Notis NT-1000X30IR Installation And User Manual

Page 1
IR
Intelligent High-Speed Dome
Installation and User’s manual
English
V3.01
Please read the manual carefully before installing and using the unit.
Catalogue
Welcome.......................................................................................................................... 1
I Important Safeguards...............................................................................................2
II Installation Guide......................................................................................................4
2.1 PREPARATION FOR INSTALLATION
.........................................................................4
2.2 INSTALLATION
......................................................................................................5
Page 2
III Description of Functions.........................................................................................12
3.1 PERFORMANCE CHARACTERISTIC.......................................................................12
3.2 FUNCTION DECLARATION....................................................................................13
IV Technical parameter............................................................................................... 26
V Functional Instructions............................................................................................27
5.1 COMMON FUNCTION QUICK INSTRUCTION LIST.....................................................27
5.2 MENU OPERATION GUIDE...................................................................................33
Simple Trouble Shooting Table......................................................................................59
Lightning and Surge Protection.....................................................................................60
Propositional preventive maintenance........................................................................... 60
Page 3
IR Intelligent High-Speed Demo Installation and User Manual
Welcome
Thank you for purchasing IR intelligent high-speed dome.
This manual is used for operating and programming the unit as your reference. You can find
relevant information of functions and commands, as well as detailed menu tree and fast operating
instructions in this manual. The section of installation provides the needed information for setting and
installing the unit. Before installing and using the unit, please
read
the information in this manual
carefully.
1
Page 4
IR Intelligent High-Speed Dome Installation and User Manual
I Important Safeguards
This manual is the basic instruction about IR intelligent high-speed dome. This manual consists
of important information about security and warning, function specification, performance characteristic
and parameter, installation step, general faults and the
solution to get out of
them
, maintenance and others need to know when using the IR intelligent high-speed dome.
If you first use the IR intelligent high-speed dome or ever used the similar products, you had better
read this manual before using this unit.
If possible, please start reading from the first page in sequence. If you just hope to see the needed
parts, you also can select them from
catalogue
. Please refer page 27 to get the function list of the
unit. This unit uses special presets to realize some function operation.
Careful transportation
During the course of transportation and storage, the product should be avoided from incorrect
operations such as heavy pressing, strong vibration, soaking,,etc. which may cause damage to the unit.
This unit must adopt parts packing transportation
regardless of
delivery or return to factory
maintenance. The damage which caused by assemble packing transportation is not
covered by the
warranty.
Careful installation
During the
course of
installation, the product should be handled
properly
, and should be avoided from incorrect operations such as squeeze the structure parts, heavy press, strong vibration etc, which may cause mechanical problem and reflect the overall performance of the unit. The dome cover of the unit which belongs to advanced optical products should be avoided from incorrect operations such as directly touch by hand which may scratch the cover and affect image quality. When installed,
please follow all electrical standards for safety and adopt the
particular power supply which is provided with the unit. Control signal and video signal should be kept
enough distance from high voltage equipments and cables when they are in transmission, and
necessary steps should be taken to prevent lightning damage or power surge. Don’t turn on power
2
Page 5
IR Intelligent High-Speed Demo Installation and User Manual
before finish installation.
Don’t dismantle
Don’t dismantle the unit. There are no parts inside the unit which can be repaired by the users
themselves. When mechanical problems arise, do not be in a haste to do any repairing , please refer to
the user’s manual to find the trouble. If causes can not be located, please refer servicing to qualified
professionals. All servicing must be done by authorized personnel.
Set in place far from electric and magnetic fields
If the unit is set near EMI source such as television, wireless transmitter, electromagnetic device,
motors, transformers, speakers etc which may create electromagnetic field, the electromagnetic field will
influence images. Please keep sufficient distance.
Don't aim the camera at light objects
No matter the unit is running or not, the camera should never be aimed at the sun or object with
extremely bright light, and never be aimed at or monitor immobile light object for a long time. Otherwise,
the camera’s CCD might be permanently damaged.
Careful maintenance
The camera should be carefully used and avoided form impact or vibration, otherwise, it will be
damaged. Don't use strong or corrosive detergent to clean dome camera’s body. You should clean it
with dry cloth. When the dirt is not easy cleared, you can wipe it by neutral detergent. If the camera lens
is dirty, please wipe it by the special paper.
Please use this product in the required working environment:
Working Environment IR intelligent high-speed dome
Environmental Temperature -35~40
Environmental Humidity <95%
Atmospheric Pressure 86~106KPa
Power Supply AC24V/2.5 A
NOTE: Don’t install the indoor unit for outside. Please be sure the outdoor installation meet to
waterproof demand.
3
Page 6
IR Intelligent High-Speed Dome Installation and User Manual
II Installation Guide
2.1 Preparation for Installation
1. Basic demand
Before installing and using this unit, please read the following warning information:
1)
Installation and maintenance should be carried out by professional personnel as per relative
regulation. All electrical work must obey the latest electrical regulations, fire regulations and
relevant regulation. Check whether the accessories of the unit are complete according to
packing list and confirm the place whether the method of installation is correct in accord with
required, if not, please contact your supplier. Please use this product in required environment.
2)
Indoor IR intelligent high-speed dome only designs for house supply. It can’t be installed
exposed to rain or in very humid place.
3)
After re-installation or repair, you need to measure the resistance between the circuit and shell
to check whether the insulation is good, and ensure there is no short-circuit between the
circuit and shell.
4)
Confirm there is enough place to contain the product and its structure components. Confirm
the ceiling, wall and bracket for installation can take the total weight of the product and its
structure components, and materials used to support the weight can sustain four times the
weight of the product.
2. Cable preparation
1)
Select cables according to transmission distance: the minimum specification requirements of
vision coaxial-cable is as below:
75Ω impedance;
Copper wire;
95% braided copper mesh shielding.
4
Page 7
IR Intelligent High-Speed Demo Installation and User Manual
Domestic Model International Model Maximum distance (meters
RG59/U RG59/U 229m(750ft)
5C-2V RG6/U 305m(1000ft)
7C-2V RG11/U 457m(1500ft)
The same type of video cables may be different depending on manufacturer. The data shown in
above table is the transmission distance of general vision cable.
2) The following data is recommended maximum distance for application of 24VAC or 24VDC,
the distance is calculated from 10% voltage drop. (For AC or DC electric driving equipment,
the maximum allowable voltage drop is 10 %.)
Cable diameter
0.5mm²(20AW
1mm²(18AWG)
1.5mm²(16AW
2.5mm²(14AW
Power 23W 38m(123ft) 60m(196ft) 95m(311ft) 151m(495ft)
Power 72W 12m(39ft) 19m(62ft) 30m(98ft) 48m(156ft)
3. Toggle switch setting
Set the toggle switch according to the control protocol, baud rate and address. (Refer to the third
chapter<Description of Functional >)
2.2
Installation
A series of IR intelligent high-speed dome dimension figure
5
Page 8
IR Intelligent High-Speed Dome Installation and User Manual
B series of IR intelligent high-speed dome dimension figure
6
Page 9
IR Intelligent High-Speed Demo Installation and User Manual
C series of IR intelligent high-speed dome dimension figure
7
Page 10
IR Intelligent High-Speed Dome Installation and User Manual
E series of IR intelligent high-speed dome dimension figure
8
Page 11
IR Intelligent High-Speed Demo Installation and User Manual
IR intelligent high-speed dome is designed for wall mounted and pendent mounted installation
Conditions of wall mounted installation:
Wall mounted unit can be used in the rigid wall structure of indoor and outdoor.
1)
The wall thickness should be enough to install setscrews.
2)
The wall can withstand at least 4 times the weight of the unit.
Punch holes for wall mounted bracket
Take the wall mounted bracket from the packing box, and use the open holes at the bottom of
bracket as template and draw punch positions on the wall. (As shown in the following figure)
显示
对应的拉丁字符的拼音
9
Page 12
IR Intelligent High-Speed Dome Installation and User Manual
Punch holes and drive in four M8 setscrews. (As shown in the following figure)
Conditions of pendent mounted
installation:
Pendent mounted unit can be
used indoor in the rigid wall structure.
1)
The thickness of ceiling should be enough to install setscrews.
2)
The ceiling can withstand at least 4 times the weight of the unit.
Punch holes for pendent mounted bracket
Take the pendent mounted bracket from the packing box, and use open holes at the bottom of
bracket as template and draw punch positions on the ceiling. (As shown in the following figure)
示对应的拉丁字符的拼音
10
Page 13
IR Intelligent High-Speed Demo Installation and User Manual
Punch holes in punch positions and drive in four M6 setscrews. (As shown in the following figure)
A series of IR
intelligent high-speed
dome installation
11
Installation steps of wall mounted unit:
1) Take dome base from the packing box. Pull the wire and cables out through the bracket, and than aim at four open holes and fix the bracket firmly to the pre-installed setscrews with four M8 nuts. (As shown on the left)
2) Install the dome base onto the bracket.
3) Please refer the instruction to connect the power supply, video and controlling cables.
4) Take out IR dome body from the packing box. Setup communication protocol, baud rate and address through SW1 and SW2 at the bottom of the IR dome body. When install the IR dome body, IR dome body’s socket need to correspond with the dome base’s socket. Hold the camera with both hands, aim the IR dome body’s clip at the dome base’s bayonet (Note the corresponding red marks ), put the clip into bayonet slowly, and then press the top of clip with a little force, you can confirm the installation is set at positions after heard two crisp voice of a combined bump.
Note: Confirm the IR dome body was completely stuck, or else the IR dome body may cover off or the dome cover may be fretted. Pull down the IR dome body lightly to check whether the IR dome body is completely stuck.
5) Install demo cover onto demo base and fix them.
Installation steps of pendent mounted unit:
1) Take dome base from the packing box. Pull the wire and cables out through the bracket, and than aim at four open holes and fix the bracket firmly to the pre-installed setscrews with four M6 nuts .(As shown on the left)
2) Refer to the installation steps of wall mounted unit.
朗读
显示对应的拉丁字符的拼音
Page 14
IR Intelligent High-Speed Dome Installation and User Manual
12
Page 15
IR Intelligent High-Speed Demo Installation and User Manual
13
Page 16
IR Intelligent High-Speed Dome Installation and User Manual
14
Page 17
IR Intelligent High-Speed Demo Installation and User Manual
15
Page 18
IR Intelligent High-Speed Dome Installation and User Manual
B series of IR intelligent high-speed dome installation
16
Installation steps of wall mounted unit:
1) Take IR dome camera from packing box, set up dome camera protocol, baud rate and address. Pull the wire and cable out through the bracket, and then aim at four open holes on the bracket and fix the IR dome camera firmly to bracket with M6 socket head screws which are along with the unit.( As shown on the left)
2) Aim at four open holes on the wall and fix the bracket firmly to the pre-installed setscrews with four M8 nuts.
