Wiring Mini-Hirschmann
connector
Wiring M12 x 1 4-pin
round connector
Current output, 2 wire
Power
Supply
Output
Power
Supply
Output
+ Supply
3
+ Output
+ Supply
+ Output
1
2
Power
Supply
2 WIRE
WIRING
DIAGRAM
EXAMPLE
SERIES 100
Red
Black
Output
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Series 100 4 mA to 20 mA 2-Wire
+ Supply Red/1/A/1/Brown
+ Output Black/2/B/3/Blue
Example: Red/1/A/1 = Applicable color
wire/din plug number/bendix pin/M12 x 1
pin number/M12 color wire
SERIES 600
Load Limitations
4 mA to 20 mA Output Only
Output
Vmin = 10V + (.020 x R
RL = RS + RW
L)
Power
Supply
Red
Black
RL = Loop Resistance (ohms)
L)
2 WIRE WIRING
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Series 600 4 mA to 20 mA 2-Wire
+ Supply Red/1
+ Output Black/2
Series 600 Voltage Output
+ Supply Red/1
Common Black/2
+ Output White/3
Example: Red/1 = Applicable color wire/din
plug number.
DIAGRAM EXAMPLE
Red
Power
Supply
Black
•
3 WIRE WIRING
DIAGRAM EXAMPLE
White
Output
Red
Power
Supply
Black
2 WIRE WIRING
DIAGRAM EXAMPLE
Output
SERIES 615/616
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Series 615/616 4 mA to 20 mA 2-Wire
+ Supply Red/1/A/1/1/Brown
+ Output Black/2/B/2/3/Blue
Series 615/616 Voltage Output
+ Supply Red/1/A/1/1/Brown
Common Black/2/B/2/3/Blue
+ Output White/3/C/3/4/Black
Example: Red/1/A/1/1 = Applicable color
wire/din plug number/bendix pin/junction box
pin/M12 x 1 pin number/M12 color wire
L)
Red
Power
Supply
Black
White
•
3 WIRE WIRING
DIAGRAM EXAMPLE
Output
Wiring Mini-Hirschmann
connector
Wiring M12 x 1 4-pin
round connector
Voltage output, 3 wire
Power
Supply
Output
Power
Supply
Output
+ Supply
+ Output
•
Common
+ Supply
+ Output
•
Common
1
1
3
3
Power
Supply
2
3 WIRE
WIRING
DIAGRAM
EXAMPLE
SERIES 200
Red
Black
•
White
Output
Series 200 0-5, 1-6, 0-10
1 Vdc to 11 Vdc 3-WIRE
+ Supply Red/1/A/1/Brown
Common Black/2/B/3/Blue
+ Output White/3/C/4/Black
Example: Red/1/A/1 = Applicable color
wire/din plug number/bendix pin/M12 x 1
pin number/M12 color wire
Blue
Power
Supply
Red
Black
2 WIRE WIRING
DIAGRAM EXAMPLE
Load Limitations
4 mA to 20 mA Output Only
Vmin = [10V + (.020 x R
Output
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Series 612 4 mA to 20 mA 2-Wire
+ Supply Red
+ Output Black
Case ground Blue
Series 612 Voltage Output
+ Supply Red
Common Black
+ Output White
Case ground Blue
SERIES 612
L)] - O.04354
cable length
SERIES 300
Blue
Power
Supply
Red
Power
Black
•
White
Output
Supply
Ω
x
Ft.
