Notifier 301C User Manual

Vulcain 301C
SECONDARY HEADLINE
Continuously monitor and control toxic gases, combustible gases and oxygen hazards
Vulcain 301C digital gas detection controller
User Friendly
• Zero maintenance
• Automatic quick self-test and warm-up
• Continuous alphanumeric display
Inexpensive and Reliable
• Low installation costs
• Allows for up to 126 zoning groups which can save energy and extend fan and relay life
• Manages up to 768 events with programmable latching alarms
Flexible Operation
• Modbus compatible; with BACnet/IP available
• Interchangeable transmitters able to detect different gases
• Expands to handle up to 96 transmitters or relay modules and up to 50 Vulcain 301W wireless sensors
• Programmable time delays
• Integrated time clock enables scheduling of system operations
Safety Measures
• Full array of visual indicators and integrated 65dBA alarm levels
• Fully programmable relays (can be set as fail-safe or not)
Beneficial Options
• Available in a heavy duty industrial housing
• Datalogging option
Using an addressable RS-485 Modbus communication protocol, the Vulcain 301C uses daisy chain wiring requiring only 2 pairs of wires to connect up to 96 transmitters on the 3 input channels. This simplifies installation, in turn lowering costs. The 301C’s zoning and averaging abilities significantly reduce operational and maintenance costs.
Zoning / Averaging
The Vulcain 301C controller offers unique zoning capabilities which permit the averaging and comparison of multiple sensor readings. Zoning can reduce operational costs by ensuring that localized brief fluctuations registered at a single transmitter do not activate relays. For example, a car idling in a parking structure may locally increase a reading at a nearby transmitter. Rather than activating a fan as a result of the temporary localized fluctuation, zoning can be used to limit relay activation until the average reading for a zone exceeds a set-point. This can reduce run time of fans, yielding savings in both energy usage and wear and tear. The Vulcain 301C has the capacity to manage input from three Modbus channels for up to 96 transmitters and up to 50 wireless transmitters which can be associated with up to 126 zones. Transmitters can belong to an unlimited number of zones, providing maximum operational and control flexibility.
Technical summary
General Specifications Use Modbus controller for centralized gas detection monitoring with real-time gas reading, selective alarm activation and low
cost of installation.
Size 28 x 20.3 x 7 cm (11.02 x 7.99 x 2.76 in.) Weight 1.1 kg (2.4 lb.) Enclosure NEMA 4X Polycarbonate – ABS Power Requirement 17-27 Vac, 24-38 Vdc, 500 mA Network Capacity Three Modbus channels for up to 96 transmitters, one wireless channel for up to 50 301W wireless transmitters and an
optional BACnet/IP output
Communication Line Up to 609 m (2000 ft.) per channel Lengths T-Tap: 20 m (65 ft.), maximum per T-Tap
40 m (130 ft.), maximum for all T-Tap combined
Relay Output Rating 5 A, 30 Vdc or 250 Vac (resistive load) Alarm Levels 3 fully programmable alarm levels Time Delays 0, 30 sec., 45 sec., 1-99 minutes before and after alarm Outputs 4 DPDT relays (alarms and/or fault); 65dBA buzzer Display Large 122 x 32 dot matrix display Operating Humidity Range 0-95% RH, non-condensing Operating Temperature -20 to 50°C (-4 to 122°F)
Range Ratings and Certifications
Certified to CAN/CSA C22.2 No 61010-1
116662 Conforms to ANSI/UL 61010-1
IEC 61010-1 Including Amendments A1:1992 + A2:1995 and National Deviations (Canada, US)
As world leaders in gas detection solutions, Honeywell Analytics’ Vulcain range of gas detection systems has been designed to provide efficient, practical and cost-effective equipment to protect people from a variety of forms of hazardous gases and to efficiently monitor and control indoor air quality. The equipment is also extremely simple to install and easy to operate and maintain.
The Vulcain range of fixed gas detection and air monitors
GasPoint II
Vulcain Sensors
From refrigerants to toxic and combustible gases, Honeywell Analytic’s Vulcain line has a sensor designed for any industrial or commercial application. With award winning sensor technology, this line of sensors is the answer to any fixed HVAC, IAQ or gas detection concerns.
Find out more
For more information on Honeywell Analytic’s Vulcain line of products, visit www.honeywellanalytics.com or contact us at 800 563 2967
Customer business center Canada
Honeywell Analytics 4005 Matte Blvd., Unit G Brossard, QC, Canada J4Y 2P4 Toll free: +1 800 563 2967 Tel: +1 450 619 2450 Fax: + 1 888 967 9938 detectgas@honeywell.com www.honeywell.com
Customer business center USA, Central and South America
Honeywell Analytics Suite 100 400 Sawgrass Corporate Parkway Sunrise, FL 33325 Tel: +1 954 514 2700 Toll free: +1 800 538 0363 Fax: +1 954 514 2784 detectgas@honeywell.com www.honeywell.com
Vulcain 301WVulcain 201TVulcain 301RLC
Vulcain 301M
Stand-Alone Dual Gas Monitor
For applications where gas detection is only needed at one or two points, the Vulcain 301M offers a simple solution. While continually monitoring for CO, a remote sensor can also be integrated to detect CO, NO sensor that can be place up to 200’ away.
Vulcain 90DM
Commercial CO2 Detection
Using proven infrared dual sensing technology to detect carbon dioxide (CO mounted to monitor CO
, propane, hydrogen or methane with a remote
2
4
) the Vulcain 90DM4 can be either wall or duct
2
levels in you commercial environment.
2
Vulcain 301C Vulcain 301EM
Vulcain Controllers
Designed for industrial or commercial use, the Vulcain 301C monitors and controls toxic gases, combustible gases and oxygen hazards. With the same simple installation and operation and flexibility as the Vulcain 301C, the Vulcain 301EM is specifically designed to fulfil the requirements of a mechanical room.
Customer business centre Europe and the rest of the world
Honeywell Analytics Wilstrasse 11-U11 CH-8610 Uster Switzerland Tel: +41 (0) 44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com www.honeywell.com
H_301C_DS01005_V1 September 2006 ©2006 Honeywell Analytics
Loading...