 ..................................................................................................... 53
Instructions to the Original Equipment Manufacturer (OEM)...................................................... 54
Nationally Recognized Testing Laboratory (NRTL) Approval..................................................... 57
EMC/Safety Requirements for the Countries of the European Union (EU)................................ 58
EMC/Safety Requirements for Other Countries ......................................................................... 58
APPENDIX C - Glossary and Acronyms....................................................... 59
APPENDIX D – Tables And Figures .................................................................. 61
APPENDIX E - Contacting Enfora........................................................................ 62
Page 5
Integration Guide Version 1.07
1.0 Safety Precautions
1.1 Important Safety Information
The following information applies to the devices described in this manual. Always observe all standard and accepted safety precautions and guidelines when handling any electrical device.
Save this manual: it contains important safety information and operating instructions.
Do not expose the Enfora Enabler II-G product to open flames.
Ensure that liquids do not spill into the devices.
Do not attempt to disassemble the product: Doing so will void the warranty. With the exception
of the Subscriber Identification Module (SIM), this product does not contain consumer­serviceable components.
2.0 Regulatory Compliance FCC
2.1 Integration Considerations and Installation Requirements
The Enabler II-G OEM GPRS modem is designed for use in a variety of host units, "enabling" the host platform to perform wireless data communications. However, there are certain criteria relative to integrating the modem into a host platform such as a PC, laptop, handheld or PocketPC, monitor and control unit, etc. that must be considered to ensure continued compliance with FCC compliance requirements.
In order to use the Enabler II-G without additional FCC certification approvals, the installation must meet the following conditions:
For the transmitter to meet the MPE categorical exclusion requirements of 2.1091, the ERP
must be less than 1.5 watts for personnel separation distance of at least 20 cm (7.9 in). Therefore, the maximum antenna gain cannot exceed +3.3dBi. If greater than 1.5 watts exists, then additional testing and FCC approval is required.
If used in a "portable" application such as a handheld device with the antenna less than 20 cm
(7.9 in.) from the human body when the device is operating, then the integrator is responsible for passing additional "as installed" testing:
SAR (Specific Absorption Rate) testing, with results submitted to the FCC for approval prior to selling the integrated unit. If unable to meet SAR requirements, then the host unit must be restricted to "mobile" use (see below).
Unintentional emissions, FCC Part 15; results do not have to be submitted to the FCC unless requested, although the test provides substantiation for required labeling (see below).
GSM0100PB001 Page 4 1.07 - 1/9/04
Page 6
Integration Guide Version 1.07
If used in a "mobile" application where the antenna is normally separated at least 20 cm (7.9 in) from the human body during device operation, then an appropriate warning label must be placed on the host unit adjacent to the antenna. The label should contain a statement such as the following:
WARNING
RF exposure. Keep at least 20 cm
(7.9 in) separation distance from
the antenna and the human body.
Host unit user manuals and other documentation must also include appropriate caution and warning statements and information.
If the FCCID for the modem is not visible when installed in the host platform, then a permanently attached or marked label must be displayed on the host unit referring to the enclosed modem.
For example, the label should contain wording such as
Contains GSM/GPRS modem transmitter module
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
This device must accept any interference received,
including interference that may cause undesired
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
This device must accept any interference received,
including interference that may cause undesired
Substitute MIVGSM0108 for the quad-band modem label.
Any antenna used with the modem must be approved by the FCC or as a Class II Permissive Change (including MPEL or SAR data as applicable). The "professional installation" provision of FCC Part 15.203 does not apply.
The transmitter and antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Violation of this would allow a user to plug another transmitter in to the product and potentially create an RF exposure condition.
The transmitter and antenna must not be collocated
other antenna or transmitter. Failure to observe
this warning could produce an RF exposure
:
FCC ID: MIVGSM0108
operation.
or
Contains FCC ID: MIVGSM0108
operation.
WARNING
or operating in conjunction with any
condition.
GSM0100PB001 Page 5 1.07 - 1/9/04
Page 7
Integration Guide Version 1.07
2.2 Disclaimer
The information and instructions contained within this publication comply with all FCC, GCF, PTCRB, RTTE, IMEI and other applicable codes that are in effect at the time of publication. Enfora disclaims all responsibility for any act or omissions, or for breach of law, code or regulation, including local or state codes, performed by a third party.
Enfora strongly recommends that all installations, hookups, transmissions, etc., be performed by persons who are experienced in the fields of radio frequency technologies. Enfora acknowledges that the installation, setup and transmission guidelines contained within this publication are guidelines, and that each installation may have variables outside of the guidelines contained herein. Said variables must be taken into consideration when installing or using the product, and Enfora shall not be responsible for installations or transmissions that fall outside of the parameters set forth in this publication.
Enfora shall not be liable for consequential or incidental damages, injury to any person or property, anticipated or lost profits, loss of time, or other losses incurred by Customer or any third party in connection with the installation of the Products or Customer's failure to comply with the information and instructions contained herein.
GSM0100PB001 Page 6 1.07 - 1/9/04
Page 8
Integration Guide Version 1.07
3.0 Manual Overview
This document describes the hardware interface of the Enabler II-G GSM/GPRS OEM Modem. The purpose of this document is to define the electrical, mechanical and software interfaces while providing detailed technical information in order to streamline the process of hardware and system integration.
3.1 Revision History
Date Rev Author Description
7/16/03 Draft Matt Glover Initial Draft. 8/27/03 1.00 Matt Glover
9/4/03 1.01 Matt Glover
9/18/03 1.02 Matt Glover
9/22/03 1.03 Matt Glover
11/13/03 1.04 Matt Glover
12/2/03 1.05 Matt Glover
12/11/03 1.06 Matt Glover
1/8/04 1.07 Matt Glover
Modified values in 5.3 Operating Power
Modified drawings in 6.1 Physical Layout
Modified drawing in 6.2 Enabler II-G Mounting Reference
Modified pins 35, 36, 46, and 56 in 6.5.1 I/O Connector Pin
Assignments
Added section 6.7.6 Analog-To-Digital Input
Added section 6.7.7 Digital-To-Analog Output
Added section 6.7.12 Audio Design Note
Added Warranty Information
Modified section 6.7.12 Audio Design Note
Revised serial pin numbers in 6.5.1 I/O Connector Pin Assignments
Changed Enabler II-G description for pin #47 in 6.5.1 I/O Connector
Pin Assignments
Modified section 6.7.12 Audio Design Note
Modified descriptions for pins #20, #26, #29 #31, #36, and # 37 in
6.5.1 I/O Connector Pin Assignments
Removed 5V tolerant reference in 4.2 Key Features of the GSM/GPRS OEM Module and 11.0
Added support for GSM0108 quad-band modem.
Added SIM interface details to pinout chart.
Revised Figure 3 Enabler II-G Package Dimensions (without
integrated SIM carrier) drawing
Revised FCC Compliance Statament
Modified description for pin #24in 6.5.1 I/O Connector Pin
Assignments
Integration and Testing
GSM0100PB001 Page 7 1.07 - 1/9/04
Page 9
Integration Guide Version 1.07
3.2 Reference Documents

Enfora Enabler II-G Product Documentation

Manuals
GSM0102PB001MAN - Enfora GSM/GPRS OEM Module AT Command Set Reference
GSM0102PB002MAN - Enfora GSM-GPRS Family UDP-API Reference
GSM0000PB006MAN - Enfora GSM-GPRS Family Modem Control Library Reference
Application Notes
GSM0000AN001 - Enabler-G PPP Configuration for Windows 98
GSM0000AN002 - Enabler-G PPP Configuration for Windows 2000
GSM0000AN003 - Enabler-G Data Circuit Switched Call Configuration and Use
GSM0000AN004 - Enabler-G SMS Configuration and Use
GSM0000AN005 - Enabler-G Automated Network Connection Configuration and Use
GSM0000AN006 - Enabler-G Module Status Query
GSM0000AN007 - Enabler-G Status Reporting
GSM0000AN008 - Enabler-G PPP Configuration for Windows XP
GSM0000AN009 - Dynamic IP Assignment Support
GSM0000AN010 - Enabler-G PPP Configuration for PocketPC 2002
GSM0000AN011 - PAD Configuration and Use
GSM0000AN012 - Network Transparency Configuration for PAD
GSM0000AN013 - Enabler-G Sleep Mode Configuration and Use
GSM0000AN014 - Anytime PPP API Access
GSM0000AN015 - Event Monitor and Reporting Overview
GSM0000AN016 - How to Send SMS Messages to an E-Mail Address
GSM0000AN017 - SMTP Mail Access via TCP PAD
Technical Notes
GSM0000TN001 - Enabler-G Firmware Upgrade
GSM0000TN002 - Enabler-G PPP Negotiation Sequence
GSM0000TN006 - UDP Wakeup Message Header Decoding
GSM0000TN007 - Enabler-G 3-Wire Serial Interface Requirements
GSM0000TN008 - Enabler Power Supply Requirements
GSM0000TN009 - Server Application Design Considerations for Dynamic IP
White Papers
GSM0000WP001 - Enabler-G Differentiation Features
GSM0000WP002 - Using Enfora UDP API Versus CMUX Protocol

GSM and PCS Device Specifications

GSM 11.10-1 (GSM 850, 900, and 1800 MHz devices)
PCS 11.10 (PCS 1900 MHz devices)
GSM0100PB001 Page 8 1.07 - 1/9/04
Page 10
Integration Guide Version 1.07

US Government

Federal Communications Commission (FCC)

Internet: http://www.fcc.gov/
FCC Rules, Part 24
47 CFR Subpart E--Broadband PCS
47 CFR § 24.52, sections 1.1307(b), 2.1091, and 2.1093
FCC Rules, Part 22 for GSM 850
FCC Rules, Part 15
FCC Rules, Part 2
Subpart J--Equipment Authorization Procedures
Section 2.925

FCC Office of Engineering and Technology (OET)

Internet: http://www.fcc.gov.oet/
Bulletin Number 65 "Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields"
Supplement C "Additional Information for Evaluating Compliance of Mobile and Portable Devices with FCC Limits for Exposure to Radio Frequency Emissions"

Environmental Regulations

National Environmental Policy Act (NEPA) of 1969 (Part 1, Subpart 1)

Mechanical Specifications

ASTM D999
ASTM D775
IEC 68-2-27
Bellcore Gr-63-CORE
ETS 300 019-1-1 Class 1.2
ETS 300 019-1-2 Class 2.1
ETS 300 019-1-3 Class 3.1

