NoShok 615, 616 Operating Manual

Page 1
Installation:
NOSHOK pressure transmitters/transducers may be mounted in any plane with negligible effect on performance. Although these units are designed and manufactured to withstand substantial shock and vibration, it is recommended that they be mounted in an area of minimal vibration. Always use a wrench on the wrench flats when installing. NEVER use a pipe wrench on the housing or in the area of the electrical connection.
Maintenance/Calibration:
NOSHOK pressure transmitters/transducers require no maintenance. Recalibration is dependent on the users Quality Assurance Program. If no program is in place, NOSHOK recommends a 1 year cycle.
Alignment Procedure (applies only to 100, 200, 615/616, and 640 series):
Using a pressure source and meter with adequate accuracy, perform the following steps:
• Open sensor
• With no pressure applied, adjust the “Z” potentiometer for the correct Zero output
• Apply the correct full scale pressure to the unit
• Adjust the “S” potentiometer for the correct Span output
NWD 08-3
Span
Zero
NOSHOK
TRANSMITTERS
TRANSDUCERS
Wiring Diagrams & Electrical
Connections for:
100, 200, 300, 612, 613, 615/616,
CORPORATE HEADQUARTERS
1010 West Bagley Rd. • Berea, OH 44017
440.243.0888 • FAX 440.243.3472 E-mail: noshok@noshok.com Web: www.noshok.com
Page 2
SERIES 100 SERIES 200
Current output, 2 wire
Power Supply
Output
+ Supply
+ Output
M12 x 1 4-pin
round connector
Red
Power
Supply
Black
Output
2 WIRE
WIRING DIAGRAM EXAMPLE
Wiring ­Mini-Hirschmann
1
2
connector
Power Supply
+ Supply
3
Wiring -
Output
+ Output
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
R
L = RS + RW
RL = Loop Resistance (ohms)
R
S = Sense Resistance (ohms)
R
W = Wire Resistance (ohms)
Series 100 4 mA to 20 mA
CONNECTION TYPE
(CODE)
Mini-Hirschmann
(7)
Mini-Hirschmann
w/ Cable (1)
4 or 6 Pin Bendix
(2 or 3)
1/2" NPT Conduit
w/ Cable (6)
M12 x 1, 4-Pin (25) 1 3
Integral Cable (36) Red Black
+ SUPPLY + OUTPUT
1 2
Red Black
A B
Red Black
Voltage output, 3 wire
Power
Supply
Output
L)
Series 200
CONNECTION TYPE
Mini-Hirschmann
Mini-Hirschmann
w/ Cable (1)
4 or 6 Pin Bendix
(2 or 3)
1/2" NPT Conduit
w/ Cable (6)
M12 x 1,
4-Pin (25)
Integral Cable
+ Supply
1
3
2
+ Output
Common
Wiring -
M12 x 1 4-pin
round connector
3 WIRE WIRING
DIAGRAM EXAMPLE
0-5 Vdc, 1-5 Vdc,
1-6 Vdc,
0-10 Vdc, 1-11 Vdc
(7)
+ SUPPLY COMMON + OUTPUT
1 2 3
Red Black White
A B C
Red Black White
1 3 4
Red Black White
(CODE)
(36)
Wiring ­Mini-Hirschmann connector
Power Supply
Output
Red
Power Supply
Black
+ Supply
+ Output
Common
White
Output
Page 3
SERIES 300 SERIES 612 & 613
2 WIRE WIRING
DIAGRAM EXAMPLE
Series 300 4 mA to 20 mA
CONNECTION TYPE (CODE) + SUPPLY + OUTPUT
Hirschmann
(7, 8 or 14)
Hirschmann w/ Cable (1)
M12 x 1, 4-Pin (25) 1 3
Integral Cable (36) Brown Blue
1 2
Red Black
Power Supply
Red
Black
Output
2 WIRE WIRING
DIAGRAM EXAMPLE
Series 612/613 4 mA to 20 mA
CONNECTION TYPE + SUPPLY + OUTPUT CASE GROUND
Cable Red Black Blue
Power Supply
Red
Blue
Black
Output
Load Limitations 4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R R
L = RS + RW
L)
RL = Loop Resistance (ohms) R
S = Sense Resistance (ohms)
R
W = Wire Resistance (ohms)
3 WIRE WIRING
DIAGRAM EXAMPLE
Series 300
CONNECTION TYPE
Hirschmann
(7, 8 or 14)
Hirschmann w/ Cable (1)
M12 x 1,
4-Pin (25)
Integral Cable
0-5 Vdc, 1-5 Vdc, 1-6 Vdc,
(CODE)
+ SUPPLY COMMON + OUTPUT
(36)
Brown Blue Black
0-10 Vdc, 1-11 Vdc
1 2 3
Red Black White
1 3 4
Power
Supply
Black
Load Limitations 4 mA to 20 mA Output Only
Vmin = [10V + (.020 x R
RL = RS + RW
L)] - O.04354 x
cable length
Ft.
