DN-7051:E2 • A0-185
ONYX FirstVision™
Interactive Firefighters’ Display
Network Systems
General
ONYX FirstVision™ is a revolutionary wayfinding navigational
tool for firefighters and other emergency responders. ONYX
FirstVision, a touch screen based annunciator, graphically dis
plays critical information on the origin and spread of a fire;
allowing firefighters to quickly locate and extinguish the fire.
With ONYX FirstVision, emergency responders can immediately gather the information needed to accurately pinpoint the
source of the fire and the rate at which it’s spreading. Crucial
information is easy to access with a spatial, graphical depiction
of the location of activated detectors and detector sequence of
activation for one or multiple buildings. In addition, ONYX First
Vision is an interactive interface. It displays a summary of
building floor plans with detailed information about the build
ing. Details can include locations for all fire alarm devices;
water supplies; evacuation routes; access routes; chemical
and structural hazards in the building; and shutoffs for gas,
power, and HVAC.
-
-
-
Features
GENERAL
• 22" LCD touch-screen.
• Interfaces with ONYX® Series panels or NOTI•FIRE•NET
(version 5.0 or higher) through the NFN Gateway over
Ethernet.
• Compatible with standard and High Speed
NOTI•FIRE•NET™.
• Supports the following additional languages: French (Canadian), Hebrew, Korean, Portuguese, Spanish, Thai, and
Chinese (Traditional and Simplified).
• Supports multiple gateways for large networks and campuses.
USER INTERFACE
• Large intuitive display shows building floor plans in a campus footprint with respective active fire alarm devices, water
supplies, evacuation routes, access routes, gas, power and
HVAC shutoffs, and chemical and structural hazards in the
building.
• Detailed information for active devices or critical building
icons on the floor plan.
• Easy access to building, emergency contacts, site plan, and
alarm event information.
• Able to print screenshots.
• Stores MSDS (Materials Safety Data Sheet) attachment.
• User download of event log file.
EVENT NOTIFICATION
• Graphic and text event notification of fire, supervisory, security, and medical events.
• Fast automatic navigation to floors and locations of the
emergency events.
• Priority based event list display.
• First alarm display to identify where the emergency started.
• Time sequence display of activated detectors to track
smoke progression.
• Configurable sound notification with silence selection.
• Configurable to unlock door based on events.
SYSTEM SETUP
• Screen development tool can easily import building floor
plan CAD drawings (as a .wmf, .bmp, or .jpg file) and Veri
Fire® Tools databases.
• Standard icon library indicates fire alarm and critical building devices.
• Ethernet and USB ports available for transferring screen
database information.
Specifications
NOTE: Dimensions are subject to change. Contact NOTIFIER for
further information.
Enclosure Dimensions: 24.53" W X 21.92" H X 3.47" D
(62.30 cm H x 55.68 cm W x 8.81 cm D).
• Door Dimensions: 26.70" W X 23.06" H X 0.41" D
(67.81 cm H x 58.57 cm W x .10 cm D).
• Power Requirements: Regulated, filtered 24 VDC @ 3.0 A
via non-resettable power supply, UL/ULC Listed for fire-pro
tective signaling use.
• Temperature Range: 0°C – 50°C (32°F – 120°F).
Listings and Approvals
These listings and approvals apply to ONYX FirstVision™.
• UL/ULC Listed: S5697
• MEA: 286-07-E
• CSFM: 7300-1525:0103
• FDNY: COA#6070
-
-
DN-7051:E2 • 5/15/2014 — Page 1 of 4
Ordering Information
NOTI•FIRE•NET™
Network version 5.0
(standard or
high-speed)
NFS2-30300
NFS2-640 AM2020/
AFP1010
IP connection
over Ethernet
ONYX FirstVision™
7051cov-10.JPG; cab4c.wmf,
nfngw3.bmp
NFN-GW-EM-3 Network Control
Module
GRAPHICAL ICON KEY
Activated
Smoke
Detector
Gas Tank
Area of
Refuge
Master
Sprinkler
Shutoff
Activated
Duct
Detector
Halon
Fire
Phone
Power
Shutoff
Activated
Pullstation
Hydrant
Fire
Service
Keybox
Room Contains
Hazardous
Materials
Activated
Sprinkler
Device
HVAC
Shutoff
Fire
Service
Display
Stairs
Activated
Heat
Detector
Locked
Door
Gas
Shutoff
Standp ipe
WARRANTY: This product is warrantied for a period of 36
months. The PC and monitors are warranted from date of purchase for a period of 36 months. Please refer to NOTIFIER’s
mited Warranty Policy for additional information.
Li
FIRSTVISION-LCD: ONYX Fi
rstVision™ User Interface soft-
ware and hardware package. Includes 22" LCD touch-screen,
ard Ethernet, and USB ports. Also includes one software
Onbo
license and screen configuration software (FirstVision-SCT).
Does not include backbox, order separately.
FIRSTVISION-ENC: ONYX F
irstVision™ backbox enclosure
and door.
Additional required components:
• NOTI•FIRE•NET Gateway (P/N NFN-GW-EM-3 or NFNGW
-PC-xx series).
Firefighters’ Display
• NCM-W, NCM-F or HS-NCM/WMF/WSF/MFSF for connection to NOTI•FIRE•NET™.
• Standard Ethernet network cable with RJ45 connectors.
• Standard Ethernet network cable with RJ45 connectors and
b/switch or Standard Ethernet crossover cable.
hu
• PC with Windows® 7 Professional and available Ethernet or
ort (used for programming).
USB p
Applications
An ONYX FirstVision™ display is an ideal component of a
NOTIFIER fire system providing real-time fire system status to
firefighters. ONYX FirstVision™ interfaces directly to ONYX
Series control panels and an entire NOTI•FIRE•NET network.
ONYX FirstVision™ Software
NOTE: This is not a complete list of all the icons. The following
icons are a representative sample.
Page 2 of 4 — DN-7051:E2 • 5/15/2014