Novar ED&S Simple Set Reader, SS/01, SS/01/UB, SS/F, SS/F/UB User Manual

Simple Set Reader and Keyfobs
The simple set reader can be installed in a range of intruder system to allow ease of setting and unsetting the system using a keyfob. Each keyfob is unique and cannot be used unless it is recongised by the reader, which provides total security. A reader can learn to operate with up to eight keyfobs. There can be more than one reader installed in a system. These instructions cover how to mounting and wire the reader, where necessary how to engineer the panel and learn up to eight keyfob at a reader and how to operate the system using a keyfob. The products covered are: SS/01 ADE Simple Set Reader with 2 keyfobs SS/01/UB Unbranded Simple Set Reader with 2 Keyfobs SS/F ADE keyfob SS/F/UB Unbranded keyfob
Do’s
Before you begin installation do:
ÿ
check the Simple set reader can be connected to your intruder system and ensure the panel software is compatible, see wiring and programming
ÿ
ensure the Tamper wiring is connected to the reader
ÿ
mount each reader away from metal surfaces and large metal objects
ÿ
test the operation of the reader(s) using the keyfobs
ÿ
when using a keyfob, always hold the keyfob perpendicular to the surface of the reader to achieve maximum range, see photo above.
Technical Data
Mounting the reader
Wiring and programming
The simple set reader can be connected to an ADE G3 or Accenta range of intruder panels.
The wiring diagrams here show connection details, minimum panel software requirements and programming procedures. It may be possible to connect the reader to other intruder system, for further information call Technical Support for help.
ÿ
If you are installing the reader to an existing system then you will need to power down the system, note a tamper alarm will occur.
ÿ
Once you have connected the reader to your intruder panel you will need to power up the system. On powering up, the system will go into alarm. At a keypad enter the user code and reset the system. The Power and Day indicator should now be lit at all keypads and also at the readers.
ÿ
If the system requires programming to accept a keyswitch input, then follow the how to program instructions accompanying the appropriate wiring details.
ÿ
You can now set and unset the system using the keyfobs supplied with the reader, see operating instructions.
ÿ
You must now test the system to check the reader provides zone, tamper and attack indications.
NOTE: If you have addition keyfobs or have acquired new keyfobs to replace lost ones, then you will need to learn the keyfobs, see how to learn instructions.
draft
P2
RELAY
TAMP
SOUND
+13V
0V
COMMS
JUMPER
WD1
TAMP
Base
Cover assembly
Tamperspring locating collar
6- Thinned sections for cable entry
Cover fixing screw
Cable entry point
Mounting points
Tamperbreakout
If required cut-out the appropriate thinned section on the base.
Route the external cable through the base and fix the base using the two mounting points.
Connect the external cable to the terminal block on the cover assembly, see also wiring diagrams.
Clip the cover assembly to the base and ensure the tamper spring locates into the collar on the base. Secure the to the using thecover assembly base cover fixing screw.
TamperSpring
Tamper Spring
Base
Cover assembly
J5
0V
TAMP
+13V
COMMS
SOUND
1A
RKPFUSE
F2
Panel
Board
Simple Set Reader
Board
COMMS
12V
SOUND
LD R
Board
SOUND
TAMP
COMMS
13V
0V
Keypad
Board
GND
OPTI-CAM Lighting Controller
Where there is only one keypad and
it is part of the panel then connect
the TAMP back to the panel
How to connect the Simple Set Reader to a G3 intruder panel with Version 2.1 (xx/xx/02) or above
SOUND
TAMP
COMMS
13V
0V
RELAY
Cable distance 100m maximum
Maximum of up to 4 Remote Keypad /
Reader / OPTI-CAM Lighting Controller combination allowed
Simple Set
J5
0V
TAMP
+13V
COMMS
SOUND
1A
RKPFUSE
F2
Panel
Board
Simple Set Reader
Board
COMMS
12V
SOUND
LD
R
Maximum of up to 4 Remote Keypad /
Reader / OPTI-CAM Lighting Controller combination allowed
Simple Set
Board
SOUND
TAMP
COMMS
13V
0V
Keypad
Board
GND
OPTI-CAM Lighting Controller
How to connect the Simple Set Reader to a G3 range intruder panel with Software versions 1.2 (26/11/01), 1.1 (12/09/01), 1.0 (08/06/01)
J2
Zone 8
SOUND
TAMP
COMMS
13V
0V
RELAY
Zone configured to accept a Keyswitch input
Reset
Engineer Progam Mode
Prog
9 9 9 9 5 8
Zone
configuraion
Zone 8#
5
Keyswitch Input Zone
Reset
Reset
# Enter appropriate zone number if it is not zone 8
How to program Zone 8 for keyswitch input
Cable distance 100m maximum
Where there is only one keypad and
it is part of the panel then connect
the TAMPback to the panel
Press
Simple Set Reader
Board
SOUND
TAMP
COMMS
13V
0V
RELAY
J5
0V
+13V
COMMS
SOUND
1A
RKPFUSE
F2
Panel
Board
SOUND
TAMP
COMMS
13V
0V
Keypad
Board