RF and EMI Specifications

ETSI Standards
EN 61000-4-6
EN 61000-4-3
GSM 11.10, Section 12.2
EN 55022 Class B
GSM0100PB001 Page 9 1.07 - 1/9/04
Page 11
Integration Guide Version 1.07
4.0 Introduction
4.1 Product Overview
Enfora Enabler II-G GSM/GPRS Radio modem is a compact, wireless OEM module that utilizes the Global System for Mobile Communications (GSM) and GPRS (General Packet Radio Services) international communications standard to provide two-way wireless capabilities via GSM services. The Enfora Enabler II­G module is a fully Type-approved GSM/GPRS device, enabling application-specific, two-way communication and control. The Enfora Enabler II-G module is available in both triple and quad band versions.
The small size of the Enfora Enabler II-G module allows it to be integrated easily into the application and packaging.
4.2 Key Features of the GSM/GPRS OEM Module
The following table summarizes the main features of the Enfora Enabler II-G Radio Module.
Interface
Radio Features
Regulatory Agency approvals
GSM/GPRS Functionality
SIM 3 V Mini-Subscriber Identity Module (SIM) compatible
Data input/output interface 60 position Primary serial port V.24 protocol, 3 V levels Voice Supports three vocoder modes: full-rate (FR), and
enhanced full-rate (EFR), and half-rate (HR) Antenna Interface ultra Miniature Coaxial Interconnect Command protocol Enfora Packet API, GSM AT command set Subscriber Identification Module (SIM) Optional remote SIM Accessible via the 60-pin connector Electrical power 3.3 to 4.5 Vdc Power
Peak currents and average power dissipation
Frequency bands EGSM 900, DCS 1800, and PCS 1900 capability.
GSM/GPRS features supported Provides for all GSM/GPRS authentication,
Mobile-originated and mobile-terminated SMS messages: up to 140 bytes or up to 160 GSM 7-bit ASCII characters.
Reception of Cell Broadcast Message
SMS Receipt acknowledgement
Circuit Switched Data (Transparent & Non-transparent up to 9.6 Kbps)
Voice (EFR, FR, HR)
Supports Unstructured Supplementary Service Data (USSD)
Multi-Slot Class 12 Supported (4Rx/4TX), (5 Slot Max)
PBCCH/PCCCH Supported
Optional 3 V mini-SIM carrier and interface on board
Refer to the Operating Power table in the Technical Specifications for peak currents and average power dissipation for various modes of operation.
Quad band version adds GSM 850 capability.
encryption, and frequency hopping algorithms. GPRS Coding Schemes CS1-CS4 supported. Multi-Slot Class 12 (4RX/4TX, Max 5 Slots).
GCF Type Approval
PTCRB Type Approval
FCC Certification (Part 24)
RTTE
CE (European Community Certification)
IC (Industry Canada) Approval
Table 1 - Enabler II-G Key Features
GSM0100PB001 Page 10 1.07 - 1/9/04
Page 12
Integration Guide Version 1.07
4.3 Providing Multi-Band Operation
The Enfora Enabler II-G module provides multi-band operation, with the operating frequency selectable by AT Command:
The 1900 MHz Enfora Enabler II-G module is available for integration and deployment for use worldwide, with 1900 MHz support primarily in North America and regions where the 1900 MHz Personal Communication Services (PCS) band is allocated. The GSM0108 Quad-Band module also supports GSM 850 for use in North America.
The 900/1800 MHz Enfora Enabler II-G modules are available for deployment in Europe and the rest of the world.
4.4 Wireless Data Application Possibilities
A variety of applications can use the Enfora Enabler II-G module for transmitting and receiving data and voice, such as:
Automated Meter Reading (AMR)
Point of Sale Applications
E-mail and Internet access
Automated Vehicle Location (AVL)
Telematics
Telemetry
Wireless Security
GSM0100PB001 Page 11 1.07 - 1/9/04
Page 13
Integration Guide Version 1.07
4.5 GSM/GPRS System Overview
The Enfora Enabler II-G modules shown in Figure 1 and Figure 2 are designed for easy integration with other components and packaging by leveraging the existing public GSM networks. Compare the Enfora Enabler II-G to systems that require the construction, operation, maintenance, and expense of a private wireless network.
GSM0100PB001 Page 12 1.07 - 1/9/04
Page 14
Integration Guide Version 1.07
Figure 1 Applications Using the Enfora Enabler II-G module in a GSM/GPRS Network
GSM0100PB001 Page 13 1.07 - 1/9/04
Page 15
Integration Guide Version 1.07
4.6 Summary of the Features for the Enfora Enabler II-G Radio Module
The following summarizes the main features of the Enfora Enabler II-G Radio Module.
Mechanical
Dimensions........................................................... 46.1 mm x 30.2 mm x 3.0 mm
Weight .................................................................. < 2 oz.
Packet Data Transfer:
Protocol ................................................................ GPRS Release 97 and 99 (SMG 31)
Coding Schemes.................................................. CS1-CS4
Multi-Slot Capability:
Packet Channel Support ...................................... PBCCH/PCCCH
Circuit Switched Data Transfer:
V110..................................................................... 300 bps/1200 bps/2400 bps/4800 bps/9600 bps/14,400 bps
Non-Transparent .................................................. 300 bps/1200 bps/2400 bps/4800 bps/9600 bps/14,400 bps
Short Message Services:
GSM SMS ............................................................ MO, MT, CB, Text and PDU Modes
GPRS SMS .......................................................... MO, MT, CB, Text and PDU Modes
Voice Capability:
Speech Codec...................................................... EFR, FR, HR
Radio Performance Multi-Band:
GSM0107 Radio Frequencies.............................. 900 (EGSM), 1800 MHz (DCS), or 1900 MHz (PCS)
GSM0108 Radio Frequencies.............................. 850 (GSM), 900 (EGSM), 1800 MHz (DCS), or 1900 MHz
Sensitivity ............................................................. -108 dBm (Typical GPRS CS1)
850 & 900 MHz Transmit Power........................... Class 4 (2 W)
1800 & 1900 MHz Transmit Power....................... Class 1 (1 W)
System Requirements:
Host Interface....................................................... Serial Interface
DC Voltage........................................................... 3.3 to 4.5 Vdc
Application Interface:
Host Protocol........................................................ Status API and AT Commands
Internal Protocols ................................................. UDP stack, TCP/IP stack, PPP, PAD, and CMUX
Physical Interface................................................. Serial 16550 – Default rate 115,200 baud
Audio Interface ..................................................... 1 Headset w/Mic & Bias, 1 Mic w/Bias, 1 Earphone
SIM Interface:
Remote SIM Option.............................................. 3-Volt SIM Capability
(Demonstrated @MS10) ......... MS12 (4RX/4TX) (Max 5 Slots)
(PCS)
GSM0100PB001 Page 14 1.07 - 1/9/04
Page 16
Integration Guide Version 1.07
Environmental:
Operating Temperature ....................................... -20 °C to 60 °C (Fully Spec Compliant)
Storage Temperature ........................................... -40 °C to 85 °C
Humidity ............................................................... 5 to 95% non-condensing
EMC:
Emissions............................................................. FCC Parts 15 & 24, Class B
GSM 11.10, Section 12.2 EN 55022 Class B FCC Part 22 for GSM 850
Susceptibility ........................................................ Per ETSI ETS 300 342-1
EN 61000-4-3 ESD 4 kV contact, 8 kV air discharge EN 61000-4-6
Operating Power:
GSM Operation
GSM 850/900 (1 RX/1 TX, full power) .................. 254 mA average, 1.576 A peak
DCS 1800 (1 RX/1 TX, full power)........................ 212 mA average, 1.136 A peak
PCS 1900 (1 RX/1 TX, full power)........................ 200 mA average, 1.120 A peak
Idle ....................................................................... 3.7 mA
Shutdown ............................................................. 10 uA
GPRS Operation
EGSM 850/900 (4 RX/1 TX, full power)................ 290 mA average, 1.576 A peak
EGSM 850/900 (2 RX/2 TX, full power)................ 422 mA average, 1.576 A peak
DCS 1800 (4 RX/1 TX, full power)........................ 244 mA average, 1.184 A peak
DCS 1800 (2 RX/2 TX, full power)........................ 350 mA average, 1.184 A peak
PCS 1900 (4 RX/1 TX, full power)........................ 232 mA average, 1.120 A peak
PCS 1900 (2 RX/2 TX, full power)........................ 325 mA average, 1.120 A peak
Idle ....................................................................... 3.7 mA
Shutdown ............................................................. 10 uA
Transmit Power
1800/1900 MHz.................................................... GSM Power Class 1 (30 dBm ± 2 dB @ antenna
connection)
850/900 MHz........................................................ GSM Power Class 4 (33 dBm ± 2 dB @ antenna
connection)
Receiver Sensitivity (Typical)
1800/1900 MHz.................................................... -108 dBm, GPRS Coding Scheme 1 (CS1)
850/900 MHz........................................................ -108 dBm, GPRS Coding Scheme 1 (CS1)
GSM0100PB001 Page 15 1.07 - 1/9/04
Page 17
Integration Guide Version 1.07
5.0 Technical Specifications
5.1 Enabler II-G Module Block Diagram
PWR
Audio
SIM
GPIO
Ser. Intfc.
Analog
Baseband/
Power
Mgmt
Digital
Baseband/
CPU
Ana log BB
SRAM/
Flash
Memory
Figure 2 Enabler II-G Module Block Diagram
RF
Interface
VCO
RX Intfc. RF
Tri-band
PA
Antenna
Intfc.
GSM0100PB001 Page 16 1.07 - 1/9/04
Page 18
Integration Guide Version 1.07
5.2 Detailed Product Specifications
Physical Dimensions and Weight
Size (L x W x H)
Weight
Climatic: Operational
Operating temperature -20°C to +60°C
Relative humidity
Solar radiation Not Applicable Air pressure (altitude) 70 kPa to 106 kPa (-400 m to 3000 m)
Climatic: Storage and Transportation
Duration 24 months Ambient temperature
Relative humidity Thermal shock Altitude -400 m to 15,000 m
Mechanical: Operational
Operational vibration, sinusoidal
Operational vibration, random
Mechanical: Storage and Transportation
Transportation vibration, packaged ASTM D999 Drop, packaged ASTM D775 method A, 10 drops Shock, un-packaged 150 m/s Drop, un-packaged 4-inch drop per Bellcore GR-63-CORE
Mechanical: Proposed Standards
Transportation ETSI Standard ETS 300 019-1-2 Class 2.3
Operational ETSI Standard ETS 300 019-1-3 Class 3.1
Storage ETSI Standard ETS 300 019-1-1 Class 1.2 Storage
46.1 mm x 30.2 mm x 3.0 mm
(Less than 2 oz.)
5 - 95%
-40C to +85C 5% to 95%, non condensing (at 40C)
-50C to +23C, +70C to +23C; < 5 min
3.0 mm disp, 2 to 9 Hz; 1 m/s
2
0.1 m
/s3 , 2 to 200 Hz
2
, 9 to 350 Hz
2
, 11 ms, half-sine per IEC 68-2-27
Transportation
Operational
GSM0100PB001 Page 17 1.07 - 1/9/04
Page 19
Integration Guide Version 1.07
Electromagnetic Emissions
Radiated spurious FCC Part 24 / Part 15 Class \ B
GSM 11.10 Section 12.2 EN 55022 Class B
Electromagnetic Immunity (per ETSI ETS 300 342-1)
Radio Frequency (RF) Electromagnetic Field 3 V/m 800 – 1000 MHz; 1 kHz 80%
Electrostatic discharge (ESD) Contact discharge to coupling planes: ±2 kV, ±4 kV
RF common mode 3 V rms (Level 2) 150 kHz – 80 MHz
5.3 Operating Power
The Enfora Enabler II-G module requires an input voltage of 3.3 Vdc to 4.5 Vdc.
5.3.1 GSM Operating Power
Enfora Enabler II-G (@ 3.76 Volts)
GSM 850 EGSM 900
DCS 1800
PCS 1900
5.3.2 GPRS Operating Power
Enfora Enabler II-G (@ 3.76 Volts)
GSM 850 EGSM 900
DCS 1800 GPRS
PCS 1900
Typical Current (mAmps) Peak Current (Amps)
GSM
GSM
GSM
1 TX 1 RX 1 RX Idle
1 TX 1 RX 1 RX Idle
1 TX 1 RX 1 RX Idle
254 mA
3.7 mA
212 mA
3.7 mA
200 mA
3.7 mA
Typical Current (mAmps) Peak Current (Amps)
GPRS
GPRS
1 TX /1RX 2 TX/ 2RX 1 TX/ 2RX 1 TX/ 3RX 1 TX/ 4RX 1 RX Idle
1 TX /1RX 2 TX/ 2RX 1 TX/ 2RX 1 TX/ 3RX 1 TX/ 4RX 1 RX Idle
1 TX /1RX 2 TX/ 2RX 1 TX/ 2RX 1 TX/ 3RX 1 TX/ 4RX 1 RX Idle
240 mA 422 mA 253 mA 270 mA 290 mA
3.7 mA
196 mA 350 mA 207 mA 224 mA 244 mA
3.7 mA
183 mA 325 mA 195 mA 212 mA 232 mA
3.7 mA
EN 61000-4-3
Air discharge to coupling planes: ±2 kV, ±4 kV, ±8 kV
EN 61000-4-6
1.576 A @ 32.75 dBm 104 mA
1.136 A @ 29.25 dBm 104 mA
1.120 A @ 29.5 dBm 104 mA
1.576 A @ 32.75 dBm
1.576 A @ 32.75 dBm
104 mA
1.184 A @ 29.75 dBm
1.184 A @ 29.75 dBm
104 mA
1.120 A @ 29.5 dBm
1.120 A @ 29.5 dBm
104 mA
GSM0100PB001 Page 18 1.07 - 1/9/04
Page 20
Integration Guide Version 1.07
5.4 Transmit Power
Enfora Enabler II-G module Power Class Transmit Power
1900 MHz 1800 MHz
850 MHz 900 MHz
5.5 Receiver Sensitivity
Enfora Enabler II-G module Sensitivity Mode
1900 MHz 1800 MHz 900 MHz 850 MHz
5.6 Radio Power Down
Input has internal pull-up. Low is modem OFF. High (or open) is modem ON.
Radio Power Down Parameter/Conditions MIN TYP MAX UNIT
VIL
VIH
GSM Power Class 1 1-W conducted power maximum (30
GSM Power Class 4
dBm +/- 2 dB), measured at the antenna port
2-W conducted power maximum (33 dBm +/- 2 dB),
measured at the antenna port
-108 dBm (typical)
-108 dBm (typical)
Input Voltage - Low Input Voltage - High
GPRS Coding Scheme 1 (CS1)
GPRS Coding Scheme 1 (CS1)
-0.5 0.9 Vdc
2.0 3.4 Vdc
GSM0100PB001 Page 19 1.07 - 1/9/04
Page 21
Integration Guide Version 1.07
6.0 Physical Interfaces
6.1 Physical Layout
Figure 3 Enabler II-G Package Dimensions (without integrated SIM carrier)
GSM0100PB001 Page 20 1.07 - 1/9/04
Page 22
Integration Guide Version 1.07
Figure 4 Enabler II-G Package Dimensions (with integrated SIM carrier)
Use 46.3 X 30.2 X 3.1 as overall module dimension
Mated 60-pin I/O connector stack height is 2.0 MM
If mounting screw is used, a nylon washer is recommended at board interface. A maximum diameter of
4.00 should be used for all fastening hardware.
Antenna direct connect solder pad is 1.02 mm wide X 2.54 mm high.
Antenna ground pads are 2.03 mm wide X 2.54 mm high.
GSM0100PB001 Page 21 1.07 - 1/9/04
Page 23
Integration Guide Version 1.07
6.2 Enabler II-G Mounting Reference
Figure 5 Provides Enabler II-G vertical mounting information.
Figure 5 Vertical Enabler II-G Mounting
The Enabler II-G provides mounting tabs that can be soldered to a PCB. These tabs provide circuit grounding for the module and their use is recommended. Figure 6 provides mounting tab reference for PCB integration.
Figure 6 Enabler II-G Mounting Tabs
GSM0100PB001 Page 22 1.07 - 1/9/04
Page 24
Integration Guide Version 1.07
6.3 Pin Orientation Reference
59 57 55 53 51 49 60 58 56 54 52 50
7 45 43 41 39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1 8 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2
Figure 7 Pin Orientation
GSM0100PB001 Page 23 1.07 - 1/9/04
Page 25
Integration Guide Version 1.07
6.4 Connectors

