Notifier APS-6R User Manual

APS-6R
6.0 Amp Auxilary Power Supply
GENERAL
The APS-6R is a state-of-the-art, 150 watt, switching auxiliary power supply providing 24 VDC of filtered DC power. The APS-6R provides two 24 VDC output circuits, each rated for
3.0 Amps in alarm and 2.0 Amps continuous. It is used for the operation of peripheral audible/visual devices (alarm signaling appliances) for the NOTIFIER AM2020, AFP1010, NFS-3030, NFS-640, AFP-400, AFP-300, AFP-200, System 5000, and System 500 control panels.
FEATURES
• Lightweight, compact design.
• “Off-line” switching technology.
• Forward topology.
• Unique design — magnetic flux-sensed converter elimi­nates need for opto-coupler feedback.
• 120 or 240 VAC (@ 50/60 Hz) field-selectable.
• Wide input voltage range: 90 – 132 VAC, 180 – 264 VAC.
• High efficiency.
• Output circuits with overload protection.
• Built-in “brown-out” circuitry.
• Diagnostic trouble LED.
• Plug-in connector for in cabinet applications and screw ter­minals for remote device applications.
• Shares battery and charger circuit with control panel.
• Power-limited design, per UL requirements.
• Surface-mount technology conserves panel space.
• AC Fail supervision with field-selectable delay per UL 864.
• Heavy-duty clamp-type terminals accept up to 12 AWG (3.1 mm²) wire.
CONSTRUCTION AND OPERATION
When used with the CAB-3 or CAB-4 Series (CAB-A3/-A4, ­B3/-B4, -C3/-C4, or -D3/-D4), the APS-6R mounts to a CHS-4 or CHS-4L mounting chassis. If more than one APS-6R is nec­essary to satisfy Audible/Visual (DC) power requirements, con­nect additional APS-6R power supplies together as described in the Installation Instruction Manual. When used with the AFP-200, the APS-6R mounts in the lower portion of the cabi­net where batteries would normally mount (BB-17 required). When used with the System 500, only one APS-6R may be mounted in the right-most position in the cabinet.
Underwriters Laboratories requires that all Signaling Appli­ances be approved for use with the selected control system due to voltage operating range criteria. Use only those appli­ances listed for use with the associated control system. Refer
to Device Compatibility Document #15378.
DN-5952:A1 • E-121
Power Supplies
5952cov.wmf
DIMENSIONS:
6.125" (15.558 cm.) high x 4.25" (11.43 cm.) wide x 3.0" (7.62 cm.) deep at protruding edge, 2.25" (5.715 cm.) deep at box edge on opposite side.
ELECTRICAL SPECIFICATIONS
AC primary input power (TB1): 120 VAC: 120 VAC, 60 Hz,
2.5 A. 240 VAC (cut JP1): 240 VAC, 50 Hz, 1.2 A.
DC secondary input power (TB3): TB3-1 (+), TB3-2 (–).
24 VDC output power (TB2): Total 6.0 A (4.0 A continuous).
Circuit 1 (TB2-1, TB2-2; or J1): 3.0 A @ 24 VDC power-lim-
ited. Circuit 2 (TB2-3, TB2-4; or J2): 3.0 A @ 24 VDC power­limited.
Fuses: F1 (AC supervision): 250 VAC, 4.0 A, 3 AG. F2
(battery supervision): 32 VAC, 10.0 A, 3 AG.
Trouble supervision bus: J3 output: Form-A contact (open
collector). J4 input: Form-A contact (open collector).
NOTE: J3 and J4 can be interchanged.
Loss of AC indication: Immediate indication (default); 8-
hour delay (cut JP2); 16-hour delay (cut JP2 and JP3).
MECHANICAL SPECIFICATIONS
The APS-6R in its enclosure measures approximately 6" (15.24 cm) x 4" (10.16 cm) x 3” (7.62cm).
SPECIFICATIONS
Compatible with: AM2020, AFP1010, NFS-3030, NFS-640, AFC-600, AFP-400, AFP-300, AFP-200, System 5000, and System 500 control panels.
CABINETS FOR MOUNTING
CAB-3/CAB-4 Series: Use CHS-4 and CHS-4L chassis, for
AM2020, AFP1010, NFS-3030, NFS-640, AFP-400, AFP-300, and System 5000 control panels.
System 500: Can mount one APS-6R if the face module
expansion card (such as an ICE-4) is not installed.
DN-5952:A1 • 08/20/09 — Page 1 of 2
CAB-400AA: For AFP-300 and AFP-400 control panels. Mounts up to one sion card, is allowed.
AFP-200 backbox.
position of the box (where batteries mount). A BB-17 battery box is required.
APS-6R. An option module, without expan-
Mount up to one APS-6R in the lower
PRODUCT LINE INFORMATION
APS-6R: 24-volt, filtered power supply (120/220 VAC input).
EOLR-1: 12/24 VDC end-of-line relay.
CHS-4: Four-module chassis.
CHS-4L: Four-module chassis (low-profile).
Mounting APS-6R to the CHS-4 Chassis
Agency Listings and Approvals
The listings and approvals below apply to the basic APS-6R. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac­tory for latest listing status.
UL: S624
ULC: CS118/CS733/CBP696 Vol. IX
FM: Approved (AFP-200, AFP-300/400, AFC-600, NFS-
640, AFP-1010/AM2020, NFS-3030, System 500, Sys­tem 5000)
CSFM: 7315-0028:190, 7165-0028:214 (NFS-640);
7165:0028:224 (NFS-3030, NFS2-3030); 7170-0028:216 (NFS-640); 7170-0028:223 (NFS-3030, NFS2-3030)
MEA: 195-97-E Vol. II, 447-99-E (AFC-600), 317-01-E
(NFS-640), 345-02-E (NFS-3030), 232-02-E (NFS2-
3030)
5952mt1.wmf
APS-6R Assembly
APS-6R Assembly
5952assy.wmf
NOTIFIER® is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.
Page 2 of 2 — DN-5952:A1 • 08/20/09
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com
Made in the U.S. A.
Loading...