If the keypad is part of the
panel then connect the TAMP
back to the panel
How to connect the Reader to an Accenta 8 Panel
TAMP
PTS
PTS configured to accept a Keyswitch input
Maximum of up to 4 Remote Keypad / Simple Set Reader combination allowed
Reset
Engineer Progam Mode
Prog
9 9 9 9 6 5
Flag
Configuration
Keyswitch input
How to program PTS as a remote keyswitch input
Cable distance 100m maximum
Press
Power - 13.8V dc from panel +/- 5%
maximum 75mA
Minimum range 20mm from centre of depression
keyfobs 8 maximum per reader
Dimensions 58.5 x 18.5mm 118x 84 x 22mm
Weight 4g 114g
Temperature 0 to +40 C
Colour Dark Grey Polycarb. White ABS
Mounting - Screws
Indications - Day - (green)
Learn - (amber)
Keyfob Reader SS/F & SS/F/UB SS/01 & SS/01/UB
º
Power, Zone, Error - (red) TA, and PA- (red)
Power Day ErrorLearn PATA
12345 768
ZONE
22mm
118mm
84mm
Keyfob
18.5mm
58.5mm
Reader
How to learn or re-learn additional keyfobs How to learn keyfobs if none are recognised by the Reader
Fault finding
Indication given.. what it means.. and what you could do.
Error
fast rate flash twice
per second
The jumper link on the PCB has been left fitted following learn operation
Remove the jumper link and keep in safe place for future use.
Error
slow rate flash
twice per second
Non volatile memory (NVM) communication error
Re-learn all keyfobs and if problem persists then contact technical support for help
Error
You are using an already learnt keyfob during learn operation or
you are offering an unlearnt keyfob to the reader during normal use
offer an unlearnt or learnt keyfob respectively.
Operating instructions
The reader will mimic all system indications given at other keypads in your system. The tamper indication is given by the indicator marked TA and personal attack by the indicator marked PA.
How to set the system
How to unset the system
768
Day ErrorLearn PATA
2345
ZONE
Reader
Power
1
Offer keyfob to the Reader and withdraw
Power
Day Learn Error TA
PA
1
2
3 4 5 6 7
8
ZONE
Keyfob recognition beep
If you do not withdraw keyfob after it is acknowledged by the reader, you run the risk of entering the This will erase at the all recognition of previously learnt keyfobs.
learn mode.
Reader
The indicator should be lit at the reader. Offer a to the reader and withdraw it as soon as you hear the
sound from the local sounder.
The system will now produce an exit beep and you should leave the premises by the exit route recommended by your installer. The system will set when the exit beep stops.
Day keyfob
keyfob acknowledge
When you leave your premises you will need to set (or turn on) the intruder alarm system. Before setting the system you should ensure that the premises have been completely vacated and that all doors and windows are closed. Ensure that pets do not have access to the protected areas as they can cause a false alarm.
Exit beep
Power
Day Learn Error TA
PA
1
2
3 4 5 6 7
8
ZONE
Once a Set / Unset operation is performed, wait for 5 seconds duration before next use of the keyfob to operate the system.
768
Day ErrorLearn PATA
2345
ZONE
Reader
Power
1
Offer keyfob to the Reader and withdraw
Power
Day Learn Error TA
PA
1
2
3 4 5 6 7
8
ZONE
Keyfob recognition beep
If you do not withdraw keyfob after it is acknowledged by the reader, you run the risk of entering the This will erase at the all recognition of previously learnt keyfobs. You will need to relearn all other keyfobs, see how to learn additional keyfobs.
learn mode.
Reader
Enter your premises by the route recommended by your installer. The system will produce an entry beep tone.
Offer a to the reader and withdraw it as soon as you hear the sound from the local sounder.
The system will stop the entry beep and light the green indicator.
If any Zone, Tamperor Attack indicator lights up then an alarm has occurred, and an intrusion may have taken place. Seek assistance before investigating further as intruders may still be on the premises. Then reset the system at the system keypad.
keyfob
keyfob acknowledge
Day
When you enter your premises you will need to unset (or turn off) the system.
Entry beep
Power
Day Learn Error TA
PA
1
2
3 4 5 6 7
8
ZONE
The panels conform to the requirements of the European EMC and Low Voltage directives, and carries the CE mark
For Technical Support
: 0906 302 0999
This is a premium rate line, calls are charged at 50 pence per minute
Novar ED&S
The Arnold Centre Paycocke Road Basildon SS14 3EA
By entering the you will erase at the all recognition of previously learnt keyfobs, expect the one used to enter the .
learn mode
learn mode
reader
Withdraw the away from the and hold the
and slightly touch the centre depression on the A learnt indication is given of the when the flashing indicator changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered indicator will start flashing.
