information, which is specific to
this piece of equipment, in the
space provided. Our Parts/Service
Department will need these
numbers to properly respond to
any of your requests.
Model #:___________________________
Serial #____________________________
liable for errors contained in this Instruction
Manual nor for misinterpr etati o n of
information containe d her ei n. NOVATEC
shall not, in any event, be held liable for any
special, indirect or consequential damages
in connection w i th per for ma nce or use o f
7.5 Closed Loop Vacuum System ........................................................................................................................... 9
7.6 Ambient Air Vacuum System ............................................................................................................................. 9
9 STANDARD SPECIFICATIONS (3000 ft. Elevation and below) .................................... 16
10 OPERATING AT HIGH ELEVATIONS (3000 Ft Above Sea Level or More) ................ 16
11 PARTS LIST ............................................................................................................................. 17
12 MAINTENANCE AND INSPECTION S CHEDULE ............................................................. 18
12.1 EVERY WEEK ................................................................................................................................................. 18
12.2 EVERY MONTH .............................................................................................................................................. 18
12.3 EVERY 6 MONTHS ........................................................................................................................................ 19
12.3.1 Inspecting V Belts: ................................................................................................................................... 19
12.3.2 Replacing V Belts ..................................................................................................................................... 20
NOVATEC SVP Series Vacuum Pump is designed to pneumatically convey plastic pellets or
powders in a vacuum conveying system. It does this by creating a vacuum to “pull” air
through the piping system. Plastic pellets or powders are introduced into the moving air
stream in various ways, including through the use of probes, pick-up tubes, and rotary air
locks. The SVP is used in conjunction with vacuum chamber station valves, etc. to form the
conveying system, which is controlled with either Master Control or Distributed Control
Panels. Several vacuum power units may be designed into the system as required. Vacuum
conveying systems typically distribute material from silos, surge bins, blenders, or drying
hoppers to processing machinery.
2 WARNING
Always disconnect power before servicing. Only qualified technicians should service,
maintain, or repair the SVP. Before using this equipment, read in detail the product bulletins
and other information found in this manual. A safe installation is necessary before operating
the equipment. The instructions should be understood and followed before installing or
operating the equipme nt.
3 OPERATING LIMITATIONS
Operating At Higher Altitudes…3000 Ft Above Sea Level or More
Atmospheric pressure is lower at higher elevations and as a result, the compression of air by
the pump requires more work for vacuum conveying. In these higher altitude applications the
pressure relief valve of SVP pumps must be adjusted on site to prevent the pump from
damaging itself or the motor by attempting to compress air of reduced density to an unsafe
level. Contact Novatec Engineering or Service at the number on the front cover of this
manual when operating the pump at 3000 ft or higher elevation.
Blower exhaust temper at ure and motor cooling a re a fu nct ion of both v ac uu m lev el a nd
elevation. Blower exhaust temperature must not exceed 300°F to avoid premature blower
failure.
Decreased motor FL A l imi ts may requi re al te rnate ov er load p ro tec tion o r inc re ased fram e
size / hp.
3.1 Seek Time
Excessive starting and sto pping of the pump will reduce blower an d mot or l ife an d
void the warranty. Seek Time is a control par amete r tha t all ows y ou r pump to
operate for short periods in vacuum break mode (n o va cuum lo adin g) whil e the
system control se arches for new demands. Usi ng the Seek Time feature , pump
starts must be limited to 1
Please check:
T regulator settings – page 7 Electrical D rawi ngs pag es 11 -142 per hour to prevent
premature failure. The minimum Seek Time for a pump is 240 seconds
to prevent
exceeding 12 starts per hour. Optimum Seek Time may be set dependent upon
pump capacity, u tiliza tion, number o f s tations, capac ity o f each vacuum chamber ,
and individual station throughputs.
Caution should be exercised to see that the equipment is not handled roughly. The crate
must be removed carefully. The machine must not be used to pry against Do not pry against
the machine when removing the crate. The vacuum power unit is usually shipped
completely assembled and requires no further attention prior to installation. Note any
shipping damage on delivery receipt and report immediately to trucking company.
5 GENERAL INSPECTION
When the unit is unpacked, make a visual inspection looking for missing parts or damage
that may have occurred during shipment. Report any missing parts to Novatec immediately.
All electrical and mechanical connections should be checked for tightness, as vibration
during transit may cause them to loosen.
IMPORTANT:Before placing the vacuum pump into service, be sure oil has been put in the
pump, as oil may have been drained following factory quality control testing. See page 13 for
lubrication guidelines.
Locate the pump where it can be interconnected with the vacuum system piping easily.