3) Please refer to the instruction to connect the power supply, video and controlling cables.
Installation steps of pendent mounted unit:
1) Take IR dome camera from the packing box, setup communication protocol, baud rate and address through SW1 and SW2 at the bottom of the IR dome camera. Pull the wire and cable out through the bracket, and then aim at four open holes on the bracket and fix the IR dome camera firmly to the bracket with M6 screws. (As shown on the left)
2) Aim at four open hole on the ceiling and fix the bracket firmly to the pre-installed setscrews with four M6 nuts
3) Please refer to the instruction to connect the power supply, video
and controlling cables.
Page 19
IR Intelligent High-Speed Demo Installation and User Manual
C series of IR intelligent high-speed dome installation
17
Installation steps of wall mounted unit:
1) Take dome base out from the packing box. Pull the wire and cable out through the bracket, fix the IR dome body firmly to the bracket with M6 socket head screws which are along with the unit.(As shown on the left)
2) Fix the bracket firmly onto the pre-installed setscrews on the wall with four M8 nuts.
3) Take out IR dome body from the packing box. Setup communication protocol, baud rate and address through SW1 and SW2 at the bottom of the dome body. When install the dome body, dome body’s socket need to correspond with the dome base’s socket. Hold the camera with both hands, aim the dome body’s clip at the dome base’s bayonet (Note the red marks correspond), put the clip into bayonet slowly, and then press the top of clip with a little force, you can confirm the installation is set at positions, after heard two crisp voice of a combined bump. Note: Confirm the dome body was completely stuck, or else the dome body may cover off or the dome cover may be fretted. Pull down the dome body lightly to check whether the dome body is completely stuck.
4) Install dome cover onto dome base and fix them
Installation steps of pendent mounted unit:
1)
Take dome base out from the packing box. Pull the wire and cable out through the bracket, and fix the IR dome base firmly to
the bracket with M6 screws. (As shown on the left)
2)
Aim at four open holes on the ceiling and fix the bracket firmly to the pre-installed setscrews on the ceiling with four M6 nuts.
3)
Refer to the installation steps of wall mounted unit.
朗读
Page 20
IR Intelligent High-Speed Dome Installation and User Manual
18
Page 21
IR Intelligent High-Speed Demo Installation and User Manual
E series of IR intelligent high-speed dome installation
19
Page 22
IR Intelligent High-Speed Dome Installation and User Manual
20
Installation steps of wall mounted unit:
1) Take IR dome body from the packing box. Set up
communication protocol, baud rate and address. Pull the wire
and cable out through the bracket, and then aim at four open
holes on the bracket and fix the IR dome camera firmly to
bracket with M6 socket head screws along with the unit.( As
shown on the left)
2) Aim at four open holes on the wall and fix the bracket firmly to
the pre-installed setscrews with four M8 nuts.
3) Please refer to the instruction to connect the power supply,
video and controlling cables.
Installation steps of pendent mounted unit:
1) Take out IR dome body from the packing box. Setup
communication protocol, baud rate and address through SW1
and SW2 at the bottom of the IR dome body. Pull the wire and
cable out through the bracket, and then aim at four installed
holes on the ceiling and fix the IR dome camera firmly to bracket
with M6 screws ( As shown on the left)
2) Aim at four installing hole on the ceiling and fix the bracket firmly
to the pre-installed setscrews with four M6 nuts.
3) Please refer to the instruction to connect the power supply, video
and controlling cables.
Page 23
IR Intelligent High-Speed Demo Installation and User Manual
Note: The pendent mounted bracket can not be used outside. Because of this specialized operation
condition, please ensure that this dome camera meet to the waterproof demand.
1)
The suspender which is used with the pendent mounted bracket must meet to waterproof demand.
Otherwise, the customer will be responsible for the water fault.
2)
It’s forbidden to pull the leading-out wire of the unit out through the Flange side hole of the pendent
mounted bracket.
3)
Make sure the sealing ring and Flange sunken hole of pendent mounted bracket are tightly
combined and sealed from water.
4)
Put silica gel around Flange of pendent mounted bracket to seal from water.
5)
Put silica gel around the connector of pendent sleeve and upper shield to seal from water.
6)
All exposed screw holes of pendent mounted bracket must be played silica gel to seal from water.
III Description of Functions
IR intelligent high-speed dome is equipped with high performance DSP camera with zooming lens,
21
Page 24
IR Intelligent High-Speed Dome Installation and User Manual
higher efficiency IR lamps, built-in PTZ and digital decoder, which represents the future trend of high
technology monitoring products. The unit is adopts full-digital control, flexible programming and
exquisitely simple transmission system design. The unit is capable of rapid positioning and
consecutively tracing and scanning, which realizes the real sense of all-directional and no blind spots
monitoring. The unit support PELCO - D, PELCO - P, TA01 and other communication protocol, makes
operation more flexible and simple.
The series of IR intelligent high-speed dome can be applied in every walk of life to monitor moving
objects in larger areas, such as monitoring banks, airports, transportation, state government agencies,
power, prisons, hotels, commercial buildings, factories, schools, museums etc.
3.1 Performance Characteristic
1.
Functions Introduce
Adopted full-functional high-performance DSP design, performance stable and reliable.
3D positioning function, realizes screen coordinate positioning and partial enlarges through
software.
Minimum hand-controlling speed of stable operation is 0.01 ° / S. Maximum patrolling speed of
precise positioning is 350 °/S.
Reserved network module interfaces can be loaded to network-
intelligent
camera.
Support and automatic identification PELCO-D, PELCO-P, TA01 and other communication
protocols.
No internally saved data lose when power off; In-build module contains surge immunity protection.
204 presets for free storage, precise positioning, and have preset screen freeze function.
Programmable automatic patrolling tracks, automatic linear scan function and guarding function.
Supports remote fault diagnosis, system upgrade, reset, and address setting function.
Automatically identify different camera modules, communication protocol and baud rate.
Optional Multi-language functions, and also achieves date, temperature, angle and compass
display.
Optional timing function.
2. Integrated high-speed PTZ
Integrated design ,
compact
structure, high reliability
Precise motor drive, infinite variable speed, steady operation, no jitter, sensitive control.
Achieve automatically flip 180º and consecutive monitoring vertically.
Low power consumption, calorific value is only half of the similar manufacturer’s products.
22
Page 25
IR Intelligent High-Speed Demo Installation and User Manual
3.
Built-in HD integrative camera
Auto iris, auto backlighting compensation.
Auto/manual white balance.
Auto / manual focus.
Automatic brightness control.
HD integrative camera.
Multiple zoom integrative cameras can be chosen.
4.
24-hour outdoor design
Built-in heaters, sensors intelligent control.
Built-in radiator fan, by which the unit can work at high temperature
ambient condition
60 .
The cover is constructed with all-alloy, which ensures strong and durable.
Built-in
multilevel
3000V lightning protection, surge protection and surges protection.
3.2 Function declaration
This section describes the principle of main functions' implementation, not involve specific method
of operation, different platforms have different operation methods, generally subject to operation manual
of manufacturers, there may be some special demand and operation methods in some cases, please
contact with the dealers to get necessary information.
Manual target tracking
Users can control the camera to trace the moving object or change the monitoring area by moving
the joystick on the keyboard up, down, left or right What's more, the angle of view or the size of the
image of the object can be changed by adjusting the focal length. In the default Auto-focus, Auto-Iris
state, the lens can automatically quickly adjust to get clear image according to the change of the object.
Auto flip
In the process of operating the joystick to trace and monitor, if the user move the lens to the bottom
(vertical) then continues pressing the joystick, the lens will automatically flip 180º horizontally, then the
user can still control it to move upwards till 90°, which enables the user to directly observe the situation
on the back side, thus fore-and-aft 180° consecutive monitoring can be realized.
Set and call preset
The presets function works in this way: The IR intelligent high-speed dome stores the data of PTZ
horizontal angle, tilt angle and lens focal-length
in the current state
. The user can quickly and
conveniently storage and call the preset by the keyboard and other control equipment, and then move
23
Page 26
IR Intelligent High-Speed Dome Installation and User Manual
the PTZ and camera module to the corresponding position.
Focal length/ speed automatic matching techniques
When the focus is long and in the mode of manual adjustment, due to the high sensitivity of the IR
intelligent high-speed dome, even the slightest movement of the joystick would make the image move
quickly, and cause image losses. Based on human design, the IR intelligent high-speed dome can
automatically adjust the horizontal and vertical moving speed according to the current focal-length,
which makes the manual target-tracing operation much easier.
Auto linear scan function
The auto linear scan function is a built-in function of the IR intelligent high-speed dome, which can
preset left/right border. The user can run the left/right scan directly through an external command, and
then the dome camera will automatically run horizontally between the left limiting position and the right
limiting position at the preset speed.
3D positioning function
In the effective zoom range of the unit, users can directly enlarge and narrow all area of screen
view and put any point in the view moved to center of the field.
Pattern (pattern scan)
The IR intelligent high-speed dome can continuously record running track for 600 seconds or 500
instructions, after start pattern, the unit can automatically cyclic scanning and monitoring according to
preset recorded trajectory.
Observe mode
Users can preset observe time and action mode of IR intelligent high-speed dome (call preset
number, auto linear scan function, auto patrol, patterns, memory recalling function once power off). If
users have no action within the setting time, the unit will automatically start up preset action.
Menu function
The menu can satisfy different customers' requirement by support Chinese and English full screen
operation. The menu can be made to other langue according to customer’s demand.
Clock function
Users can set different action in different time which can realize seven days a week, eight periods a
day automatic setting function.
Azimuth function
Users can set up north direction to realize the precise display of rotation direction. IR intelligent
high-speed dome also supports zone indication. When the unit is turned to a preset area, the screen
24
Page 27
IR Intelligent High-Speed Demo Installation and User Manual
can show the title of the preset area.
Privacy Mask function
For the privacy and safety area, some black lumps can be set to privacy zones. The size and
position of the black lumps can be adjustable. Altogether 24 privacy zones can be set in the unit. (This
function needs support of the camera)
Set address
This IR intelligent high-peed dome support 255 addresses, the unit only responds to the command
of its own address or broadcast address. The address can be set by toggle switch or soft address
function.
