All rights to these operating instructions are reserved. These operating instructions, including
extracts thereof, must not be copied or translated into other languages without our written
permission.
Safety Instructions and Warnings
Please read these instructions before installing and starting up the pressure switch. Failure to
follow the instructions will make all guarantee, warranty and compensation claims null and
void.
connection, and the correct tools must always be used.
complied with.
• Damaged devices must not be started up. If damage occurs during operation, suitable
measures must be taken to prevent persons or property from being put at risk by the damaged
pressure switch.
• The switch must only be repaired by NOSHOK.
temperature
temperature
The accepted technical regulations and all national guidelines must always be observed and
complied with.
1
Page 3
Exclusion of Liability
NOSHOK guarantees that the pressure switch is in perfect working condition when it is delivered.
The basis consists of the technical data in the data sheet and these operating instructions.
Liability cannot be accepted for the suitability of the pressure switch.
Electrical and Mechanical Connection
The technical regulations must be complied with during installation and dismantling.
The system must be depressurized prior to installation and dismantling.
Safety regulations must be complied with, particularly when working on the electrical
system. All connections to external electrical equipment must be made in accordance with
regulations.
The power to system must always be swittch is being connected.
Temperature Switch Description
The temperature switch has one analog output and one switching output or two switching outputs. The switching output(s) is (are) adjusted using the two buttons: set point, reset point
(hysteresis), switching function (normally closed/normally open contact).
The programmable analog output is a special feature. It can be adjusted in 0.1° steps within a
span of at least 20% of the temperature range.
2
Page 4
+Supply
S1
1
-Supply
2
3
4
R
L
Sig
+Supply
S1
1
-Supply
2
3
4
S2
R
1
R
2
Round Connector M 12 x 1 (4-pin)
SignalConnectorColors of
Optional Wires
Supply: +1brown
Supply: -3blue
Switch output S 14black
Switch output S 2 or
2white
analog output
Recommended accessories:
M12x1 socket with 2m cable
• straight version, order no.: FS-2-4P
• angled version, order no.: FA-2-4P
switching to p potential
1 switching output and 1 analog output 2 switching outputs
3
Page 5
Switching On and Off
Status-LED Switching Output
1 2
The temperature switch is switched on when the supply voltage is applied. There is no on/o
switch. A brief initialization phase occurs when the supply voltage is applied to the switch. The
display and the set point LED illuminate. The measuring range (min- and max. temperature) and
the unit are indicated briey. The outputs are inactive during this time.
After initialization the switch is in normal operating mode. The temperature appears on the display,
the switching outputs are active and the LED’s indicate the status of the switching outputs.
Programming
Briey pressing button S1 or S2 causes the relevant set point to be displayed.
The status LED’s ash for as long as the set points are being displayed.
Pressing the buttons for longer (press and hold down button until display ashes) causes the
current temperature to be taken over as the set point. The hysteresis remains unchanged. The
switching output(s) can be programmed using the control buttons independently from the present
temperature, per the programming sequence on page 6.
The programming sequence must run without interruptions. If delays of about 20 seconds or
more occur, the switch automatically exits programming mode and switches to normal mode.
All previous changes are lost.
4
Page 6
Parameter description / programming
With two switching outputs
Temperature units
Degree Celsius
Degree Fahrenheit
Switch 1, Set Point Select set point for rst switch
Switch 1, Reset Point Select reset point for rst switch
Contact 1Select contact function for rst switch
normally openSelect normally open contact
normally closedSelect normally closed contact
Switch 2, Set Point Select set point for second switch
Switch 2, Reset Point Select reset point for second switch
Contact 2Select contact function for second switch
normally openSelect normally open contact
normally closedSelect normally closed contact
Store
1) The pressure units setting applies immediately for the switching point settings, the reset points
and for the process pressure 4-digit LED display.
The previous changes are only accepted if button 2 is
pressed about 15 seconds after the previous button press!
