Gauge Inspection:
Please read the pr gauge body to insure that this gauge is the same gauge
size, materials of construction, working pressure, di eren­tial pressure, etc. Inspect for any shipping damage and, if discovered, report it immediately.
Product Design Features:
The NOSHOK 1200 Series is designed for working pressures to 3,000 psig, with an over-range pressure and di
erential pressures to 600 psid. This series is supplied, standard, with a 4.5” dial or, optionally, with a 6” dial. The gauge has a 316L sensor cell, encapsulating opposed, high (+) and low (-) side
pressur them to move. This movement is transferred to a torque-tube assembly, linked to a horizontally moving, bidirectional over­pressure valve (This valve protects the sensor membranes against damage from high (+) and low (-) side overpressure of the membranes in the sensor cell.) A torsion rod, located within the torque-tube assembly, passes through a sealed compr
rom the dial case assembly) into the dial case and is connected to a pinion/sector gear and pointer assembly. The twisting motion of the torsion rod, driven by the membrane movement, is
ree, linear arc and pointer travel.
The gauge is supplied, standard, for panel mounting. The mounting method is from front to back in the panel and the gauge is secured in the panel with four (4) threaded studs, supplied with the gauge. Optional pipe or wall mount kits are available.
Gauge Connections:
Standard (2) x 1/4” FNPT back connections with high (+) and low (-) connections clearly indicated. Optional connection sizes and/or dual top/bottom connections are available.
Troubleshooting:
If the gauge is not indicating di
erential pressure, check to insure both the high (+) and low (-) side connections have been properly installed. Check to insure that there is pres­sure to the high (+) side of the gauge and that there is dif­ferential pressure across the device being monitored by the 1200 Series. If the gauge is being used together with a three-valve manifold (recommended), check to insure that the high (+) and low (-) valves are in the open position and the equalizer valve is in the closed position. If, after following these steps with no positive result, please contact the NOSHOK Customer Service Department or your nearest NOSHOK Distributor.
Gauge Mounting:
Design and Operating Principle
Process pressures p1 and p2 are applied to the chambers
- (2) and + (3).
Di erential pressure across + and - pressure sides
The displacement of the connection rod (5) is converted
through the use of a transmitting lever (6) into rotation,
which is transferred over an axial shaft (7) to the move-
ment (9).
The torque pipe (8) seals, assuring a frictionless path.
Overpressure protection in both directions up to the max.
static pressure rating is provided by contoured metal
bolsters.