Level
Cage-Protected Submersible Level Transmitters
613 SERIES
• Designed for severe high solids environments such as sewage, lift stations, storm canals, wet
wells and slurry tanks where sludge, slurry or turbulence may be present
• Ideal for a wide variety of industrial and municipal liquid level measurement applications
requiring watertight protection
• Welded at cap and base to provide a leak-tight seal
• Highly accurate, shock resistant and extremely stable over long periods of time
• Standard 1/2″ NPT conduit for attaching lifting rings or mounting brackets
• Advanced diffused semi-conductor and sputtered thin fi lm sensor for maximum stability
• Ranges from 0 inH
• Corrosion resistant 316L stainless steel construction
• Reverse polarity protection and short circuit protection are standard
• Optional 5 to 30 Vdc input for 0.5 to 2.5 Vdc output, for fi eld applications
• Optional integrated temperature measurement (PT100 RTD)
O to 50 inH2O through 0 psi to 300 psi (higher ranges available on request)
2
FEATURES
■ Advanced diffused semi-
conductor and sputtered
thin film sensor for
maximum stability
■ High accuracy and long
term stability
■ Ranges from 0 inH
50 inH2O through
0 psi to 300 psi
■ Corrosion resistant
stainless steel construction
■ Optional 5 -30 Vdc input
for 0.5 to 2.5 Vdc output,
for field applications
■ Optional integrated
temperature measurement
(PT100 RTD)
2
O to
APPLICATIONS
■ Sewage
■ Lift stations
■ Storm canals
■ Wet wells
■ Slurry tanks
SPECIFICATI ONS
Output signals 4 mA to 20 mA, 2-wire; 0 Vdc to 5 Vdc and 0 Vdc to 10 Vdc, 3-wire;
Pressure ranges 0 in H
Proof pressure 2 times range
Burst pressure 4 times range
Accuracy ± 0.25% full scale (BFSL); optional ± 0.125% full scale (BFSL);
Repeatability ≤ ± 0.05% full scale
Electrical connection
Hysteresis ≤ ± 0.1% full scale
Stability ≤ ± 0.2% full scale for 1 year, non-accumulating
Load limitations ≤ (VPower-10)/0.020 Amp for 4 mA to 20 mA
Wetted materials Housing: 316 stainless steel
Power supply* 10 Vdc to 30 Vdc (4 mA to 20 mA, 2-wire)
Temperature ranges Compensated 32 °F to 122 °F (0 °C to 50 °C)
Temperature measurement
Response time ≤ 1 ms (between 10% and 90% full scale)
Environmental protection NEMA 6P, IP68
Electromagnetic rating 2004/108/EEC, EN 61326 Emission (Group 1, Class B) and Immunity
Electrical protection Reverse polarity protection, short circuit and optional lightning protection
Shock
Vibration
Weight Approximately 3.2 lb. - cable extra
0.5 Vdc to 2.5 Vdc, 3-wire
O to 50 in H2O through 0 psig to 300 psig
2
(includes the effects of non-linearity, hysteresis, non-repeatability, zero point
and full scale errors)
Submersible 1/2
≥ 10,000 Ω for 0 Vdc to 10 Vdc, 3-wire
≥ 5,000 Ω for 0 Vdc to 5 Vdc, 3-wire
Cage seal: All 316 stainless steel
Cable: Polyurethane, FEP available on special versions
10 Vdc to 30 Vdc (0 Vdc to 5 Vdc, 3-wire)
5 Vdc to 30 Vdc (0.5 Vdc to 2.5 Vdc, 3-wire)
14 Vdc to 30 Vdc (0 Vdc to 10 Vdc, 3-wire)
Effect ± 0.01%/ °F for zero and span
Storage -22 °F to 175 °F (-30 °C to 80 °C)
Medium 14 °F to 122 °F (-10 °C to 50 °C)
Optional PT100, 4-wire per IEC 60751
(industrial locations)
per EN 6100- 4- 5; 1.5J
Less than ± 0.05% full scale effect for 100 g’s @ 20 ms on any axis
Less than ± 0.01% full scale effect for 15 g’s @ 0 Hz to 2,000 Hz on any axis
″ NPT conduit
12
* Unregulated power supplies
61 3
SERIES
ORDERING INFORMATION
SERIES 613
PRESSURE
RANGES
ACCURACIES 1 ±0.25% full scale (BFSL) 2 ±0.125% full scale (BFSL)
OUTPUT SIGNALS 1 4 mA to 20 mA, 2-wire 5 0 Vdc to 10 Vdc, 3-wire
ELECTRICAL
CONNECTIONS
OPTIONS CC Cable Clamp FE Filter Element LP
1
Only available with PUR cable
5 0 psi to 5 psi (11.55 ft/H
10 0 psi to 10 psi (23.10 ft/H
15 0 psi to 15 psi (34.65 ft/H
2 0 Vdc to 5 Vdc, 3-wire 11 0.5 Vdc to 2.5 Vdc, 3-wire
-XX Standard Polyurethane (PUR) cable -38-XX FEP cable
NOTE: XX=length of cable in feet.
DC Desiccant Cartridge JB Cable Junction Box (NEMA 4X) LR Lifting Ring
O) 20 0 psi to 20 psi (46.20 ft/H2O) 75 0 psi to 75 psi (173.25 ft/H2O) 300 0 psi to 300 psi (693 ft/H
2
O) 30 0 psi to 30 psi (69.30 ft/H2O) 100 0 psi to 100 psi (231.00 ft/H
2
O) 50 0 psi to 50 psi (115.50 ft/H2O) 150 0 psi to 150 psi (346.50 ft/H
2
Lightning Protection
1
Please consult your local NOSHOK Distributor or NOSHOK, Inc. for availability and delivery information.
613 – 5 – 1 – 1 – 50' – LP EXAMPLE
Series ...........................................................613
Pressure range ......................... 0 psig to 5 psig
Accuracy ...............................................±0.25%
Output signal ................4 mA to 20 mA, 2-wire
Electrical connection ........ Subm ersible cable
Option .................................Lightning Protec tion
ORDERING INFORMATION
DIMENSIONS
WIRING DIAGRAMS
ELECTRICAL CONNECTIONS
O)
2
O)
2
PT1
PT100 RTD
O)
2
1
Outline Dimensions
1/2″ NPT
Ø 1.06″
(27 mm)
1.25″
1.75″
(44 mm)
(32 mm)
1.06″
(27 mm)
.25″
(6 mm)
2.14″
(54 mm)
Active area
Ø 3.75″
(95 mm)
4.44″
(113 mm)
Optional Cable Clamp
Optional Desiccant Cartridge
Optional Cable Junction Box
Optional Filter Element
Optional Lifting Ring