6.4.1 Enabler II-G I/O Control Connector

The connector used to interface to the host is a 60-pin, Pitch Plug; Molex part number 53729-0604.
6.4.2 PCB Integration I/O Control Connector
The mating connector for a board mount application is a 60-pin, .50MM (.020") Pitch Receptacle; Molex part number 52974-0604 or 52974-0608.
SMT, Dual Row, Vertical Stacking: .50MM (.020")
SMT, Dual Row, Vertical Stacking:
Figure 8

PCB Integration I/O Control Connector

GSM0100PB001 Page 24 1.07 - 1/9/04
Page 26
Integration Guide Version 1.07
6.5 I/O Signal Connector on the Enfora Enabler II-G Module
The Enfora Enabler II-G module communicates with the carrier board of the application via the 60-pin I/O signal connector. The following table describes the pin assignments for the connector, sorted by pin number.

6.5.1 I/O Connector Pin Assignments

The following table shows the pin assignments for the input/output connector. The pin assignments are shown in order of functionality.
PIN
# 1 Power Input P Batt/Vcc Electrical power input to Enabler II-G module.
2 Power Input P Batt/Vcc Electrical power input to Enabler II-G module.
3 Power Input P Batt/Vcc Electrical power input to Enabler II-G module.
4 Power Input P Batt/Vcc Electrical power input to Enabler II-G module.
5 Power Input P Batt/Vcc Electrical power input to Enabler II-G module.
6 Power Input P Batt/Vcc Electrical power input to Enabler II-G module.
7 Ground R GND Electrical power return for digital and analog grounds.
8 Ground R GND Electrical power return for digital and analog grounds.
9 Handset Speaker (-) O INTERNAL_SPK(-) Handset speaker output (negative). 10 Power Input P Batt/Vcc Electrical power input to Enabler II-G module. 11 Ground R GND Electrical power return for digital and analog grounds. 12 Power Input P Batt/Vcc Electrical power input to Enabler II-G module. 13 Handset Speaker (+) O INTERNAL_SPK(+) Handset speaker output (positive). 14 GPIO-1 I/O GPIO-1 General-purpose Input/Output. 15 Ground R GND Electrical power return for digital and analog grounds. 16 Ground R GND Electrical power return for digital and analog grounds. 17 Microphone Bias O VMIC Microphone Bias. 18 GPIO-5 I/O GPIO-5 General-purpose Input/Output. 19 Ground R GND Electrical power return for digital and analog grounds. 20 Reserved Reserved for future use. 21 Handset Microphone (-) I INT_MIC(-) Handset microphone input (negative). 22 Radio Power/Reset I RADIO_PWR/RST Radio power/reset. 23 Ground R GND Electrical power return for digital and analog grounds. 24 Power Control Signal I PWR_CTL_SIGNAL Power Control Signal. 25 Handset Microphone (+) I INT_MIC(+) Handset microphone input (positive). 26 Reserved Reserved for future use. 27 GPIO-3 I/O GPIO-3 General-purpose Input/Output. 28 GPIO-2 I/O GPIO-2 General-purpose Input/Output. 29 Reserved Reserved for future use. 30 GPIO-4 I/O GPIO-4 GPIO/MCSI TX. 31 Reserved Reserved for future use. 32 GPIO-6 I/O GPIO-6 GPIO/MCSI RX. 33 Ground R GND Electrical power return for digital and analog grounds. 34 GPIO-7 I/O GPIO-7 GPIO/MCSI CLK. 35 DAC O DAC Digital-to-Analog Output.
36 Reserved Reserved for future use. 37 Reserved Reserved for future use. 38 Headset Earphone (+) O HEADSET_SPK(+) Headset Earphone (positive). 39 GPIO-8 I/O GPIO-8 GPIO/MCSI FSNC. 40 Headset Microphone (-) I HEADSET_MIC(-) Headset Microphone (negative). 41 Ground 5 R GND Electrical power return for digital and analog grounds. 42 Headset Microphone (+) I HEADSET_MIC(+) Headset Microphone (positive). 43 Serial Receive Data 2 O RXD_RADIO Serial Data to Host. 44 Ground R GND Electrical power return for digital and analog grounds. 45 Data Set Ready 6 O DSR_RADIO DSR Signal to Host. 46 ADC2 I ADC2 Analog-to-Digital Converter Input 2.
47 Data Carrier Detect 1 O DCD DCD Signal. 48 SIM Clock O SIM_CLK SIM Clock. 49 Ring Indicator 9 O RI RING Indicator.
FUNCTION Serial
Pin
I/O ENABLER II-G Description/Comments
0.3 to 2.0 Vdc minimum range
0 – 1.75 Vdc range. 1.709 mV resolution. 10 bit.
GSM0100PB001 Page 25 1.07 - 1/9/04
Page 27
Integration Guide Version 1.07
50 Ground R GND Electrical power return for digital and analog grounds. 51 Serial Transmit Data 3 I TXD_RADIO Serial Data from Host. 52 SIM I/O I/O SIM_IO SIM I/O Data. 53 Request To Send 7 I RTS_RADIO RTS Signal from Host. 54 SIM Reset O SIM_RST SIM Reset. 55 Clear To Send 8 O CTS_Radio CTS Signal to Host. 56 ADC1 I ADC1 Analog-to-Digital Converter Input 1.
57 Data Terminal Ready 4 I DTR_RADIO DTR Signal to Host. 58 SIM Power O SIM_VCC SIM Power. 59 Ground R GND Electrical power return for digital and analog grounds. 60 Ground R GND Electrical power return for digital and analog grounds.
Table 2 - Enabler II-G Pin Assignments
I=Input into Enabler; O=Output from Enabler; P=Power Input to Enabler; R=Power Return from Enabler; I/O=Input/Output into/from Enabler
Reserved for future use
NO CONNECT if on-board SIM holder is used
6.6 Antenna
A custom tri-band antenna can be attached via the on-board connector or soldered directly to the modem. Each antenna direct connect solder pad is 1.02 x 2.54 MM.

