Vulcain 301W
wireless gas detection
network
Technical summary
User Friendly
• Self-contained, wall mounted enclosure
• Simple push button operation
Easy and Inexpensive to Install
• Simply wall mount (no hardwiring required)
• Turn it on and the Vulcain 301W auto configures to the
controller and is fully operational
• Unobtrusive slim-line profile
• No mounting bracket required
Few Requirements - Simple Operation
• No calibration required for two years
• No monitor hardwiring required
• No battery replacement require for two years
• After two years, simply replace the easily removed
sensor/battery pack
Input/Output Adaptability
• Allows for up to 50 remote transmitters in the system
Safety Measures
• Virtually no false alarms—accurate and reliable
• Route redundancy, so if one link fails, communication
is automatically re-established through another monitor
• Avoids interference with Bluetooth, WIFI and other
wireless systems
• Secured 128 bit encrypted wireless mesh network
• Periodic ‘heartbeat’ signal ensures all transmitters are
continuously active
Beneficial Controller Options
• Datalogging option available
• Optional BACnet/IP Output
By removing the necessity for
expensive wiring and by greatly reducing
installation costs, the Vulcain 301W can cut
the bottom line for a parking garage’s CO
(carbon monoxide) monitoring system.
The Vulcain 301W wireless gas transmitter is
designed to detect carbon monoxide (CO) and
nitrogen dioxide (NO2) in parking structures or
oxygen (O2) in other applications. It operates for 2
years without calibration, maintenance or battery
replacement. The Vulcain 301W gas transmitter
exchanges data with the Vulcain 301C controller
over a wireless mesh network via a secured 128
bit encrypted communication protocol. In contrast
to traditional networks, this system offers greater
flexibility and operational reliability together with
significant installation and operational savings.
Without the need of monitor hardwiring, installation
costs are drastically reduced—simply wall mount
the Vulcain 301W transmitter, turn it on and it is
ready for operation.
Unlike point-to-point or point-to-multipoint
communication, if the communication path fails,
the system automatically finds an alternative
route. This enables continuous contact, even
in harsh environments. The inherent network
integrity combined with zoning capabilities and
electrochemical sensor accuracy minimizes false
alarms and ultimately trims operational costs.
Zoning / Averaging
The Vulcain 301C controller offers unique zoning
capabilities which permit the averaging and
comparison of multiple sensor readings. Zoning can
reduce operational costs by ensuring that localized
brief fluctuations registered at a single transmitter
do not activate relays. For example, a car idling in
a parking structure may locally increase a reading
at a nearby transmitter. Rather than activating a fan
as a result of the temporary localized fluctuation,
zoning can be used to limit relay activation until the
average reading for a zone exceeds a set-point.
This can reduce run time of fans, yielding savings in
both energy usage and wear and tear. The Vulcain
301C has the capacity to manage input from three
Modbus channels for up to 96 transmitters and up
to 50 wireless transmitters which can be associated
with up to 126 zones. Transmitters can belong to
an unlimited number of zones, providing maximum
operational and control flexibility.
Vulcain 301W General Specification
Uses
the Vulcain 301C controller.
Power Requirement Battery operated with 2 years (minimum)
Size 22.5 x 10 x 5.7 cm (8.85 x 4 x 2.25 in.)
Weight 0.4 kg (0.88 lb.)
Sensing Technology Electrochemical
Network Capacity 50 wireless transmitters to the Vulcain 301C
Visual Indicators Two LEDs
Radius of Detection 15.24 m (50 ft.)
Calibration Not required for 2 years
Communication Protocol 2.4 Ghz - IEEE 802.15.4 - Secured 128-bit encryption
Alarms Centralized alarm management via Vulcain 301C wireless controller
Ratings and Certifications:
Conforms to
Certified to CAN/CSA C22.2 No. 61010-1
FCC Part 15 Subpart C(15.247)
RSS 210 Section 6.2.2(o)
Enclosure NEMA 4X Polycarbonate – ABS
Vulcain 301C General Specification
Uses
sensors (up to 50 Vulcain 301W transmitters) with relays for effective response to hazard(s) present (activation of ventilation
fans, audible and/or visual alarms, etc).
Power Requirement 17-27 Vac, 24-38 Vdc, 500 mA
Size 28 x 20.3 x 7 cm (11.02 x 7.99 x 2.76 in.)
Weight 1.1 kg (2.4 lb.)
Network Capacity Three Modbus channels for up to 96 wired transmitters and up to 50 wireless transmitters
Optional BACnet capacity
Communication Line Lengths Up to 609 m (2000 ft.) per channel
(RS-485) T-Tap: 20 m (65 ft.), maximum per T-Tap
40 m (130 ft.) maximum for all T-Tap combined
30 m (100 ft.) between each 301W
Relay Output Rating 5 A, 30 Vdc or 250 Vac (resistive load)
Alarm Levels 3 fully programmable alarm levels
Time Delays 0, 30 sec., 45 sec., 1-99 minutes before and after alarm; latchable
Outputs 4 DPDT relays (alarms and/or fault); 65dBA buzzer
Display Large 122 x 32 dot matrix display
Operating Humidity
Operating Temperature -20 to 50°C (-4 to 122°F)
Ratings and Certifications:
Certified to CAN/CSA C22.2 No 61010-1
116662
Conforms to ANSI/UL 61010-1
IEC 61010-1 Including Amendments A1:1992 +
A2:1995 and National Deviations (Canada, US)
Wall mounted, wireless gas detector for carbon monoxide (CO) hazards, to be used in conjunction with
ANSI/UL 61010-1
Wall mounted gas detection control panel for the annunciation of gas hazards detected by the complete range of Vulcain
0-95% RH, non-condensing