Camera control
1)
Zoom control
Users can adjust the zoom by controlling the keyboard to get panoramic view or close view.
2) Focus control
System default is automatic focus. While the lens moves, the camera module can automatically
focus on the center of the object view to get clear image. In special conditions, users can manually
adjust the focus to achieve desired image effect.
3) Auto iris control
The iris can automatically influence the change of ambient light and make quickly adjustment to
output image of stable brightness.
4) Automatic backlight compensation
When the backlight compensation function is turned on, in extremely bright background, the camera
module can compensate the brightness of the relatively dark objects, at the same time adjust the light of
the bright background, avoiding that the whole image is too bright to watch due to the too high
brightness of the background, while the object is too dark to be distinguished, so that clear image can
be got. The system closed this function as the default.
5) Auto / manual white balance
According to the ambient light, automatically or manually adjust the light to reappear the real color.
6)
IR cut filter (only for cameras with color and black-and-white conversion function )
The camera with night vision function will automatically switch CCD illumination according to the
ambient light in auto IR cut filter mode. For example: During the day the light is enough, the camera can
use general illumination to get brightly colored picture, while in night, the camera can automatically
change low illumination to get clear object with black and white picture.
25
Page 28
IR Intelligent High-Speed Dome Installation and User Manual
Users can set IR cut filter to manual by the keyboard, in this case, the camera can not
automatically make corresponding conversion according to ambient light. Users can manually select
color or black-and-white pictures shown.
Set toggle switches
Before installing the IR intelligent high-speed dome, please configure protocol, baud rate and
address code. (The factory default automatic identification protocol & baud rate is address code 1)
SW1 Protocol & baud rate toggle
switch SW2 address
code toggle switch
Part of the Data-chosen-switches protocol & baud rate:
Auto identification protocol & baud
rate PELCO-D&2400BPS
PELCO-P&9600BPS
1) Protocol setting
Protocol
SW1-1
SW1-2
SW1-3
Auto identification or PELCO-D
OFF
OFF
OFF
PELCO-P
ON
OFF
OFF
DaHua / GA
ON
OFF
ON
HIK
ONONOFF
Reserve
………………
2) Baud rate setting
Baud rate
SW1-4
SW1-5
Auto identification or 1200bps
OFF
OFF
2400bps
ON
OFF
4800bps
OFF
ON
9600bps
ON
ON
26
Page 29
IR Intelligent High-Speed Demo Installation and User Manual
3)
Address setting
SW2 toggle switch used to set address of the unit. Address sitting is used binary system, the eighth
bit is the highest bit, and the first bit is the lowest bit. The broadcast address is 0, which means if only
the address of control port is 0, the units which have suited for protocol and baud rate can be controlled.
The following is the protocol address coding table of PELCO - D/TA01:
SW2 PELCO-D address code setting
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF2OFFONOFF
OFF
OFF
OFF
OFF
OFF
3
ONONOFF
OFF
OFF
OFF
OFF
OFF
4
OFF
OFFONOFF
OFF
OFF
OFF
OFF
5
ON
OFFONOFF
OFF
OFF
OFF
OFF
6
OFFONON
OFF
OFF
OFF
OFF
OFF7ONONON
OFF
OFF
OFF
OFF
OFF8OFF
OFF
OFFONOFF
OFF
OFF
OFF9ON
OFF
OFFONOFF
OFF
OFF
OFF10OFFONOFFONOFF
OFF
OFF
OFF11ONONOFFONOFF
OFF
OFF
OFF12OFF
OFFONON
OFF
OFF
OFF
OFF
13
ON
OFFONON
OFF
OFF
OFF
OFF
14
OFFONONONOFF
OFF
OFF
OFF
15
ONONONONOFF
OFF
OFF
OFF
16
OFF
OFF
OFF
OFFONOFF
OFF
OFF17ON
OFF
OFF
OFFONOFF
OFF
OFF18OFFONOFF
OFFONOFF
OFF
OFF19ONONOFF
OFFONOFF
OFF
OFF
20
OFF
OFFONOFFONOFF
OFF
OFF
21
ON
OFFONOFFONOFF
OFF
OFF22OFFONON
OFFONOFF
OFF
OFF
23
ONONON
OFFONOFF
OFF
OFF
24
OFF
OFF
OFFONON
OFF
OFF
OFF25ON
OFF
OFFONON
OFF
OFF
OFF26OFFONOFFONON
OFF
OFF
OFF27ONONOFFONON
OFF
OFF
OFF
27
Page 30
IR Intelligent High-Speed Dome Installation and User Manual
28
OFF
OFFONONONOFF
OFF
OFF
29
ON
OFFONONONOFF
OFF
OFF
30
OFFONONONON
OFF
OFF
OFF31ONONONONON
OFF
OFF
OFF32OFF
OFF
OFF
OFF
OFFONOFF
OFF
SW2 PELCO-D address code setting (continued)
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
33
ON
OFF
OFF
OFF
OFFONOFF
OFF34OFFONOFF
OFF
OFFONOFF
OFF35ONONOFF
OFF
OFFONOFF
OFF
36
OFF
OFFONOFF
OFFONOFF
OFF
37
ON
OFFONOFF
OFFONOFF
OFF
38
OFFONON
OFF
OFFONOFF
OFF
39
ONONON
OFF
OFFONOFF
OFF40OFF
OFF
OFFONOFFONOFF
OFF
41
ON
OFF
OFFONOFFONOFF
OFF
42
OFFONOFFONOFFONOFF
OFF43ONONOFFONOFFONOFF
OFF44OFF
OFFONON
OFFONOFF
OFF45ON
OFFONON
OFFONOFF
OFF
46
OFFONONONOFFONOFF
OFF
47
ONONONONOFFONOFF
OFF
48
OFF
OFF
OFF
OFF
ONONOFF
OFF
49
ON
OFF
OFF
OFF
ONONOFF
OFF50OFFONOFF
OFF
ONONOFF
OFF51ONONOFF
OFF
ONONOFF
OFF52OFF
OFFONOFF
ONONOFF
OFF53ON
OFFONOFF
ONONOFF
OFF54OFFONON
OFF
ONONOFF
OFF55ONONON
OFF
ONONOFF
OFF56OFF
OFF
OFFONONONOFF
OFF57ON
OFF
OFFONONONOFF
OFF
58
OFFONOFFONONONOFF
OFF
28
Page 31
IR Intelligent High-Speed Demo Installation and User Manual
59
ONONOFFONONONOFF
OFF60OFF
OFFONON
ONONOFF
OFF61ON
OFFONON
ONONOFF
OFF
62
OFFONONONONONOFF
OFF
63
ONONONONONONOFF
OFF64OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
SW2 PELCO-D address code setting (continued)
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
65
ON
OFF
OFF
OFF
OFF
OFFONOFF
66
OFFONOFF
OFF
OFF
OFFONOFF
67
ONONOFF
OFF
OFF
OFFONOFF68OFF
OFFONOFF
OFF
OFFONOFF69ON
OFFONOFF
OFF
OFFONOFF70OFFONON
OFF
OFF
OFFONOFF
71
ONONON
OFF
OFF
OFFONOFF
72
OFF
OFF
OFFONOFF
OFFONOFF
73
ON
OFF
OFFONOFF
OFFONOFF
74
OFFONOFFONOFF
OFFONOFF75ONONOFFONOFF
OFFONOFF76OFF
OFFONON
OFF
OFFONOFF77ON
OFFONON
OFF
OFFONOFF78OFFONONONOFF
OFFONOFF79ONONONONOFF
OFFONOFF80OFF
OFF
OFF
OFFONOFFONOFF
81
ON
OFF
OFF
OFFONOFFONOFF
82
OFFONOFF
OFFONOFFONOFF
83
ONONOFF
OFFONOFFONOFF
84
OFF
OFFONOFFONOFFONOFF85ON
OFFONOFFONOFFONOFF
86
OFFONON
OFFONOFFONOFF
87
ONONON
OFFONOFFONOFF88OFF
OFF
OFFONON
OFFONOFF89ON
OFF
OFFONON
OFFONOFF90OFFONOFFONON
OFFONOFF
29
Page 32
IR Intelligent High-Speed Dome Installation and User Manual
91
ONONOFFONON
OFFONOFF92OFF
OFFONONONOFFONOFF93ON
OFFONONONOFFONOFF
94
OFFONONONON
OFFONOFF
95
ONONONONON
OFFONOFF96OFF
OFF
OFF
OFF
OFF
ONONOFF
SW2 PELCO-D address code setting (continued)
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
97
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
98
OFFONOFF
OFF
OFF
ON
ON
OFF
99
ONONOFF
OFF
OFF
ON
ON
OFF
100
OFF
OFFONOFF
OFF
ON
ON
OFF
101
ON
OFFONOFF
OFF
ON
ON
OFF
102