6.6.1 Antenna Solder Pads

Pads are provided to solder a cable or antenna directly to the Enabler II-G board.
6.6.2 RF Connector
The Enabler II-G utilizes an ultra Miniature Coaxial Interconnect from Sunridge (MCB-ST-00T) as the on­board antenna connector. A compatible mating connector is the Sunridge MCB2-xx-xx-xxx-x series component. The cable assembly is made to order. Maximum stack height of cable connector and PCB connector is 2.0 mm.
6.7 Control Connector Signal Descriptions and Functions
6.7.1 Input Power
The Enfora Enabler II-G module uses a single voltage source of VCC=+3.3V to 4.5V. (exact values of the uplink currents are shown in Tables5.3.1 GSM Operating Power and 5.3.2 GPRS Operating Power). The
lines (pins 1 to 6) should be connected on the application board. The uplink burst will cause strong
V
CC
ripple on the voltage lines and should be effectively filtered. It is recommended that 1000 to 2000 uF of capacitance be placed as close to the modem I/O connector as possible.
It should be noted that the input voltage level should not drop below the minimum voltage rating under any circumstances, especially during the uplink burst period.
0 – 1.75 Vdc range. 1.709 mV resolution. 10 bit.
GSM0100PB001 Page 26 1.07 - 1/9/04
Page 28
Integration Guide Version 1.07

6.7.2 Ring Indicate

The Enabler II-G module is capable of using the Ring line to discern the type of incoming call. The indicator can be monitored via a hardware line available on the 60 pin I/O signal connector. The Ring Indicator pin is #49.
The function of the Ring line depends on the type of the call received.
When the module is receiving a voice call, the Ring line goes low for 1 second and high for another 2 seconds. Every 3 seconds the ring string is generated and sent over the Receive (Data Out) (Rx) line. If there is a call in progress and call waiting is activated for a connected handset or hands free device, the Ring pin switches to ground in order to generate acoustic signals that indicate the waiting call.
Ring
When a Fax or data call is received, Ring goes low and will remain low. Every 3 seconds a ring string is generated and sent over the Receive (Data Out) (Rx) line.
Ring
An incoming SMS can be indicated by an Unsolicited Result Code (URC) which causes the Ring line to go low for 1 second only. Using the AT+CNMI command, the Enabler II-G can be configured to send or not to send URCs upon the receipt of SMS. See Enfora GSM/GPRS OEM Module AT Command Set Reference
- GSM0102PB001MAN.
Ring
1 second
RING String RING String
RING String
1 second
URC
2 seconds
3 seconds
1 second
RING String
2 seconds
3 seconds
RING String
Figure 9 Ring Indicate Timing
GSM0100PB001 Page 27 1.07 - 1/9/04
Page 29
Integration Guide Version 1.07

6.7.3 Radio Power/Reset

Pull low for radio off. Use large value pull-up resistor (up to 1 M) to Vcc (Power Input/Batt).
PARAMETER PARAMETER / CONDITIONS MIN TYP MAX UNIT V
IL
V
IH
Input Voltage – Low 0 0.3
Input Voltage – High 0.7
Vcc
Vcc
Vbat Vdc
Vdc

6.7.4 Serial Interface (9 Pin I/F) (See table in section 6.5.1 I/O Connector Pin Assignments)

The modem provides a standard 16550 UART serial interface to the host. The data interface operates at CMOS level. The Enabler II-G is designed to be used like a DCE device. RxData is the serial data from the modem to the host. TxData is the serial data from the host to the modem.
Enabler II-G
UART
Host
Tx
Rx
DCD
RTS
DSR
DTR
CTS
RING
Figure 10 Enabler II-G Serial Interface
This data may contain 7 or 8 data bits, 1 or 2 stop bits, even/odd/no parity bits. The baud rate may be adjusted to 75, 150, 300, 1200, 2400, 4800, 9600,19200, 38400, 57600, or 115200 bits per second.
Default settings are 8 data, 1 stop, no parity, and 115200 baud. DTR may be used to force the modem into AT command mode from online data mode. RTS and CTS may be used for hardware handshaking. DSR is always active (connected to ground) while the modem is on. RING may be used to alert the host to a variety of incoming calls.
For a minimal implementation, connect RxData and TxData to the COM port serial data lines, connect DTR and RTS to GND.
GSM0100PB001 Page 28 1.07 - 1/9/04
Page 30
Integration Guide Version 1.07

6.7.5 General Purpose Input/Output Interface (GPIO)

Eight general-purpose signals (GPIO 0,2) are provided. Each of these signals may be selected as inputs or outputs. They may be used independently as a user-specified function, or may be used to provide modem control and status signals. Several examples of modem control signals are: power shutdown command, register/deregister on network command, and transmitter disable. Several examples of modem status signals are: registration status and ready-for-power-down status to be used with power shutdown command signal.
I/O Lines Parameter/Conditions MIN TYP MAX UNIT V
IL
V
IH
V
OL
V
OH
IIL / IIH IOL / IOH
Input Voltage – Low Input Voltage – High Output Voltage – Low Output Voltage – High Input Leakage Current Rated Output Current
6.7.6 Analog-To-Digital Input

Analog-To-Digital Input Parameter/Conditions MIN TYP MAX UNIT ADC ADC V

ADC
Z
ADC
BRES
REF
ADC Binary Resolution ADC Reference Voltage ADC Range ADC Input Impedance
6.7.7 Digital-To-Analog Output

Digital-To-Analog Output Parameter/Conditions MIN TYP MAX UNIT DAC TS V

OMAX
BRES
DAC Binary Resolution Settling Time Output Voltage with Code Maximum
V
OMIN
Output Voltage with Code Minimum
-0.5 0.9 Vdc
2.0 3.4 Vdc
0.64 Vdc
2.4 3.0 Vdc
-1 1 µ
2 mA
µA
µµ
10 Bits
1.75 Vdc 0 1.75 Vdc 100 kΩΩΩ
10 Bits 10 µµµµS
2.0 2.2 2.4 Vdc
0.18 0.24 0.3 Vdc
GSM0100PB001 Page 29 1.07 - 1/9/04
Page 31
Integration Guide Version 1.07

6.7.8 Handset Microphone Input

Parameter Conditions MIN TYP MAX UNIT Maximum Input Range – Mic(+) to Mic(-)
Nominal Ref. Level – Mic(+) to Mic(-) Differential Input Resistance – Mic(+) to Mic(-) Microphone Pre-Amplifier Gain 25.6 dB Bias Voltage on Mic(+) Mic Bias Current Capability 0 0.5 mA

6.7.9 Handset Speaker Output

Parameter Conditions MIN TYP MAX UNIT Maximum Swing – Ear(+) to Ear(-) Maximum Capacitive Load – Ear(+) to Ear(-) Amplifier Gain 1 dB Amplifier State in Power Down
Enfora recommends an external audio amplifier for loads of less than 16 or if volume is inadequate.
6.7.10 Headset Microphone Input
Inputs 3 dBm0 (Max. digital sample amplitude when PGA gain set to 0 dB)
2.0 or 2.5 V
RL = 32 & 5% distortion
High Z
-10 dBm0
2.0 2.5 Vdc
1.2 1.5 Vpp
100 pF
Parameter Conditions MIN TYP MAX UNIT Maximum Input Range – Mic(+) to Mic(-)
Nominal Ref. Level – Mic(+) to Mic(-) Differential Input Resistance – Mic(+) to Mic(-) Microphone Pre-Amplifier Gain 25.6 dB Bias Voltage on Mic(+) Mic Bias Current Capability 0 0.5 mA
6.7.11 Headset Speaker Output
Parameter Conditions MIN TYP MAX UNIT Maximum Swing – HS Spkr (+) to (-) Maximum Capacitive Load – HS Spkr (+) to (-) Amplifier Gain -7 -5 dB Amplifier State in Power Down
The headset speaker output is a single ended output. Enfora recommends an external audio amplifier for loads of less than 32 Ω or if volume is inadequate.
Inputs 3 dBm0 (Max. digital sample amplitude when PGA gain set to 0 dB)
2.0 or 2.5 V
RL = 32 & 5% distortion
High Z
-10 dBm0
2.0 2.5 Vdc
1.6 1.96 Vpp
100 pF
32.5 mVrms
100 kΩΩΩ
32.5 mVrms
100 kΩΩΩ
GSM0100PB001 Page 30 1.07 - 1/9/04
Page 32
Integration Guide Version 1.07
6.7.12 Audio Design Note
Speaker and microphone PCB traces should be run in pairs and buried between two ground planes for best results. The following figure provides a sample circuit design for connection of Mic and Speaker pins.
Figure 11 Audio Reference
(Please note that this schematic can be zoomed to read the detail)
GSM0100PB001 Page 31 1.07 - 1/9/04
Page 33
Integration Guide Version 1.07
6.8 Subscriber Identity Module (SIM) Carrier
The SIM, an integral part of any GSM terminal device, is a “smart card” that is programmed with subscriber information:
The user information consists of an International Mobile Subscriber Identity (IMSI) number, which is registered with the GSM provider, and an encryption Ki (pronounced "key"). This information consists of a microprocessor and memory installed on a plastic card.
Note: The SIM is not provided with the Enfora Enabler II-G module. The SIM must be obtained from the GSM service provider and must be provisioned by the operator for data and/or voice. Always take care to protect the SIM: the GSM terminal will not operate without the SIM installed.
The SIM provides the IMSI for authentication. To gain access to the GSM network, the network must recognize the IMSI number, and the terminal must be able to properly decrypt the data sent by the network. The SIM also serves as a buffer for SMS messages, storing the message for transmission until a radio link is available and buffering received messages until retrieved.

6.8.1 SIM Integration for the Enfora Enabler II-G Module

The Enabler II-G default configuration does not include an on-board SIM carrier. Enfora provides a separate product SKU for the Enabler II-G module with the integrated SIM carrier.
GSM0100PB001 Page 32 1.07 - 1/9/04
Page 34
Integration Guide Version 1.07

6.8.2 Using a Remote SIM with the Enfora Enabler II-G Module

The Enabler II-G default configuration does not include an on-board SIM carrier. If the module is going to be integrated using a remote SIM, the following guidelines are provided:
To utilize a remote SIM, the integrator must provide a suitable SIM connector on the Application.
The maximum distance from the Enabler II-G to the remote SIM connector must not exceed 25.4
cm (10 inches).
Remote SIM Power Parameter/Conditions MIN TYP MAX UNIT V
DD
IDD
Remote SIM Line Description SIM_VDD SIM_RST SIM_CLK SIM_I/O
Remote SIM power supply Remote SIM reset Remote SIM clock Remote SIM serial data interface
Enabler II-G
SIM Interface
Remote SIM Supply Voltage 3 V Mode Remote SIM Supply Current – 3V Modes
<25.4 cm (10 in)
SIM_VDD
SIM_RST
SIM_CLK
SIM_I/O
2.7 3.3 Vdc 10 mA
Remote SIM
Figure 12 Remote SIM Interface
ESD Protection
15 kV Air Discharge
8 kV Contact Discharge
6.8.2.1 Remote SIM Component Information
A SIM carrier compatible for use on the Enabler II-G is a JAE Plug-In SIM Card carrier with hinge; JAE part number SF7W006S1BE1000
. JAE Plug-in SIM Card with hinge cover SF7 Series.
GSM0100PB001 Page 33 1.07 - 1/9/04
Page 35
Integration Guide Version 1.07
7.0 Modes of Operation
GSM/GPRS supports many optional services and modes. The Enfora Enabler II-G module supports the following GSM/GPRS services:

