Noshok Noshok 800 Series Platinum Resistance Temperature Transmitters Manual

Page 1
200 Series
Voltage Output Pressure Transducer
300 Series
Compact OEM Pressure
Transmitter/Transducer
612 & 613 Series
Submersible Level
Transmitter/Transducer
615 & 616 Series
High Accuracy Heavy-Duty
Pressure Transmitter/Transducer
640 Series
Precision Heavy Duty
Pressure Transmitter/Transducer
Electrical Installation:
4 mA to 20 mA Output
DIN EN 175301-
803 Form C
6-Pin Bayonet M12x1 (4-Pin)
3-Wire Cable
+ Shield
4-Pin Bayonet
Voltage output, 3-wire
200 Series
CONNECTION TYPE (CODE) V+ COMMON OUTPUT
DIN EN 175301-803 Form C (7) 1 2 3
DIN EN 175301-803 Form C w/ Cable
1/2" NPT Conduit w/ Cable (6) Red Black White
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable (36) Red Black White
0-5 Vdc, 1-5 Vdc, 1-6 Vdc,
0-10 Vdc, 1-11 Vdc
(1) Red Black White
DIN EN 175301-803
Form A
2-Wire Cable
+ Shield
3-Wire Cable
DIN EN 175301-
+ Shield
Current output, 2-wire
300 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V-
DIN EN 175301-803 Form A (8 or 14),
DIN EN 175301-803 Form C (7)
DIN EN 175301-803 Form A w/ Cable (1) Red Black
M12 x 1, 4-Pin (25) 1 3
Integral Cable, Unshielded (36) Brown Blue
Voltage output, 3-wire
300 Series
CONNECTION TYPE (CODE) V+ COMMON OUTPUT
DIN EN 175301-803 Form A (8 or 14),
DIN EN 175301-803 Form C (7)
DIN EN 175301-803 Form A w/ Cable (1)
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable, Unshielded (36) Brown Blue Black
0-5 Vdc, 1-5 Vdc, 1-6 Vdc,
Red Black White
803 Form C
M12x1 (4-Pin)
1 2
0-10 Vdc, 1-11 Vdc
1 2 3
2-Wire Cable
+ Case Ground
NOTE: Vent tube included for atmospheric compensation.
3-Wire Cable
+ Case Ground
Current output, 2-wire
612 & 613 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V- CASE GROUND
PUR Cable Brown Green Gray
FEP Cable Brown White Blue
Voltage output, 3-wire
612 & 613 Series
CONNECTION TYPE
(CODE)
PUR Cable Brown Green White Gray
FEP Cable Brown Green White Gray
0-5 Vdc, 0-10 Vdc,
0.5 to 2.5 Vdc
V+ COMMON OUTPUT CASE GROUND
DIN EN 175301-803
Form A
6-Pin Bayonet
2-Wire Cable
+ Shield
3-Wire Cable
M12x1 (4-Pin)
+ Shield
Current output, 2-wire
615 & 616 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V-
DIN EN 175301-803 Form A (8 or 14) 1 2
DIN EN 175301-803 Form A w/ Cable (1) Red Black
6-Pin Bayonet (3) A B
1/2" NPT Conduit w/ Cable (6) Red Black
M12 x 1, 4-Pin (25) 1 3
Integral Cable (36) Red Black
Voltage output, 3-wire
615 & 616 Series
CONNECTION TYPE (CODE) V+ COMMON OUTPUT
DIN EN 175301-803 Form A (8 or 14) 1 2 3
DIN EN 175301-803 Form A w/ Cable (1)
6-Pin Bayonet (3) A B C
1/2" NPT Conduit w/ Cable (6) Red Black White
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable (36) Red Black White
0-5 Vdc, 1-5 Vdc, 1-6 Vdc,
0-10 Vdc, 1-11 Vdc
Red Black White
M12x1 (4-Pin)
2-Wire Cable
+ Shield
3-Wire Cable
+ Shield
Current output, 2-wire
640 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V-
M12 x 1, 4-Pin (25) 1 3
Integral Cable (1) Brown Blue
Voltage output, 3-wire
640 Series 0-5 Vdc, 0-10 Vdc, 0-20 mA
CONNECTION TYPE (CODE) V+ COMMON OUTPUT
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable (1) Brown Blue Black
3-Wire Voltage Output
V+ = Supply Voltage V- = 4 mA to 20 mA Signal Output = Voltage Output Signal Common = Supply Voltage Return/Ground
Load Limitations:
4 mA to 20 mA Output Only Vmin = 10V + (.020 x RL) RL = RS + RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wire Resistance (ohms)
Load Limitations (612 & 613 Only):
4 mA to 20 mA Output Only Vmin = [10V + (.020 x RL)] - RC
RL = RS + RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms) RC = 0.0435 x cable length (ft.)