OFFONON
OFF
OFF
ON
ON
OFF
103
ONONON
OFF
OFF
ON
ON
OFF
104
OFF
OFF
OFFONOFF
ON
ON
OFF
105
ON
OFF
OFFONOFF
ON
ON
OFF
106
OFFONOFFONOFF
ON
ON
OFF
107
ONONOFFONOFF
ON
ON
OFF
108
OFF
OFFONON
OFF
ON
ON
OFF
109
ON
OFFONON
OFF
ON
ON
OFF
110
OFFONONONOFF
ON
ON
OFF
111
ONONONONOFF
ON
ON
OFF
112
OFF
OFF
OFF
OFF
ON
ON
ON
OFF
113
ON
OFF
OFF
OFF
ON
ON
ON
OFF
114
OFFONOFF
OFF
ON
ON
ON
OFF
115
ONONOFF
OFF
ON
ON
ON
OFF
116
OFF
OFFONOFF
ON
ON
ON
OFF
117
ON
OFFONOFF
ON
ON
ON
OFF
118
OFFONON
OFF
ON
ON
ON
OFF
119
ONONON
OFF
ON
ON
ON
OFF
120
OFF
OFF
OFFONON
ON
ON
OFF
121
ON
OFF
OFFONON
ON
ON
OFF
122
OFFONOFFONON
ON
ON
OFF
30
Page 33
IR Intelligent High-Speed Demo Installation and User Manual
123
ONONOFFONON
ON
ON
OFF
124
OFF
OFFONON
ON
ON
ON
OFF
125
ON
OFFONON
ON
ON
ON
OFF
126
OFFONONONON
ON
ON
OFF
127
ONONONONON
ON
ON
OFF
128
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
SW2 PELCO-D address code setting (continued)
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
129
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON
130
OFFONOFF
OFF
OFF
OFF
OFF
ON
131
ONONOFF
OFF
OFF
OFF
OFF
ON
132
OFF
OFFONOFF
OFF
OFF
OFF
ON
133
ON
OFFONOFF
OFF
OFF
OFF
ON
134
OFFONON
OFF
OFF
OFF
OFF
ON
135
ONONON
OFF
OFF
OFF
OFF
ON
136
OFF
OFF
OFFONOFF
OFF
OFF
ON
137
ON
OFF
OFFONOFF
OFF
OFF
ON
138
OFFONOFFONOFF
OFF
OFF
ON
139
ONONOFFONOFF
OFF
OFF
ON
140
OFF
OFFONON
OFF
OFF
OFF
ON
141
ON
OFFONON
OFF
OFF
OFF
ON
142
OFFONONONOFF
OFF
OFF
ON
143
ONONONONOFF
OFF
OFF
ON
144
OFF
OFF
OFF
OFFONOFF
OFF
ON
145
ON
OFF
OFF
OFFONOFF
OFF
ON
146
OFFONOFF
OFFONOFF
OFF
ON
147
ONONOFF
OFFONOFF
OFF
ON
148
OFF
OFFONOFFONOFF
OFF
ON
149
ON
OFFONOFFONOFF
OFF
ON
150
OFFONON
OFFONOFF
OFF
ON
151
ONONON
OFFONOFF
OFF
ON
152
OFF
OFF
OFFONON
OFF
OFF
ON
153
ON
OFF
OFFONON
OFF
OFF
ON
154
OFFONOFFONON
OFF
OFF
ON
31
Page 34
IR Intelligent High-Speed Dome Installation and User Manual
155
ONONOFFONON
OFF
OFF
ON
156
OFF
OFFONONONOFF
OFF
ON
157
ON
OFFONONONOFF
OFF
ON
158
OFFONONONON
OFF
OFF
ON
159
ONONONONON
OFF
OFF
ON
160
OFF
OFF
OFF
OFF
OFFONOFF
ON
SW2 PELCO-D address code setting
(continued)
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
161
ON
OFF
OFF
OFF
OFFONOFF
ON
162
OFFONOFF
OFF
OFFONOFF
ON
163
ONONOFF
OFF
OFFONOFF
ON
164
OFF
OFFONOFF
OFFONOFF
ON
165
ON
OFFONOFF
OFFONOFF
ON
166
OFFONON
OFF
OFFONOFF
ON
167
ONONON
OFF
OFFONOFF
ON
168
OFF
OFF
OFFONOFFONOFF
ON
169
ON
OFF
OFFONOFFONOFF
ON
170
OFFONOFFONOFFONOFF
ON
171
ONONOFFONOFFONOFF
ON
172
OFF
OFFONON
OFFONOFF
ON
173
ON
OFFONON
OFFONOFF
ON
174
OFFONONONOFFONOFF
ON
175
ONONONONOFFONOFF
ON
176
OFF
OFF
OFF
OFF
ONONOFF
ON
177
ON
OFF
OFF
OFF
ONONOFF
ON
178
OFFONOFF
OFF
ONONOFF
ON
179
ONONOFF
OFF
ONONOFF
ON
180
OFF
OFFONOFF
ONONOFF
ON
181
ON
OFFONOFF
ONONOFF
ON
182
OFFONON
OFF
ONONOFF
ON
183
ONONON
OFF
ONONOFF
ON
184
OFF
OFF
OFFONONONOFF
ON
185
ON
OFF
OFFONONONOFF
ON
186
OFFONOFFONONONOFF
ON
32
Page 35
IR Intelligent High-Speed Demo Installation and User Manual
187
ONONOFFONONONOFF
ON
188
OFF
OFFONON
ONONOFF
ON
189
ON
OFFONON
ONONOFF
ON
190
OFFONONONONONOFF
ON
191
ONONONONONONOFF
ON
192
OFF
OFF
OFF
OFF
OFF
OFFONON
SW2 PELCO-D address code setting
(continued)
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
193
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
194
OFFONOFF
OFF
OFF
OFF
ON
ON
195
ONONOFF
OFF
OFF
OFF
ONON196
OFF
OFFONOFF
OFF
OFF
ONON197
ON
OFFONOFF
OFF
OFF
ONON198
OFFONON
OFF
OFF
OFF
ON
ON
199
ONONON
OFF
OFF
OFF
ON
ON
200
OFF
OFF
OFFONOFF
OFF
ON
ON
201
ON
OFF
OFFONOFF
OFF
ON
ON
202
OFFONOFFONOFF
OFF
ONON203
ONONOFFONOFF
OFF
ONON204
OFF
OFFONON
OFF
OFF
ONON205
ON
OFFONON
OFF
OFF
ONON206
OFFONONONOFF
OFF
ONON207
ONONONONOFF
OFF
ONON208
OFF
OFF
OFF
OFFONOFF
ON
ON
209
ON
OFF
OFF
OFFONOFF
ON
ON
210
OFFONOFF
OFFONOFF
ON
ON
211
ONONOFF
OFFONOFF
ON
ON
212
OFF
OFFONOFFONOFF
ONON213
ON
OFFONOFFONOFF
ON
ON
214
OFFONON
OFFONOFF
ON
ON
215
ONONON
OFFONOFF
ONON216
OFF
OFF
OFFONON
OFF
ONON217
ON
OFF
OFFONON
OFF
ONON218
OFFONOFFONON
OFF
ON
ON
33
Page 36
IR Intelligent High-Speed Dome Installation and User Manual
219
ONONOFFONON
OFF
ONON220
OFF
OFFONONONOFF
ONON221
ON
OFFONONONOFF
ON
ON
222
OFFONONONON
OFF
ON
ON
223
ONONONONON
OFF
ONON224
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
SW2 PELCO-D address code setting
(continued)
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
225
ON
OFF
OFF
OFF
OFF
ONONON
226
OFFONOFF
OFF
OFF
ONONON
227
ONONOFF
OFF
OFF
ONONON
228
OFF
OFFONOFF
OFF
ONONON
229
ON
OFFONOFF
OFF
ONONON
230
OFFONON
OFF
OFF
ONONON
231
ONONON
OFF
OFF
ONONON
232
OFF
OFF
OFFONOFF
ONONON
233
ON
OFF
OFFONOFF
ONONON
234
OFFONOFFONOFF
ONONON
235
ONONOFFONOFF
ONONON
236
OFF
OFFONON
OFF
ONONON
237
ON
OFFONON
OFF
ONONON
238
OFFONONONOFF
ONONON
239
ONONONONOFF
ONONON
240
OFF
OFF
OFF
OFF
ON
ONONON
241
ON
OFF
OFF
OFF
ON
ONONON
242
OFFONOFF
OFF
ON
ONONON
243
ONONOFF
OFF
ON
ONONON
244
OFF
OFFONOFF
ON
ONONON
245
ON
OFFONOFF
ON
ONONON
246
OFFONON
OFF
ON
ONONON
247
ONONON
OFF
ON
ONONON
248
OFF
OFF
OFFONON
ONONON
249
ON
OFF
OFFONON
ONONON
250
OFFONOFFONON
ONONON
34
Page 37
IR Intelligent High-Speed Demo Installation and User Manual
251
ONONOFFONON
ONONON
252
OFF
OFFONON
ON
ONONON
253
ON
OFFONON
ON
ONONON
254
OFFONONONON
ONONON
255
ONONONONON
ONONON
The following is PELCO-P protocol address coding table:
SW2 PELCO-P address code setting
Address code
SW2-1
SW2-2
SW2-3
SW2-4
SW2-5
SW2-6
SW2-7
SW2-8
1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
2
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
3
OFFONOFF
OFF
OFF
OFF
OFF
OFF4ONONOFF
OFF
OFF
OFF
OFF
OFF5OFF
OFFONOFF
OFF
OFF
OFF
OFF6ON
OFFONOFF
OFF
OFF
OFF
OFF7OFFONON
OFF
OFF
OFF
OFF
OFF8ONONON
OFF
OFF
OFF
OFF
OFF9OFF
OFF
OFFONOFF
OFF
OFF
OFF
10
ON
OFF
OFFONOFF
OFF
OFF
OFF
11
OFFONOFFONOFF
OFF
OFF
OFF
12
ONONOFFONOFF
OFF
OFF
OFF
13
OFF
OFFONON
OFF
OFF
OFF
OFF14ON
OFFONON
OFF
OFF
OFF
OFF
15
OFFONONONOFF
OFF
OFF
OFF
16
ONONONONOFF
OFF
OFF
OFF17OFF
OFF
OFF
OFFONOFF
OFF
OFF18ON
OFF
OFF
OFFONOFF
OFF
OFF19OFFONOFF
OFFONOFF
OFF
OFF
20
ONONOFF
OFFONOFF
OFF
OFF
21
OFF
OFFONOFFONOFF
OFF
OFF
22
ON
OFFONOFFONOFF
OFF
OFF
23
OFFONON
OFFONOFF
OFF
OFF24ONONON
OFFONOFF
OFF
OFF
35
Page 38
IR Intelligent High-Speed Dome Installation and User Manual
25
OFF
OFF
OFFONON
OFF
OFF
OFF26ON
OFF
OFFONON
OFF
OFF
OFF27OFFONOFFONON
OFF
OFF
OFF
28
ONONOFFONON
OFF
OFF
OFF
29
OFF
OFFONONONOFF
OFF
OFF30ON
OFFONONONOFF
OFF
OFF
31
OFFONONONON
OFF
OFF
OFF
32
ONONONONON
OFF
OFF
OFF
IV
Technical parameter
Parameter Index
IR Illumination Distance
Options :30 meters,60 meters,80 meters,120 meters,150 meters etc.
