INSTALLATION AND MAINTENANCE INSTRUCTIONS
9
8
7
6
5
4
3
2
1
0
0
1
2
3
4
5
6
7
8
9
TENS
ONES
ADDRESS
LOOP
0
7
8
6
5 4 3
2
1
9
10
11
12
13
14
15
FRM-1 Relay Control Module
Northford, CT 06472-1653
Specications
Normal Operating Voltage: 15 to 32 VDC
Maximum Current Draw: 6.5 mA (LED on)
Average Operating Current: 270µA (LED ashing)
EOL Resistance: Not used
Temperature Range: 32˚F to 120˚F (0˚C to 49˚C)
Humidity: 10% to 93% Noncondensing
Dimensions: 41/2″ H x 4″ W x 11/4″ D (Mounts to a 4″ square by 21/8″ deep box.)
Accessories: SMB500 Electrical Box; CB500 Barrier
12 Clintonville Rd
(203) 484-7161
Before Installing
This information is included as a quick reference installation
guide. Refer to the appropriate Notier control panel installation
manual for detailed system information. If the modules will be
installed in an existing operational system, inform the operator
and local authority that the system will be temporarily out of ser-
vice. Disconnect power to the control panel before installing the
modules.
NOTICE: This manual should be left with the owner/user of this
equipment.
General Description
The FRM-1 Relay Control Module is intended for use in intelligent,
two-wire systems where the individual address of each module is
selected using the built-in rotary switches. It allows a compatible
control panel to switch discrete contacts by code command. The
relay contains two isolated sets of Form-C contacts, which operate
as a DPDT switch and are rated in accordance with the table in
the manual. Circuit connections to the relay contacts are not su-
pervised by the module. The module also has a panel controlled
LED indicator. This module can be used to replace a CMX-2 mod-
ule that has been congured for Form-C operation.
Compatibility Requirements
To ensure proper operation, this module shall be connected to a
compatible Notier system control panel (list available from Noti-
er).
Mounting
The FRM-1 mounts directly to 4 square electrical boxes (see Fig-
ure 2A). The box must have a minimum depth of 2
mounted electrical boxes (SMB500) are available from Notier.
Wiring
NOTE: All wiring must conform to applicable local codes, ordi-
nances, and regulations. When using control modules in nonpower limited applications, the CB500 Module Bar­rier must be used to meet UL requirements for the sepa­ration of power-limited and nonpower-limited terminals
1. Install module wiring in accordance with the job drawings and
N500-47-00 1 I56-1170-04
www.PDF-Zoo.com
and wiring. The barrier must be inserted into a 4x4x2 /8″ junction box, and the control module must be placed into the barrier and attached to the junction box (Figure 2A). The power-limited wiring must be placed into the isolated quadrant of the module barrier (Figure 2B).
1
/8″. Surface
appropriate wiring diagrams.
2. Set the address on the module per job drawings. Note: Some panels support extended addressing. In order to
set the module above address 99 on compatible systems, care­fully remove the stop on the upper rotary switch with thumb in the direction shown in Figure 1.
3. Secure module to electrical box (supplied by installer), as shown in Figure 2A.
Figure 1. Removing rotary switch stop:
A78-2318-07
Figure 2A. Module mounting with barrier:
Figure 2B:
1
A78-2611-11
A78-2610-08
MODULE
FROM PANEL OR
(+)
(–)
TO NEXT
(+)
(–)
DEVICE
(+)
(–)
CONTROL
CONNECT MODULES TO LISTED COMPATIBLE
RELAY COMMON 1
RELAY COMMON 2
NORMALLY CLOSED 1
NORMALLY OPEN 2
NORMALLY CLOSED 2
MODULE DOES NOT SUPERVISE CONTROLLED CIRCUITS
NORMALLY OPEN 1
CONTROL PANELS ONLY
PREVIOUS DEVICE
COMMUNICATION LINE
32 VDC Max.
SHIELDED-TWISTED PAIR
IS RECOMMENDED
9
8
7
6
5
4
3
2
1
0
ADDRESS
LOOP
Relay Contact Ratings:
CURRENT RATING MAXIMUM VOLTAGE LOAD DESCRIPTION APPLICATION
3 A
2 A
.9 A
.9 A
.5 A
1 A
.5 A
.7 A
30 VDC
30 VDC
110 VDC
125 VAC
30 VDC
30 VDC
125 VAC
75 VAC
Resistive
Resistive
Resistive
Resistive
Inductive (L/R=5ms)
Inductive (L/R=2ms)
Inductive (PF=.35)
Inductive (PF=.35)
Non Coded
Coded
Non Coded
Non Coded
Coded
Coded
Non Coded
Non Coded
All relay switch contacts are shipped as shown in Figure 3, but may have transferred during shipping. To ensure that the switch contacts are in their correct state, modules must be made to communicate with the panel before connecting circuits controlled by the module.
Figure 3. Relay module wiring diagram:
IF ANY WIRING TO TERMINALS 3 – 9 IS NONPOWER LIMITED, THE CB500 BARRIER IS REQUIRED. THE CB500 INCLUDES A NONPOWER LIMITED LABEL, WHICH MUST BE PLACED OVER THE POWER LIMITED TERMINAL INFORMATION ON THE NAMEPLATE LABEL.
N500-47-00 2 I56-1170-04 ©2001 Notier