Circuit-switched data

Short-Message Services (SMS)
Class B GPRS Functionality

Voice communication

7.1 Enabling the Transmission Modes for the GSM/GPRS Services
Each of the GSM/GPRS services has two modes that can be enabled separately:
Mobile-originated (MO): allows the making of a service request (such as, making a telephone call or sending an SMS)
Mobile-terminated (MT): allows receiving a service request (such as receiving a telephone call or an SMS)
Note: Contact your local GSM operator to ensure that the services and modes have been provisioned for the SIM.
7.2 Voice Communication
The Enfora Enabler II-G module has full voice capabilities, provided the necessary connections have been made for the speaker and microphone pins on the 60-pin I/O connector. The Enfora Enabler-G AT Command Set Reference - GSM0102PB001MAN has the entire list of commands that can be used to control the voice functionality. The quick start guide in this manual provides a basic command set that can be used to initialize and test the voice functionality.
The Enfora Enabler II-G module supports three vocoder compression algorithms for voice communication: Full-Rate, Enhanced Full-Rate (EFR), and Half-rate (HR).
7.3 Circuit-Switched Data
In this mode, the Enfora Enabler II-G module supports both of the connection modes of transmission that are provided by GSM:
Non-Transparent mode delivers a constantly low error rate but with a non-guaranteed throughput or delay. The Non-Transparent service provides a performance that is closest to using a modem over a fixed Public Switched Telephone Network (PSTN) line.
Note: All GSM service providers may not support Transparent mode. In those cases, the Enfora Enabler II­G module can be configured to switch automatically to Non-Transparent mode. This capability depends on the settings in the AT+CBST command.
GSM0100PB001 Page 34 1.07 - 1/9/04
Page 36
Integration Guide Version 1.07
7.4 SMS: Short Message Services
Short Message Services (SMS) is a feature-rich GSM service. The Enfora Enabler II-G module can perform the following tasks:
Sending and receiving binary messages of up to 160 characters (7-bit characters)
Sending and receiving text messages of up to 140 bytes (8-bit data)
Submitting a SMS Protocol Data Unit (PDU) to a SMSC (Short Message Service Center) and storing a
copy of the PDU until either a report arrives from the network or a timer expires
Receiving a SMS PDU from a SMSC
Returning a delivery report to the network for a previously received message
Receiving a report from the network
Notifying the network when the module has sufficient memory capacity available to receive one or more
SMS messages (after the module had previously rejected a message because its memory capacity was exceeded)
7.5 SMS Features Supported by the Enfora Enabler II-G Module
The following list details the key characteristics and assumptions regarding the form of SMS supported in the Enfora Enabler II-G module.
Supports both mobile-originated (MO) and mobile-terminated (MT) SMS
Delivers the message to a telephone
Supports 8-bit data
Supports Message Class 1 & Class 2
Provides a status report indicator
Allows the definition of a validity period
Provides the Service Center Time Stamp
Alerts the SMSC
USSD
GSM0100PB001 Page 35 1.07 - 1/9/04
Page 37
Integration Guide Version 1.07
8.0 SIM Operation
8.1 Provisioning the SIM
The SIM can support optional features or services. Most operators typically configure the SIM to send/receive voice calls and to receive SMS; however, some may require an additional tariff to enable the SIM to send SMS. The transmission of circuit switched and GPRS data are also additional services that may be required to allow the service:
Mobile-originated (MO): allows making a service request (such as, making a call or sending an SMS)
Mobile-terminated (MT): allows receiving a service request (such as, receiving a phone call or an SMS)
It is imperative for the Enfora Enabler II-G module that the SIM be configured for the optional services that are required for the application.
8.2 GSM Services Supported by the Enfora Enabler II-G Module
The Enfora Enabler II-G module supports four GSM services (modes of operation) that must be enabled by the operator:
Voice calls (MO and MT): requires a telephone number
SMS (MO and MT): uses the telephone number for Voice
Circuit-switched data calls (MO and MT): requires a telephone number
The GSM SIM can have multiple telephone numbers.
8.3 GPRS Services Supported by the Enfora Enabler II-G Module
The Enfora Enabler II-G module supports the following GPRS (modes of operation) that must be enabled by the operator:
GPRS Packet Connectivity (MO and MT) with Both Dynamic and Static IP option
GPRS SMS (MO and MT): uses the IP (Dynamic or Static) set by the operator
Multiple APN Setting
Quality of Service Options
Multi-slot 12 Class of Service (Requested vs Granted) (Demonstrated @ MS10)
GSM0100PB001 Page 36 1.07 - 1/9/04
Page 38
Integration Guide Version 1.07
8.4 Selecting the Modes of Operation
When provisioning the SIM for the Enfora Enabler II-G module, enable the following modes of operation:
Voice calls: configure the SIM for both MO and MT service (to send and receive)
SMS: configure the SIM either for MT alone (to receive) or for both MO and MT (to send and receive)
Circuit Switched Data: configure the SIM either for MO alone (to send) or for both MO and MT (to send
and receive)
Voice SMS CS Data GPRS Function MO/MT MT MO Voice calls, receive SMS, make data calls MO/MT MO/MT MO Voice calls, receive / send SMS, make data calls MO/MT MO/MT MO/MT Voice calls, receive / send SMS, make / receive data calls
(requires an additional data telephone number)
GSM0100PB001 Page 37 1.07 - 1/9/04
Page 39
Integration Guide Version 1.07
9.0 Software Interface
9.1 Software Interface
The application sends commands to the Enfora Enabler II-G module via the 60-pin I/O signal connector. These commands use the Enfora AT Command Set and/or Enfora’s Packet API.
The Enfora Enabler II-G module operates in one of the following modes:
Command mode: Used for configuring the Enfora Enabler II-G module, for interrogating the GSM network, and for placing and receiving calls. It uses the AT command set via the serial port for communication.
On-line mode: Used after a circuit-switched data call has been established. Data is passed between the Enfora Enabler II-G module and the controlling application without command interpretation. The only AT command that is interpreted in On-line mode is the +++ command. (This command places the Enfora Enabler II-G module in Command mode but does not terminate the circuit-switched data call.)
IP Packet /API Mode: Used to read/write modem parameters, interrogate network information, and place and receive calls in real-time, multi-tasking mode. The Packet API mode is facilitated over a PPP connection and the packets can be constructed according to the information provided in the Enfora
GSM-GPRS Family UDP-API Reference GSM0102PB002MAN. Enfora GSM-GPRS Family Modem Control Library Reference GSM0000PB006MAN provides detail of the UDP Modem Control Library that
has three levels: port , messaging, and modem libraries. Each of the three levels contains one or more libraries. For example, the port libraries layer has UDP PPP Port, UDP Socket Port, and COM Port libraries. All libraries are provided as a part of the Enfora Enabler II-G Integration Toolkit.
The AT command driver of the Enfora Enabler II-G module never exits the Command state, that is, it never enters the On-line mode. Although the host interface may not be able to access the AT command interpreter, it is always running and is available via the API Mode over a PPP connection and/or via the RF interface.
In the Command state, characters that are received from the Customer Premise Equipment (CPE) are treated as AT commands by the Enfora Enabler II-G module.
In response to the commands received from the CPE, the Enfora Enabler II-G module sends characters (AT commands) to the CPE.
Various events can also trigger the Enfora Enabler II-G module to send characters (AT commands) to the CPE.
9.2 Format for the AT Commands
The general format of the command line is: <prefix> <command> <CR>
<prefix> <command> <CR>
The prefix AT obtains synchronization, identifies the character parameters, and indicates that a command may be in the following characters.
AT commands are not case sensitive: use either capital letters or lower-case letters for the AT command.
Note: Some AT Command parameter values ARE case sensitive and are documented in the Enfora Enabler-G AT Command Set Reference - GSM0102PB001MAN.
AT See AT Command Manual 0X0D
GSM0100PB001 Page 38 1.07 - 1/9/04
Page 40
Integration Guide Version 1.07
9.3 Enfora AT Command Set
For a full description of the AT commands, refer to the Enfora Enabler-G AT Command Set Reference ­GSM0102PB001MAN.
Note: A command description that includes an *asterisk denotes that the GSM service provider must enable supplementary services functionality before the command is available.
9.4 Enfora Packet Application Programming Interface
9.4.1 UDP-API Architecture
The following information provides an overview of the Enfora UDP-based API architecture. Full details are provided in the Enfora GSM-GPRS Family UDP-API Reference GSM0102PB002MAN.
Figure 13 provides the general structure for the UDP-API.
Host Computer
Create Control /
Status Message
Add UDP Header
Add IP Header
Add PPP Framing
Write to COM Port
Read Control / Status
Message
Decode UDP Header
Decode IP Header
Remove PPP Framing
Read from COM Port
Modem
Figure 13 UDP-API Structure
GSM0100PB001 Page 39 1.07 - 1/9/04
Page 41
Integration Guide Version 1.07
The following provides information related to the general construction of the UDP-API packet. Other command structures are available and can be found in the API reference manual.
All AT commands listed in the GSM0102PB001MAN document are supported via this method. To send an AT command via DUN or OTA, the user has to follow the following message structure. This message structure sends the ATI command to the modem and receives Enfora, Inc. response from the modem.
Bytes Data Description Comments
0 – 19 IP Header
20 – 27 UDP Header
28 0x00 29 0x01 30 0x04 AT Command Read/Write 31 0x00 Reserved 32 0x41 33 0x54 34 0x49
Following data will be returned by the modem:
Bytes Data Description Comments
0 – 19 IP Header
20 – 27 UDP Header
28 0x00 29 0x01 30 0x05 AT Command Response 31 0x00 Reserved 32 0x0D 33 0x0A 34 0x45 35 0x6E 36 0x66 37 0x6F 38 0x72 39 0x61 40 0x2C 41 0x20 42 0x49 43 0x6E 44 0x63 45 0x2E 46 0x0D 47 0x0A
Sequence Number
AT Command
(ATI)
Sequence Number
AT Command Response
(Enfora, Inc.)
GSM0100PB001 Page 40 1.07 - 1/9/04
Page 42
Integration Guide
Socket
Socket
Version 1.07
9.5 Enfora Modem Control Library Architecture
The following information provides an overview of the Enfora Modem Control Library architecture. Full details are provided in the Enfora GSM-GPRS Family Modem Control Library Reference GSM0000PB006MAN.
Figure 14 provides the general embedded architecture for the Enabler II-G modem. There are various levels of access provided to allow complete application design flexibility. SLIP access is not currently available.
GPRS Parameters Table
UDP Modem Library
Modem libraries
UDP Messaging Library
UDP SLIP Port Library UDP PPP Port Library UDP Socket Port Library
COM Port Library
Messaging libraries
Port libraries
Figure 14 Library Layout
The table below can be used to help decide which library configuration is the best for a project. SLIP access is not currently available.
Allows dynamic IP assignment
Allows multiple application to
access the modem
Allow AT Commands
Allows modem control
message
Provide modem control
message formatting
Provides modem parameters
database service
Suitable for microcontroller
programming
Requires TCP/IP stack
UDP SLIP Port
Library
UDP PPP Port
Library
UDP Socket Port
Library
UDP Messaging
Library with SLIP
UDP Messaging
Library with PPP
UDP Messaging
Library with
UDP Modem
Library with SLIP
UDP Modem
Benefits
Requirements
Library with PPP
UDP Modem
Library with
Memory usage Low Low Low Low Low Low High High High
Table 3 - Modem Library Configurations
GSM0100PB001 Page 41 1.07 - 1/9/04
Page 43
Integration Guide Version 1.07