IR LED control
Automatically switch far/near IR lamp according to focal length at night
Power Supply
AC24V±10%(Default) or DC12V±10%
Power Consumption
Maximum: 60W
Working Temperature
-30~ 55
Manual Rotary Speed
Horizontal
:0.05 ~ 240º/s;
Vertical
:0.03º ~ 160º/s
Horizontal Rotary Range
Horizontal 0º ~ 360º unlimited consecutive rotation
Vertical Rotary Range
Vertical -2º ~ 92º With auto flip
Control Mode RS485 bus-mastering, support full automatic identify protocol and baud
rate
3D Positioning
Realize screen coordinate positioning and local enlarge by software
Auto Patrol
9 groups, the
park
time of preset is adjustable
Auto Linear Scan
No less than 20 groups, patrol speed and park time can be adjusted
Proportional Reduce Speed
Support intelligent focal length / speed automatic matching technique
Remote Help
Remote fault diagnosis, system upgrade, reset function
Soft Address
Set address without dismantling the unit according to demand
Patterns
4 paths, record no more than 500 instructions or 10 minutes
Power Up Action
Support 18 kinds of power up action
Observe Action
Support 18 kinds of observe action
Camera
Compatible with most integrated camera (customizable specific protocol)
36
Page 39
IR Intelligent High-Speed Demo Installation and User Manual
Preset Freeze Frame
Realize freeze frame during preset calling (need camera support)
Menu
Chinese & English ,NTSC/PAL automatic identification output(optional)
Clock
Timing automatically start special function(optional)
Lightning Protection Voltage of power interface is 4kV,voltage of communication and video
interface is 3KV, 3-level surge protection
Shell
Aluminum case, Acid rain-proof ,High hardness
Protection Grade
Meet IP66 FCC CE and pass the Chinese MPS test
Installation
Kinds of installation type, Select one according to application environment
The above specifications are subject to change
without prior notice
V
Functional Instructions
5.1 Common function quick instruction list
The unit has 204 presets. Preset 1-48 and 100-255 for effective presets, and 49-99 for common
function quick command, users can quickly use the common function by calling or setting these
particular preset numbers.
Num Call presets Set presets Remarks
50
Start pattern 1
Program pattern 1
Pattern function
51
Start preset patrol 1
Set park time of patrol 1>> *
Patrol between preset 1-16
52
Start preset patrol 2
Set park time of patrol 2>>*
Patrol between preset 17-32
53
Start preset patrol 3
Set park time of patrol 2>> *
Patrol between preset 33-48
60
Turn on camera menu
Need camera support
61
Turn off
display
Turn on display
Characters display on
62
Turn off reduce speed
Turn on
reduce speed
63
Start horizontally auto scan
Turn on/off auto flip
65
Horizontally auto scan >>*
66
Horizontally linear scan >>*
Set scan speed>>>**
70
Turn off
privacy mask
Turn on privacy mask
71
Delete all presets
72
Turn off expert mode
Turn on expert mode
Default is OFF
73
Turn off
alarm
Turn on alarm
79
Restore factory defaults
37
Page 40
IR Intelligent High-Speed Dome Installation and User Manual
80
Set observe time >>*
Set observe action >>*
81
Set power up action >>*
87
Set azimuth zero position
89
Reboot system
91
Normal mounting
Inverted mounting
95
Turn on menu
96
Stop scanning
97
Start pattern
Start pattern 1
98
Start auto patrol
Start auto patrol 1
99
Start auto scan
Start auto scan 1
*: >> express that this command needs second-level call (set) preset, namely, it needs to call (set) the
two presets continuously .
**: >>> express that this command need third-level call(set) preset, namely, it needs to call (set) three
presets continuously.
: Only can be used when express mode is ON.
e.g., " call (set) 53 + call (set)3" means that you need to continuously call (set) preset 53 and then call
preset 3 within 15 seconds when the unit is in readiness, the followings are similar.
Time corresponding preset table:
Time Preset 1 2 3 4 5 6 7
Time 1SEC 3 SECS 6 SECS 15 SECS 30 SECS 1 MIN 5 MINS
Time Preset 8 9 10 11 12 13 14
Time 15 MINS 30 MINS 1 HOUR 8 HOURS 12 HOURS 24 HOURS reserve
Action corresponding preset table:
Action Preset
Action
1
No action
29
Preset 1 to preset 8
1011
Preset patrol1 and 2
1213
Horizontal linear scan 1 and 2
1415
Auto scan1 and 5
1617
Pattern 1 and 2
18
Auto tracking
38
Page 41
IR Intelligent High-Speed Demo Installation and User Manual
Patterns
1)
Program pattern: Set preset 50 to enter into program pattern, and then operate the unit such
as move left, right, up or down, zoom or call preset. When the program is complete, press
<IRIS OPEN> to exit.
2)
Start pattern: To start scanning the 1st pattern, call preset 50(or 97).
Preset patrol
1)
Set preset: Set the corresponding preset.
2)
Set patrol time: Set patrol number + time preset, e.g. set patrol 1's time to 15 seconds,
operation: set preset 51 and then set preset 4.
3)
Start patrol: Call the corresponding patrol number to start patrol, e.g. call preset 51 to start
patrol 1 between preset 1 and preset 16.
Camera menu
Call preset 60 to open camera menu (this function needs camera to support), and then select menu
item by zooming in (TELE) and zooming out (WIDE), modify selected value by focusing far (FAR) and
focusing near (NEAR), modify or open submenu by opening iris open (OPEN). (The above operations
are the common camera operations, the specific operations should be referred to the present using
camera).
Camera Display
1)
Close display: Call preset 61 to close all characters shown on screen.
2)
Open display: Set preset 61 to display often-used items on screen.
Often-used items include:
Display angles and compass function (need OSD module support)
Zoom display
Preset indicate
Horizontally auto scan
1) Start auto scan: Call preset 65+ call scan number
Scan number
12345
clockwise
Scan speed
1 level
2 level
3 level
4 level
5 level
Scan number
678910
Scan speed
6 level
7 level
8 level
9 level
10 level
39
Page 42
IR Intelligent High-Speed Dome Installation and User Manual
Scan number
1112131415
anticlockwis
e
Scan speed
1 level
2 level
3 level
4 level
5 level
Scan number
1617181920
Scan speed
6 level
7 level
8 level
9 level
10 level
E.g. Call preset 65 and preset 1 to start auto scan 1.
Note: The more level, the higher speed.
Horizontal linear scan
1)
The method to set speed of linear scan: Set preset 66 and set preset scan(table 1) and set
preset scan speed (table 2)
Table 1:
Linear scan preset
12345
AB
directi
on
Preset
1121
1222
1323
1424
1525
Linear scan preset
678910
Preset
1626
1727
1828
1929
2030
Linear scan preset
1112131415
BA
directi
on
Preset
2111
2212
2313
2414
2515
Preset scan
16171819 20
Preset
2616
2717
2818
2919
3020
Table 2:
Scan speed preset
123
Scan speed
low
medium
high
E.g. Set preset 66 and set linear scan preset 1 and set scan speed preset 3 to set the first horizontal
linear scan speed to high .
Expert mode
In order to avoid users operate special functions of presets, these special functions have been
blocked in factory default setting .if users need to use these functions, please open Expert mode.
Operation method:
40
Page 43
IR Intelligent High-Speed Demo Installation and User Manual
1)
Open Expert mode: Set preset 72 to open Expert mode.
2)
Close Expert mode: Call preset 72 to close Expert mode.
Open and close Expert model only need one time to take effect immediately. The state of expert
model will be saved even power off, before you change Expert mode next time, you don't need to open
Expert mode every time when you operate the special functions.
The items within common commands table only can be operated when expert mode is open. if
you need to restart the unit and the expert mode is already open, please directly call preset 89 to restart
the unit, if the expert mode is close, set preset 72 to open expert mode firstly and then call preset 89 to
restart the unit.
Delete all presets
Users can quickly delete all presets with one-key. Operation method: Call preset 71 to delete all
presets.
.
Restore factory defaults
The restore factory defaults function can restore all operations to factory defaults. Operation
method: Call preset 79 to restore all settings to factory defaults.
Azimuth zero position (system default is low position)
This function can adjust azimuth zero position. Operation method: Call preset 87 and then call the
corresponding azimuth zero preset.
High azimuth zero position means the unit can monitor farther view under normally installation.
Azimuth zero preset
123
Azimuth zero position
High
Medium
Low
Observe action
Set observe time: Set preset 80 and then set time preset to set observe time (system default is 30
seconds).
Time preset 1 2 3 4 5 6 7
Time
---
---
---
15 secs
30 secs
1 min
5 mins
Time preset
891011121314
Time
15 mins
30 mins
1hour
8 hours
12 hours
24 hours
reserve
Set observe action: Set preset 80 and then set action preset to set observe action (system default
is no action).
41
Page 44
IR Intelligent High-Speed Dome Installation and User Manual
E.g. set observe action to preset patrol 1. Operation: set preset 80 and then set action preset 10.
Power up action (system default is call preset 1).
Set power up action: Set preset 81 and then set action preset.
E.g. set power up action to set preset 1. Operation: set preset 81 and then set action preset 2.
Reboot system
The unit allows user to reboot the system remotely by a special command. Operation method: call
preset 89 to reboot the system.
Automatically identify camera
Operation: Call preset 49 and then call preset 17 to select automatically identify cameras mode.
IR LED
Operation: call preset 49 and then call preset N. Firstly call preset 49 to enter into function selected
mode, and then call corresponding preset N in the following table to start the corresponding function. It
must be coherent when call these two presets. If action between these two calls is not calling a preset,
this operation is invalid. You need to call preset 49 again to enter the function selected mode.
N
Functional Description
Remark
1
Switch sensitivity of IR LED to high
The higher the IR
sensitivity, the easier to
switch to IR black-and-
2
Switch sensitivity of IR LED to medium *
3
Switch sensitivity of IR LED to low
7
Manually compulsorily enable IR LED
Operation of IR LED
8
Manually compulsorily disable IR LED
9
Automatically enable IR LED*.
50
Automatically enable the brightness of IR LED*
Control brightness of IR
LED
57
Manually set IR LED to low brightness
59
Manually set IR LED to high brightness
*: the function is system default.
42
Page 45
IR Intelligent High-Speed Demo Installation and User Manual
5.2 Menu operation guide
(The following menu for products with OSD model)
Menu
item meaning:
: Currently selected menu item.
[Menu item
]
: The menu item has submenu.
43
Page 46
IR Intelligent High-Speed Dome Installation and User Manual
Menu item> : This menu item can operate after pressing IRIS OPEN button.
Menu item : This menu value can be modified by move the joystick to left or right
Back> : Return to the previous menu.
Exit> : Exit the menu.
Access the main menu (call preset 95)
You can call preset 95 to open the main menu on the monitor.
