FCO-851(A) IntelliQuad™ PLUS
60689cov.JPG
FCO-851(A) in B200S(COA) Sounder Base
Advanced Multi-Criteria
Fire/CO Detector
General
World-class fire and carbon monoxide (CO) detection combined in a single addressable device provides a practical solution for today’s market.
The IntelliQuad PLUS FCO-851(A) Advanced Multi-Criteria
Fire/CO Detector is a plug-in, addressable device that provides both fire and carbon monoxide (CO) detection. For fire,
the detector combines four separate sensing elements in one
unit (smoke, CO, light/flame, and heat) to sense multiple components of a fire. This approach enables enhanced sensitivity
to real fire with heightened immunity to nuisance particulate.
For CO, the detector’s electrochemical sensing cell creates a
separate signal for life safety CO detection.
CO is a colorless, odorless, and deadly gas that is virtually
impossible to detect with the human senses. It is released
whenever carbon-based fuels (from fossil fuels to firewood)
burn without enough oxygen to form CO
tial exists for dangerous levels of CO to accumulate in almost
any building, legislation mandating the use of CO detection in
commercial spaces continues to increase across the U.S. and
Canada. The FCO-851(A) is listed to the UL 268 standard for
smoke detectors and the UL 2075 standard for system-connected life safety carbon monoxide monitoring.
The FCO-851(A) should be used in conjunction with the
B200S(COA) intelligent sounder base, which can generate
either a Temp 3 pattern for fire or a Temp 4 pattern for CO
alarm indication.
The B200S(COA) recognizes the System Sensor synchronization protocol. This enables it to be used as a component of the
general evacuation signal — along with other System Sensor
horns, horn strobes, and chimes — when connected to a
power supply or Fire Alarm Control Panel (FACP) output capable of generating the System Sensor synchronization pulses.
With each sounder base carrying a unique address, the FACP
can then command an indvidual sounder — or a group of
sounders — to activate. The command set from the panel can
be tailored to the specific event, allowing selection of volume,
tone, and group.
NOTE: The FCO-851(A) is compatible with the NFS-320(C), NFS320SYS, NFS2-640, and NFS2-3030 operating with firmware version 17.0 (or higher) in FlashScan® mode; CLIP mode not supported.
Features
• Unique ability to detect all four major elements of a fire.
• Separate CO detection signal.
• Highest nuisance alarm immunity.
• Automatic drift compensation of smoke sensor and CO cell.
• Uses only one address on the SLC.
• RealTest® CO testing capability.
• Separates audible signal for fire or CO alarm when used
with the B200S base (B200SCOA in Canada).
• CO cell end-of-life warning and fault.
• FlashScan operation.
. Because the poten-
2
Sensitivity Settings and
Suggested Applications
• Level 1: 1% / ft of smoke. Suggested for very clean envi-
• Level 2: 2% / ft of smoke. Suggested for clean environ-
• Level 3: 3% / ft of smoke. Suggested for moderately clean
• Level 4: 3% / ft of smoke with different algorithm process-
• Level 5: 4% / ft of smoke. Suggested for equipment rooms,
• Level 6: Thermal alarm at 135°F (57°C).
Once the CO cell has reached end-of-life, the CO sensor no
longer provides life safety protection; however, when the fire
detector enters Photo, Thermal, Infrared (PTIR) mode, the following sensitivities apply:
• Level 1: 1% / ft of smoke. Suggested for very clean envi-
• Level 2: 2% / ft of smoke. Suggested for clean environ-
• Level 3: 3% / ft of smoke. Suggested for moderately clean
• Level 6: Thermal alarm at 135°F (57°C).
Specifications
PHYSICAL SPECIFICATIONS
Size: 3.46" (8.79 cm) high x 6.875" (17.46 cm) diameter
installed in B200S(COA) base.
Shipping weight: 4.6 oz. (130.41 g).
Color: Ivory.
DN-60689:B
Intelligent/Addressable Devices
ronments such as laboratories.
ments such as offices.
environments such as hotel rooms, dorm rooms.
ing and weighting of sensor elements. Suggested for hotel
rooms near a shower, boiler rooms.
kitchens, paint shops.
ronments such as laboratories.
ments such as offices.
environments such as hotel rooms, dorm rooms.
DN-60689:B • 12/3/2012 — Page 1 of 2
Operating humidity range: 15% – 90% relative humidity
(noncondensing).
Operating temperature: 0°C to 38°C (32°F to 100°F).
Air velocity: 0 – 4000 ft./min. (0 to 20 m/sec.).
ELECTRICAL SPECIFICATIONS
Operating Voltage range: 15 – 32 volts VDC.
Standby current (max. avg.): 300 μA at 24 VDC (one com-
munication every 5 seconds with LED blink enabled).
Maximum Alarm Current (LED on): 7.2 mA at 24 VDC.
CO ALARM ACTIVATION LEVELS
Alarm activation levels as defined by UL Standard 2034:
Concentration
of CO
70 (+/- 5) PPM 240 min (not less than 60 min)
150 (+/- 5) PPM 50 min (not less than 10 min)
400 (+/- 10) PPM 15 min (not less than 4 min)
Maximum Alarm Time
Response
Ordering Information
NOTE: “A suffix indicates ULC listed model.
FCO-851: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO
Detector.
FCO-851A: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO
Detector, ULC listed.
B200S: Intelligent programmable sounder base.
B200SCOA: Intelligent programmable sounder base, ULC
listed. Includes CO detector markings in English and French.
M02-04-00: Detector Test Magnet.
M02-09-00: Telescoping Test Magnet.
Agency Listings and Approvals
The listings and approvals below apply to the primary product.
In some cases, certain modules may not be listed by certain
approval agencies, or listing may be in process. Consult factory for latest listing status.
• UL: S1115 (FCO-851).
• ULC: S1115 (FCO-851A).
• CSFM: 7275-0028:0264.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
Page 2 of 2 — DN-60689:B • 12/3/2012
IntelliQuad™ is a trademark and NOTIFIER®, RealTest® and FlashScan®
are registered trademarks of Honeywell International Inc.
©2012 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
www.notifier.com