You now have up to 10 seconds to start learning the another keyfob.
learnt keyfob reader
next keyfob reader.
next keyfob
ZONE
ZONE
keyfob recognised beep
PowerDay ErrorLearn PATA
12345 768
ZONE
Reader
Next keyfob
When an unrecognised keyfob is offered to the
it will cause the light to be lit and
continuous sound is emitted from the internal sounder.
The will timeout after 10 seconds if no actions is taken to learn the next keyfob
reader Error
learn mode
Use a recognised slightly touch it to the centre depression on the Reader without movement for 10 seconds.
Initially you will hear a keyfob recognition beep and 10 seconds later five rapid beeps from the local sounder. You are now in the The light will give a flashing indication and the light changes from flashing to steady On indication to recognise the . The is now ready to learn the , signalled by flashing indicator.
In the when an already learnt keyfob is offered to the an Error indication will be given.
‘learnt’ keyfob,
learnt keyfob reader
next keyfob
reader,
learn mode. Learn
ZONE 1
ZONE 2
learn mode
Power
Day Learn Error TA
PA
1
2 3 4 5 6 7
8
ZONE
Power
Day Learn Error TA
PA
1
2 3 4 5 6 7
8
ZONE
Repeat tolearn the
Once all the keyfobs are recognised ‘learnt’ by the
wait for just over 10 seconds to exit the
this is announced by two beeps from the
local sounder and return to mode indication.
next keyfob.
reader
learn mode,
Day
Power
Day Learn Error TA
PA
1
2 3 4 5 6 7
8
ZONE
x 2 beeps
keyfob recognised beep
PowerDay ErrorLearn PATA
12345 768
ZONE
Reader
Learnt keyfob
x 5 rapid beeps
Hold for 10 seconds
Power
Day Learn Error TA
PA
1
2 3 4 5 6 7
8
ZONE
Using a recognised the r can learn or relearn additional keyfobs, up to 8 in total. You may want to do this if you have additional keyfobs or after a keyfob is lost or stolen and you want to prevent the use of it to operate the system.
learnt keyfob eader
Keyfobs can be learnt by more than one
installed in a systemreader
Ensure the is in the day mode with the light lit. You should have one and up to 7 further keyfobs to be learnt. Have all the keyfobs available.
reader
learnt keyfob
Day
Withdraw the away from the and hold the
slightly touch the centre depression of the A learnt indication is given of the next keyfob when the flashing indicator changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered indicator starts flashing.
learnt keyfob reader
next keyfob reader.
ZONE
ZONE
You now have up to 10 seconds to start learning the next keyfob.
keyfob recognised beep
PowerDay ErrorLearn PATA
12345 768
ZONE
Reader
Next keyfob
Power
Day Learn Error TA
PA
1
2 3 4 5 6 7
8
ZONE
Hold the first keyfob 10mm away from the reader.
Once the is acknowledged by the the light changes from flashing to steady and there is a recognition beep given by the local sounder. The is now ready to learn the , signalled by flashing of indicator.
first keyfob reader
reader next keyfob
ZONE 1
ZONE 2
keyfob recognised beep
PowerDay ErrorLearn PATA
12345 768
ZONE
Reader
first keyfob
Power
Day Learn Error TA
PA
1
2 3 4 5 6 7
8
ZONE
x 5 rapid beeps
Repeat to learn the next keyfob.
Once all the keyfobs are recognised ‘learnt’ by the Reader wait for just over 10 seconds to exit the learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
Power
Day Learn Error TA
PA
1
2 3 4 5 6 7
8
ZONE
x 2 beeps
Hold
Ensure the is connected to the intruder system and the JUMPER link is fitted on the
Power up the intruder system and enter the User code at the system keypad to disarm the system. You will hear five rapid beeps to acknowledge the is in . Remove the JUMPER link from the
reader
reader PCB.
reader
reader PCB.
Learn mode
The will not timeout until the first keyfob is learnt.
learn mode
P2
RELAY
TAMP
SOUND
+13V
0V
COMMS
JUMPER
WD1
TAMP
JUMPER
Reader PCB
Power
Day Learn Error TA
PA
1
2
3 4 5 6 7
8
ZONE
Reader cover assembly
JUMPER
A can learn up to 8 keyfobs following power up of the intruder system.reader You must have all the keyfobs to be learnt available. You will need to learn keyfobs in this manner if no keyfobs are recognised by the Keyfobs can be learnt by more than one installed in a systemreader. reader
link fitted
link removed
Error beep