Nova-Tech pH-CON 10 User Manual

gyM
y..
.
Instruction Manual
PC 10
Waterproof Hand-held pH/Conductivity/Temperature Meter
68X230401
Tec hn ol o
adeEas
Rev 5 08/04
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
Preface
This manual serves to explain the use of the Waterproof PC 10 hand-held meters. It functions
as a step by step guide to help you operate the meter and as a handy reference guide. It is
written to cover as many anticipated applications of the Waterproof PC 10 meters as possible.
If there are doubts in the use of this meter, please do not hesitate to contact the nearest
Authorised Distributor.
Eutech Instruments/ Oakton Instruments cannot accept any responsibility for damage or
malfunction to the meter caused by improper use of the instrument.
The information presented in this manual is subject to change without notice as improvements
are made, and does not represent a commitment on the part of Eutech Instruments Pte Ltd/
Oakton Instruments.
Copyright © 1999
Eutech Instruments Pte Ltd/ Oakton Instruments
All rights reserved.
Rev 5, 08/04
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
TABLE OF CONTENTS
1.
INTRODUCTION ........................................................................................1
2. DISPLAY AND KEYPAD FUNCTIONS................................................... 2
2.1. D
2.2. K
ISPLAY................................................................................................. 2
EYPAD .................................................................................................3
3. PREPARATION........................................................................................... 4
3.1 I
3.2 C
NSERTING THE BATTERIES .................................................................... 4
ONNECTING THE PROBE ....................................................................... 5
4. CALIBRATION............................................................................................ 6
4.1. I
4.2. P
4.3. T
4.4.
NOTES
4.5. C
4.6. C
MPORTANT INFORMATION ON METER CALIBRATION ............................ 6
REPARING THE METER FOR CALIBRATION ........................................... 7
EMPERATURE CALIBRATION ................................................................ 8
PHCALIBRATION .................................................................................10
..................................................................................................................11
ONDUCTIVITY CALIBRATION .............................................................12
ALIBRATING FOR CONDUCTIVITY: ..................................................... 13
NOTES:
.................................................................................................................14
5. MEASUREMENT ......................................................................................15
6. HOLD FUNCTION .................................................................................... 16
7. PROBE CARE AND MAINTENANCE ................................................... 17
8. TROUBLESHOOTING .............................................................................18
9. ERROR MESSAGES .................................................................................19
10. SPECIFICATIONS................................................................................ 20
11. ACCESSORIES .....................................................................................21
11.1. R
11.2. C
EPLACEMENT METER AND METER ACCESSORIES ............................... 21
ALIBRATION SOLUTIONS.................................................................... 23
12. WARRANTY.......................................................................................... 24
13. RETURN OF ITEMS ............................................................................25
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
Instruction Manual PC 10
1. INTRODUCTION
Thank you for selecting the Waterproof PC 10 portable meter. The meter is a microprocessor-
based instrument that measures pH, conductivity, and temperature with just one probe. This
meter has many user-friendly features – all of which are completely accessible through the
water-resistant membrane keypad.
Your meter includes 4 “AAA” batteries and a combination pH / conductivity / temperature
probe with 3-meter submersible cable. Please read this manual thoroughly before operating
your meter.
WATERPROOF
pH/ Conductivity/ °C Meter
PC 10 Series
N
O
F
F
O
A
C
M
E
D
L
D
O
O
H
M
L
R
E
T
S
N
A
E
E
Figure 1: Waterproof PC 10 portable meter
- 1 -
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
Instruction Manual PC 10
2. DISPLAY AND KEYPAD FUNCTIONS
2.1. Display
The LCD has a primary and secondary display.
x The primary display shows the measured pH or conductivity (μS or mS)
reading.
x The secondary display shows the temperature in °C.
The display also shows error messages, keypad functions and program functions.
See Figure 2.
READY indicator
HOLD indicator
ERRor indicator
MEASurement mode indicator
READY
HOLD
ERR
CALibration indicator
CONfirm indicator
CONMEAS CAL
pH
P
mS
pH °C
ATC
Primary Display
Secondary Display
Buffer indicator
Probe indicator
Low Battery indicator
Figure 2: A full LCD screen
pH Temp
pH calibration mode indicator
- 2 -
Temperature calibration mode indicator
Automatic Temperature Compensation indicator
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
Instruction Manual PC 10
2.2. Keypad
The large membrane keypad makes the instrument easy to use. Each button, when pressed,
has a corresponding graphic indicator on the LCD. See Figure 3.
Key Function
ON/OFF Powers on and shuts off the meter. The meter powers on in the mode it was
shut off in. For example, if you shut the meter off in Conductivity measurement mode, the meter will be in Conductivity measurement mode when you switch the meter on.
HOLD Freezes the measured reading. To activate, press HOLD while in
measurement mode. To release, press HOLD again.
MODE Selects the measurement parameter (conductivity or pH). Press MODE to
toggle between pH and Conductivity mode.
CAL/MEAS Toggles user between Calibration and Measurement mode.
If you were in Conductivity Measurement mode, press CAL/MEAS to enter Conductivity Calibration mode.
If you were in pH Measurement mode, press CAL/MEAS to enter pH Calibration mode.
NOTE: Temperature calibration is accessible from pH Calibration mode; see
pages 10 for instructions.
ENTER Press to confirm your calibration values in Calibration mode.
S / T Scrolls values up and down in Calibration mode.
In pH mode, S / T scrolls through the auto buffer values 4.00, 7.00 and
10.00. In Conductivity and Temperature Calibration mode,S / T lets you increase
or decrease the calibration value.
Figure 3: Keypad membranes of Waterproof PC 10
- 3 -
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
Instruction Manual PC 10
3. PREPARATION
3.1 Inserting the Batteries
The meter is packaged with 4 “AAA” alkaline batteries required for operation. To insert the
batteries into the meter, follow the procedure outlined below.
1. Use a Philips screwdriver to remove the two screws holding the battery cover. See Figure
6 below.
2. Remove battery cover.
3. Insert batteries. Follow the diagram inside the cover for correct polarity.
4. Replace the battery cover into its original position using the two screws removed earlier.
Figure 4: Battery Compartment
- 4 -
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
Instruction Manual PC 10
3.2 Connecting the Probe
The Waterproof PC 10 meter uses a special combination pH / Conductivity / Temperature
probe. The probe cable has a notched 6-pin connector to attach the probe to the meter.
NOTE: Do not substitute other probes or electrodes. For replacement probe, see
the “Accessories” section, page 21-23.
NOTE: Keep connector dry and clean. Do not touch connector with soiled hands.
To connect the pH / Conductivity / Temperature probe:
1. Line up the notch and 6 pins of the meter’s connector with the holes in the probe’s
connector. Push down and screw the metal sleeve to lock the probe connector into
place. See Figure 5.
2. To remove probe, unscrew the metal sleeve and slide up the probe connector. While
holding onto metal sleeve, pull probe away from the meter.
CAUTION: Do not pull on the probe cord or the probe wires might disconnect.
Figure 5: Probe Connector
- 5 -
http://www.novatech-usa.com/Products/Laboratory-Equipment-Supply-Products Tel: (281) 359-8538 Toll Free:(866) 433-6682
Loading...
+ 20 hidden pages