E3Point
Make your operation run more intelligently to protect people, property and your bottom line
E3Point Toxic and Combustible Gas Monitor
Flexible Operation
• Comes in standalone, standalone with remote (dual gas mode) or network versions
• Connects to analog or digital systems
• Works with virtually any BAS including BACnet,
Modbus or LonWorks*
• Connects to wired or wireless system (via 301CW wireless controller)
• Wall or duct mount
• Factory-calibrated cartridges
Cost Effective
• Saves energy through Demand Control
Ventilation (DCV)
• Simplies installation/maintenance through
plug-n-play sensor
• Remote sensor option provides dual gas monitoring (standalone version only)
• Optimizes BAS, re, ventilation and other security systems
Versatile Communications
• Works through BAS to improve fault
diagnostics and collect data on gas
concentation levels, sensor condition, etc.
• Couple with 301C to log data and daisy-chain up to 96 E3Point units
Advanced Sensing Technology
• Detects CO, NO2, O2, H2, H2S, CH4, C3H
• Advanced electrochemical (for toxic gases)
and catalytic bead (for combustible gases) sensor performance
• Uses patented Reex® and smart cartridge technologies
8
Range of Accessories
• Factory-calibrated replacement cartridges
• Power transformer
• Vandal-resistant steel wire detector guards
• Tamper-proof screws
• Horns and strobes
E3Point goes beyond protection to offer your building greater performance and productivity.
Plug-N-Play
Sensor Cartridge
Remote Unit
Plug-N-Play Ease
E3Point’s plug-n-play sensor is factory
calibrated and works out of the box. Upon installation, E3Point automatically congures for quick operation. You benet from easier installation and maintenance, and greater adaptability to changing building and safety requirements.
Main Unit
Ergonomic
features built into
3
Point include a
E
hinged door for
maintenance ease.
Reex® Keeps You Safer
Only Honeywell’s patented Reex® technology adds this extra degree of precision and diligence to sensor monitoring to make doubly sure you’re safe. Reex bounces electrical signals into the
E3Point electrochemical sensor cell at regular
intervals, a form of electronic bump testing and continuous monitoring of cell response.
Electrical Certications
• US (ANSI/UL 61010-1)
• Canada (CSA C22.2 No. 61010-1)
* pending - call your sales rep for information
Efficient
Operations
Smart sensor design,
extreme temperature
range, etc. optimize
building performance
Energy
+
Savings
On-demand
ventilation controls
energy use
Economical
+
Value
Reduces cost of
installation, operation
and maintenance
=
E3Point
Oscilloscope graph shows cell responding
to Reex pulse, indicating sensor condition.
GREEN shows optimal sensor condition
(dynamic responsiveness to gas).
RED shows degraded sensor condition
(indicating cell dry-out or failure).
Flexible Applications
E3Point integrates easily with your building’s analog or digital
infrastructure as a standalone unit or network addressable device. Here are ve installation examples to make E3Point work for you.
E3Point Standalone Single-Sensor Operation
A low-cost application for buildings with minimal gas monitoring requirements typical of a small facility. Offers easy installation, commissioning and operaton. Two on-board relays can activate fan or strobe.
E3Point Standalone Dual-Gas Sensor Operation
Remote
Unit
Economical application adds option of a second (remote) sensor for dual gas monitoring. Two on-board relays can activate ventilation or strobes.
Base Unit
E3Point/Wired-Wireless Hybrid Conguration
E3Point/Modbus Conguration
301C
Modbus Communication
301R8
Modbus Communication
BAS
3
Point
E
Up to 3 x 32 units
Supports Modbus protocol to daisy-chain E3Point detectors, providing up to 96 points of monitoring on a serial bus. Excellent option for controller­based (VA301C) installations common in larger applications. A relay output is provided as an option for activating ventilation directly (e.g. when fan is located in close proximity to detector).
E3Point/BACnet (MS-TP) Conguration
BAS
Wireless Network
301CW & 301W
E3Point offers a perfect solution for applications that require a
hybrid wireless/wired system. In this conguration, E3Point outputs signals to a controller (301CW) that also accepts signals from a wireless gas detector (301W). This scheme offers great exibility and installation cost savings for retrot projects. It easily handles difcult installation challenges, such as those posed by obstructions. A relay output is provided when it is desirable to activate fan/ventilation directly (e.g. when fan is located in close proximity to detector).
E3Point
Network
BACnet Communication
BAS
DVC
HVAC
Alarms, Strobes, Horns
Wireless Network
301CW & 301W
E3Point outputs directly to BACnet or other BAS. Alarms, strobes and
horns are activated through BAS with link to DCV/HVAC controls. This system design supports new and retrot installations for large buildings, and can couple with a controller to effectively integrate wired and wireless system components. A relay output is provided as an option for activating ventilation directly (e.g. when fan is located in close proximity to detector).
Dual-Gas Detection In Many Combinations
E3Point Expands the Range of Gas Detection
to Serve Practically All Building Areas, Including Outbuildings
Carbon
Monoxide
Propane
E
(C
)
L
3H8
B
A
Methane
M
M
A
L
F
E3Point’s standalone, dual-gas conguration monitors
two gases simultaneously and cost effectively, in any
of the following combinations: toxic-toxic,
monitor two combustible gases simultaneously.)
)
(CH
4
Hydrogen
(H
)
2
toxic-combustible, oxygen-toxic, or
oxygen-combustible
(CO)
E3Point
Oxygen
(O
2
Y
X
O
. (The device cannot
Nitrogen
Dioxide
Hydrogen
Sulde
)
E
G
(NO
(H
N
T
O
X
I
C
)
2
S)
2
Building Environment (Detected by E
Parking Structure CO, NO2, C3H
Loading Dock CO, NO2, C3H8,H
Transport Terminal CO, NO2, C3H8,CH
Golf Cart Maintenance/ CO, NO2, CH4, Battery Charging Area O2, H
Maintenance Garage O
Gases Present
8
2
CO, NO2, C3H8,
, H2S, H
2
2
3
Point)
2
4
Hospital/Ambulance Bay CO, NO2, C3H
Fire/Police Station O
Car Wash CO, NO2, C3H
Battery Charging Rooms & Hydrogen Tanks
Commercial Kitchen C3H
Indoor Stadium/Arena CH4, CO, C3H
CO, NO2, C3H8,
, H2, H2S
2
H
2
8,
CO, CH
8, O2
8
4
8
H_E3Point_DS01081_V1_US 6/09 © 2009 Honeywell Analytics