44
Page 47
IR Intelligent High-Speed Demo Installation and User Manual
45
Page 48
IR Intelligent High-Speed Dome Installation and User Manual
System Information
Display
Setting
46
Display settings menu is used in set display mode of show items
on the monitor. The following is usable items:
TITLE TEXT Indicate the name of dome camera
PRESET LABEL Indicate preset bits
DATE/TIME Show current date and time
AZIMUTH Show Horizontal and vertical angle
ZONE LABEL Indicate zone
ALARM MESSAGE Show Alarm information
TEMPERATURE Inner temperature of the unit
ZOOM Show Camera zoom
Setting options include:
OFF Close display item
CONTINUANCE Continuous display after activated.
1 SEC Show 1 second after activated
3 SECS Show 3 seconds after activated
6 SECS Show 6 seconds after activated
15 SECS Show 15 seconds after activated
The method to set display state: Move cursor to the required
position, select display state by moving joystick to left or right.
Labels can be placed anywhere on the monitor. This function is
used to set user-defined interface. The following positions of the
display items can be adjusted:
TITLE TEXT
PRESET LABEL
DATE/TIME
AZIMUTH
ZONE LABEL
ALARM MESSAGE
TEMPERATURE
ZOOM
The method to adjust the label position: move the cursor to
"DISPLAY SETTING", and press <IRIS OPEN> to enter the menu of
"LABEL POSITION", and then users can adjust to proper position by
moving the joystick to left, right, up or down. (Note: different label
positions can’t overlap, otherwise, the characters on the screen will
be covered), press <IRIS OPEN> after adjustment. Move the cursor
to “RETURN” or “EXIT”, and press < IRIS OPEN > to save setting
and return to previous menu or exit menu.
Users can check system information through the menu of the IR intelligent high-speed dome, system information includes: the version of the unit, protocol of the unit, communication speed, address of the unit, serial number of the unit, system date, title of the unit, temperature of the unit, language system, temperature unit etc.
Check system information as follows:
Move the cursor to "SYSTEM INFORMATION", and press< IRIS OPEN> enter system information menu and check system information. The system support Fahrenheit and Celsius, and the default temperature is Celsius. The method to change the temperature unit: move the cursor to "TEMPERATURE UNIT" and select unit by moving the joystick to left or right.
Page 49
IR Intelligent High-Speed Demo Installation and User Manual
Camera
Setting
47
The unit allows users to adjust parameters of camera from the menu, the method to set parameters’ specific meanings and settings are as follows (this function needs support by camera):
1. FOCUS (System default is AUTO)
Focus function allows lens keeps focus during using magnified, contractible and mobile function. If focus is set to "AUTO ", camera will auto focus when the unit rotates and zooms. If focus mode is set to "MANUAL ", then adjust focus manually. Press <FAR> or <NEAR> button on the keyboard to adjust focal length. If focus is set to "Once ", focus only once after zoomed, and no focus next time unless reset focus.
Focus mode includes: AUTO, MANUAL and ONCE. Setting method: move the cursor to "FOCUS", and select options by moving the joystick to left or right.
2. DIGITAL ZOOM (System default is OFF)
Close or open the camera digital zoom function from the menu. Setting method: move the cursor to "DIGITAL ZOOM", and then select ON or OFF by moving the joystick to left or right.
3. BACKLIGHT COMP (System default is OFF)
The backlight compensation is that when the brightness of the image center is relative low, you can open backlight compensation function to improve the brightness of the image. You can open or close the backlight compensation function from the menu. Setting method: move cursor to "BACKLIGHT COMP", and select ON or OFF by moving the joystick to left or right.
4. IR CUT FILTER(System default is AUTO)
Set color of the camera from the menu, options: AUTO, COLOR, B&W. Setting method: move the cursor to "IR CUT FILTER ", and then select options by moving the joystick to left or right.
5. ZOOM SPEED (System default is MEDIUM)
Set dome camera's default zoom speed from the menu. Zoom speed can be set to LOW, MEDIUM and HIGH. Setting method: move the cursor to "ZOOM SPEED", and select options by moving the joystick to left or right.
6. WIDE DYNAMIC RANGE (System default is OFF)
Wide dynamic range function can improve the image quality and get clear image in the stronger contrast light condition. Wide dynamic mode can be set to OFF, LOW, MEDIUM and HIGH. Setting method: move the cursor to "WIDE DYNAMIC RANGE" and select options by moving the joystick to left or right.
7. AUTO FLIP(System default is OFF)
Setting method: move the cursor to “AUTO FLIP ", and select ON or OFF by moving the joystick to left or right.
8. MIRROR (System default is OFF)
Setting method: move the cursor to "MIRROR", and select ON or OFF by moving the joystick left or right.
Page 50
IR Intelligent High-Speed Dome Installation and User Manual
Camera
Advanced
Setting
48
Setting method is as follows (note: this function needs support by
camera):
1. WHITE BALANCE (System default is AUTO)
You can change white balance from menu, so that the most
effective and real color image can be got in full ambient light. The
white balance model includes: AUTO, MANUAL, INDOOR,
OUTDOOR, AUTO TRACKING and SINGLE (Note: Different camera
may have different write balance options). Setting method: move the
cursor to "WHITE BALANCE", and then select options by moving the
joystick to left or right.
2. R GAIN
R gain is the gain of red components. Users can adjust red gain
value according to the actual situation (only when white balance is
MANUL, this setting can be effective). Setting method: move the
cursor to "R GAIN", and then adjust red gain value by moving the
joystick to left or right.
3. B GAIN
B gain is the gain of blue components. Users can adjust blue
gain value according to the actual situation (only when white balance
is MANUL, this setting can be effective). Setting method: move the
cursor to "B GAIN", and then adjust blue gain value by moving the
joystick to left or right.
4. EXPOSURE (System default is AUTO)
Users can adjust the camera exposure mode from the menu,
exposure mode can be set include: AUTO, MANUAL, SHUTTER,
IRIS, BRIGHTNESS (Note: Different camera may have different
exposure mode options). Setting method: move the cursor to
"EXPOSURE", and then select options by moving the joystick to left
or right.
5. BRIGHNESS/IRIS/SHUTTER
Users can adjust the image brightness from the menu. Setting
method: move the cursor to "BRIGHTNESS", and then adjust
brightness values by moving the joystick to left or right.
The setting methods of IRIS and shutter are similar with
"BRIGHTNESS".
The parameters of brightness, IRIS and shutter can adjust only
when exposure mode is MANUAL.
6. ANTISHOCK(System default is OFF)
You can close or open the camera antishock from the menu.
Setting method: move the cursor to "ANTISHOCK", and then select
ON or OFF by moving the joystick to left or right.
Page 51
IR Intelligent High-Speed Demo Installation and User Manual
Power up Action
Observe
49
Once power on, the unit enters self-checking procedure, when
the self-checking had finished, the unit can run customize commands.
1. POWER UP ACTION (system default CALL PRESET 1)
Move the cursor to "POWER UP ACTION", and then select the action which will run after power on by moving the joystick left or right. Optional power up actions (Total of 18 kinds of action options): NO ACTION
CALL PRESET 1 TO 8
START PATROL1 OR 2
START LINEAR SCAN 1 OR 2
START AUTO SCAN 1 OR 5
START PATTERN 1 OR 2
START AUTO TRACKING
Observe action setting means that if users have no operation within the specified time, the unit will run the specified function
1. OBSERVE TIME (System default is 30 SECS):
Move the cursor to "OBSERVE TIME ", and select observe time by moving the joystick to left or right. Options: 15 SECS, 30 SECS, 1 MIN, 5 MINS, 15 MINS, 30 MINS, 1 HOUR, 8 HOURS, 12 HOURS and 24 HOURS.
2. OBSERVE ACTION (System default is NO ACTION)
Move the cursor to "OBSERVE ACTION", and select observe action by moving the joystick to left or right. Options of observe actions (total 18 kinds of action options): NO ACTION
CALL PRESET 1 TO 8
START PATROL1 OR 2
START LINEAR SCAN 1 OR 2
START AUTO SCAN 1 OR 5
START PATTERN 1 OR 2
START AUTO TRACKING
Page 52
IR Intelligent High-Speed Dome Installation and User Manual
Date / Time
Password
50
The unit has date and time display function, user can modify
system date and time via the menu (Interface of numeric inputs only
accept digital input).The setting method is as follows:
1. DATE / TIME
1) Move the cursor to the corresponding item by moving the
joystick to left, right, up or down, and then press< IRIS
OPEN> to enter corresponding interface of numeric
inputs.
2) In "IPUT MSG" column, select input position by moving
the joystick to left and right, and the selected position
presents a twinkling state at this moment.
3) Move the cursor to digital area by moving down the
joystick, and press<IRIS OPEN> to select the digit, and
the selected digit will present a twinkling state, select
corresponding digit by moving the joystick to left, right, up
and down and then press <IRIS OPEN> to confirm, at the
same time, the input position moves to the next position in
"IPUT MSG" column. If you input an error digit, you can move the twinkling character to "" position, and press
<IRIS OPEN> to delete it, at the same time, the input
position moves to the previous position in "IPUT MSG"
column.
4) After completely input, you can press< IRIS CLOSE> to
exit digital area and the digit in digital area will stop
twinkling.
5) Move the cursor to "ENTER" by moving down the joystick,
and press< IRIS OPEN> to confirm input and return to the
interface of "DATE / TIME". If the cursor moves to
"CANCEL", press< IRIS OPEN>to cancel modification
and return to interface of "DATE / TIME".
2. CONFIRM
Move the cursor to "CONFIRM", and press <IRIS OPEN> to save
modification and return to the previous menu.
3. CANCEL
Move the cursor to "CANCEL ", and press<IRIS OPEN> to
cancel modification and return to the previous menu.
You can restrict users without permissions to modify the system settings through password protection function of the unit. If you open the password protection function, you need to input correct password when open the menu. The method to enable and modify password is as follows:
1. ENABLE PASSWORD
Move the cursor to "ENABLE PASSWORD ", and select ON or OFF by moving the joystick to left or right.
When password is ON, you need to input correct password to open the menu.
2. EDIT PASSWORD
Move the cursor to "EDIT PASSWORD", and press<IRIS open> to edit password. You need to input old password before you input a new password. The initial password of the unit is "000000". Password input please refers to the section of "Date / Time".
Page 53
IR Intelligent High-Speed Demo Installation and User Manual
Alarm
IR LED
51
The unit has 8 channels alarm input, 2 channels alarm output (alarm function need to select alarm module). when received the alarm, alarm input signal can trigger user defined action, meanwhile cause specified alarm output. Alarm function setting method is as follows:
1. ENABLE ALARM
You can open or close the alarm function. Setting method: move the cursor to "ENABLE ALARM", and select ON or OFF by moving the joystick to left or right.