9.5.1 Using Port Library

Figure 15 provides the architecture for Port Library access.
Host Control InterfaceHost Application
UART DriverPort Library
Host Modem
Figure 15 Using Port Library
Port Libraries provide the most basic modem access services. It converts modem control messages to either UDP SLIP or UDP PPP, and vice versa. SLIP access is not currently available.
SLIP Header IP Header UDP Header Modem Control Message SLIP End
Or
PPP Header IP Header UDP Header Modem Control Message PPP End

9.5.2 Using Messaging Library

Figure 16 provides the architecture for Messaging Library access.
Modem Control Message
Host Application
Messaging Library
Host Modem
Host Control Interface
UART DriverPort Library
Figure 16 Using Messaging Library
Messaging Library provides some important modem access services. It builds a modem control message and converts the message to either UDP SLIP or UDP PPP before sending the data to the modem. It also parses the modem control messages from the modem. SLIP access is not currently available.
Parameter, Data
SLIP Header IP Header UDP Header
Modem Control Message
Or
PPP Header IP Header UDP Header
Modem Control Message
SLIP End
PPP End
GSM0100PB001 Page 42 1.07 - 1/9/04
Page 44
Integration Guide Version 1.07

9.5.3 Using Modem Library

Figure 17 provides the architecture for Modem Library access.
Host Application
Modem Library
Messaging Library
Host Modem
Host Control Interface
UART DriverPort Library
Figure 17 Using Modem Library
Modem Library provides the most complete modem access services. In addition to the features already provided by the Messaging Library, the modem library maintains a modem parameter database. In order to maintain the parameter database, the modem library requires more memory than the other libraries. This makes the library unsuitable for some of the micro controller programming. However, it is a good library to use by applications in a personal computer or a PDA. It allows the programmer to develop host applications for the modem quickly.
GSM0100PB001 Page 43 1.07 - 1/9/04
Page 45
Integration Guide Version 1.07
10.0 Setup and Initialization
10.1 General Setup
The GPRS modem is controlled through the Modem RS232 port on the development board. Connect a nine pin straight through serial cable from the Modem RS232 connector to the serial port on the controlling computer.
Hook up power supply, connect antenna, and install SIM into modem.
10.1.1 HyperTerminal Configuration for Enabler II-G
The following provides an example for setting up a Windows HyperTerminal session that can be used to experiment with various configurations on the Enabler II-G for controlling computer:
1. Select the connection interface, Direct to Com 1 (or whatever port is the serial port).
Figure 18 HyperTerminal Definition
GSM0100PB001 Page 44 1.07 - 1/9/04
Page 46
Integration Guide Version 1.07
2. Configure the COM port as displayed below.
Figure 19 COM Port Settings
10.1.2 Initialization (AT Command Interface)
In the GSM vocabulary, a call from GSM mobile to the PSTN is called a "mobile-originated call" or "outgoing call". A call from the fixed network to a GSM mobile is called a "mobile-terminated call" or "incoming call."
In the following examples, “Entry” refers to the application. The following convention describes the direction of the data exchange:
The data exchange from the customer application to the Enfora Enabler II-G module is designated as:
Entry
The data exchange from the Enfora Enabler II-G module to the customer application is designated as:
Response
Note: With the exception of the +++ command (Online Escape Sequence), all commands must be preceded
by the AT attention code (or command prefix) and terminated by pressing the <CR> character.
In the following examples, the <CR> and <CR><LF> are intentionally omitted for clarity and space.
GSM0100PB001 Page 45 1.07 - 1/9/04
Page 47
Integration Guide Version 1.07
10.1.3 Initial Response to the AT Command
After power is applied to the Enfora Enabler II-G module, the module performs a power-up self-test. The self-test completes within one (1) second. When queried with the AT command, the Enfora Enabler II-G module responds with one of the following result codes:
OK signifies that the Enfora Enabler II-G module is ready, that it correctly interprets the AT command, and that it has executed the command.
ERROR signifies that the Enfora Enabler II-G module does not understand the command or that the command is invalid.
Entry
Response
The Enfora Enabler II-G module must be in AT Command mode (please refer to section 10.3 GPRS Packet Examples for packet mode initialization and setup) when any command is entered (with the exception of the online escape sequence). Commands entered when the module is in On-line mode are treated as data, and are transmitted as such to the receiving module. i.e. If the module is in PPP or SLIP mode, AT commands cannot be entered.
10.1.4 Sending an Initialization String to the Enfora Enabler II-G Module
The following example provides the sample AT commands and responses for the following initialization tasks:
Reset the module to the factory defaults
Disable character echo
Transmit Result Codes
Set the module to Verbose mode (to display result codes as words)
Set the DCD to match the state of remote modem
Ignore the DTR
Entry
Response
Entry
Response
10.1.5 Setting Up the Communication Mode for the Enfora Enabler II-G Module
The following example sequence provides the AT command and response for setting the Enfora Enabler II­G module for full phone functionality, automated operator selection, 9600 baud, non-transparent mode.
Entry
Response
Entry
Response
Entry
Response
AT&FE0Q0V1&C1&d0 Initialization string OK Command is valid ATSO=1 Auto answer on 1st ring OK Command is valid
AT+CFUN=1 FULL phone functionality OK Command is valid AT+COPS=0 Automatic operator selection OK Command is valid AT+CBST=7,0,1 9600 baud, non-transparent mode OK Command is valid
AT OK Command valid: module is ready
GSM0100PB001 Page 46 1.07 - 1/9/04
Page 48
Integration Guide Version 1.07
10.1.6 Querying the Status of the Enfora Enabler II-G Module
This topic is addressed in the Enfora Application Note GSM0000AN006 – Enabler-G Module Status Query.
10.1.7 Setting Module Reporting Parameters for GSM and GPRS
This topic is addressed in the Enfora Application Note GSM0000AN007 - Enabler-G Status Reporting.
10.2 GSM/SMS Examples
10.2.1 Initialize the Enfora Enabler II-G Module to Send and Receive SMS Text Messages
This topic is addressed in the Enfora Application Note GSM0000AN004 - Enabler-G SMS Configuration and Use.
10.2.2 Managing SMS Messages
This topic is addressed in the Enfora Application Note GSM0000AN004 - Enabler-G SMS Configuration and Use.
10.2.3 Data Call Configuration
This topic is addressed in the Enfora Application Note GSM0000AN003 - Enabler-G Data Circuit Switched Call Configuration and Use.
10.2.4 Voice Call Configuration
This topic is addressed in the Enfora Application Note GSM0000AN003 - Enabler-G Data Circuit Switched Call Configuration and Use.

10.3 GPRS Packet Examples

10.3.1 GPRS ATTACH and ACTIVATE
This topic is addressed in the Enfora Application Note GSM0000AN005 - Enabler-G Automated Network Connection Configuration and Use.
10.3.2 Windows PPP Setup
The Enabler II-G module can be used in a Windows operating system environment as a standard serial modem device. The required setup and configuration process is contained in Enfora Application Notes
GSM0000AN001 - Enabler-G PPP Configuration for Windows 98 and GSM0000AN002 - Enabler-G PPP Configuration for Windows 2000.
GSM0100PB001 Page 47 1.07 - 1/9/04
Page 49
Integration Guide Version 1.07
11.0 Integration and Testing
The Enfora Enabler II-G module has been designed to minimize the amount of time required for integration and testing the application. By being fully certified by the appropriate bodies, the Enfora Enabler II-G module provides seamless integration into the GSM network.
The integration issues for the application can be narrowed to the utilization of the AT commands and the use of the GSM functionality. Coverage and signal quality may be evaluated by using the RSSI commands. Additional network information can be determined by using AT commands.
Integration of the GPRS Packet capabilities is more complicated than using AT command sequences to initiate the connection and begin transferring data. The following Application Notes should be used to integrate the GPRS packet capabilities:
GSM0000AN001 - Enabler-G PPP Configuration for Windows 98
GSM0000AN002 - Enabler-G PPP Configuration for Windows 2000
GSM0000AN008 - Enabler-G PPP Configuration for Windows XP
GSM0000AN010 - Enabler-G PPP Configuration for PocketPC 2002
GSM0000AN005 - Enabler-G Automated Network Connection Configuration and Use

Integrating the Enfora Enabler II-G Module

Note: Generally, all interfaces that are externally available to the end user need to be ESD-
conditioned and terminated in some way. Many of these interfaces should not be connected with power applied.
At the highest level, this is done using some type of GSM test equipment (such as, Racal 6103E), a computer, and a serial interface tester. The GSM test equipment must be able to simulate a GSM call and measure the key parameters related to the module.
Additionally, the serial interfaces and some minimal SIM functionality can be verified by sending AT commands to the Enfora Enabler II-G module.
All of these conditions need to be verified at ambient as well as extreme conditions.
As part of integration, each of the following interfaces must be verified:
Information Recommendations SIM
Primary and secondary serial Interfaces Reset Interface Audio/Microphone Interface
The maximum line length of the SIM interface is 25.4 cm (10 inches).
The Enfora Enabler II-G module takes care of the signal conditioning
As a minimum, an external application with a remote SIM will require a standard SIM carrier.
Filter the SIM VCC signal with a 10 uf / 10 V capacitor to help with the line length.
The Enfora Enabler II-G module uses a 3 V digital interface. The RS-232 signals must be level-shifted to get standard levels. These signals must be ESD-protected.
Resets the Enfora Enabler II-G module when tied low. Preliminary balancing on Enfora Enabler II-G module. Maximum length TBD
GSM0100PB001 Page 48 1.07 - 1/9/04
Page 50
Integration Guide Version 1.07
Testing the following parameters verifies the RF parameters that may be affected by such things as RF path loss, power supply noise, and external interference.
Functionality Parameters to be Tested Transmitter
Receiver
Testing the following GSM functionality verifies proper network communication.
Functionality Parameters to be Tested Transmitter
Receiver
Testing the following GSM functionality verifies proper network communication.
Functionality Parameters to be Tested Network Function
Frequency Error Phase Error PA Ramp Modulation Spectrum RF Power Steps Timing Advance BER Based RX Tests (RXQUAL RXLEV) BER Based Sensitivity
Frequency Error Phase Error PA Ramp Modulation Spectrum RF Power Steps Timing Advance
BER Based RX Tests (RXQUAL RXLEV) BER Based Sensitivity
Synchronization and registration Call set-up and call termination (both MT and MO calls) SMS and/or data calls
GSM0100PB001 Page 49 1.07 - 1/9/04
Page 51
Integration Guide Version 1.07

APPENDIX A - Warranty Repair and Return Policy

ENFORA, INC. 12-MONTH LIMITED WARRANTY
Enfora, Inc. warrants the products that it manufactures to be free from defects in materials and workmanship for a period of 12 months from the date of shipment from Enfora. This warranty is limited to the original purchaser of the product and is not transferable.
During the 12-month warranty period, Enfora will repair or replace, as its option, any defective products or parts at no additional charge provided that the product is returned, shipping prepaid, to Enfora. The purchaser is responsible for insuring any product so returned and assumes the risk of loss during shipping. All replaced parts become the property of Enfora.
During the 12-month warranty period, Enfora will also provide any software updates, at its option, at no additional charge. Any additional hardware that may be required to support the upgrade will be quoted as an option on the request of the customer.
Equipment add-ons, software modules, or software upgrades purchased or provided at no charge for existing equipment are warranted for the length of the existing equipment warranty, extended warranty or 90 days (whichever is less).
THIS LIMITED WARRANTY DOES NOT EXTEND TO ANY PRODUCTS WHICH HAVE BEEN DAMAGED AS A RESULT OF ACCIDENT, MISUSE, ABUSE, OR AS A RESULT OF SERVICE OR MODIFICATION BY ANYONE OTHER THAN ENFORA.
EXCEPT AS EXPRESSLY SET FORTH ABOVE, NO OTHER WARRANTIES ARE EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY WARRRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND ENFORA EXPRESSLY DISCLAMES ALL WARRANTIES NOT STATED HEREIN. AS WARRRANTED ABOVE THE PURCHASER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT AS PROVIDED ABOVE. UNDER NO CIRCUMSTANCES WILL ENFORA BE LIABLE TO THE PURCHASER OR ANY OTHE USER FOR ANY DAMAGES, INCLUDING AND INCIDENTAL OR CONSEQUENTIAL DAMAGES, EXPENSES, LOST PROFITS, LOST SAVINGS, OR OTHER DAMAGES ARISING OUT OF THE USE OF OR INABILITY TO USE THE PRODUCT.