Accommodations should be made to allow full access of the pump for service, especially the
belt guard, starter, filter, vacuum breaker valve, vacuum blower and vacuum relief valve.
The vacuum gauge should be visible, but can be carefully rotated in its fitting as required.
The pump should be secured to the floor to prevent movement from vibration and isolating
pads (not supplied) may be installed to minimize noise transfer to the floor, if desired.
The pump is commonly located near the vacuum conveying system’s cyclone dust collector
and is commonly connected directly to the cyclone lid with rigid tubing or flex hose. It is
convenient to service the dust collector and the pump filter at the same time.
See notes on electrical instal l ati o n for the 3 phase power connection and for installation of a
near-by 3 phase disconnect switch to allow easy disconnection of power to the pump for
service or in the case of an emergency.
Compressed Air Supply :
Clean compressed air should be supplied to the SVP pump’s vacuum breaker valve
regulator, providing 80 to 120 psi. A filter (not supplied) should be provided if the
cleanliness of the air is questionable.
7.1 Regulator Warning
The compressed air regulator has been set at the factory to allow the vacuum breaker
to relieve at the specified vacuum. Tampering with the regulator will void the
warranty. Only qualified Novatec service personnel may adjust the relief point via
regulator pressure.
7.2 Combination Vacuum Breaker and Vacuum Relief Valve
The Novatec vacuum breaker valve for system seek operation also serves as the
vacuum relief valve to regulate the pump’s workload. The dual functionalit y is
accomplished by utilizing an equilibrium of compressed air pressure and vacuum level
in conjunction with the vacuum breaker action, governed by the system’s conveying
control panel.
NOTE:
Specifications will be reduced for standard pump assemblies running on 50Hz.
Information shown is for standard SVP vacuum pumps. Refer to special job drawings
for custom unit information if applicable.
Connect the proper power supply (check nameplate) through a main line disconnect switch
(not supplied) to terminal connections L1, L2, L3 and ground into the MVP control cabinet
that contains the motor starter. This is the only power connection required since the motor i s
pre-wired at the factory. See schematic on the next page. See FLA specification table on
page 16.
Connect control wiring from the conveying system control panel to the same electrical
enclosure as shown on the wiring schematic for the conveying system control panel. Verify
the correct rotation of the motor with the directional labels on the pump assembly.
3 Phase Electrical Power:
1. Verify nameplate information on the pump frame asse mbl y
2. Use the FLA/KVA chart on page 15 as a guide
3. A nominally rated 3 phase disconnect switch must be provided
4. All connections must be provided in strict adherence to local and national codes by a
qualified electrician.
9 STANDARD SPECIFICATIONS (3000 ft. Elevation and below)
NOTE:
Information shown is for standard SVP series Positive Displacment vacuum pu mps.
Specifications will be reduced for pumps running on 50Hz. Specifications will change when
the pump is operated at elevati ons 3000 ft. or more above sea level (see below).
Refer to special job drawings for custom unit inf orm at ion as applicable. Verify nameplate
information on motor before installing and operating. All information is subject to change
without notice.
10 OPERATING AT HIGH ELEVATIONS (3000 Ft Above Sea Level or More)
Atmospheric pressure is lower at higher elevations and as a result, the compression of air by
the pump requires more work for vacuum conveying. In these higher altitude applications the
pressure relief valve of SVP pumps must be adjusted to prevent the pump from damagi ng
itself or the motor by attempting to compress air of reduced density to an unsafe
level. Failure to adjust the pump will void the pump warranty.
When the end-use site is known, Novatec endeavors to pre-adjust the vacuum pump’s
performance at the factory to compensate for elevations above 3000 feet. Novatec then
labels the vacuum relief valve accordingly. If your pum p-use site is 3000 feet above sea
level or more, and no indication of pre-adjustment is present on the pump assembly, please
contact Novatec Engineering or the Novatec Service Department at the number on the front
cover of this manual to get instructions for adjusting your SVP pump for use at elevat ions at
3000 feet or more above sea level.
*see lubrication chart on page 14 for recommended stocking level for oil.
NOTE: Parts shown are for standard SVP series vacuum pumps. Refer to special job
drawings for custom unit information. Verify information on existing part before ordering and
installing replacement. All information is subject to change without notice.
It is recommended that maintenance and inspection is done on a scheduled basis.
Maintenance requirements will naturally vary widely for each installation and specific
operating conditions. It is suggested that a complete inspection be performed with the
necessary maintenance at the end of the first day, the first week, the first month and the first
3 months. These inspections will be indicative of how often future maintenance will be
necessary.