2. ALARM NUMBER
Move the cursor to "ALARM NUMBER", and select alarm input channel by moving the joystick to left and right (Total of support eight alarm input channels). After alarm number changed, the system will automatically refresh associated setting items to display the corresponding data.
3. ALARM CONTACT
Move the cursor to "ALARM CONTACT", and select input type by moving the joystick to left or right. Alarm input type can be set to normally open or normally closed. N/O: Normally open. When channel is closed, it means system has received effective warning signs. N/C: Normally closed. When channel is open, it means system has received effective warning signs.
4. ALARM MODE
Alarm mode includes: AUTO, CLOCK and MANUAL. Move the cursor to the "ALARM MODE" and select mode by moving the joystick to left or right.
5. ACTIVATE AUX
Move the cursor to "ACTIVATE AUX", and select the output type by moving the joystick to left or right. The types use to set whether to link the alarm switch when system receives effective alarm input signal. The type can be set to OFF, 1, 2, and 1 & 2.
6. ALARM ACTION
Move the cursor to "ALARM ACTION ", and press <IRIS OPEN> to set alarm action. This function used to set whether link to some preset special functions, such as preset, patrol, pattern, linear scan when the current channel alarm.
7. PARK TIME
Move the cursor to" PARK TIME", press<IRIS OPEN> to set park time. When the current channel alarm occurs, if link to alarm output,
activate aux will be OFF, alarm park time is the time between
detecting alarm signals and removing the alarm (alarm output switch off). Options: 15 SECS, 30 SECS, 1 MIN, 5 MINS and 15 MINS.
8. START and CLOSE SCHEDULE
Start and close schedule means the time to open or close alarm, only when "START SCHEDULE is set to CLOCK, this setting is valid. Move the cursor to" START SCHEDULE", time input please refer to the section of "Date / Time".
You can open and close IR LED via the menu.
1. ENABLE IR LED (System default is AUTO)
AUTO: According to the brightness, IR LED can automatic
open and close.
CLOCK: IR LED can open and close according to the timing.
ON: Compulsorily open the IR lamp.
OFF: Compulsorily close the IR lamp.
2. IR BRIGHTNESS (System default is high power)
You can set IR brightness to HIGH, MEDIUM and LOW. Setting
method: move the cursor to "IR BRIGHTNESS", and select options by
moving the joystick to left or right.
3. START TIME
You can set the starting time of ENABLE IR LED only when the IR
LED is set to CLOCK. Please refer to the section of "Date / Time" to
input starting time.
4. CLOSE TIME
You can set the closing time of the IR LED only when ENABLE IR
LED is set to CLOCK. Please refer to the section of "Date / Time" to
input closing time.
5. ZOOM RATIO (System default is MEDIUM)
You can adjust the camera’s zoom ratio. The multiple values
including: HIGH, MEDIUM and LOW. Setting method: move the cursor
to "ZOOM RATIO", and select options by moving the joystick to left or
right.
6. SENSITIVITY (System default is MEDIUM)
When ENABLE IR LED mode is set to AUTO, the sensitivity of
brightness can be set to HIGH, MEDIUM and LOW. Setting method:
move the cursor to "SENSITIVITY", and select options by moving the
joystick to left or right.
7. SCAN TIME (System default is 15 SECS)
You can control the interval time of detecting the ambient light.
Options: 1 SEC, 3 SECS, 6 SECS, 15 SECS, 30 SECS, 1 MIN, and 5
MINS. Setting method: move the cursor to "SCAN TIME” and select
options by moving the joystick to left or right.
Page 54
IR Intelligent High-Speed Dome Installation and User Manual
Title Text
Advanced
Setting
52
Set the unit’s title from the menu and display it on monitor, so as
to identify each monitor point easily. The method is as follows:
Input method may be DIGIT, UPPERCASE, LOWERCASE,
SPECIAL SYMBOLS and CHINESE etc.
1. Move the cursor to "TITLE TEXT", and press <IRIS OPEN>to edit title text, and then move the cursor to "INPUT TYPE" by moving the joystick to up or down, and select suitable input method by moving the joystick to left or right. Optional input method is DIGIT, UPPERCASE, LOWERCASE, SPECIAL SYMBOLS and CHINESE.
2. Move the cursor to the next line under option of "INPUT TYPE", and press <IRIS OPEN> to enter character input mode, at this time the selected character is twinkling, select character by moving the joystick to up, down, left and right, press <IRIS OPEN> to put the twinkling character into the position of “” in "INPUT MSG" column
3. After the input the title is completed, move the cursor to "ENTER", and press <IRIS OPEN> to confirm input and return to the previous menu.
4. If move the cursor to CANCEL", and press<IRIS OPEN> will cancel the title modification and return to the previous menu.
1. AUTO FLIP (System default is ON)
When the len runs to 90°vertically, if the user keep direction of motion constant pressing the joystick, the lens will automatically flip 180º horizontally, thus consecutive monitoring of moving object can be realized. Setting method: move the cursor to "AUTO FLIP ", and select ON or OFF by moving the joystick to left or right.
2. PROPORTIONAL REDUCE (System default is ON)
Setting method: move the cursor to "PROPORTIONAL REDUCE", and select ON or OFF by moving the joystick to left or right.
3. PRESET FREEZE FRAME (System default is OFF)
Preset freeze frame means whether freeze current image when call the preset. Setting method: move the cursor to “PRESET FREEZE FRAME ", and select ON or OFF by moving the joystick to left or right.
4. MOUNTING STYLE (System default is NORMAL)
Mounting style includes: NORMAL and INVERSION. When inversed mounting, pictures and operating will auto adjust to match with the inverted mounting. Setting method: move the cursor to "MOUNTING SYTLE", and select options by moving the joystick to left or right.
Page 55
IR Intelligent High-Speed Demo Installation and User Manual
Set Soft
Address
Azimuth
Setting
53
You can open soft address from the menu. The address
identified by dial-up address of the unit will be shielded at this time.
1. ENABLE SOFT ADDRESS
Setting method: move the cursor to "ENABLE SOFT ADDRESS",
and select ON or OFF by moving joystick to left or right
2. RESET SOFT ADDRESS
Move the cursor to "RESET SOFT ADDRESS ", and press <IRIS OPEN> to edit soft address number, and then input the required number of soft address. About how to input soft address number, please refer to "Date / Time".
You can set horizontal azimuth from the menu. The north
direction is 0 ° angle direction in horizontal and corresponds with N
orientation of the compass.
1. SET AZIMUTH ZERO
Setting the current position to the north direction, move the cursor to "CONFIRM", and press <IRIS OPEN> to confirm that the current position is north direction. If you need to readjust, move the cursor to "EDIT AZIMUTH ZERO", and press<IRIS OPEN>, and then reorientate the north direction by moving the joystick to left or right, and press<IRIS OPEN> to confirm modification after the setting is complete.
Page 56
IR Intelligent High-Speed Dome Installation and User Manual
Set Privacy
Mask
54
Privacy mask function allows that privacy zones in the monitoring image can be shielded by black-box. Altogether 8 privacy zones can be set in the unit. The setting method is as follows:
1. GRID LINE SHOWN (System default is OFF)
The whole screen image can be divided into many small pieces through the grid lines, in order to orientate conveniently. Setting method: move the cursor to "GRID LINE SHOWN", and select ON or OFF by moving the joystick to left or right.
2. MASK NUMBER
Setting method: move the cursor to "MASK NUMBER”, and select number by moving the joystick to left or right.
Note: This function needs support by the camera. The number of privacy area is related to camera models.
3. ENABLE MASK (System default is OFF)
Move the cursor to "ENABLE MASK", and select ON or OFF by
moving the joystick to left or right.
4. SET PRIVACY AREA
Move the cursor to "SET PRIVACY AREA", and press <IRIS OPEN> to set mask zone, and then operate the joystick to control the unit, moving the zone which need to be masked to the center of the screen, and then press<IRIS OPEN> to enter the size setting mode of mask zone, and then adjust the size of mask area by moving the joystick to up, down, left or right, then press<IRIS OPEN> after the setting is complete.
5. CLEAR PRIVACY AREA
Move the cursor to "CLEAR PRIVACY AREA", and press<IRIS OPEN> to clear the corresponding privacy area.
Page 57
IR Intelligent High-Speed Demo Installation and User Manual
Communication
Testing
55
The unit can diagnose the stability of communication lines with TA8000 control software. Start communication test via software, the window such as the left picture will be shown on the screen, and the numbers of data packet sent from test software, the numbers of data packet received and the reliability of communication lines will be shown in the window.
Page 58
IR Intelligent High-Speed Dome Installation and User Manual
56
Page 59
IR Intelligent High-Speed Demo Installation and User Manual
Presets
Auto
Patrol
57
The IR intelligent high-speed dome stores horizontal , vertical,also coordinate and information of camera zoom. Users can quickly orientate the camera to the wanted testing scene. The unit supports 204 presets totally. The method to set preset is as follows:
1. PRESET NUMBER
Move the cursor to "PRESET NUMBER" and set preset number by moving the joystick to left or right. The unit supports 204 presets totally. (1 to 48 and 100 to 255).
2. EDIT PRESET LABEL
Move the cursor to "EDIT PRESET LABEL", and press <IRIS OPEN> to edit preset label. See the section of "Title Text" for more information.
3. CALL PRESET SCENE
Move the cursor to "CALL PRESET SCENE", and press <IRIS OPEN> to call the corresponding preset scene.
4. DEIT PRESET SCENE
Move the cursor to "DEIT PRESET SCENE”, and press <IRIS OPEN> to edit preset scene. When the unit reaches the expected preset scene, press <IRIS OPEN> to store the current position.
5. CLEAR PRESET
Move the cursor to "CLEAR PRESET", and press <IRIS OPEN> to delete the corresponding preset scene.
Auto patrol means the unit can switched among the specified presets. The switching time can be set by users. The unit supports 8 groups patrol path, each patrol path max. supports 32 presets. The setting method is as follows:
1. PATROL NUMBER
Move the cursor to "PATROL”, and select the patrol number by moving the joystick to left and right
2.
Edit Patrol SN#
Move the twinkling position to the corresponding position, and press<IRIS OPEN> to enter the modified mode, and then modify the value by moving joystick to left and right, after modification is complete, press<IRIS OPEN> to exit the modified mode.
Park time can be 1 SEC, 3 SECS, 6 SECS, 15 SECS, 30 SECS, 1 MIN, 5 MINS, 15 MINS, 30 MINS, 1 HOUR, 8 HOURS, 12 HOURS and 24 HOURS.
