Novatel OM-20000015 User Manual

Addendum to the WAAS/GUS Receiver
Subsystem User Manual (OM-20000015 Rev 2)
ADD-019 Rev 1 June 9, 2000
Your Mini WAAS receiver is configured differently than a WAAS receiver. As a result, any references to MEDLL (L1 - C/A), in the above manual, do not apply.
The L1 - C/A port:
UPDATE, see the Firmware Upgrades chapter of the above manual).
is disabled for all user input (does not respond to any command
or log input) other than the LOADER and UPDATE comma nds, see point above.
ouputs the VERA log every 100 seconds at a rate of 9600 bps.
Here is an example of the VERA log’s syntax and output:
$VERA week seconds version*xx [CR][LF]
$VERA,37,492999.60,OEM-2 WAASMINI CGC96220002 HW 1 SW
5.444S8/1.03 May 02/00*36
NOTE: Although the MEDLL (L1 – C/A) receiver subsystem does not output any
measurement data, it is functionally active when time synchronizing the Mini WAAS receiver.