12.1 EVERY WEEK
Inspect the Filter cartridge. Clean or replace as required. Remove any fines collected
from the catch pan. This time interval should be shortened if experience indicates
unusual dust loading. Check the system for air leaks and correct as required.
12.2 EVERY MONTH
Inspect the vacuum breaker valve filter/silencer. Clean or replace as required.
If service to the vacuum breaker is required remove it from the filter housing.
Disconnect power and check for loose electrical connections.
Tighten all bolts and nuts that may have loosened due to vibration.
Check V belts. Adjust or replace as follows:
12.3.1 Inspecting V Belt s:
1. Remove the pump from service and disconnect electrical power.
2. To inspect V belts, remove the 2 fastener s on the outs ide panel of the
belt guard (Figure 2, shown on the next page) and carefully examine
each belt for excessive stretch, looseness, frayed surfaces or exposed
cord. Replace all belts if one or more belts ar e found to be ex ces si v ely
worn. Always replace belts as a set; never individually.
3. Inspect the belt tension using the specifications in the following chart.
Once belts are found in good condition and tensioned properly, replace
the outside panel ensuring 2 fasteners are installed properly. Never
operate the pump without the belt guard firmly installed.
If broken, stretched or excessively worn belts require replacement:
1. Remove the entire belt guard by removing the 2 fastener s that
connect the cover to the pump base (see Figure 2, above) and lift the
cover straight up.
2. Loosen the motor’s mounting bolts and slide the motor base towards the
pump, allowing the belts to loosen. Remove the belts.
3. Confirm use of the proper replacement belts (see parts list) and install
Them carefully onto each sheave pulley. All belts must be replaced as a
set.
4. Re-tension the belts with the sliding motor base according to the chart
below. Note: new belts require greater initial tension than belts that
have been in operation. Double check the belt tension while tightening
the motor base and assure the motor stays in alignment while retightening.
5. Re-attach the belt guard ensuring the two fasteners are tight. Confirm that
no part of the belt guard comes in contact with rotating sheaves or belts.
Never operate the pump without the belt guard installed firmly.
Follow label instructions to
open/close drain valves.
1 1 2
2
Make sure that oil levels are filled only
13 LUBRICATION
13.1 Lubrication Guidelines
1. NOVATEC model SVP series vacuum pumps include splash lubricated bearings that
require no grease, but both the gear and shaft sides of the pump unit contain oil
sumps that must be maintained as part of your lubrication and oil replacement
procedures.
2. The lubrication should be changed after initial 100 hours of operation and every 2500
hours thereafter.
3. The proper oil level should be in the middle of the sight gauge when the blower is not
operating. DO NOT OVERFILL OIL SUMPS or damage to the blower may occur.
4. The oil level may naturally rise and/or fall in the gauge during operation, but the oil
level should not fall below the middle of the site gauge when the blower is idle.
Routine “topping up” of oil levels is NOT advised. Each pump examination should
include stopping the pump, allowing the oil level to stabilize and
then checking the level in the sight glass windows before adding
oil to the required level. See capacites and filling locations below.
15 WARRANTY – NOVATEC, INC. - Effective Date 7 FEB 2018
NOVATEC, INC. offers COMPREHENSIVE PRODUCT WARRANTIES on all
of our plastics auxili ary equipment. We warrant each NOVATEC manufactured
product to be free from defec ts in mate rials and workm anship, u nder normal
use and service for the periods listed under “Warranty Periods”. The
obligation of Novatec, under this warranty, is limited to repairing or
furnishing, without charge, a similar part to replace any part which
fails under normal use due to a material or workmanship defect, within
its respective warranty period. It is the purchaser’s responsibility to
provide Novatec with immediate written notice of any such suspected
defect. Warranted replacement parts are billed and shipped freigh t
pre-paid. The purchaser must return the suspect defective part, freight
prepaid and with identifying documentation to receiv e full credit for the
part returned. Novatec shall not be held liable for damages or delay
caused by defects. No allowance will be made for repairs or alterations
without the written consent or approv al of N ovatec .
Please n ote that we alwa ys strive to sat isfy our cust omers in whateve r manner is de emed most expedi ent to overcom e any issues in
connection with our equipment.
Warranty Periods:
Note: All warranty periods commence with the shipment of the equipment to the customer.
