Acclimate® Plus™ Multi-Sensor Low-Profile Intelligent Detector
General
The Notifier FAPT-851(A) Acclimate® Plus™ detector is an intelligent, addressable, multi-sensing, low-profile detector designed for use with Notifier Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs).
The Acclimate Plus detector uses a combination of photoelec­tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli­mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus detector adjusts its sensitivity automatically, without operator intervention or control panel programming.
Areas where the Acclimate Plus detector is especially useful include office complexes, schools, college campuses, manu­facturing and industrial facilities, and anywhere else the use of a particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment.
FlashScan® (U.S. Patent 5,539,389) is a communication pro­tocol developed to greatly enhance the speed of communica­tion between analog intelligent devices and compatible systems. Intelligent devices communicate in a grouped fash­ion. If one of the devices within the group has new information, the panel’s CPU stops the group poll and concentrates on sin­gle points. The net effect is response speed greater than five times that of earlier designs.
Features
• Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat.
• Microprocessor-based, combination photo and thermal technology.
• Compatible with all Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs).
• Addressable-analog communication.
• Sleek, low-profile design.
• Two-wire SLC connection.
• Addresses can be viewed and changed without electronic programmers.
• Dual bi-color LED design provides 360° viewing angle.
• LEDs lock red when in alarm. In FlashScan, LEDs flash green in standby for normal condition.
• Built-in tamper-resistant feature.
• Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance.
• SEMS screws for wiring of the separate base.
• Several base options, including relay, isolator, and sounder.
• Built-in functional test switch activated by external magnet.
• Listed to UL 268.
• Capable of heat-only alarm mode, enabled by a special command from the panel. Smoke alarms are ignored.
• Low-temperature signal at 45°F +/– 10°F (7.22°C +/–
5.54°C).
DN-6937:D
Intelligent/Addressable Devices
Specifications
Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with systems; fixed-sensitivity levels: 1, 2, and 4%/ft. with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft. with FlashScan systems.
Size: 2.0" (5.3 cm) high; base determines diameter.
– B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200S(A): 6.875" (17.46 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter.
Shipping weight: 5.2 oz. (147 g).
Operating temperature: 0°C to 38°C (32°F to 100°F).
UL-Listed velocity range: 0 – 4000 ft./min. (1219.2 m/min.),
suitable for installation in ducts.
Relative humidity: 10% – 93% noncondensing.
Thermal sensing rating: fixed-temperature setpoint 135°F
(57°C).
ELECTRICAL SPECIFICATIONS
Voltage range: 15 – 32 volts DC peak.
Standby current (max. avg.): 300 μA.
Loop resistance: 50 ohms maximum; varies according to
control panel used. Refer to panel installation manuals.
LED current (max.): 6.5 mA @ 24 VDC (“ON”).
Installation
The FAPT-851(A) plug-in detector uses a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec­tors without using a ladder. Suitable mounting base boxes include:
DN-6937:D • 12/07/2011 — Page 1 of 2
Made in the U.S. A.
• 4.0" (10.16 cm) square box.
• 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box.
• Single-gang box (except relay or isolator base).
NOTE: The FAPT-851(A) detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self-contained heater.
Agency Listings and Approvals
These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro­cess. Consult factory for latest listing status.
UL Listed: S1115.
ULC Listed: S1115.
MEA Listed: 225-02-E.
• FM Approved.
CSFM: 7272-0028:0206.
U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)).
Lloyd’s Register: 11/600013 (NFS2-640, NFS-320/NFS- 320C, excluding B210LP(A)).
Maryland State Fire Marshal: Permit # 2122.
Ordering Information
NOTE: “A” suffix indicates ULC Listed model.
FAPT-851: Low-profile intelligent multi-sensor detector.
FAPT-851A: Same as FAPT-851 but with ULC Listing.
INTELLIGENT BASES
NOTE: “A” suffix indicates ULC Listed model.
NOTE: For details about intelligent bases and their mounting, see
DN-60054.
B210LP(A): Plug-in detector base; standard U.S. flanged low­profile mounting base.
B210LPBP: Bulk pack of B210LP; package contains 10.
B501(A): Flangeless mounting base.
B501BP: Bulk pack of B501; package contains 10.
B200S
(A): Intelligent, programmable sounder base capable of
producing sound output in high or low volume with ANSI Tem­poral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone.
B200SR
sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications.
B224RB
mm²). Relay type Form-C. Rating: 2.0 A @ 30 VDC resistive;
0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive.
B224BI
lator bases.
(A): Intelligent sounder base capable of producing
(A): Relay base Screw terminals: up to 14 AWG (2.0
(A): Isolator base. Maximum: 25 devices between iso-
ACCESSORIES
F110: Retrofit flange to convert B210LP to match the B710LP profile, or to convert older high-profile bases to low-profile.
F110BP: Bulk pack of F110; package contains 15.
F210: Replacement flange for B210LP(A) base.
RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S.
single-gang electrical box. Supported by B210LP(A) and B501(A) bases only.
SMB600: Surface mounting kit for use with B210LP(A).
M02-04-00: Test magnet.
M02-09-00: Test magnet with telescoping handle.
XR2B: Detector removal tool. Allows installation and/or
removal of FlashScan® Series detector heads from base in high ceiling installations.
T55-127-010: Detector removal tool without pole.
XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524
m) sections.
Notifier®, ONYX®, FlashScan®, and Acclimate® are registered trademarks and Acclimate Plus™ is a trademark of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com
Page 2 of 2 — DN-6937:D • 12/07/2011
Loading...