Reporting and Troubleshooting Problems with the Enfora Enabler II-G Module

Problems can be reported by calling Customer Service. The Customer Service representative and/or service technician will attempt to resolve the problem over the telephone. It is important to note the exact environment that the problem occurs and what is the integration platform. For example, does the problem occur only in the Enfora Enabler II-G test fixture or in the target platform?
If the problem cannot be resolved over the telephone and the module needs to be returned, the customer service representative provides an RMA number for shipping the module. The return address will be given at this time. Upon receipt of the module, it will be thoroughly tested in an Enfora test fixture. If the problem is found, a replacement module will be shipped back to the customer.
Note: The warranty period for replaced or repaired equipment is 30 days from time of shipment.
GSM0100PB001 Page 50 1.07 - 1/9/04
Page 52
Integration Guide Version 1.07

APPENDIX B - Regulations and Compliance

This section summarizes the responsibilities and actions required of manufacturers and integrators who incorporate OEM versions of the Enfora Enabler II-G module into their products. In certain situations and applications, these products will require additional FCC, CE, GCF, PTCRB or other regulatory approvals prior to sale or operation. Appropriate instructions, documentation and labels are required for all products. For more information concerning regulatory requirements, please contact Enfora.

GCF Approval (Formerly FTA)

The Enfora Enabler II-G module is type approved in accordance with the requirements of and through the procedures set forth by the GSM industry association. The relevant conformance specification is GSM
11.10-1 for GSM 850, 900, and 1800 MHz devices. For PCS 1900 MHz devices, the relevant standard is
PCS 11.10, a version of GSM 11.10-1 that has been modified as appropriate for the North American GSM market. For applications that use an unmodified version of the Enfora Enabler II-G module, further testing in this area may not be required. Any OEM changes in the SIM interface, antenna port, software or the physical makeup of the unit may require an incremental FTA to ensure continued compliance with the above-mentioned standards. For more information concerning type approval, please contact Enfora.

Electromagnetic Compatibility (EMC) and Safety Requirements

The Enfora Enabler II-G module has been tested and approved for application in the United States of America (US) and the European Union (EU). The compliance details for each of these markets follow. For other markets, additional or alternative regulatory approvals may be required. Always ensure that all rules and regulations are complied with in every country that the OEM application is to be operated. Regardless of the country or market, the OEM must comply with all applicable regulatory requirements.

EMC/Safety Requirements for the USA

Compliance to the US rules and regulations falls under two categories:
Radio approvals: Federal Communications Commission (FCC)
Transmitter: FCC Rules, Part 24
Unintentional emission: FCC Rules, Part 15
Product safety approvals: NRTL by an OSHA-approved Nationally Recognized Testing Laboratory
(NRTL)
Although the Enfora Enabler II-G module has been authorized by the FCC and listed as a component by an NRTL, products and applications that incorporate the Enfora Enabler II-G module will require final verification of EM emission and product safety approval.
Note: Particular attention should be made to the following statements regarding RF Exposure
:
GSM0100PB001 Page 51 1.07 - 1/9/04
Page 53
Integration Guide Version 1.07

Human Exposure Compliance Statement

GSM0107 Tri-Band Module
Enfora certifies that the Enfora Enabler II-G 900/1800/1900 MHz GSM Radio Module (FCC ID: MIVGSM0107M) complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 24, Subpart E of the FCC Rules and Regulations. This certification is contingent upon installation, operation and use of the Enfora Enabler II-G and its host product in accordance with all instructions provided to both the OEM and end used. When installed and operated in a manner consistent with the instructions provided, the Enfora Enabler II-G meets the maximum permissible exposure (MPE) limits for general population / uncontrolled exposure at defined in Section 1.1310 of the FCC Rules and Regulations.
GSM0108 Quad-Band Module
Enfora certifies that the Enfora Enabler II-G 850/900/1800/1900 MHz GSM Radio Module (FCC ID: MIVGSM0108) complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 24 (and Part 22 for GSM 850), Subpart E of the FCC Rules and Regulations. This certification is contingent upon installation, operation and use of the Enfora Enabler II-G and its host product in accordance with all instructions provided to both the OEM and end used. When installed and operated in a manner consistent with the instructions provided, the Enfora Enabler II-G meets the maximum permissible exposure (MPE) limits for general population / uncontrolled exposure at defined in Section 1.1310 of the FCC Rules and Regulations.
Note: Installation and operation of this equipment must comply with all applicable FCC Rules and Regulations, including those that implement the National Environmental Policy Act of 1969 (Part 1, Subpart I), with specific regard to antenna sitting and human exposure to radio frequency radiation. For further guidance, consult the FCC Rules, your service provider, or Enfora.

Compliance with FCC Regulations

The Federal Communications Commission (FCC) is the agency of the Federal Government that oversees all non-governmental radio frequency transmitters that operate within the United States. Unintentional emissions from digital devices are regulated by Part 15 of the FCC Rules and Regulations, which distinguishes between the environments in which these devices may operate. Intentional radiators operating as a PCS-1900 radio transmitter are regulated under Part 24, Subpart E—Broadband PCS of the FCC Rules and Regulations.
GSM0100PB001 Page 52 1.07 - 1/9/04
Page 54
Integration Guide Version 1.07

Unintentional Radiators, Part 15

Equipment designated as Class A is intended for use in a commercial, industrial or business environment. The Enfora Enabler II-G module has been tested and found to comply with the limits for a Class A digital device and can be integrated into equipment or applications intended for use in commercial, industrial or business environments.
The following statement must be included in the user manual for such products:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Equipment intended for use in a residential environment (not-withstanding use in commercial, industrial or business environments) is designated as Class B. The Enfora Enabler II-G module has been tested and found to comply with the limits for a Class B digital device and can be integrated into equipment or applications intended for use in residential environments.
The following statement must be included in the user manual for such products:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.

Intentional Radiators, Part 24

Products incorporating the Enfora Enabler II-G transceiver operate as Personal Communications Services (PCS) devices under the authority of Part 24, Subpart E—Broadband PCS, of the FCC Rules and Regulations. All such transmitters must be authorized by the FCC through its Certification process, as detailed in Part 2, Subpart J - Equipment Authorization Procedures. Through the Certification process, the FCC verifies that the product complies with all applicable regulatory and technical requirements, including those that address human exposure to radio frequency radiation. In general, radio frequency transmitters cannot be sold or operated in the US prior to FCC approval.
GSM0100PB001 Page 53 1.07 - 1/9/04
Page 55
Integration Guide Version 1.07

Instructions to the Original Equipment Manufacturer (OEM)

To comply with the requirements of the National Environmental Policy Act (NEPA) of 1969, operation of an FCC-regulated transmitter may not result in human exposure to radio frequency radiation in excess of the applicable health and safety guidelines established by the FCC. Further information on RF exposure issues may be found in the FCC's Office of Engineering and Technology (OET) Bulletin Number 65, "Evaluating Compliance with FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic Fields" and Supplement C, "Additional Information for Evaluating Compliance of Mobile and Portable devices with FCC Limits for Human Exposure to Radio Frequency Emissions.” Both of these documents are available via the Internet at the OET web site: http://www.fcc.gov/oet
The Enfora Enabler II-G products are GSM radio transceivers, which operate under the authority of 47 CFR Part 24, Subpart E of the FCC Rules and Regulations. When installed and operated in accordance with the instructions provided in this manual, these devices comply with current FCC regulations regarding human exposure to radio frequency radiation.
The following installation and operation restrictions apply to all Enfora Enabler II-G products:
This device may only be used in fixed and mobile applications.
Portable applications, as defined by the FCC, are prohibited.
The use of this device for desktop and other applications where the antenna can easily be
relocated are considered by the FCC to be mobile applications.
A separation distance of at least 20 cm (7.87 inches) between the antenna and the body of the user and other persons must be maintained at all times
In FIXED applications, antenna gain is limited to a maximum of 7 dBi, with a corresponding Equivalent Isotropic Radiated Power (EIRP) of 37 dBm / 5 W.
In MOBILE applications, antenna gain is limited to a maximum of 3 dBi, with a corresponding EIRP of 33 dBm / 2 W.
End products must provide instructions to ensure compliance with radio frequency radiation exposure requirements.
A warning label visible to all persons exposed to the antenna and identical to that described in this manual must be displayed on or next to the antenna.
Separate FCC approval for RF exposure compliance is required for end products that do not meet these conditions.
Antenna gain is defined as gain in dBi (dB referenced to an isotropic radiator) minus cabling loss.
GSM0100PB001 Page 54 1.07 - 1/9/04
Page 56
Integration Guide Version 1.07
Note: Additional care must be taken by the installer and/or user of the Enfora Enabler II-G products to
ensure proper antenna selection and installation. Adherence to the above conditions is necessary to comply with FCC requirements for safe operation regarding exposure to RF radiation.
Depending upon the application and type of product into which the Enfora Enabler II-G module has been incorporated, specific OEM actions and responsibilities required to meet these conditions vary. However, in all cases the primary concern is to ensure compliance with current FCC guidelines and regulations that limit human exposure to radio frequency radiation.
Definitions
For the purpose of determining compliance with current FCC rules addressing human exposure to radio frequency radiation, the FCC has established the following three categories of transmitting devices:
Portable Devices – devices where the antenna is located within 20 cm (7.87 inches) of any person, including the user, if applicable. Portable devices operating under the authority of Part 24 (broadband PCS) are limited to a maximum of 2 W EIRP.
Mobile Devices – devices designed to be used in other than fixed locations and generally such that the antenna is located at a minimum of 20 cm (7.87 inches) from any person, including the user, if applicable. Mobile devices operating under the authority of Part 24 (broadband PCS) are limited to a maximum of 2 W EIRP.
Fixed devices – devices in which the antenna, either integral to the product or remotely located, is physically secured at one location and is not able to be easily moved to another location.
GSM0100PB001 Page 55 1.07 - 1/9/04
Page 57
Integration Guide Version 1.07