RL = Loop Resistance (ohms) R
Red
White
Output
S = Sense Resistance (ohms)
R
W = Wire Resistance (ohms)
Power Supply
Red
Black
Blue
White
3 WIRE WIRING
DIAGRAM EXAMPLE
Series 612/613
CONNECTION
TYPE
Cable Red Black White Blue
0-5 Vdc, 0-10 Vdc,
0.5 to 2.5 Vdc
+ SUPPLY COMMON + OUTPUT
CASE
GROUND
Output
Page 4
SERIES 615/616
Red
Power
Supply
Load Limitations 4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R R
L = RS + RW
RL = Loop Resistance (ohms) R
S = Sense Resistance (ohms)
R
W = Wire Resistance (ohms)
Series 615/616
CONNECTION TYPE
(CODE)
Hirschmann
(8 or 14)
Hirschmann w/ Cable (1)
6 Pin Bendix (3) A B C
1/2" NPT Conduit
w/ Cable (6)
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable (36) Red Black White
Black
Output
DIAGRAM EXAMPLE
Series 615/616 4 mA to 20 mA
CONNECTION TYPE (CODE) + SUPPLY + OUTPUT
Hirschmann
(8 or 14)
Hirschmann w/ Cable (1)
6 Pin Bendix (3) A B
1/2" NPT Conduit
w/ Cable (6)
M12 x 1, 4-Pin (25) 1 3
Integral Cable (36) Red Black
L)
DIAGRAM EXAMPLE
0-5 Vdc, 1-5 Vdc,
1-6 Vdc,
0-10 Vdc, 1-11 Vdc
+ SUPPLY COMMON + OUTPUT
1 2 3
Red Black White
Red Black White
2 WIRE WIRING
1 2
Red Black
Red Black
3 WIRE WIRING
Red
Power
Supply
Black
White
SERIES 640
Current output, 2 wire
+ Supply Power Supply
Output
+ Output
Voltage output, 3 wire
+ Supply
Power
Supply
Output
+ Output
Common
RS 232 Interface
Output
Series 640 0-5 Vdc, 0-10 Vdc, 0-20 mA
CONNECTION TYPE (CODE) + SUPPLY COMMON + OUTPUT
Hirschmann (8 or 14) 1 2 3
Hirschmann w/ Cable (1) Red Black White
6 Pin Bendix (3) A B C
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable (36) Brown Black Blue
Wiring - M12 x 1 4-pin
round connector
Series 640 4 mA to 20 mA
CONNECTION
TYPE (CODE)
Hirschmann
(8 or 14)
Hirschmann w/ Cable (1)
6 Pin Bendix (3) A B
M12 x 1,
4-Pin (25)
Integral Cable (36) Brown Blue
Load Limitations 4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R R
L = RS + RW
RL = Loop Resistance (ohms) R
S = Sense Resistance (ohms)
R
W = Wire Resistance (ohms)
Pressure Sensor
+ SUPPLY + OUTPUT
1 2
Red Black
1 3
L)
Page 5
SERIES 660
Wiring - Mini-Hirschmann connector
Current output, 2 wire
+ Supply
Power
Supply
Output
+ Output
1
3
2
Load Limitations 4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R R
L = RS + RW
RL = Loop Resistance (ohms) R
Voltage output, 3 wire
Power
Supply
Output
Series 660 4 mA to 20 mA
CONNECTION TYPE (CODE) + SUPPLY + OUTPUT
Mini-Hirschmann (7) 1 2
Mini-Hirschmann w/ Cable (1) Red Black
M12 x 1, 4-Pin (25) 1 3
Integral Cable (36) Brown Green
+ Supply
+ Output
Common
1
3
2
S = Sense Resistance (ohms)
R
W = Wire Resistance (ohms)
Wiring - M12 x 1 4-pin round connector
Current output, 2 wire
+ Supply
Power
Supply
L)
Output
Voltage output, 3 wire
Power
Supply
Output
Series 660 1-5 Vdc, 0.1-10 Vdc
CONNECTION TYPE (CODE) + SUPPLY COMMON + OUTPUT
Mini-Hirschmann (7) 1 2 3
Mini-Hirschmann w/ Cable (1) Red Black White
M12 x 1, 4-Pin (25) 1 3 4
Integral Cable (36) Brown Green White
+ Output
+ Supply
+ Output
Common
Page 6
SERIES 800
4 mA to 20 mA, 2 wire
Power Supply
+ Supply
Load Limitations
Output
+ Output
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R R RL = Loop Resistance (ohms) R R
Series 800 4 mA to 20 mA
CONNECTION TYPE (CODE) + SUPPLY + OUTPUT
Hirschmann (8 or 14) 1 2
Hirschmann w/ Cable (1) Red Black
M12 x 1, 4-Pin (25) 1 3
L = RS + RW
L)
S = Sense Resistance (ohms) W = Wire Resistance (ohms)
Series 800 0-10 Vdc
CONNECTION TYPE (CODE) + SUPPLY COMMON + OUTPUT
Hirschmann (8 or 14) 1 2 3
Hirschmann w/ Cable (1) Red Black White
M12 x 1, 4-Pin (25) 1 3 4
0 Vdc to 10 Vdc, 3 wire
Power
Supply
Output
+ Supply
+ Output
Common
Loading...