Ft.
Page 2
660 Series
High Performance Micro-Size
Pressure Transmitter/Transducer
DIN EN 175301-
803 Form C
+ Shield
Current output, 2-wire
660 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V-
DIN EN 175301-803 Form C (7) 1 2
DIN EN 175301-803 Form C w/ Cable
M12 x 1, 4-Pin (25) 1 3
Integral Cable (36) Brown Green
Voltage output, 3-wire
660 Series 1-5 Vdc, 0.1-10 Vdc
CONNECTION TYPE (CODE) V+ COMMON OUTPUT
DIN EN 175301-803 Form C (7) 1 2 3
DIN EN 175301-803 Form C w/ Cable (1)
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable (36) Brown Green White
2-Wire Cable
+ Shield
M12x1 (4-Pin)
(1) Red Black
Red Black White
800 Series
Temperature Transmitter/Transducer
DIN EN 175301-803 Form A (8 or 14) 1 2
DIN EN 175301-803 Form A w/ Cable (1) Red Black
DIN EN 175301-803 Form A (8 or 14) 1 2 3
DIN EN 175301-803 Form A w/ Cable (1)
Platinum Resistance
DIN EN 175301-803
Form A
3-Wire Cable
+ Shield
Current output, 2-wire
800 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V-
M12 x 1, 4-Pin (25) 1 3
Voltage output, 3-wire
800 Series 0-10 Vdc
CONNECTION TYPE (CODE) V+ COMMON OUTPUT
M12 x 1, 4-Pin (25) 1 3 4
2-Wire Cable
+ Shield
M12x1 (4-Pin)3-Wire Cable
Red Black White
810 Series
Compact Temperature Transmitter
M12x1 (4-Pin)
Current output, 2-wire
810 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V-
M12 x 1, 4-Pin (25) 1 3
Installation Information:
NOSHOK pressure & temperature transmitters/ transducers may be mounted in any plane with
negligible effect on performance. Although these units are designed and manufactured to withstand substantial shock and vibration, it is recommended that they be mounted in an area of minimal
vibration. Always use a wrench on the wrench ats
when installing. NEVER use a pipe wrench on the housing or in the area of the electrical connection.
Maintenance/Calibration:
NOSHOK pressure and temperature transmitters/ transducers require no maintenance. Recalibration
is dependent on the users Quality Assurance Program. If no program is in place, NOSHOK recommends a 1 year cycle.
Alignment Procedure (applies only to 100, 200, 615/616, and 640 series):
Using a pressure source and meter with adequate accuracy, perform the following steps:
• Open sensor
• With no pressure applied, adjust the “Z” potentiometer for the correct Zero output
• Apply the correct full scale pressure to the unit
• Adjust the “S” potentiometer for the correct Span output
Span
Zero
www.noshok.com
Transmitters/Transducers
Wiring Diagrams
100 Series
Current Output Pressure Transmitter
DIN EN 175301-
803 Form C
6-Pin Bayonet
2-Wire Cable
+ Shield
Current output, 2-wire
100 Series 4 mA to 20 mA
CONNECTION TYPE (CODE) V+ V-
DIN EN 175301-803 Form C (7) 1 2
DIN EN 175301-803 Form C w/ Cable
4 or 6-Pin Bayonet (2 or 3) A B
1/2" NPT Conduit w/ Cable (6) Red Black
M12 x 1, 4-Pin (25) 1 3
Integral Cable (36) Red Black
1010 West Bagley Road • Berea, Ohio 44017
440-243-0888 • Fax 440-243-3472
E-mail: noshok@noshok.com • Web: www.noshok.com
4-Pin Bayonet
M12x1 (4-Pin)
(1) Red Black
NWD 08-8-2
Loading...