5-Year (Except 1-Year on Non-Novatec Buy-Out Items)
Resin Drying to Include
NovaWheel™ Dryers *
Dual Bed Dryers
NovaDrier *
NDM-5 Membrane Dryer
Gas-Fired Process Heaters
Gas-Fired Regeneration Heaters
Drying Hoppers
Central Drying Hopper Assemblies
Heater/Blower Units and Hot-Air Dryer
Silo Dehumidifiers
NovaVac Dryers *
Nitrogen NovaDriers (Nitro)
DryTemp Plus
Central System Controls to Include
FlexTouch™ Series Controls
FlexXpand™ Series Controls
OptiFlex™ Series Controls
PLC Communications Modules
Greenboard Communications Modules
LOGO! Mini PLC
MCS-600 Series Controls – (Distributed I/O)
MCS-400 Series Controls
CL Silo Manager
Moisture Measurement Equipment to Include
MoistureMaster®
PET Resin Crystallizers
The provisions in equipment specifications are descriptive, unless
expressly stated as warranties. The liability of Novatec to the
purchaser, except as to title, arising out of the supplying of the said
equipment, or its use, whether based upon warranty, contract or
negligence, shall not in any case exc eed the cost of correcting defects
in the equipment as herein provided. All such liability shall terminate
upon the expiration of said warranty periods. Novatec shall n ot in
any event be held liable for any special, indirect or consequential
damages. Commodities not manufactured by Novatec are warranted
and guaranteed to Nov at ec by the o rigi nal manufacturer and then only
to the extent that Novatec is able to enforce such warranty or
guaranty. Novatec, Inc. has not authorized anyone to make any
warranty or representation other than the warranty contained here.
Non-payment of invoice beyond 90 days will invalidate the warranty. A
renewed warranty can be purchased directly from Novatec.
Resin Blending and Feeding to Include
WSB Blenders, MaxiBatch & Feeders *
Gaylord Sweeper Systems
Downstream Extrusion Equipment to Include
C and NC Bessemer Series Cutters
NPS Bessemer Series Pullers
NPC Mini Puller/Cutter
All NS Series Servo Saws
All Cooling and Vacuum Tanks Manufactured by Novatec
Resin Conveying and Systems Components to Include
GSL Series Vacuum Loaders
GlassVu Loaders, Receivers and Hoppers
VL/VLP Series Loaders
VRH, VR, VR-FL & VRP Series Receivers
Compressed Air Loaders
AL-B Barrel Loader
Cyclone Dust Collectors
Conveying System Accessories
Surge Bins
Valves and Accessories
Electronic Metal Separators
Quick Select Manifolds
Tilt Tables
Filter Dust Collectors
Drawer Magnets
Velocity Control Valves
**5-Year Extended Warranty - When a MachineSense® data plan is activated for products with **, Novatec automatically extends the warranty to 5
years. The data plan must be activated within 60 days after product shipment, and remain active through the warranty period to maintain extended warranty
eligibility. The first 6-months of data plan usage is free from Novatec.
Vacuum Regenerative Blower Pumps
Custom Equipment of any kind unl ess otherwise specifi ed
Silencer Vacuum Pump Instruction Manual
Exclusions:
Routine m aint enance/ re placem ent p arts a re exc luded from the wa rrant y. Thes e inc lude , but are not lim ited t o: hos es, d esicc ant, fi lters,
filter el ements, wiper s eals, g askets, d ew point sensors , infra red lamp s, moto rs, inte rnal sol enoids, fuses a nd motor brushes. Use wit h
abrasive materials will void the warranty of any standard produc t. Wear resistant options may be available to extend usable servic e
life with abrasive materials.
the specifications of the original parts supplied by Novatec.
*Specific Exclusio ns:
1. NovaDrier and NovaDrier Nitrogen (Nitro) warranty is void if coalescing filters are not replaced on a 6-month or
2. NovaVac Dryer -The ability of the canisters to hold vacuum will be compromised if the vacuum seal edge is
3. LOAD CELLS on our WSB’s are covered by Novatec standard warranty as long as they have not been damaged
from improper handling .
4. Desiccant Wheel Warranty will be void if the wheel has been exposed to plasticizer, dust or other contaminants as a
result of ne gl igence on the part of the processor.
This warranty shall not apply to equipment:
1. Repaired or altered without written approval of NOVATEC unless such repair or
alteration was, in our judgment, not responsible for the failure
2. Which has been subject to misuse, negligence, accident or incorrect wiring by others
3. Warranty is void if processing rates exceed manufacturer-recommended levels or if damage is caused by
ineffective power isolation and/or power spikes/sags or incorrect installation.
NOTE: All conditions and content of this warranty are subject to changes without notice.
Novatec reserves the right to limit the warranty if t he customer installs replac ement parts that do not meet
yearly basis (per instruction manual) and/or membrane has been exposed to ozone.
damaged from mishandling. We do not warranty canisters damaged from improper handling. We do, however,