OEM Responsibilities for All Products Containing the Enabler II-G

In addition to any other regulatory requirements, OEMs and integrators must include or provide the following information, instructions, warnings and labels with any device or product into which the Enfora Enabler II-G PCS-1900 GSM transceiver has been incorporated:
Information Description Detailed Operating Instructions for
ensuring compliance with current FCC guidelines which limit human exposure to radio frequency radiation
Antenna Avoidance Label
Human Exposure Compliance Statement
The OEM must provide an operating/installation manual with the final product which clearly indicates that these operating conditions and restrictions must be observed at all times to ensure compliance with current FCC guidelines which limit human exposure to radio frequency radiation. 20 cm (7.87 inch) separation distance between the antenna and all persons must be maintained at all times for all fixed and mobile products and applications Portable devices and applications are prohibited unless such devices and products are specifically authorized by the FCC Maximum antenna gain is limited to 3 dBi* in mobile products and applications Maximum antenna gain is limited to 7 dBi* in fixed products and applications. Modifications and/or additions to the Enfora Enabler II-G GSM transceiver, including use of antennas with higher gain than those authorized by the FCC, are prohibited
*dBi = antenna gain in dB relative to an isotropic radiator Attach the following warning label directly to or displayed next to the antenna. Furthermore, this label must be visible to and easily readable by all persons in the immediate vicinity of the antenna
Include the following statement in the instruction / operation manual.
WARNING
To comply with FCC RF exposure
requirements, a separation distance of 20 cm (7.87”) or more must be maintained between this
antenna and all persons
Enfora certifies that the Enfora Enabler II-G ™ MHz GSM Radio Module (FCC ID: MIVGSM0107 or MIVGSM0108) complies with the RF hazard requirements applicable to broadband PCS equipment operating under the authority of 47 CFR Part 24, Subpart E of the FCC Rules and Regulations. This certification is contingent upon installation, operation and use of the Enfora Enabler II-G and its host product in accordance with all instructions provided to both the OEM and end used. When installed and operated in a manner consistent with the instructions provided, the Enfora Enabler II-G meets the maximum permissible exposure (MPE) limits for general population / uncontrolled exposure at defined in Section 1.1310 of the FCC Rules and Regulations.
GSM0100PB001 Page 56 1.07 - 1/9/04
Page 58
Integration Guide Version 1.07

Specific OEM Responsibilities for Portable Products and Applications

Each device or product, into which the Enfora Enabler II-G PCS-1900 GSM transceiver has been incorporated, and which is intended to be used in an application that meets the definition of "portable" MUST be separately authorized by the FCC for the purposes of determining compliance with current FCC guidelines limiting human exposure to radio frequency radiation.
Portable devices must be evaluated for RF exposure based on Specific Absorption Rate (SAR) limits; further information on such evaluations are available from the FCC via the Internet.

Specific OEM Responsibilities for Mobile Products and Applications

Separate or additional FCC approvals are NOT required for devices or products, into which the Enfora Enabler II-G PCS-1900 GSM transceiver has been incorporated, that are used in applications that meet the definition of "mobile."
For all end products, the OEM or integrator must provide instructions, warnings and labels to ensure that the product complies with current FCC guidelines limiting human exposure to radio frequency radiation.
Current FCC regulations limit the EIRP of mobile devices to 2 W. Because the nominal RF output power of the Enfora Enabler II-G PCS-1900 GSM transceiver is 1.0 W (30 dBm), antenna gain for mobile products and applications cannot exceed 3 dBi.

Specific OEM Responsibilities for Fixed Products and Applications

Separate or additional FCC approvals are not required for devices or products, into which the Enfora Enabler II-G GSM transceiver has been incorporated, that are used in applications that meet the definition of "fixed.”
For all end products, the OEM or integrator must provide the instructions, warnings and labels to ensure that the product complies with current FCC guidelines limiting human exposure to radio frequency radiation.
Separate or additional FCC approvals are required for devices or end products used in fixed applications where antenna gain in excess of 7dBi is desired.

Nationally Recognized Testing Laboratory (NRTL) Approval

The Enfora Enabler II-G module has been tested by an NRTL and approved as a component for incorporation into OEM products. The final product and application that incorporates the Enfora Enabler II-G module will require separate verification of product safety approval.
GSM0100PB001 Page 57 1.07 - 1/9/04
Page 59
Integration Guide Version 1.07

EMC/Safety Requirements for the Countries of the European Union (EU)

The European Union (EU) is comprised of fifteen countries that follow a harmonized set of standards, utilizing the CE mark as a uniform mark of acceptance. The member countries are:
Austria
Belgium
Denmark
Finland
France
Germany
Greece
Ireland
Italy
Luxembourg
The Netherlands
Portugal
Spain
Sweden
United Kingdom

EMC/Safety Requirements for Other Countries

In most other countries that have not been listed above there are similar rules and regulations that must be met for importing the Enfora Enabler II-G module. Each may require a different mark of approval (for example, the CB Scheme) as an acceptance requirement. For each of these cases the country should identified, and the appropriate steps should be taken to meet the requirements set forth in the intended market.
GSM0100PB001 Page 58 1.07 - 1/9/04
Page 60
Integration Guide Version 1.07

APPENDIX C - Glossary and Acronyms

API App Application
AT Command Set
BER Bit Error Rate CMUX
CPE Customer Premise Equipment CSD Circuit Switched Data Dbi DCE Data Communications Equipment DCS Digital Cellular System
DTE Data Terminal Equipment EFR Enhanced Full Rate EIR Equipment Identity Register EIRP Equivalent Isotropic Radiated Power EMC Electromagnetic Compatibility ESD Electrostatic Discharge EU European Union FTA Full Type Approval GPRS General Packet Radio Service GSM Global System for Mobile Communications HLR Home Location Register IMEI International Mobile Equipment Identity IMSI International Mobile Subscriber Identification Ki
MO Mobile Originated MT Mobile Terminated MSC Mobile Switching Center
Application Programming Interface. Refers to the Application which sends or receives commands/responses from the Enfora Enabler II-G Module Commands issued by intelligent device to a modem to perform functions, such as to initiate call, to answer call, or to transmit data. Bit Error Rate
Multiplexer protocol that operates between an MS and a TE and allows a number of simultaneous sessions over a normal serial asynchronous interface A terminal in fixed location on the customer’s premises.
Data link from a terminal through the network allowing real-time, duplex connectivity at 9600 bytes/second. Decibels referenced to an isotropic radiator Data Communications Equipment
A collection of services and capabilities providing flexibility of access and mobility through a combination of wireless and wire-line networks, utilizing the 1800 MHz bandwidth. Data Terminal Equipment
Voice (vocoder) compression algorithms which offer the highest quality voice communication. A database used to store International Mobile Equipment Identity (IMEI) of a locally issued terminal. In a given direction, the gain of a transmitting antenna multiplied by the net power accepted by the antenna from the connected transmitter.
The ability of a device to function satisfactorily in its electromagnetic environment without inducing intolerable disturbance to that environment (or to other devices) Static electricity that can damage electronic equipment.
An organization of 15 European states whose purpose is to organize relations between the Member States and between their peoples. GSM Full Type Approval
Standard for packet communications utilizing Global Standard for Mobility (GSM) infrastructure. Standard for digital communications. Allows consistent communications in various parts of the world despite variations in RF spectrum allocations. Transferring the SIM (see below) permits users to roam by changing terminal equipment. Stores the identity and user data for all subscribers belonging to the area of the related MSC. A unique number for each GSM Terminal tracked by the GSM operators in their Equipment Identity Register (EIR) database.
A unique number identifying the subscriber stored in the SIM card. Number is used in conjunction with the network for call routing.
A secret code used in authentication and encryption by the terminal.
Any GSM/GPRS service originated at the mobile terminal.
Any GSM/GPRS service originated from or routed through the network and sent to the mobile terminal. The central switch of the GSM network. Performs call routing, collects call detail records for billing, and supervises system operations.
GSM0100PB001 Page 59 1.07 - 1/9/04
Page 61
Integration Guide Version 1.07
Non-Transparent Mode
NRTL Nationally Recognized Test Laboratory OEM PA Packet PCS PDA PDU PPP SIM SMS SMSC UDP
Delivers a constantly low error rate but with a non-guaranteed throughput or delay. The Non-Transparent service provides a performance that is closest to using a modem over a fixed PSTN line. OSHA-approved Nationally Recognized Testing Laboratory
Original Equipment Manufacturer. Power Amplifier. A collection of data transmitted over a digital network in a burst. Personal Communication Services. Personal Digital Assistant. Packet Data Unit. Point-To-Point Protocol. Subscriber Identity Module. Short Message Service. Short Message Service Center. User Datagram Protocol.
GSM0100PB001 Page 60 1.07 - 1/9/04
Page 62
Integration Guide Version 1.07

APPENDIX D – Tables And Figures

TABLES
Table 1 - Enabler II-G Key Features.............................................................................................................. 10
Table 2 - Enabler II-G Pin Assignments ........................................................................................................ 26
Table 3 - Modem Library Configurations ....................................................................................................... 41
FIGURES
Figure 1 Applications Using the Enfora Enabler II-G module in a GSM/GPRS Network ............................... 13
Figure 2 Enabler II-G Module Block Diagram................................................................................................ 16
Figure 3 Enabler II-G Package Dimensions (without integrated SIM carrier) ................................................ 20
Figure 4 Enabler II-G Package Dimensions (with integrated SIM carrier) ..................................................... 21
Figure 5 Vertical Enabler II-G Mounting ........................................................................................................ 22
Figure 6 Enabler II-G Mounting Tabs ........................................................................................................... 22
Figure 7 Pin Orientation ................................................................................................................................ 23
Figure 8 PCB Integration I/O Control Connector ........................................................................................... 24
Figure 9 Ring Indicate Timing........................................................................................................................ 27
Figure 10 Enabler II-G Serial Interface.......................................................................................................... 28
Figure 11 Audio Reference............................................................................................................................ 31
Figure 12 Remote SIM Interface ................................................................................................................... 33
Figure 13 UDP-API Structure ........................................................................................................................ 39
Figure 14 Library Layout ............................................................................................................................... 41
Figure 15 Using Port Library.......................................................................................................................... 42
Figure 16 Using Messaging Library............................................................................................................... 42
Figure 17 Using Modem Library .................................................................................................................... 43
Figure 18 HyperTerminal Definition............................................................................................................... 44
Figure 19 COM Port Settings ........................................................................................................................ 45
GSM0100PB001 Page 61 1.07 - 1/9/04
Page 63
Integration Guide Version 1.07

APPENDIX E - Contacting Enfora

Please use the following contact information for customer or technical support questions.
Customer Support 972.633.4400
www.enfora.com/support Internet North America
www.enfora.com
Enfora, Inc.
661 E. 18th Street
Plano, TX 75074
Telephone
972.633.4400
GSM0100PB001 Page 62 1.07 - 1/9/04
Loading...