Patrol speed can be FAST, MEDIUM, and SLOW.
You can select serial number in different page through "Page Up" and "Page Down". Each page can show four serial numbers in all, move the cursor to "PAGE UP" or "PAGE DOWN", and press<IRIS OPEN> to page up or page down,
3. DEFULE
The default is the preset 1 to preset 4, the default park time is 6 seconds, and the default speed is FAST.
4.
START
Move the cursor to "START", and press <IRIS OPEN> to start the corresponding auto patrol.
Page 60
IR Intelligent High-Speed Dome Installation and User Manual
Linear Scan
Patterns
58
Horizontal linear scan means that the unit scans back and forth between two specified horizontal presets, and the scanning speed and scanning direction can be set by users.
1.
SCAN NUMBER
Move the cursor to "SCAN NUMBER ", and select scan number by moving joystick to left or right. Optional scan number is from 1 to
20.
2.
SCAN SPEED (System default is MEDIUM)
Move the cursor to "SCAN SPEED ", and select the speed by moving the joystick to left or right.
Options of scan speed: FAST, MEDIUM, SLOW.
3.
PARK TIME (System default is 1 SEC)
Move the cursor to “PARK TIME", and select the time by moving the joystick to left or right.
Options of park time: 1 SEC, 3 SECS, 6 SECS, 15 SECS, 30 SECS, 1 MIN, 5 MINS, 15 MINS, 30 MINS, 1 HOUR, 8 HOURS, 12 HOURS and 24 HOURS.
4.
SCAN DIRECTION
Move the cursor to "SCAN DIRECTION", and select the direction from A B and B A by moving the joystick to left or right.
The IR intelligent high-speed dome stores a series of users’ operations within the specified time, such as horizontal and vertical rotation, camera zoom operation etc. Users can review all operations that users have done by starting up the pattern. The unit supports four groups of patterns, each group can record 10 minutes or 500 instructions at most.
1.
PATTERN NUMBER
Move the cursor to "PATTERN NUMBER“, and select the number by moving joystick to left or right.
2. START PATTERN
Move the cursor to the "START PATTERN", and press <IRIS OPEN> to start the corresponding pattern.
3. PROGRAM PATTERN
Move the cursor to "PROGRAM PATTERN", and press <IRIS OPEN> to program pattern. The unit will automatically store horizontal and vertical rotation and camera zoom operation at this time. When the recording space is filled to full or press <IRIS OPEN>, the unit will stop the pattern settings.
4. CLEAR PATTERN
Move the cursor to "CLEAR PATTERN", and press<IRIS
OPEN>to delete the corresponding pattern.
Page 61
IR Intelligent High-Speed Demo Installation and User Manual
Clock
Auto Tracking
59
The timing of the unit can be divided into seven days a week, eight periods everyday. Users can set actions for every period according to the requirement. When the system time is in the specified period of time, the unit will automatically run the preset action.
1. START TIME
Move the cursor to "START TIME", and press<IRIS OPEN> to enter time input mode. Please refer to the section of Date / Time”.
2. CLOSE TIME
Move the cursor to "CLOSE TIME", and press<IRIS OPEN>to enter time input mode. Please refer to the section of Date / Time”.
3. CLOCK ACTION
The linked action of each period can be set as follows (18 kinds of actions in all). NO ACTION
CALL PRESET 1 TO 8
START PATROL1 OR 2
START LINEAR SCAN 1 OR 2
START AUTO SCAN 1 OR 5
START PATTERN 1 OR 2
START AUTO TRACKING
4. SET SCHEDULE
Move the cursor to "SET SCHEDULE", and press<IRIS OPEN> to set schedule.
Note: Different periods can't overlap, and the period can't span 00:00. If users operate the unit during timing period, the tim er action will be interrupted. If there is no action within the specified time and the current time is still in timing period, the timer action will be executed again.
Auto tracking IR intelligent integrative camera can intelligently
analyze the video images, and automatically track the moving object
in the monitoring area. In tracking mode, the unit will automatically
tack the moving target when the monitoring area has moving target.
When the moving target moves out of the monitoring area or it can’t
trigger the tracking function, the unit will stay for the preset park
time, and then return to the preset scene.
1. AUTO TRACKING
Move the cursor to "AUTO TRACKING", and select ON or OFF
by moving the joystick to left or right.
2. PRIORITY SIZE
Target size can be set to LARGE, MEDIUN and SMALL, and it
means that how big the moving targets can trigger the function of
auto track. Setting method: move the cursor to "PRIORITY SIZE ",
and select options by moving the joystick to left or right.
3. ZOOM
When auto tracking function are ON, the unit will automatically
adjust the zoom of the camera according to the size of the moving
target, so that the moving target can adapt to the scene of video
screen. Zoom track can be set to OFF, x1 to x10. Setting method:
move the cursor to “ZOOM", and select options by moving the
joystick to left or right.
4. RETURN TIME
In the menu of auto tracking, users can set and delete the return
time which the unit needs to wait after the moving target disappears
from the monitoring area. Return time can set to 3 SECS, 6 SECS, 15
SECS, and 30 SECS.
5. SET TRACKING SCENE
In the menu of set tracking scene, users can set and delete the
scene which the unit needs to return after the moving target
disappears from the monitoring area.
Page 62
IR Intelligent High-Speed Dome Installation and User Manual
Zones
Reboot
Restore
60
When users move the unit into the range of the specified preset zone by operating the joystick, the screen will display the title of this preset zone, so that users can check different zones conveniently. The unit supports eight zones indications. Users can enable zones only when the left border and the right border are set firstly. Priority of zones: 1 as highest priority, and 8 as lowest priority. When deferent zones are overlap, only higher priority zone can be shown. The setting method is as follows:
1. ZONE NUMBER
Move the cursor to the "ZONE NUMBER” and select number by moving the joystick to left or right.
2. EDIT ZONE LABEL
Move the cursor to "EDIT ZONE LABEL", and press <IRIS OPEN> to edit zone label. Set the zone label referring to the section of "Title Text”.
3. SET LEFT BORDER
Move the cursor to "SET LEFT BORDER", and press <IRIS OPEN> to set left border, and then move the cursor to expected position by operating the joystick, and then press < IRIS OPEN >to storage the current position as the left border.
4. SET RIGHT BORDER
Move the cursor to "SET LRIGHT BORDER", and press<IRIS OPEN> to set right border, and then move the cursor to expected position by operating the joystick, and then press < IRIS OPEN >to storage the current position as the right border.
5. CLEAR
Move the cursor to "CLEAR", and press<IRIS OPEN>to delete the corresponding zone.
The function of restore factory defaults can restore all operation
that users did to the factory default settings. Operation method: open
the menu, and move the cursor to "RESTORE FACTORY
DEFAULTS", and Press<IRIS OPEN>to enter the confirmation menu
of factory settings, and then Press<IRIS OPEN>again to restart the
unit and restore factory settings or press <IRIS CLOSE>to cancel the
operation of restore factory settings.
IR intelligent high-speed dome can be rebooted remotely from the menu. Operation method: open the menu, and move the cursor to “REBOOT“, and then press <IRIS OPEN> to enter the confirmation menu of reboot, and then press<IRIS OPEN> again to reboot system or press <IRIS Close> to cancel the operation of reboot system.
Page 63
IR Intelligent High-Speed Demo Installation and User Manual
Factory Defaults
Simple
Trouble
Shooting Table
Problems Possible causes solutions
No action, no picture
when power is switched
on.
Power supply adaptor damaged
or
Replace
Wrong contact of power cables Correct
Engineering line fault Exclude
Abnormal self-check,
image shown with motor
noise
Mechanical failure Repair
Camera inclined Reinstall
Power supply not sufficient adaptor nearby the unit
Normal self-check Wrong contact of video lines Correct
61
Page 64
IR Intelligent High-Speed Dome Installation and User Manual
but no image Bad contact of video cables Exclude
Camera is damaged Replace
Normal self-check and
image but out of control
Wrong contact of control signal Correct
Address configuration wrong Choose new address and
power
Protocol or Baud rate configuration
Adjust Protocol, baud rate to
Unstable image Bad contact of video cable Exclude
Power supply not sufficient or
Replace
IR intelligent high-speed
dome out of control
Abnormal self-check Power On again
Bad contact of control lines Remove
The host operations have a
Power up the host again
the load is too much ,t
he distance
Increase yards distributor
Focus out of control Focus is in automatic mode Set focus mode to manual
Lightning and Surge Protection
This product adopts Ceramic Gas Discharge Tube and TVS-class lightning protection technology to
effectively prevent such pulse signal damage caused by instantaneous lightning under 3KW or electric
surge. But, for outdoor installing, on the premise of ensuring electric safety, necessary protective
measures should be taken according to practical situation:
Signal transmission lines must be kept at least 50 meters from high voltage equipment and high
voltage.
For outside, please select the place under eaves to layout the routing.
For open field, you must use underground sealed steel tube, and the steel tube must be adopted
one point grounding mode, and absolutely forbid adopted overhead wiring.
In intense thunderstorms or high induced voltage areas (such as high voltage substations), must
use extra high-power lightning protection equipment and install lightning rod and others measures.
The lightning protection and grounded design for outdoor installation and wiring must be combined
62
Page 65
IR Intelligent High-Speed Demo Installation and User Manual
with requirements of building's lightening prevention, and comply with the relevant national
standards and industry standards.
The system must be equipotential grounding. Grounded device must meet double requirements of
system anti-jamming and electrical safety, and can’t be short-circuited or hybrid-circuited with
neutral leg of forceful electric power. When system grounded alone, the impedance of grounded
conductor can’t more than 4 ohm, and sectional area of grounded wire can’t more than 25mm
2
wire shorted.
Propositional
preventive maintenance
The cover of IR
intelligent high-speed dome
doesn’t need any special
maintenance. Dust may
accumulate on the inside or outside of the dome cover occasionally
. When it is happen, please shut off the power firstly and then
remove downward dome cover from dome base, then clean up the dust on the dome cover by
compressed air in the sprayer.
Warning: When us e the sprayer , please wear appropriate eyeshade.
This unit includes various electrical and electronic device, these devices must comply with the EU
Directive 2002/96/E of Waste Electrical and Electronic Equipment (WEEE) to properly recycle. About the
recycling of this unit, please contact with local supplier.
63
Page 66
IR Intelligent High-Speed Dome Installation and User Manual
CCTV
SYSTEM
▐▌
64
Loading...