APS-6R
6.0 Amp Auxilary Power Supply
GENERAL
The APS-6R is a state-of-the-art, 150 watt, switching auxiliary
power supply providing 24 VDC of filtered DC power. The
APS-6R provides two 24 VDC output circuits, each rated for
3.0 Amps in alarm and 2.0 Amps continuous. It is used for the
operation of peripheral audible/visual devices (alarm signaling
appliances) for the NOTIFIER AM2020, AFP1010, NFS-3030,
NFS-640, AFP-400, AFP-300, AFP-200, System 5000, and
System 500 control panels.
FEATURES
• Lightweight, compact design.
• “Off-line” switching technology.
• Forward topology.
• Unique design — magnetic flux-sensed converter eliminates need for opto-coupler feedback.
• 120 or 240 VAC (@ 50/60 Hz) field-selectable.
• Wide input voltage range: 90 – 132 VAC, 180 – 264 VAC.
• High efficiency.
• Output circuits with overload protection.
• Built-in “brown-out” circuitry.
• Diagnostic trouble LED.
• Plug-in connector for in cabinet applications and screw terminals for remote device applications.
• Shares battery and charger circuit with control panel.
• Power-limited design, per UL requirements.
• Surface-mount technology conserves panel space.
• AC Fail supervision with field-selectable delay per UL 864.
• Heavy-duty clamp-type terminals accept up to 12 AWG (3.1
mm²) wire.
CONSTRUCTION AND OPERATION
When used with the CAB-3 or CAB-4 Series (CAB-A3/-A4, B3/-B4, -C3/-C4, or -D3/-D4), the APS-6R mounts to a CHS-4
or CHS-4L mounting chassis. If more than one APS-6R is necessary to satisfy Audible/Visual (DC) power requirements, connect additional APS-6R power supplies together as described
in the Installation Instruction Manual. When used with the
AFP-200, the APS-6R mounts in the lower portion of the cabinet where batteries would normally mount (BB-17 required).
When used with the System 500, only one APS-6R may be
mounted in the right-most position in the cabinet.
Underwriters Laboratories requires that all Signaling Appliances be approved for use with the selected control system
due to voltage operating range criteria. Use only those appliances listed for use with the associated control system. Refer
to Device Compatibility Document #15378.
DN-5952:A1 • E-121
Power Supplies
5952cov.wmf
DIMENSIONS:
6.125" (15.558 cm.) high x 4.25" (11.43 cm.) wide x 3.0" (7.62
cm.) deep at protruding edge, 2.25" (5.715 cm.) deep at box
edge on opposite side.
ELECTRICAL SPECIFICATIONS
AC primary input power (TB1): 120 VAC: 120 VAC, 60 Hz,
2.5 A. 240 VAC (cut JP1): 240 VAC, 50 Hz, 1.2 A.
DC secondary input power (TB3): TB3-1 (+), TB3-2 (–).
24 VDC output power (TB2): Total 6.0 A (4.0 A continuous).
Circuit 1 (TB2-1, TB2-2; or J1): 3.0 A @ 24 VDC power-lim-
ited. Circuit 2 (TB2-3, TB2-4; or J2): 3.0 A @ 24 VDC powerlimited.
Fuses: F1 (AC supervision): 250 VAC, 4.0 A, 3 AG. F2
(battery supervision): 32 VAC, 10.0 A, 3 AG.
Trouble supervision bus: J3 output: Form-A contact (open
collector). J4 input: Form-A contact (open collector).
NOTE: J3 and J4 can be interchanged.
Loss of AC indication: Immediate indication (default); 8-
hour delay (cut JP2); 16-hour delay (cut JP2 and JP3).
MECHANICAL SPECIFICATIONS
The APS-6R in its enclosure measures approximately 6"
(15.24 cm) x 4" (10.16 cm) x 3” (7.62cm).
SPECIFICATIONS
Compatible with: AM2020, AFP1010, NFS-3030, NFS-640,
AFC-600, AFP-400, AFP-300, AFP-200, System 5000, and
System 500 control panels.
CABINETS FOR MOUNTING
CAB-3/CAB-4 Series: Use CHS-4 and CHS-4L chassis, for
AM2020, AFP1010, NFS-3030, NFS-640, AFP-400, AFP-300,
and System 5000 control panels.
System 500: Can mount one APS-6R if the face module
expansion card (such as an ICE-4) is not installed.
DN-5952:A1 • 08/20/09 — Page 1 of 2
CAB-400AA: For AFP-300 and AFP-400 control panels.
Mounts up to one
sion card, is allowed.
AFP-200 backbox.
position of the box (where batteries mount). A BB-17 battery
box is required.
APS-6R. An option module, without expan-
Mount up to one APS-6R in the lower
PRODUCT LINE INFORMATION
APS-6R: 24-volt, filtered power supply (120/220 VAC input).
EOLR-1: 12/24 VDC end-of-line relay.
CHS-4: Four-module chassis.
CHS-4L: Four-module chassis (low-profile).
Mounting APS-6R to the
CHS-4 Chassis
Agency Listings and Approvals
The listings and approvals below apply to the basic APS-6R. In
some cases, certain modules may not be listed by certain
approval agencies, or listing may be in process. Consult factory for latest listing status.
• UL: S624
• ULC: CS118/CS733/CBP696 Vol. IX
• FM: Approved (AFP-200, AFP-300/400, AFC-600, NFS-
640, AFP-1010/AM2020, NFS-3030, System 500, System 5000)
• CSFM: 7315-0028:190, 7165-0028:214 (NFS-640);
7165:0028:224 (NFS-3030, NFS2-3030); 7170-0028:216
(NFS-640); 7170-0028:223 (NFS-3030, NFS2-3030)
• MEA: 195-97-E Vol. II, 447-99-E (AFC-600), 317-01-E
(NFS-640), 345-02-E (NFS-3030), 232-02-E (NFS2-
3030)
5952mt1.wmf
APS-6R
Assembly
APS-6R
Assembly
5952assy.wmf
NOTIFIER® is a registered trademark of Honeywell International Inc.
©2009 by Honeywell International Inc. All rights reserved. Unauthorized use
of this document is strictly prohibited.
Page 2 of 2 — DN-5952:A1 • 08/20/09
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.
www.notifier.com
Made in the U.S. A.