5
Page 7
6
Page 8
With one switching output and one analog output
Temperature units
Degree Celsius
Degree Fahrenheit
Switch 1, Set PointSelect set point for rst switch
Switch 2, Reset PointSelect reset point for rst switch
Contact 1Select contact function for rst switch
Normally openSelect normally open contact
Normally closedSelect normally closed contact
Current highSelect temperature value for 20mA
Current lowSelect temperature value for 4mA
StoreThe previous changes are only accepted if button 2 is
1) The pressure units setting applies immediately for the switching point settings, the reset points
and for the process pressure 4-digit LED display.
pressed about 15 seconds after the previous button press!
7 8
Page 9
Page 10
Technical data
Temperature Ranges-58 to +392°F
Measurement Units°C or °F (selectable)
SensorPT100 class B or PT100 class A
Supply Voltage12...30 Vdc, overload and reverse polarity protection
Power Consumption≤ 50mA, without load current
Process Connections
• Fixed Thread
• Compression Fitting
Materials
• Process Connection
• Housing
Stem and
Working Pressure
Outputs2 switching outputs PNP or
-58 to +752°F
-58 to +1112°F
-328 to +1112°F
ripple <10%
1/2NPT, 1/4NPT
1/2NPT
Other connections on request
Stainless steel 1.4571 (316Ti); other materials or coatings on request
Stainless steel, display cover plastic
• from stem length (EL) 50mm: ø6 x 0.75mm (up to 40 bar)
• from EL 50mm: ø8 x 1.75mm (up to 100 bar)
• from EL 50mm: Special parts made of solid material (up to 500 bar)
Fast response time version (up to 12 bar)
• EL 25mm: ø3 x 0.25mm without taper
• EL up to 100mm: ø6 x 0.25mm with taper to ø3 x 0.25mm
• from EL 100mm: ø8 x 1.75mm with taper to ø6 x 0.25mm with taper
to ø3 x 0.25mm
1 switching output PNP and analog output 4…20mA
9
Page 11
Switching outputs
A
V
.022
7U
R
Supply
−
=
• Switching function
• Switching rating
• Adjustment
- Set Point
- Reset point
Analog output
Signal
adjustable normally closed (NC) or normally open (NO) contact
100mA per switching output
Programmable via the display
0.1° steps withhin temperature range
0.1° steps from beginning temperature range until max. set point –0.1°
4…20mA; 2-wire, programmable in 0.1° steps,
span at least 20% of the temperature range
Load resistance
Dependent on the supply voltage; the relevant formula is
Display4-digit 7-segment LED display, red, 7.6mm high
AccuracySwitching output, analog output and Display:
Accuracy of PT100 + 0,1% of the temperature range
Repeatability0.05%
Electrical connectionM12 x 1 (4-Pin)
Temperature range
Storage
Ambient
Thermal Eect
EMV to IEC /
EN 61 326
-22...+176°F
-13...+158°F
0.006% of Full Scale/°F
IEC 61000/4/2 ESD: B
IEC 61000/4/3 HF: A
IEC 61000/4/4 Burst: A
IEC 61000/4/5 Surge: A
IEC 61000/4/6 HF: A
Protection classIP65 according IEC 529
Weight0.66 lbs.
10
0
Page 12
DIMENSIONS Inches (mm)
11
Page 13
CE – Conformity
Remove the device as soon as device malfunctions start to occur. The internals cannot be
maintained by the customer. Replace the device or return it to the manufacturer to have it
tested.
The switch complies with all requirements of EN 61 326 with regard to interference emission and
immunity for use in industrial areas. NOSHOK recommends the use of shielded cables. Installation
and cable routing must be carried out correctly in order to maintain the eective protection from
electromagnetic interference.
Maintenance
The temperature switches that are described in this document are maintenance free. The equipment will also operate in a stable state for long periods, meaning that regular adjustment or the
like is not required.
12
Page 14
Cleaning
The exterior of the 850 Series Temperature Switch can be cleaned using a soft, moistened cloth. Heavy
soiling can be removed using a mild cleaning agent.
The switch must not be opened for cleaning!
Aggressive chemicals or hard scrubbing can damage the surface, particularly the display lm.
Disposal
The packaging and used parts must be disposed of in accordance with the regulations of the
country in which the device is installed.
13