Red
Black
Output
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
RL = RS + RW
L)
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Series 300 4 mA to 20 mA 2-Wire
+ Supply Red/1/1/1/Brown
+ Output Black/2/2/3/Blue
Series 300 Voltage Output
+ Supply Red/1/1/1/Brown
Common Black/2/2/3/Blue
+ Output White/3/3/4/Black
3 WIRE WIRING
DIAGRAM EXAMPLE
2 WIRE WIRING
DIAGRAM EXAMPLE
Example: Red/1/1/1 = Applicable color
wire/din plug number/junction box pin/
M12 x 1 pin number/M12 color wire
Red
Power
Supply
Black
•
White
3 WIRE WIRING
DIAGRAM EXAMPLE
Output
Wiring - M12 x 1 4-pin
Current output, 2 wire
Power
Supply
Output
Voltage output, 3 wire
Power
Supply
Output
Wiring - Mini-Hirschmann
connector
Current output, 2 wire
+ Supply
Power
Supply
Output
Voltage output, 3 wire
Power
Supply
Output
+ Supply
+ Output
•
+ Output
Common
round connector
+ Supply
+ Output
+ Supply
+ Output
Common
•
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
RL = RS + RW
RL = Loop Resistance (ohms)
1
3
1
3
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
2
2
Example: Brown/1/1 = Applicable color wire/din
plug number M12 x 1 Pin number/M12 color
wire
SERIES 640
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
RL = RS + RW
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
RS 232 Interface
SERIES 660
L)
Series 660 4 mA to 20 mA 2-Wire
+ Supply Brown/1/1/Brown
+ Output Green/2/3/Blue
Series 660 Voltage Output
+ Supply Brown/1/1/Brown
Common Green/2/3/Blue
+ Output White/3/4/Black
L)
Wiring - M12 x 1 4-pin
round connector
Current output, 2 wire
+ Supply
Power
Supply
Output
Voltage output, 3 wire
Power
Supply
Output
+ Output
+ Supply
•
+ Output
Common
Pressure
Sensor
SERIES 680
Wiring - Mini-Hirschmann
connector
Current output, 2 wire
+ Supply
Power
Supply
Output
+ Output
Voltage output, 3 wire
+ Supply
Power
Supply
Output
+ Output
•
Common
Load Limitations
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
RL = RS + RW
L)
RL = Loop Resistance (ohms)
1
3
1
3
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
2
2
Series 680 4 mA to 20 mA 2-Wire
+ Supply Red/1/1/Brown
+ Output Black/2/3/Blue
Series 680 Voltage Output
+ Supply Red/1/1/Brown
Common Black/2/3/Blue
+ Output White/3/4/Black
Example: Red/1/1 = Applicable color wire/din
plug number M12 x 1 Pin number/M12 color
wire
Wiring - M12 x 1 4-pin
round connector
Current output, 2 wire
Power
Supply
Output
Voltage output, 3 wire
Power
Supply
Output
SERIES 800
Load Limitations
4 mA to 20 mA, 2 wire 0 Vdc to 10 Vdc, 3 wire
+ Supply
Power
Supply
Output
+ Output
4 mA to 20 mA Output Only
Vmin = 10V + (.020 x R
RL = RS + RW
L)
RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms)
RW = Wire Resistance (ohms)
Series 800 4 mA to 20 mA 2-Wire
+ Supply Red/1
+ Output Black/2
Series 800 Voltage Output
+ Supply Red/1
Common Black/2
+ Output White/3
Example: Red/1 = Applicable color wire/din
plug number.
Power
Supply
Output
+ Supply
+ Output
+ Supply
+ Output
•
Common
+ Supply
+ Output
•
Common
Installation:
NOSHOK pressure transmitters/transducers may
be mounted in any plane with negligible effect on
performance.Although these units are designed
and manufactured to withstand substantial shock
and vibration, it is recommended that they be
mounted in an area of minimal vibration. Always
use a wrench on the wrench flats when installing.
NEVER use a pipe wrench on the housing or in
the area of the electrical connection.
Maintenance/Calibration:
NOSHOK pressure transmitters/transducers
require no maintenance. Recalibration is
dependent on the users Quality Assurance
Program. If no program is in place, NOSHOK
recommends a 1 year cycle.
Alignment Procedure (applies only to 100,
200, 615/616, and 640 series):
Using a pressure source and meter with adequate
accuracy, perform the following steps:
• Open sensor
• With no pressure applied,
adjust the “Z”
potentiometer for the
correct Zero output
• Apply the correct full scale
pressure to the unit
• Adjust the “S”
potentiometer for the
correct Span output
NWD 08-2
Span
Zero
NOSHOK
TRANSMITTERS
TRANSDUCERS
Wiring Diagrams & Electrical
Connections for:
100, 200, 300, 600, 612, 615/616,
640, 660, 680 and 800 Series
CORPORATE HEADQUARTERS
1010 West Bagley Rd. • Berea, OH 44017
440-243-0888 • FAX 440-243-3472
E-mail: noshok@noshok.com
Web: www.noshok.com